1.Clinical and pathological features of 52 patients with glomerulonephritis with dominant C3
Jinying WEI ; Yao HUANG ; Shuguang YUAN ; Xiaojun CHEN ; Xiao FU ; Zheng LI ; Ying LI ; Lin SUN ; Hong LIU ; Xuejing ZHU
Journal of Central South University(Medical Sciences) 2024;49(1):75-83
Objective:With the in-depth study of complement dysregulation,glomerulonephritis with dominant C3 has received increasing attention,with a variety of pathologic types and large differences in symptoms and prognosis between pathologic types.This study analyzes the clinical,pathological,and prognostic characteristics of different pathological types of glomerulonephritis with dominant C3,aiming to avoid misdiagnosis and missed diagnoses. Methods:The clinical,pathological,and follow-up data of 52 patients diagnosed as glomerulonephritis with dominant C3 by renal biopsy from June 2013 to October 2022 were retrospectively analyzed.According to the clinical feature and results of pathology,15 patients with post-infectious glomerulonephritis(PIGN)and 37 patients with of non-infectious glomerulonephritis(N-PIGN)were classified.N-PIGN subgroup analysis was performed,and 16 patients were assigned into a C3-alone-deposition group and 21 in a C3-dominant-deposition group,or 27 in a C3 glomerulopathy(C3G)group and 10 in a non-C3 nephropathy(N-C3G)group. Results:The PIGN group had lower creatinine values(84.60 μmol/L vs 179.62 μmol/L,P= 0.001),lower complement C3 values(0.36 g/L vs 0.74 g/L,P<0.001)at biopsy,and less severe pathological chronic lesions compared with the N-PIGN group.In the N-PIGN subgroup analysis,the C3-dominant-deposition group had higher creatinine values(235.30 μmol/L vs 106.70 μmol/L,P=0.004)and higher 24-hour urine protein values(4 025.62 mg vs 1 981.11 mg,P=0.037)than the C3-alone-deposition group.The prognosis of kidney in the PIGN group(P=0.049),the C3-alone-deposition group(P=0.017),and the C3G group(P=0.018)was better than that in the N-PIGN group,the C3-dominant-deposition group,and the N-C3G group,respectively. Conclusion:Glomerulonephritis with dominant C3 covers a variety of pathological types,and PIGN needs to be excluded before diagnosing C3G because of considerable overlap with atypical PIGN and C3G;in addition,the deposition of C1q complement under fluorescence microscope may indicate poor renal prognosis,and relevant diagnosis,treatment,and follow-up should be strengthened.
2.Construction and Validation of Risk Prediction Model for Gastrointestinal Bleeding After Cardiopulmonary Bypass Heart Surgery
Lin LI ; Xuejing WANG ; Wenxian WU ; Shuyan WU ; Xueyan WANG ; Meixia GUO ; Huanhuan LI
Chinese Circulation Journal 2024;39(8):800-805
Objectives:To establish a risk prediction model for gastrointestinal bleeding after cardiopulmonary bypass heart surgery,and to verify the prediction efficacy. Methods:A total of 1 002 patients who underwent cardiopulmonary bypass heart surgery in the department of cardiac great vascular surgery of our hospital from January 2019 to November 2023 were collected by convenient sampling method.They were divided into gastrointestinal bleeding group(n=47)and non-gastrointestinal bleeding group(n=955).Logistic regression analysis was used to establish the risk prediction model,and the area under ROC curve test and Hosmer-Lemeshow χ2 test were used to compare the two groups of data Model prediction effect.Bootstrap method was used for internal validation. Results:The risk prediction model of gastrointestinal bleeding after cardiopulmonary bypass heart surgery included four predictors:time of aortic occlusion(OR=1.021,95%CI:1.012-1.030),history of digestive disease(OR=5.710,95%CI:1.697-19.212),use of intra-aortic balloon counterpulsation(OR=22.180,95%CI:5.870-83.808),and continuous kidney replacement therapy(OR=12.159,95%CI:5.066-29.181).Model formula:Logit(P)=-5.821+0.021×time of aortic occlusion+1.742×history of digestive disease+3.099×whether intra-aortic balloon counterpulsation was used+2.498×whether continuous renal replacement therapy was used.The area under ROC curve was 0.812(95%CI:0.746-0.877),sensitivity was 64.6%,specificity was 85.7%,and Youden index was 0.503.After internal validation by Bootstrap method,the consistency index after correction is 0.813. Conclusions:The risk prediction model constructed in this study cohort has a good auxiliary prediction performance for the occurrence of gastrointestinal bleeding after cardiopulmonary bypass surgery,which is helpful for risk stratification for gastrointestinal bleeding after cardiopulmonary bypass surgery and facilitate clinical decision-making in daily clinical work.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Clinic-pathological characteristics of rare tubulointerstitial diseases.
