1.Four new lanostane triterpenoids from latex of Euphorbia resinifera.
Miao-Miao LI ; Yan-Ru QI ; Ya-Ping FENG ; Wei LIU ; Tao YUAN
China Journal of Chinese Materia Medica 2021;46(18):4744-4748
Four new lanostane triterpenoids, 3β-hydroxy-12α-methoxylanosta-7,9(11),24-triene(1), 3β-hydroxy-12α-methoxy-24-methylene-lanost-7,9(11)-dien(2), 3,7-dioxo-lanosta-8,24-diene(3), and 3,7-dioxo-24-methylene-lanost-8-en(4), were isolated from the latex of Euphorbia resinifera with a variety of chromatography methods. Their structures were elucidated based on spectroscopic data and/or comparison with the data reported in previous research. Compounds 1, 2, and 4 showed moderate inhibition of LPS-induced NO production by RAW264.7, with IC_(50) of 30.4, 37.5, and 28.3 μmol·L~(-1), respectively.
Euphorbia
;
Latex
;
Molecular Structure
;
Steroids
;
Triterpenes
2.Two Serum Free Light Chain Detection Systems in the Diagnosis of Multiple Myeloma.
Guo-Qing ZHU ; Xue FU ; Yan-Song REN ; Yan-Sheng WANG ; Shou-Lei WANG ; Li-Cheng WANG ; Jun LIN ; Gang AN
Journal of Experimental Hematology 2021;29(4):1209-1215
OBJECTIVE:
To investigate the comparability of the Freelite, Binding Site, Beckman and N Latex FLC, Siemens in the detection of serum free light chain (sFLC) .
METHODS:
Fifty newly diagnosed multiple myeloma (MM) patients in Tianjin Institute of Blood Research from November 2019 to February 2020 were enrolled. The two systems (Freelite, Binding Site, Beckman and N Latex FLC, Siemens) were used to detect the sFLC of the samples. Outlier detection was performed by ESD method, methodological comparison and deviation assessment were performed by Passing-Bablok regression and Bland-Altman regression.
RESULTS:
Both the systems could quantitatively analyze free kappa light chain serum samples and free lambda light chain samples. Freelite, Binding Site, Beckman and N Latex FLC, Siemens free light chain test showed FLC-κ:36.5 (6.5, 194), 40.5 (6.94, 288), FLC-λ: 30.1 (4.3, 170.5), 35.1 (2.28, 526), rFLC (FLC-κ/ FLC-λ) : 0.82 (0.05, 43.25), 1.03 (0.03, 32.04), dFLC (|FLC-κ- FLC-λ|) : -5.8 (-161.97, 183.7), 1.1 (-505.1, 279.01), which existed no outliers. There were systematic differences, and the deviation level was not within the clinically acceptable range.
CONCLUSION
Both the systems can meet the needs of clinical diagnosis and treatment, but there is a significant deviation between the two systems, the results are not comparable, and should be analyzed separately. In particular, the same system should be selected for monitoring the prognosis of MM.
Humans
;
Immunoglobulin Light Chains
;
Immunoglobulin kappa-Chains
;
Immunoglobulin lambda-Chains
;
Latex
;
Multiple Myeloma/diagnosis*
3.Association between fruit and vegetable allergies and pollen-food allergy syndrome in Japanese children: a multicenter cross-sectional case series
Yutaka TAKEMURA ; Yuri TAKAOKA ; Tomoyuki ARIMA ; Hiroki MASUMI ; Koji YAMASAKI ; Megumi NAGAI ; Keisuke SUGIMOTO ; Masaaki HAMADA ; Tomoko TAKANO ; Masaaki DOI ; Tomoko KAWAKAMI ; Makoto KAMEDA
Asia Pacific Allergy 2020;10(1):9-
BACKGROUND: Recently, the prevalence of food allergies during childhood is increasing, with fruits being common allergens. However, data on allergens that cause fruit and vegetable allergies and pollen-food allergy syndrome (PFAS) in childhood are relatively few. This study aimed to examine the allergens in fruit and vegetable allergies in pediatric patients and to determine the association between fruit and vegetable allergies and PFAS.OBJECTIVE: This study aimed to examine the current status of fruit and vegetable allergies in Japanese children.METHODS: This was a multicenter case series observational study. The participants included children aged <15 years who developed allergic symptoms after eating fruits and vegetables and subsequently received treatment in the Pediatric Department of 6 hospitals in the Osaka Prefecture in Japan during the study period from August 2016 to July 2017. Participants' information was obtained using a questionnaire, and data were obtained by performing several types of allergy tests using blood samples.RESULTS: A total of 97 children (median age, 9 years; 56 males) were included in the study. Apple was the most common allergen, followed by peach, kiwi, cantaloupe, and watermelon. A total of 74 participants (76%) exhibited allergic symptoms due to PFAS; moreover, pathogenesis-related protein-10 (PR-10) was the most common allergen superfamily. On the contrary, in the group where neither PR-10 nor profilin was sensitized, kiwi and banana were the most common allergens, and the age of onset was lower than that in the PFAS group. Specific antibody titer was significantly associated with Birch for Bet v1 and latex for Bet v2 (r = 0.99 and r = 0.89).CONCLUSION: When we examine patients with fruit and vegetable allergies, we should first consider PFAS even in childhood specifically for children greater than 4 years old.
