1.An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatment
Haeun MOON ; Jaewon KOH ; Veerasathpurush ALLAREDDY ; Phimon ATSAWASUWAN ; Min Kyeong LEE ; Kyungmin Clara LEE
The Korean Journal of Orthodontics 2025;55(3):202-211
Objective:
To propose the utilization of virtual tooth models (VTMs) created by combining tooth root data from cone-beam computed tomography (CBCT) and crown data gathered through intraoral scanning to assess inter-root distance and angulation during orthodontic treatment when repeated radiographic monitoring becomes necessary.
Methods:
Patients with planned dental implant placement in edentulous areas during or after orthodontic treatment and who underwent intraoral and CBCT scans at the pretreatment and posttreatment stages were selected. Tooth models were fabricated by merging intraorally scanned crowns with the corresponding CBCT-scanned roots from the pretreatment. Tooth positions posttreatment was estimated by integrating models into posttreatment intraoral scans. Moreover, the actual positions were obtained from posttreatment CBCTs. Discrepancies in the estimated and actual tooth positions, including interradicular distances and inter-root angulations, were compared.
Results:
The minimum inter-radicular distance between two adjacent teeth demonstrated no significant difference between the estimated and actual tooth positions. The difference in inter-root angulation was not statistically significant. Most interradicular distances measured at each landmark revealed no significant differences between the estimated and actual tooth positions, except at the buccolingual midpoint of the cemento-enamel junction, where a slight discrepancy was observed.
Conclusions
The tooth position of VTMs demonstrated clinically acceptable accuracy compared to CBCT scans. Additionally, VTMs can benefit both clinicians and patients by enabling accurate assessment of the inter-radicular space for dental implant placement without repeated CBCT scans.
2.An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatment
Haeun MOON ; Jaewon KOH ; Veerasathpurush ALLAREDDY ; Phimon ATSAWASUWAN ; Min Kyeong LEE ; Kyungmin Clara LEE
The Korean Journal of Orthodontics 2025;55(3):202-211
Objective:
To propose the utilization of virtual tooth models (VTMs) created by combining tooth root data from cone-beam computed tomography (CBCT) and crown data gathered through intraoral scanning to assess inter-root distance and angulation during orthodontic treatment when repeated radiographic monitoring becomes necessary.
Methods:
Patients with planned dental implant placement in edentulous areas during or after orthodontic treatment and who underwent intraoral and CBCT scans at the pretreatment and posttreatment stages were selected. Tooth models were fabricated by merging intraorally scanned crowns with the corresponding CBCT-scanned roots from the pretreatment. Tooth positions posttreatment was estimated by integrating models into posttreatment intraoral scans. Moreover, the actual positions were obtained from posttreatment CBCTs. Discrepancies in the estimated and actual tooth positions, including interradicular distances and inter-root angulations, were compared.
Results:
The minimum inter-radicular distance between two adjacent teeth demonstrated no significant difference between the estimated and actual tooth positions. The difference in inter-root angulation was not statistically significant. Most interradicular distances measured at each landmark revealed no significant differences between the estimated and actual tooth positions, except at the buccolingual midpoint of the cemento-enamel junction, where a slight discrepancy was observed.
Conclusions
The tooth position of VTMs demonstrated clinically acceptable accuracy compared to CBCT scans. Additionally, VTMs can benefit both clinicians and patients by enabling accurate assessment of the inter-radicular space for dental implant placement without repeated CBCT scans.
3.An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatment
Haeun MOON ; Jaewon KOH ; Veerasathpurush ALLAREDDY ; Phimon ATSAWASUWAN ; Min Kyeong LEE ; Kyungmin Clara LEE
The Korean Journal of Orthodontics 2025;55(3):202-211
Objective:
To propose the utilization of virtual tooth models (VTMs) created by combining tooth root data from cone-beam computed tomography (CBCT) and crown data gathered through intraoral scanning to assess inter-root distance and angulation during orthodontic treatment when repeated radiographic monitoring becomes necessary.
Methods:
Patients with planned dental implant placement in edentulous areas during or after orthodontic treatment and who underwent intraoral and CBCT scans at the pretreatment and posttreatment stages were selected. Tooth models were fabricated by merging intraorally scanned crowns with the corresponding CBCT-scanned roots from the pretreatment. Tooth positions posttreatment was estimated by integrating models into posttreatment intraoral scans. Moreover, the actual positions were obtained from posttreatment CBCTs. Discrepancies in the estimated and actual tooth positions, including interradicular distances and inter-root angulations, were compared.