Kewen SHI ; Shuguang YUAN ; Yao HUANG ; Zheng LI ; Chang WANG ; Hong LIU ; Lin SUN ; Fuyou LIU ; Xuejing ZHU
Journal of Central South University(Medical Sciences) 2022;47(10):1365-1374
OBJECTIVES:
Tubulointerstitial diseases is one of the common causes of renal dysfunction. Some rare pathological types are easy to be misdiagnosed and missedly diagnosed because of their low prevalence and relatively insufficient understanding, which affects the treatment and prognosis of patients. This study aims to explore clinical manifestations and pathological characteristics of several rare tubulointerstitial diseases, and therefore to improve their diagnosis and treatment.
METHODS:
A total of 9 363 patients diagnosed by renal biopsy in the Department of Nephrology, Second Xiangya Hospital, Central South University from November 2011 to September 2021 were selected. Six cases of light chain cast nephropathy (LCCN), 2 cases of light chain proximal tubulopathy (LCPT), 1 case of LCCN with LCPT, 4 cases of genetic tubulointerstitial disease, and 6 cases of non-genetic related tubulointerstitial lesion were screened out, and their clinical manifestations and renal biopsy pathological results were collected, compared, and analyzed.
RESULTS:
Patients with LCCN presented with mild to moderate anemia, microscopic hematuria, and mild to moderate proteinuria. Compared with patients with LCPT, proteinuria and anemia were more prominent in patients with LCCN. Five patients with LCCN and 2 patients with LCPT had elevated serum free kappa light chain. Five patients with LCCN presented clinically with acute kidney injury (AKI). Two patients with LCPT and 1 patient with LCCN and LCPT showed CKD combined with AKI, and 1 LCPT patient presented with typical Fanconi syndrome (FS). Five patients with LCCN, 2 patients with LCPT, and 1 patient with LCCN and LCPT were diagnosed with multiple myeloma. Five patients with LCCN had kappa light chain restriction in tubules on immunofluorescence and a "fractured" protein casts with pale periodic acid-Schiff (PAS) staining on light microscopy. Immunohistochemical staining of 2 LCPT patients showed strongly positive kappa light chain staining in the proximal tubular epithelial cells. And monoclonal light chain crystals in crystalline LCPT and abnormal lysosomes and different morphological inclusion bodies in noncrystalline LCPT were observed under the electron microscope. Six patients with LCCN were mainly treated by chemotherapy. Renal function was deteriorated in 1 patient, was stable in 4 patients, and was improved in 1 patient. Two patients with LCPT improved their renal function after chemotherapy. Four patients with genetic tubulointerstitial disease were clinically presented as CKD, mostly mild proteinuria, with or without microscopic hematuria, and also presented with hyperuricemia, urine glucose under normal blood glucose, anemia, polycystic kidneys. Only 1 case had a clear family history, and the diagnosis was mainly based on renal pathological characteristics and genetic testing. Compared with patients with non-genetic related tubulointerstitial lesion, patients with genetic tubulointerstitial disease had an earlier age of onset, higher blood uric acid, lower Hb and estiated glomemlar fitration (eGFR), and less edema and hypertension. Renal pathology of genetic tubulointerstitial disease presented tubular atrophy and interstitial fibrosis, abnormal tubular dilation, glomerular capsuledilation, and glomerular capillary loop shrinkage. Glomerular dysplasia and varying degrees of glomerular sclerosis were observed. Genetic tubulointerstitial disease patients were mainly treated with enteral dialysis, hypouricemic and hypoglycemic treatment. Two genetic tubulointerstitial disease patients had significantly deteriorated renal function, and 2 patients had stable renal function.