Age of Onset
;
Allergens
;
Asian Continental Ancestry Group
;
Betula
;
Child
;
Citrullus
;
Clinical Study
;
Cucumis melo
;
Eating
;
Food Hypersensitivity
;
Fruit
;
Humans
;
Hypersensitivity
;
Japan
;
Latex
;
Musa
;
Observational Study
;
Prevalence
;
Profilins
;
Prunus persica
;
Rhinitis
;
Rhinitis, Allergic, Seasonal
;
Vegetables
4.Banana anaphylaxis in Thailand: case series
Ratchataporn THONGKHOM ; Supa ONCHAM ; Mongkhon SOMPORNRATTANAPHAN ; Wannada LAISUAN
Asia Pacific Allergy 2020;10(1):4-
BACKGROUND: Banana fruit has been recognized as an important food allergen source. Nowadays banana hypersensitivity had been reported more frequently with various presentations from oral allergy syndrome to anaphylaxis.OBJECTIVE: This study aims to describe the pattern of banana hypersensitivity and the sensitivity of diagnostic test.METHODS: Six patients who experienced banana hypersensitivity were recruited from adult allergy clinic, Ramathibodi Hospital, Mahidol University between 2015–2018. Demographic data, pattern of banana allergy consisted of the onset of reaction, symptoms, severity, cross-reactivity to kiwi, avocado, latex including type and amount of banana were collected. Skin test, serum specific IgE to banana and open-label food challenge test had been applied.RESULTS: All patients experienced multiple episodes of banana anaphylaxis. Regarding the diagnostic investigation, prick-to-prick skin test had higher sensitivity (sensitivity, 100%; 95% confidence interval [CI], 54.07%–100%) than the commercial banana extract (sensitivity, 83.33%; 95% CI, 35.88%–99.58%) and serum specific IgE to banana (sensitivity, 50%; 95% CI, 11.81%–88.19%). The discordance between skin prick test using commercial banana extract and skin test was reported. The cross-reactivity between the species of banana, kiwi, the avocado was documented in all patients. Latex skin prick test and application test were applied with negative results. From the oral food challenge test, a case of banana anaphylaxis patient can tolerate heated banana.CONCLUSION: The various phenotypes of banana hypersensitivity were identified. The prick-to-prick test showed the highest sensitivity for diagnosis of banana allergy. However, component resolved diagnostics might be needed for conclusive diagnosis.
Adult
;
Anaphylaxis
;
Diagnosis
;
Diagnostic Tests, Routine
;
Food Hypersensitivity
;
Fruit
;
Hot Temperature
;
Humans
;
Hypersensitivity
;
Hypersensitivity, Immediate
;
Immunoglobulin E
;
Latex
;
Musa
;
Persea
;
Phenotype
;
Skin
;
Skin Tests
;
Thailand
5.Natural Latex Rubber Condom Inspection and Exploratory Research Analysis.
Yucheng ZHANG ; Haiyan WANG ; Fang HU
Chinese Journal of Medical Instrumentation 2020;44(2):163-165
According to the situation of 34 batches of natural rubber latex condoms tested by our center in 2018, the unqualified items in the product inspection items and the exploratory research results of D4 and D5 content in silicone oil lubricants are analyzed. We make recommendations on product technical requirements or standards to strengthen the quality supervision of products.