Results:
The minimum inter-radicular distance between two adjacent teeth demonstrated no significant difference between the estimated and actual tooth positions. The difference in inter-root angulation was not statistically significant. Most interradicular distances measured at each landmark revealed no significant differences between the estimated and actual tooth positions, except at the buccolingual midpoint of the cemento-enamel junction, where a slight discrepancy was observed.
Conclusions
The tooth position of VTMs demonstrated clinically acceptable accuracy compared to CBCT scans. Additionally, VTMs can benefit both clinicians and patients by enabling accurate assessment of the inter-radicular space for dental implant placement without repeated CBCT scans.
4.An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatment
Haeun MOON ; Jaewon KOH ; Veerasathpurush ALLAREDDY ; Phimon ATSAWASUWAN ; Min Kyeong LEE ; Kyungmin Clara LEE
The Korean Journal of Orthodontics 2025;55(3):202-211
Objective:
To propose the utilization of virtual tooth models (VTMs) created by combining tooth root data from cone-beam computed tomography (CBCT) and crown data gathered through intraoral scanning to assess inter-root distance and angulation during orthodontic treatment when repeated radiographic monitoring becomes necessary.
Methods:
Patients with planned dental implant placement in edentulous areas during or after orthodontic treatment and who underwent intraoral and CBCT scans at the pretreatment and posttreatment stages were selected. Tooth models were fabricated by merging intraorally scanned crowns with the corresponding CBCT-scanned roots from the pretreatment. Tooth positions posttreatment was estimated by integrating models into posttreatment intraoral scans. Moreover, the actual positions were obtained from posttreatment CBCTs. Discrepancies in the estimated and actual tooth positions, including interradicular distances and inter-root angulations, were compared.
Results:
The minimum inter-radicular distance between two adjacent teeth demonstrated no significant difference between the estimated and actual tooth positions. The difference in inter-root angulation was not statistically significant. Most interradicular distances measured at each landmark revealed no significant differences between the estimated and actual tooth positions, except at the buccolingual midpoint of the cemento-enamel junction, where a slight discrepancy was observed.
Conclusions
The tooth position of VTMs demonstrated clinically acceptable accuracy compared to CBCT scans. Additionally, VTMs can benefit both clinicians and patients by enabling accurate assessment of the inter-radicular space for dental implant placement without repeated CBCT scans.
5.An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatment
Haeun MOON ; Jaewon KOH ; Veerasathpurush ALLAREDDY ; Phimon ATSAWASUWAN ; Min Kyeong LEE ; Kyungmin Clara LEE
The Korean Journal of Orthodontics 2025;55(3):202-211
Objective:
To propose the utilization of virtual tooth models (VTMs) created by combining tooth root data from cone-beam computed tomography (CBCT) and crown data gathered through intraoral scanning to assess inter-root distance and angulation during orthodontic treatment when repeated radiographic monitoring becomes necessary.
Methods:
Patients with planned dental implant placement in edentulous areas during or after orthodontic treatment and who underwent intraoral and CBCT scans at the pretreatment and posttreatment stages were selected. Tooth models were fabricated by merging intraorally scanned crowns with the corresponding CBCT-scanned roots from the pretreatment. Tooth positions posttreatment was estimated by integrating models into posttreatment intraoral scans. Moreover, the actual positions were obtained from posttreatment CBCTs. Discrepancies in the estimated and actual tooth positions, including interradicular distances and inter-root angulations, were compared.
Results:
The minimum inter-radicular distance between two adjacent teeth demonstrated no significant difference between the estimated and actual tooth positions. The difference in inter-root angulation was not statistically significant. Most interradicular distances measured at each landmark revealed no significant differences between the estimated and actual tooth positions, except at the buccolingual midpoint of the cemento-enamel junction, where a slight discrepancy was observed.
Conclusions
The tooth position of VTMs demonstrated clinically acceptable accuracy compared to CBCT scans. Additionally, VTMs can benefit both clinicians and patients by enabling accurate assessment of the inter-radicular space for dental implant placement without repeated CBCT scans.