CONCLUSIONS
Patients with AKI or FS, who present serum immunofixation electrophoresis and/or serum free kappa light chain abnormalities, should be alert to LCCN or LCPT. Renal biopsy is a critical detection for diagnosis of LCCN and LCPT. Chemotherapy and stem cell transplantation could delay progression of renal function in patients with LCCN and LCPT. If the non-atrophic area of the renal interstitium presents glomerular capsule dilatation, glomerular capillary loop shrinkage, and abnormal tubular dilatation under the light microscopy, genetic tubulointerstitial disease might be considered, which should be traced to family history and can be diagnosed by genetic testing.
Humans
;
Hematuria
;
Immunoglobulin Light Chains/analysis*
;
Multiple Myeloma
;
Proteinuria
;
Nephritis, Interstitial
;
Acute Kidney Injury
;
Anemia
;
Renal Insufficiency, Chronic
7.Effect of aquatic treadmill training on bilateral abdominal muscle thickness and balance function in stroke patients with hemiplegia
Yanan WANG ; Huilin LIU ; Lin ZHU ; Xuejing DU ; Xiaomin ZHU ; Yuanmin LIU
Chinese Journal of Rehabilitation Theory and Practice 2022;28(5):524-529
ObjectiveTo explore the effect of aquatic treadmill training on abdominal muscle thickness and balance function in patients with hemiplegia after stroke. MethodsFrom March to October, 2021, 60 patients with hemiplegia after stroke were randomly divided into control group (n = 20), suspension group (n = 20) and aquatic treadmill group (n = 20). On the basis of comprehensive rehabilitation training, the control group received treadmill training, the suspension group received skyrail suspension walking training, and the aquatic treadmill group received treadmill training in water, for four weeks. The curative effect was evaluated by musculoskeletal ultrasound with muscle thickness of bilateral external oblique, internal oblique and transverse abdominal muscles. And they were assessed with Postural Assessment Scale for Stroke Patient (PASS) and Timed 'Up & Go' Test (TUGT) before and after treatment. ResultsAfter treatment, the thickness of external oblique and internal oblique muscles on the unaffected side, the PASS score and the TUGT time improved in all the three groups (|t| > 2.135, P < 0.05); while the thickness of external oblique, internal oblique and transverse abdominal muscles in the aquatic treadmill training group increased (|t| > 5.567, P < 0.001). The PASS score, the TUGT time, and the thickness of external oblique and internal oblique muscles on the affected side improved more in the aquatic treadmill training group than in the control group and the suspension group (P < 0.05). ConclusionThe aquatic treadmill training is more effective in strenghthening abdominal muscle to improve balance function.
8.Analysis of fusion gene expression in acute myeloid leukemia
Qi YAN ; Yani LIN ; Xianqi HUANG ; Lingzhi QIAN ; Jingting MA ; Hong ZHANG ; Long CHEN ; Xuejing CHEN ; Yingchang MI ; Kun RU
Chinese Journal of Hematology 2021;42(6):480-486
Objective:To analyze the genetic landscape of multiple fusion genes in patients with de novo acute myeloid leukemia (AML) and investigate the characteristics of immunophenotypes and mutations.Methods:The results of multiple fusion genes from 4192 patients with de novo AML were retrospectively analyzed from 2016 to 2020. In addition, the immunophenotypical data and the mutational results from high-through put method were statistically investigated and correlated as well.Results:①Among the 52 targets, 29 different types of fusion genes were detected in 1948 patients (46.47%) with AML, which demonstrated an "exponential distribution" . ② As the age increased, the number of patients with fusion gene increased first and then decreased gradually. The total incidence rate of fusion genes and MLL rearrangment in children were significantly higher than those in adults (69.18% vs 44.76%, 15.35% vs 8.36%) . ③The mutations involving FLT3 and RAS signaling pathway contributed most in patients with MLL rearrangment. ④No specific immunophenotypic characteristics were found in AML patients with MLL or NUP98 rearrangements. Conclusion:Nearly half of AML patients were accompanied by specific fusion gene expression, the proportions of different fusion genes in pediatric and adults patients were different by multiple PCR. The gene mutations and immunophenotype of these AML patients have certain rules.
9.Clinical significance of Mtype phospholipase A2 receptor and thrombospondin Type 1 domaincontaining 7A in primary membranous nephropathy.