Condoms/standards*
;
Latex
;
Silicone Oils
6.In Vivo Vibration Measurement of Middle Ear Structure Using Doppler Optical Coherence Tomography: Preliminary Study
Doekmin JEON ; Nam Hyun CHO ; Kibeom PARK ; Kanghae KIM ; Mansik JEON ; Jeong Hun JANG ; Jeehyun KIM
Clinical and Experimental Otorhinolaryngology 2019;12(1):40-49
OBJECTIVES: Doppler optical coherence tomography (DOCT) is useful for both, the spatially resolved measurement of the tympanic membrane (TM) oscillation and high-resolution imaging. We demonstrated a new technique capable of providing real-time two-dimensional Doppler OCT image of rapidly oscillatory latex mini-drum and in vivo rat TM and ossicles. METHODS: Using DOCT system, the oscillation of sample was measured at frequency range of 1–4 kHz at an output of 15 W. After the sensitivity of the DOCT system was verified using a latex mini-drum consisting of a 100 μm-thick latex membrane, changes in displacement of the umbo and contacted area between TM and malleus in normal and pathologic conditions. RESULTS: The oscillation cycles of the mini-drum for stimulus frequencies were 1.006 kHz for 1 kHz, 2.012 kHz for 2kHz, and 3.912 kHz for 4 kHz, which means that the oscillation cycle of the mini-drum become short in proportional to the frequency of stimuli. The oscillation cycles of umbo area and the junction area in normal TM for frequencies of the stimuli showed similar integer ratio with the data of latex mini-drum for stimuli less than 4 kHz. In the case of middle ear effusion condition, the Doppler signal showed a tendency of attenuation in all frequencies, which was prominent at 1 kHz and 2 kHz. CONCLUSION: The TM vibration under sound stimulation with frequencies from 1 kHz to 4 kHz in normal and pathologic conditions was demonstrated using signal demodulation method in in vivo condition. The OCT technology could be helpful for functional and structural assessment as an optional modality.
Animals
;
Ear, Middle
;
Latex
;
Malleus
;
Membranes
;
Methods
;
Otitis Media with Effusion
;
Rats
;
Tomography, Optical Coherence
;
Tympanic Membrane
;
Vibration
7.The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
Sakiko HIRAOKA ; Shiho TAKASHIMA ; Toshihiro INOKUCHI ; Asuka NAKARAI ; Masahiro TAKAHARA ; Keita HARADA ; Yasuhiro SEKI ; Katsunori WATANABE ; Jun KATO ; Hiroyuki OKADA
Intestinal Research 2019;17(2):202-209
BACKGROUND/AIMS: Fecal calprotectin (Fcal) as well as the fecal immunochemical test (FIT) are useful biomarkers for detecting activity and mucosal healing in inflammatory bowel diseases. Here, we report the performance of simultaneous measurements of Fcal and FIT for ulcerative colitis (UC) patients using the newly-developed latex agglutination turbidimetric immunoassay (LATIA) system. METHODS: Fcal and hemoglobin were measured by the LATIA system in 152 UC patients who underwent colonoscopy. Fcal was also quantified with a conventional enzyme-linked immunosorbent assay (ELISA). Fecal markers were evaluated in conjunction with the mucosal status of UC, which was assessed via the Mayo endoscopic subscore (MES) classification. RESULTS: The LATIA system could quantify calprotectin and hemoglobin simultaneously with the same fecal samples within 10 minutes. The values of the Fcal-LATIA closely correlated with those of the Fcal-ELISA (Spearman rank correlation coefficient, r=0.84; P<0.0001). The values of Fcal for each assay and the FIT all significantly correlated with the MESs (Spearman rank correlation coefficient, Fcal-LATIA: r=0.58, Fcal-ELISA: r=0.55, and FIT: r=0.72). The mucosal healing predictability (determined by an MES of 0 alone) of the Fcal-LATIA, Fcal-ELISA, and FIT-LATIA with the cutoffs determined by receiver operating characteristic curve analysis was 0.79, 0.78, and 0.92 for sensitivity, respectively, and 0.78, 0.69, and 0.73 for specificity, respectively. CONCLUSIONS: The performance of the novel Fcal-LATIA was equivalent to that of the conventional Fcal assay. Simultaneous measurements with FITs would promote the clinical relevance of fecal biomarkers in UC.
Agglutination
;
Biomarkers
;
Classification
;
Colitis, Ulcerative
;
Colonoscopy
;
Enzyme-Linked Immunosorbent Assay
;
Feces
;
Humans
;
Immunoassay
;
Inflammatory Bowel Diseases
;
Latex
;
Leukocyte L1 Antigen Complex
;
ROC Curve
;
Sensitivity and Specificity
8.Analyses of the Proficiency Testing Program and the Performance of Qualitative Reagents for Rheumatoid Factor
Journal of Laboratory Medicine and Quality Assurance 2019;41(2):105-110
BACKGROUND: Rheumatoid factor (RF) is used as one of the diagnostic criteria for rheumatoid arthritis. The purpose of this study was to evaluate qualitative RF reagents used in clinical laboratories in Korea, and to provide basic data that can be used as a reference to improve the quality of RF testing. METHODS: We reviewed the proficiency testing results for RF from the Korean Association of External Quality Assessment Service (KEQAS) and College of American Pathologists. Moreover, we evaluated five commercially available RF qualitative reagents, including LabSlide RF (IVD Lab Co., Korea), ASAN RA Latex Reagents (Asan Pharmaceuticals Co., Korea), RaPET RF (Stanbio Laboratory, USA), RF Latex Test (Pulse Scientific Inc., Canada), and RF-100 (Teco Diagnostics, USA). Commercially available quality control materials, calibrators, and pooled sera were used in this study. The consistency of qualitative reagents and Kappa statistics were calculated based on the quantitative values of the quality control materials and the mixed sera. RESULTS: Up to 51.5% of high concentration samples were reported as negative in KEQAS. RF qualitative reagent test results were not consistent among reagent types. The consistency of the qualitative and quantitative test results was between 51% and 100%, and the kappa statistics varied depending on the reagent manufacturer. CONCLUSIONS: Measurement of RF qualitative reagents used in domestic clinical laboratories was not consistent with the quantitative values, and hence it is necessary to improve the consistency and verify the adequacy of the cut-off value.
