1.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
		                        		
		                        			 Purpose:
		                        			The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.  
		                        		
		                        			Materials and Methods:
		                        			Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).  
		                        		
		                        			Results:
		                        			A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).  
		                        		
		                        			Conclusion
		                        			The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin. 
		                        		
		                        		
		                        		
		                        	
2.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
		                        		
		                        			 Purpose:
		                        			The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.  
		                        		
		                        			Materials and Methods:
		                        			Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).  
		                        		
		                        			Results:
		                        			A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).  
		                        		
		                        			Conclusion
		                        			The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin. 
		                        		
		                        		
		                        		
		                        	
3.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
		                        		
		                        			 PURPOSE:
		                        			The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test. 
		                        		
		                        			RESULTS:
		                        			Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group. 
		                        		
		                        			CONCLUSION
		                        			This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment. 
		                        		
		                        		
		                        		
		                        	
4.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
		                        		
		                        		
		                        		
		                        	
5.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
		                        		
		                        			 PURPOSE:
		                        			The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test. 
		                        		
		                        			RESULTS:
		                        			Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group. 
		                        		
		                        			CONCLUSION
		                        			This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment. 
		                        		
		                        		
		                        		
		                        	
6.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
		                        		
		                        			 PURPOSE:
		                        			The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years. 
		                        		
		                        			MATERIALS AND METHODS:
		                        			This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test. 
		                        		
		                        			RESULTS:
		                        			Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group. 
		                        		
		                        			CONCLUSION
		                        			This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment. 
		                        		
		                        		
		                        		
		                        	
7.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
		                        		
		                        		
		                        		
		                        	
8.Impact of HER2-Low Status on Pathologic Complete Response and Survival Outcome Among Breast Cancer Patients Undergoing Neoadjuvant Chemotherapy
Young Joo LEE ; Tae-Kyung YOO ; Sae Byul LEE ; Il Yong CHUNG ; Hee Jeong KIM ; Beom Seok KO ; Jong Won LEE ; Byung Ho SON ; Sei Hyun AHN ; Hyehyun JEONG ; Jae Ho JUNG ; Jin-Hee AHN ; Kyung Hae JUNG ; Sung-Bae KIM ; Hee Jin LEE ; Gyungyub GONG ; Jisun KIM
Journal of Breast Cancer 2025;28(1):11-22
		                        		
		                        			 Purpose:
		                        			This study analyzed the pathological complete response (pCR) rates, long-term outcomes, and biological features of human epidermal growth factor receptor 2 (HER2)-zero, HER2-low, and HER2-positive breast cancer patients undergoing neoadjuvant treatment. 
		                        		
		                        			Methods:
		                        			This single-center study included 1,667 patients who underwent neoadjuvant chemotherapy from 2008 to 2014. Patients were categorized by HER2 status, and their clinicopathological characteristics, chemotherapy responses, and recurrence-free survival (RFS) rates were analyzed. 
		                        		
		                        			Results:
		                        			Patients with HER2-low tumors were more likely to be older (p = 0.081), have a lower histological grade (p < 0.001), and have hormone receptor (HorR)-positive tumors (p < 0.001). The HER2-positive group exhibited the highest pCR rate (23.3%), followed by the HER2-zero (15.5%) and HER2-low (10.9%) groups. However, the pCR rate did not differ between HER2-low and HER2-zero tumors in the HorR-positive or HorR-negative subgroups.The 5-year RFS rates increased in the following order: HER2-low, HER2-positive, and HER2-zero (80.0%, 77.5%, and 74.5%, respectively) (log-rank test p = 0.017). A significant survival difference between patients with HER2-low and HER2-zero tumors was only identified in HorR-negative tumors (5-year RFS for HER2-low, 74.5% vs. HER2-zero, 66.0%; log-rank test p-value = 0.04). Multivariate survival analysis revealed that achieving a pCR was the most significant factor associated with improved survival (hazard ratio [HR], 4.279; p < 0.001).Compared with HER2-zero, the HRs for HER2-low and HER2-positive tumors were 0.787 (p = 0.042) and 0.728 (p = 0.005), respectively. After excluding patients who received HER2-targeted therapy, patients with HER2-low tumors exhibited better RFS than those with HER2-zero (HR 0.784, p = 0.04), whereas those with HER2-positive tumors exhibited no significant difference compared with those with HER2-low tumors (HR, 0.975; p = 0.953). 
		                        		