6.Difference in Baseline Antimicrobial Prescription Patterns of Hospitals According to Participation in the National Antimicrobial Monitoring and Feedback System in Korea
Jihye SHIN ; Ji Young PARK ; Jungmi CHAE ; Hyung-Sook KIM ; Song Mi MOON ; Eunjeong HEO ; Se Yoon PARK ; Dong Min SEO ; Ha-Jin CHUN ; Yong Chan KIM ; Myung Jin LEE ; Kyungmin HUH ; Hyo Jung PARK ; I Ji YUN ; Su Jin JEONG ; Jun Yong CHOI ; Dong-Sook KIM ; Bongyoung KIM ;
Journal of Korean Medical Science 2024;39(29):e216-
This study aimed to evaluate the differences in the baseline characteristics and patterns of antibiotic usage among hospitals based on their participation in the Korea National Antimicrobial Use Analysis System (KONAS). We obtained claims data from the National Health Insurance for inpatients admitted to all secondary- and tertiary-care hospitals between January 2020 and December 2021 in Korea. 15.9% (58/395) of hospitals were KONAS participants, among which the proportion of hospitals with > 900 beds (31.0% vs.2.6%, P < 0.001) and tertiary care (50.0% vs. 5.2%, P < 0.001) was higher than that among non-participants. The consumption of antibiotics targeting antimicrobial-resistant gram positive bacteria (33.7 vs. 27.1 days of therapy [DOT]/1,000 patient-days, P = 0.019) and antibiotics predominantly used for resistant gram-negative bacteria (4.8 vs. 3.7 DOT/1,000 patient-days, P = 0.034) was higher in KONAS-participating versus -non-participating hospitals. The current KONAS data do not fully represent all secondary- and tertiary-care hospitals in Korea; thus, the KONAS results should be interpreted with caution.
7.Nationwide Target Trial Emulation Evaluating the Clinical Effectiveness of Oral Antivirals for COVID-19 in Korea
Kyungmin HUH ; Youngji JO ; Gi Hwan BAE ; Hyejin JOO ; Munkhzul RADNAABAATAR ; Hyungmin LEE ; Jungyeon KIM ; Dong-Hwi KIM ; Min-Gyu YOO ; Il Uk JO ; Poong Hoon LEE ; Geun Woo LEE ; Hee Sun JUNG ; Jaehun JUNG
Journal of Korean Medical Science 2024;39(42):e272-
Background:
Despite the proven effectiveness of oral antivirals against severe acute respiratory syndrome coronavirus 2 in randomized trials, their clinical reevaluation is vital in the context of widespread immunity and milder prevalent variants. This study aimed to assess the effectiveness of oral antivirals for coronavirus disease 2019 (COVID-19).
Methods:
This retrospective cohort study utilized a target trial emulation framework to analyze patients with COVID-19 aged 60+ from January to December 2022. Data were obtained from the Korea Disease Control and Prevention Agency and Health Insurance Review and Assessment Service. The study involved 957,036 patients treated with nirmatrelvir/ritonavir and 243,360 treated with molnupiravir, each compared with the matched control groups. Primary outcome was progression to critical COVID-19 requiring advanced respiratory support. Secondary outcomes included progression to severe COVID-19, need for supplemental oxygen, and death within 30 days of the onset of COVID-19.Number needed to treat (NNT) derived from the absolute risk reduction.
Results:
Nirmatrelvir/ritonavir was significantly associated with a reduced risk of severe (adjusted odds ratio [aOR], 0.823; 95% confidence interval [CI], 0.803–0.843), critical (aOR, 0.560; 95% CI, 0.503–0.624), and fatal COVID-19 (aOR, 0.694; 95% CI, 0.647–0.744).Similarly, molnupiravir reduced the risk of severe (aOR, 0.895; 95% CI, 0.856–0.937), critical (aOR, 0.672; 95% CI, 0.559–0.807), and fatal cases (aOR, 0.679; 95% CI, 0.592–0.779).NNTs for nirmatrelvir/ritonavir were 203.71 (severe), 1,230.12 (critical), and 691.50 (death);for molnupiravir, they were 352.70 (severe), 1,398.62 (critical), and 862.98 (death). Higher effectiveness was associated with older adults, unvaccinated individuals, and the late pandemic phase.
Conclusion
Nirmatrelvir/ritonavir and molnupiravir are effective in preventing progression to severe disease in elderly adults with COVID-19.
8.Impact of Childhood Maltreatment on Cognitive Function and Its Relationship With Emotion Regulation in Young Adults
Min Seok KIM ; Kyungmin KIM ; Jihyun NAM ; Seung Jae LEE ; Sang Won LEE
Journal of the Korean Academy of Child and Adolescent Psychiatry 2024;35(3):155-162
Objectives:
Childhood maltreatment can negatively impact cognitive development, including executive function, working memory, and processing speed. This study investigated the impact of childhood maltreatment on cognitive function in young adults using various measurements, including computerized tests, and their relationship with emotional dysregulation.