Arthritis, Rheumatoid
;
Chungcheongnam-do
;
Indicators and Reagents
;
Korea
;
Latex
;
Quality Control
;
Rheumatoid Factor
9.Comparison of Neck Pain, Shoulder Pain, and Comfort between Buckwheat and Latex Pillows
Korean Journal of Health Promotion 2019;19(2):107-113
BACKGROUND: This study aimed to investigate differences in neck pain, shoulder pain, and comfort between buckwheat and latex pillows in elderly sanatorium residents. METHODS: The crossover experimental study was performed with 30 elderly patients in a convalescent hospital for seniors. The buckwheat and latex pillows were used for 2 weeks, the 7 day was assigned as the washout between each one week intervention, respectively. Pre- and posttest visual analog scale (VAS) scores for neck and shoulder pains and the neck disability index (NDI) were investigated. Data were analyzed using paired-samples t test, and their correlations were analyzed using SPSS/WIN 21.0 (IBM Corp., New York, NY, USA). RESULTS: After the 2-week intervention, results showed that the use of buckwheat pillows decreased the VAS scores for neck and shoulder pains and NDI. Further, the use of latex pillows decreased the VAS score for neck pain and NDI, but the VAS score for shoulder pain showed no statistically significant differences (t=1.887, P=0.069). CONCLUSION: In conclusion, using latex and buckwheat pillows is the best option for reducing neck pain. Between the buckwheat and latex pillows, the buckwheat pillow is a better option for decreasing neck and shoulder pains.
Aged
;
Fagopyrum
;
Hospitals, Convalescent
;
Humans
;
Latex
;
Neck Pain
;
Neck
;
Shoulder Pain
;
Shoulder
;
Visual Analog Scale
10.Report on the External Quality Assessment Scheme of Serologic Tests for Syphilis in Korea (2016–2017).
Seung Jung KEE ; Ju Hyeon SHIN ; Hyun Seung LEE ; Sang Gon LEE
Journal of Laboratory Medicine and Quality Assurance 2018;40(4):182-187
The 2016–2017 surveys on the external quality assessment scheme for serologic tests for syphilis in Korea were conducted by the Korean Association of External Quality Assessment Service. Proficiency testing (PT) panels consisting of three pooled serum samples were shipped to 430 and 432 laboratories participating in the program in the 1st and 2nd trials of 2016 and 465 and 503 laboratories in the 1st and 2nd trials of 2017, respectively. The rates of returning results were 94.2% and 50.2% for non-treponemal and treponemal tests, respectively, in the 1st trial of 2016; 94.7% and 49.5% in the 2nd trial of 2016; 94.2% and 49.5% in the 1st trial of 2017; and 92.8% and 48.7% in the 2nd trial of 2017, respectively. The most commonly used methods for non-treponemal tests were rapid plasma reagin (RPR) card test, followed by RPR turbidoimmunoassay and venereal disease research laboratory tests. The most commonly used methods for treponemal tests were Treponema pallidum particle agglutination, followed by immunochromatographic assay, Treponema pallidum latex agglutination, chemiluminescence immunoassay, and fluorescent treponemal antibody-absorption. The accuracy rates of the 2017 PT for non-treponemal and treponemal tests were 92.5%–99.8% and 93.3%–100.0%, respectively, which were significantly lower compared to the 98.4%–100.0% and 97.0%–100.0% in 2016. A possible explanation for the lower accuracy rates in the 2017 PT survey is the matrix effect caused by pooling multiple individual serum samples. These data suggest that pooling of serum samples obtained from a small number of donors may help avoid the matrix effect affecting standard materials used for syphilis serology PT.
Agglutination
;
Humans
;
Immunoassay
;
Immunochromatography
;
Korea*
;
Latex
;
Luminescence
;
Plasma
;
Serologic Tests*
;
Sexually Transmitted Diseases
;
Ships
;
Syphilis*
;
Tissue Donors
;
Treponema pallidum

Result Analysis
Print
Save
E-mail