1.Changing Gadolinium-Based Contrast Agents to Prevent Recurrent Acute Adverse Drug Reactions: 6-Year Cohort Study Using Propensity Score Matching
Min Woo HAN ; Chong Hyun SUH ; Pyeong Hwa KIM ; Seonok KIM ; Ah Young KIM ; Kyung-Hyun DO ; Jeong Hyun LEE ; Dong-Il GWON ; Ah Young JUNG ; Choong Wook LEE
Korean Journal of Radiology 2025;26(2):204-204
2.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
5.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
6.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
7.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Comparison of Finasteride and Dutasteride on Risk of Prostate Cancer in Patients with Benign Prostatic Hyperplasia: A Pooled Analysis of 15Real-world Databases
Dae Yul YANG ; Won-Woo SEO ; Rae Woong PARK ; Sang Youl RHEE ; Jae Myung CHA ; Yoon Soo HAH ; Chang Won JEONG ; Kyung-Jin KIM ; Hyeon-Jong YANG ; Do Kyung KIM ; Ji Yong HA
The World Journal of Men's Health 2025;43(1):188-196
Purpose:
Finasteride and dutasteride are used to treat benign prostatic hyperplasia (BPH) and reduce the risk of developing prostate cancer. Finasteride blocks only the type 2 form of 5-alpha-reductase, whereas dutasteride blocks both type 1 and 2 forms of the enzyme. Previous studies suggest the possibility that dutasteride may be superior to finasteride in preventing prostate cancer. We directly compared the effects of finasteride and dutasteride on the risk of prostate cancer in patients with BPH using a pooled analysis of 15 real-world databases.
Materials and Methods:
We conducted a multicenter, cohort study of new-users of finasteride and dutasteride. We include patients who were prescribed 5 mg finasteride or dutasteride for the first time to treat BPH and had at least 180 days of prescription. We excluded patients with a history of prostate cancer or a prostate-specific antigen level ≥ 4 ng/mL before the study drug prescription. Cox regression analysis was performed to examine the hazard ratio (HR) for prostate cancer after propensity score (PS) matching.
Results:
A total of 8,284 patients of new-users of finasteride and 8,670 patients of new-users of dutasteride were included across the 15 databases. In the overall population, compared to dutasteride, finasteride was associated with a lower risk of prostate cancer in both on-treatment and intent-to-treat time-at-risk periods. After 1:1 PS matching, 4,897 patients using finasteride and 4,897 patients using dutasteride were enrolled in the present study. No significant differences were observed for risk of prostate cancer between finasteride and dutasteride both on-treatment (HR=0.66, 95% confidence interval [CI]: 0.44–1.00; p=0.051) and intent-to-treat time-at-risk periods (HR=0.87, 95% CI: 0.67–1.14; p=0.310).
Conclusions
Using real-world databases, the present study demonstrated that dutasteride was not associated with a lower risk of prostate cancer than finasteride in patients with BPH.
10.Reduction of Low-Density Lipoprotein Cholesterol by Mesenchymal Stem Cells in a Mouse Model of Exogenous Cushing’s Syndrome
Yu-Hee KIM ; Seonghee JEONG ; Kyung-Ah CHO ; So-Youn WOO ; Seung-Ho HAN ; Kyung-Ha RYU
Tissue Engineering and Regenerative Medicine 2025;22(2):237-248
BACKGROUND:
Exogenous Cushing’s syndrome, which results from prolonged glucocorticoid treatment, is associated with metabolic abnormalities. Previously, we reported the inhibitory effect of tonsil-derived mesenchymal stem cell conditioned medium (T-MSC CM) on glucocorticoid signal transduction. In this study, we investigated the therapeutic efficacy of T-MSCs in a mouse model of exogenous Cushing’s syndrome.
METHODS:
Exogenous Cushing’s syndrome model mice was generated by corticosterone administration in the drinking water for 5 weeks, and T-MSCs were injected intraperitoneally twice during the third week. Serum lipid profiles were measured using a chemistry analyzer. HepG2 cells were treated with dexamethasone and co-cultured with T-MSCs.Expression levels of genes involved in cholesterol metabolism were examined using real-time PCR. Low-density lipoprotein receptor (LDLR) protein levels were determined using western blotting and immunohistochemistry. Liver RNA extracted from the CORT and CORT ? MSC mouse groups was used for transcriptome sequencing analysis and protein– protein interaction analysis.
RESULTS:
Weight reduction and improvements in dyslipidemia by T-MSC administration were observed only in female mice. T-MSCs reduce circulating LDL cholesterol levels by downregulating liver X receptor a (LXRa) and inducible degrader of LDLR (IDOL) expression, thereby stabilizing LDLRs in the liver. Transcriptome analysis of liver tissue revealed pathways that are regulated by T-MSCs administration.
CONCLUSION
Administration of MSCs to female mice receiving chronic corticosterone treatment reduced the circulating LDL cholesterol level by downregulating the LXRa–IDOL axis in hepatocytes. These results suggest that T-MSCs may offer a novel therapeutic strategy for managing exogenous Cushing’s syndrome by regulating cholesterol metabolism.

Result Analysis
Print
Save
E-mail