		                        			Conclusion
		                        			Patients with HER2-low tumors had no significant difference in pCR rate compared to HER2-zero but showed better survival, especially in HorR-negative tumors.Further investigation into biological differences is warranted. 
		                        		
		                        		
		                        		
		                        	
9.Impact of HER2-Low Status on Pathologic Complete Response and Survival Outcome Among Breast Cancer Patients Undergoing Neoadjuvant Chemotherapy
Young Joo LEE ; Tae-Kyung YOO ; Sae Byul LEE ; Il Yong CHUNG ; Hee Jeong KIM ; Beom Seok KO ; Jong Won LEE ; Byung Ho SON ; Sei Hyun AHN ; Hyehyun JEONG ; Jae Ho JUNG ; Jin-Hee AHN ; Kyung Hae JUNG ; Sung-Bae KIM ; Hee Jin LEE ; Gyungyub GONG ; Jisun KIM
Journal of Breast Cancer 2025;28(1):11-22
		                        		
		                        			 Purpose:
		                        			This study analyzed the pathological complete response (pCR) rates, long-term outcomes, and biological features of human epidermal growth factor receptor 2 (HER2)-zero, HER2-low, and HER2-positive breast cancer patients undergoing neoadjuvant treatment. 
		                        		
		                        			Methods:
		                        			This single-center study included 1,667 patients who underwent neoadjuvant chemotherapy from 2008 to 2014. Patients were categorized by HER2 status, and their clinicopathological characteristics, chemotherapy responses, and recurrence-free survival (RFS) rates were analyzed. 
		                        		
		                        			Results:
		                        			Patients with HER2-low tumors were more likely to be older (p = 0.081), have a lower histological grade (p < 0.001), and have hormone receptor (HorR)-positive tumors (p < 0.001). The HER2-positive group exhibited the highest pCR rate (23.3%), followed by the HER2-zero (15.5%) and HER2-low (10.9%) groups. However, the pCR rate did not differ between HER2-low and HER2-zero tumors in the HorR-positive or HorR-negative subgroups.The 5-year RFS rates increased in the following order: HER2-low, HER2-positive, and HER2-zero (80.0%, 77.5%, and 74.5%, respectively) (log-rank test p = 0.017). A significant survival difference between patients with HER2-low and HER2-zero tumors was only identified in HorR-negative tumors (5-year RFS for HER2-low, 74.5% vs. HER2-zero, 66.0%; log-rank test p-value = 0.04). Multivariate survival analysis revealed that achieving a pCR was the most significant factor associated with improved survival (hazard ratio [HR], 4.279; p < 0.001).Compared with HER2-zero, the HRs for HER2-low and HER2-positive tumors were 0.787 (p = 0.042) and 0.728 (p = 0.005), respectively. After excluding patients who received HER2-targeted therapy, patients with HER2-low tumors exhibited better RFS than those with HER2-zero (HR 0.784, p = 0.04), whereas those with HER2-positive tumors exhibited no significant difference compared with those with HER2-low tumors (HR, 0.975; p = 0.953). 
		                        		
		                        			Conclusion
		                        			Patients with HER2-low tumors had no significant difference in pCR rate compared to HER2-zero but showed better survival, especially in HorR-negative tumors.Further investigation into biological differences is warranted. 
		                        		
		                        		
		                        		
		                        	
10.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
		                        		
		                        			 Purpose:
		                        			The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.  
		                        		
		                        			Materials and Methods:
		                        			Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).  
		                        		
		                        			Results:
		                        			A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).  
		                        		
		                        			Conclusion
		                        			The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail