1.Heterogeneity of Adipose Tissue From a Single-cell Transcriptomics Perspective
Yong-Lang WANG ; Si-Si CHEN ; Qi-Long LI ; Yu GONG ; Xin-Yue DUAN ; Ye-Hui DUAN ; Qiu-Ping GUO ; Feng-Na LI
Progress in Biochemistry and Biophysics 2025;52(4):820-835
Adipose tissue is a critical energy reservoir in animals and humans, with multifaceted roles in endocrine regulation, immune response, and providing mechanical protection. Based on anatomical location and functional characteristics, adipose tissue can be categorized into distinct types, including white adipose tissue (WAT), brown adipose tissue (BAT), beige adipose tissue, and pink adipose tissue. Traditionally, adipose tissue research has centered on its morphological and functional properties as a whole. However, with the advent of single-cell transcriptomics, a new level of complexity in adipose tissue has been unveiled, showing that even under identical conditions, cells of the same type may exhibit significant variation in morphology, structure, function, and gene expression——phenomena collectively referred to as cellular heterogeneity. Single-cell transcriptomics, including techniques like single-cell RNA sequencing (scRNA-seq) and single-nucleus RNA sequencing (snRNA-seq), enables in-depth analysis of the diversity and heterogeneity of adipocytes at the single-cell level. This high-resolution approach has not only deepened our understanding of adipocyte functionality but also facilitated the discovery of previously unidentified cell types and gene expression patterns that may play key roles in adipose tissue function. This review delves into the latest advances in the application of single-cell transcriptomics in elucidating the heterogeneity and diversity within adipose tissue, highlighting how these findings have redefined the understanding of cell subpopulations within different adipose depots. Moreover, the review explores how single-cell transcriptomic technologies have enabled the study of cellular communication pathways and differentiation trajectories among adipose cell subgroups. By mapping these interactions and differentiation processes, researchers gain insights into how distinct cellular subpopulations coordinate within adipose tissues, which is crucial for maintaining tissue homeostasis and function. Understanding these mechanisms is essential, as dysregulation in adipose cell interactions and differentiation underlies a range of metabolic disorders, including obesity and diabetes mellitus type 2. Furthermore, single-cell transcriptomics holds promising implications for identifying therapeutic targets; by pinpointing specific cell types and gene pathways involved in adipose tissue dysfunction, these technologies pave the way for developing targeted interventions aimed at modulating specific adipose subpopulations. In summary, this review provides a comprehensive analysis of the role of single-cell transcriptomic technologies in uncovering the heterogeneity and functional diversity of adipose tissues.
2.Analysis of Gene Mutations Distribution and Enzyme Activity of G6PD Deficiency in Newborns in Guilin Region.
Dong-Mei YANG ; Guang-Li WANG ; Dong-Lang YU ; Dan ZENG ; Hai-Qing ZHENG ; Wen-Jun TANG ; Qiao FENG ; Kai LI ; Chun-Jiang ZHU
Journal of Experimental Hematology 2025;33(5):1405-1411
OBJECTIVE:
To analyze the distribution characteristics of glucose-6-phosphate-dehydrogenase (G6PD) mutations and their enzyme activity in newborns patients with G6PD deficiency in Guilin region.
METHODS:
From July 2022 to July 2024, umbilical cord blood samples from 4 554 newborns in Guilin were analyzed for G6PD mutations using fluorescence PCR melting curve analysis. Enzyme activity was detected in 4 467 cases using the rate assay.