Methods:
We recruited 149 healthy individuals with and without maltreatment experiences and used the Wechsler Adult Intelligence Scale IV (WAIS-IV) and a computerized battery to analyze cognitive function.
Results:
Both the WAIS-IV and computerized tests revealed that individuals with a history of childhood maltreatment had decreased cognitive function, especially in terms of working memory and processing speed. These individuals tended to employ maladaptive emotion regulation strategies. Among cognitive functions, working memory is negatively related to maladaptive emotion regulation strategies such as catastrophizing.
Conclusion
This study highlights the effects of childhood maltreatment on cognitive function in young adulthood. Moreover, the study suggests clinical implications of cognitive interventions for improving emotion regulation and cognitive function in individuals with a history of childhood maltreatment.
9.Identification of Viral Particles in Infant Cutaneous Tissue in Cases of Covid Toes
Kyungmin KIM ; Seungjin SON ; Tae-Jong KANG ; Dongkyun HONG ; Kyung Eun JUNG ; Jin-Man KIM ; Jung-Min SHIN ; Jin PARK ; Young LEE
Korean Journal of Dermatology 2024;62(7):412-417
Coronavirus disease 2019 (COVID-19), a multi-organ disease impacting the respiratory system and various organs, has recently been linked to diverse cutaneous manifestations. COVID toes, a cutaneous sign of COVID-19 infection, is relatively common in children and young adults, although its clear association with COVID-19 has not been widely reported. This report presents the case of a 1-year-old infant with COVID toes. The patient exhibited violaceous discoloration in the distal toes. Further, the patient exhibited no symptoms of COVID-19 infection and the enzyme-linked immunosorbent assay was negative for severe acute respiratory syndrome coronavirus 2(SARS-CoV-2); therefore, the patient was initially diagnosed with frostbite. However, the infant’s condition deteriorated despite treatment with nonsteroidal anti-inflammatory drugs and a warm-water bath. After a skin biopsy and serum SARS-CoV-2 test, the patient was diagnosed with COVID toes and treated with systemic steroids, photobiomodulation therapy, and dressing. This case underscores the importance of recognizing chilblain-like lesions in pediatric patients during the COVID-19 pandemic, emphasizing the need for awareness of COVID toes among healthcare professionals.
10.Loss of Neutralizing Activity of Tixagevimab/Cilgavimab (Evusheld™) Against Omicron BN.1, a Dominant Circulating Strain Following BA.5During the Seventh Domestic Outbreak in Korea in Early 2023
Jinyoung YANG ; Seokhwan HYEON ; Jin Yang BAEK ; Min Seo KANG ; Keon Young LEE ; Young Ho LEE ; Kyungmin HUH ; Sun Young CHO ; Cheol-In KANG ; Doo Ryeon CHUNG ; Kyong Ran PECK ; Gunho WON ; Hye Won LEE ; Kwangwook KIM ; Insu HWANG ; So Yeon LEE ; Byung Chul KIM ; Yoo-kyoung LEE ; Jae-Hoon KO
Journal of Korean Medical Science 2023;38(27):e205-
Tixagevimab/cilgavimab is a monoclonal antibody used to prevent coronavirus disease 2019 among immunocompromised hosts and maintained neutralizing activity against early omicron variants. Omicron BN.1 became a dominant circulating strain in Korea early 2023, but its susceptibility to tixagevimab/cilgavimab is unclear. We conducted plaque reduction neutralization test (PRNT) against BN.1 in a prospective cohort (14 patients and 30 specimens). BN.1 PRNT was conducted for one- and three-months after tixagevimab/ cilgavimab administration and the average PRNT ND 50 of each point was lower than the positive cut-off value of 20 (12.9 ± 4.5 and 13.2 ± 4.2, respectively, P = 0.825). In the paired analyses, tixagevimab/cilgavimab-administered sera could not actively neutralize BN.1 (PRNT ND 50 11.5 ± 2.9, P = 0.001), compared with the reserved activity against BA.5 (ND 50 310.5 ± 180.4). Unlike virus-like particle assay, tixagevimab/cilgavimab was not active against BN.1 in neutralizing assay, and would not be effective in the present predominance of BA.2.75 sublineages.

Result Analysis
Print
Save
E-mail