Zailiang GONG ; Shuguang YUAN ; Xuejing ZHU ; Youliang WANG ; Fang YU ; Danyi YANG ; Xiangqing XU ; Hong LIU ; Jun LI ; Lin SUN
Journal of Central South University(Medical Sciences) 2020;45(6):693-700
OBJECTIVES:
To evaluate the value of thrombospond in Type I domain-containing 7A (THSD7A) and M-type phospholipase A2 receptor (PLA2R) in primary membranous nephropathy (PMN) and to explore the relationship between their antibody levels and prognosis.
METHODS:
Renal tissues in 128 patients with membranous nephropathy in the Second Xiangya Hospital of Central South University were collected from February 2015 to August 2017, including 108 patients with primary membranous nephropathy (PMN group) and 20 patients with secondary membranous nephropathy (SMN) (SMN group). Indirect immunofluorescence method was used to detect the expression of PLA2R antigen in kidney tissues,and the glomerular expression of THSD7A antigen was examined by immunohistochemistry and indirect immunofluorescence. The serum levels of anti-PLA2R antibodies and THSD7A antibodies were also detected by ELISA. According to the results of PMN examination,the patients were also divided into a PLA2R-related membranous nephropathy group and a THSD7A-related membranous nephropathy group.
RESULTS:
The positive rate of PLA2R in the renal tissues in the PMN group was higher than that in the SMN group (78% in the PMN group, 35% in the SMN group, <0.01),while the positive rate of anti-PLA2R antibody in the PMN group was also higher than that in the SMN group (50% in the PMN group, 25% in the SMN group, <0.05).The serum level of anti-PLA2R antibody was positively correlated with 24 h urine protein (=0.254, <0.05) and negatively correlated with serum albumin (=-0.236, <0.05). The expression of THSD7A was positive in glomeruli in 7 cases of the PMN group (6%) by immuno-histochemistry, and which was positive in 1case of the SMN group (5%).The serum levels of anti-THSD7A antibody in the PMN group were higher than those in the SMN group [(0.49±0.26) pg/mL in the PMN group,(0.34±0.27) pg/mL in the SMN group, <0.05]. There was no difference in the clinical characteristics between the PLA2R-related membranous nephropathy group and the THSD7A-related membranous nephropathy group.
CONCLUSIONS
PLA2R and THSD7A are the target antigen of PMN, and the associated autoantibodies are helpful for the differential diagnosis of PMN. The anti-PLA2R antibody levels can reflect the severity of the disease and evaluate the effect of treatment. The incidence of THSD7A membranous nephropathy is low, and monitoring the serum anti-THSD7A antibody levels can assess patients' condition and predict disease outcome.
Autoantibodies
;
Glomerulonephritis, Membranous
;
Humans
;
Immunohistochemistry
;
Receptors, Phospholipase A2
;
Thrombospondins
10.Two cases of Type Ⅲ collagen glomerulopathy and literature review.
Fang YU ; Xuejing ZHU ; Shuguang YUAN ; Zailiang GONG ; Xiangqing XU ; Hong LIU ; Jun LI ; Lin SUN ; Fuyou LIU
Journal of Central South University(Medical Sciences) 2020;45(7):869-873
In this paper, 2 cases of collagen Type Ⅲ glomerulopathy were analyzed. The clinical manifestations mainly included nephrotic syndrome, proteinuria, hypertension and renal dysfunction. One patient showed that the complement factor H-related protein 5 (CFHR5) gene was likely a disease-causing mutation. The pathological examination of renal tissues showed hyperplasia of mesangial matrix, sub-endothelial insertion, and double-track formation. Immunohistochemistry of Type III collagen was positive. Electron microscopy revealed that massive collagen fibers (40-70 nm in diameter) deposited in the mesangial matrix and basement membrane. As for the follow-up results, the normal renal function had kept steady and the proteinuria was moderate in 1 case treated with angiotensin Ⅱ receptor blocker. Due to other system disease, another case developed into acute kidney injury and then received hemodialysis. The clinical manifestations of collagen Type Ⅲ glomerulopathy was atypical, the light microscope pathological features were various, and the disease was mainly diagnosed by electron microscopy and immunohistochemistry.
Collagen Type III
;
genetics
;
Glomerular Mesangium
;
Humans
;
Kidney Diseases
;
Kidney Glomerulus
;
Proteinuria

Result Analysis
Print
Save
E-mail