RESULTS:
Among 4 467 newborns who underwent G6PD activity testing, 162 newborns (3.63%) were identified as G6PD-deficient, including 142 males (6.04%) and 20 females (0.94%), the prevalence of G6PD deficiency was significantly higher in males than in females (P < 0.001). Genetic analysis of 4 554 newborns detected G6PD mutations in 410 cases (9%), including 171 males (7.13%) and 239 females (11.09%), with a significantly higher mutation detection rate in females than in males (P < 0.001). A total of nine single mutations and four compound heterozygous mutations were identified. The most common mutations were c.1388G>A (33.66%), c.1376G>T (23.66%) and c.95A>G (16.34%). Among newborns who underwent both enzyme activity and genetic mutation testing, males with G6PD mutations had significantly lower enzyme activity than that of females with G6PD mutations(P < 0.001). Specifically, among newborns carrying the mutations c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T or c.871G>A, males consistently exhibited lower enzymatic activity than females with the same mutations (P < 0.001). Furthermore, in male G6PD-deficient newborns, the enzyme activity levels in those carrying c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T, or c.871G>A were lower than those in both the control group and the c.519C>T group (P < 0.05).
CONCLUSION
This study provides a comprehensive profile of G6PD deficiency incidence and mutation spectrum in the Guilin region. By analyzing enzyme activity and genetic mutation results, this study provides insights into potential intervention strategies and personalized management approaches for the prevention and treatment of neonatal G6PD deficiency in the region.
Humans
;
Infant, Newborn
;
Glucosephosphate Dehydrogenase Deficiency/epidemiology*
;
Glucosephosphate Dehydrogenase/genetics*
;
Female
;
Male
;
Mutation
;
China/epidemiology*
3.Short-term effects of ambient ozone on pediatric pneumonia hospital admissions: a multi-city case-crossover study in China.
Huan WANG ; Huan-Ling ZENG ; Guo-Xing LI ; Shuang ZHOU ; Jin-Lang LYU ; Qin LI ; Guo-Shuang FENG ; Hai-Jun WANG
Environmental Health and Preventive Medicine 2025;30():75-75
BACKGROUND:
Children's respiratory health demonstrates particular sensitivity to air pollution. Existing evidence investigating the association between short-term ozone (O3) exposure and childhood pneumonia remains insufficient and inconsistent, especially in low- and middle-income countries (LMICs).
METHOD:
To provide more reliable and persuasive evidence, we implemented a multi-city, time-stratified case-crossover design with a large sample size, using data from seven representative children's hospitals across major geographical regions in China. To avoid the impact of the COVID-19 pandemic, individual-level medical records of inpatient children under 6 years of age diagnosed with pneumonia during 2016-2019 were collected. Conditional logistic regression models were fitted for each city, and city-specific estimates were pooled through a meta-analysis using a random-effects model.
RESULTS:
In total, the study included 137,470 pediatric pneumonia hospital admissions. The highest pooled estimate for O3 occurred at lag0-1, with a 10 µg/m3 increase in O3 associated with a 1.57% (95% CI: 0.67%-2.48%) higher risk of pediatric pneumonia hospital admissions. Stratified analyses indicated that the effects of O3 were robust across different sexes, age groups, and admission seasons. We also observed a statistically significant increase in risk associated with O3 concentrations exceeding the World Health Organization Air Quality Guidelines (WHO-AQGs).
CONCLUSIONS
This study revealed a significant positive association between O3 and pediatric pneumonia hospital admissions. Our findings substantially strengthen the evidence base for the adverse health impacts of O3, underscoring the importance of O3 pollution control and management in reducing the public health burden of pediatric pneumonia.
Humans
;
Ozone/analysis*
;
China/epidemiology*
;
Pneumonia/chemically induced*
;
Child, Preschool
;
Male
;
Female
;
Infant
;
Cross-Over Studies
;
Air Pollutants/analysis*
;
Hospitalization/statistics & numerical data*
;
Child
;
Cities/epidemiology*
;
Air Pollution/adverse effects*
;
Infant, Newborn
;
Environmental Exposure/adverse effects*
4.Therapeutic effect of different biliary drainage methods after laparoscopic common bile duct exploration in elderly patients with choledocholithiasis: An analysis based on propensity score matching
Kaifang DU ; Xichun WANG ; Lei WEI ; Changzhi ZHAO ; Zhongyi FENG ; Mingjie CHENG ; Hanshuo LI ; Guiling LANG
Journal of Clinical Hepatology 2025;41(11):2359-2364
ObjectiveTo investigate the safety and feasibility of intra-biliary drainage tube placement after laparoscopic common bile duct exploration in elderly patients with choledocholithiasis, and to provide more options for surgical procedures in the clinical management of elderly patients with choledocholithiasis. MethodsA retrospective analysis was performed for the clinical data of 52 elderly patients with choledocholithiasis who were admitted to Department of Hepatobiliary Surgery, Affiliated Dalian Friendship Hospital of Dalian Medical University, from November 2021 to October 2024. According to the biliary drainage method after surgery, the patients were divided into internal drainage group with 24 patients and T-tube drainage group with 28 patients, and there were 19 patients in each group after propensity score matching. The two groups were compared in terms of perioperative parameters and postoperative complications. The Wilcoxon rank-sum test was used for comparison of continuous data between two groups, and the chi-square test or the Fisher’s exact test was used for comparison of categorical data between two groups. ResultsCompared with the T-tube drainage group, the internal drainage group had a significantly shorter length of postoperative hospital stay and a significantly lower volume of postoperative bile loss (Z=-2.845 and -5.633, both P<0.05), while there were no significant differences between the two groups in time of operation, intraoperative blood loss, and drainage tube indwelling time (all P>0.05). There were no significant differences between the two groups in postoperative bile leak, stone recurrence, biliary stricture, and drainage tube-related complications, and the internal drainage group had a significantly lower total complication rate than the T-tube drainage group [1 (5.3%) vs 7 (36.8%), P<0.05]. ConclusionFor elderly patients with choledocholithiasis, intra-biliary drainage tube placement after laparoscopic common bile duct exploration can shorten the length of postoperative hospital stay, reduce bile loss, and lower the incidence rate of postoperative complications, thereby helping to accelerate postoperative recovery.
5.Correlation analysis of miR-4500,NGF expressions with preoperative magnetic resonance signs in breast cancer
Fan YANG ; Jing CHEN ; Bin ZHENG ; Jiao-Jiao LI ; Li ZHANG ; Gui-Feng BIAN ; Ya-Jing BIAN ; Xiao-Yan LANG
Journal of Regional Anatomy and Operative Surgery 2024;33(1):47-50
Objective To analyze the correlations of the expressions of miR-4500 and nerve growth factor(NGF)in breast cancer patients with preoperative magnetic resonance(MR)signs.Methods A total of 105 patients with breast cancer admitted to our hospital were selected,the mRNA expression levels of miR-4500 and NGF in breast cancer tissues and adjacent tissues of patients were detected by qRT-PCR,and the positive expression rates of NGF in breast cancer tissues and adjacent tissues were determined by immunohistochemistry method.The correlations of the expressions of miR-4500 and NGF in breast cancer tissues with clinicopathological features and MR signs of patients were analyzed.The targeting relationship between miR-4500 and NGF was predicted by the bioinformatics website,and the correla-tion between the expressions of the two was analyzed.Results Compared with the adjacent tissues,the expression level of miR-4500 in breast cancer tissue decreased(P<0.05),while the level of NGF mRNA and the positive expression rate of NGF increased(P<0.05).There was no significant difference in age,pathological type,tumor classification,parenchymal background,apparent diffusion coefficient or enhancement curve among different expressions of miR-4500 and NGF(P>0.05).The histological grade,lymph node metastasis,tumor diameter,tumor morphology,ring-like enhancement,and peritu-moral brain edema were related to the expressions of miR-4500 and NGF(P<0.05).The bioinformatics website prediction showed that miR-4500 and NGF had binding sites,and the expressions of miR-4500 and NGF mRNA in breast cancer tissues were negatively correlated(r=-0.576,P<0.05).Conclusion The expression of miR-4500 in breast cancer tissue is low,and the expression of NGF is high,which are correlated with the preoperative MR signs in patients,providing a molecu-lar basis for MR signs.
6.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
7.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
8.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
9.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
10.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.

Result Analysis
Print
Save
E-mail