1.Emergency Physicians’ Experience of Communication About Brain-Death Organ and Tissue Donation
Song Yi PARK ; Hyun KIM ; Kwi Hwa PARK ; Seung Min PARK ; Dong Eun LEE ; Yong Hun JUNG ; Won Joon JEONG ; Kyung Hye PARK
Health Communication 2021;16(1):25-33
Background:
: Emergency physicians are increasingly participating in brain-death organ tissue donation (OTD).It is difficult communication to inform family members about suspected brain-death and potential donor.This study sought to explore the experiences and communication of emergency physicians in brain-death OTD.
Methods:
: This is a qualitative study that interviewed 10 experienced emergency physicians with brain-death OTD and analyzed the data by thematic analysis method.
Results:
: The study revealed 20 subthemes and 5 themes; 1) Families who are invited to donate organs make decisions after long periods of consideration by the entire family, 2) It is uncomfortable to recommend organ donation, 3) Explaining and obtaining consent is ‘the hardest job’ for the attending physician, 4) The way the attending physician does ‘the hardest job’ is by explaining, 5) Passively solicit donation.
Conclusion
: The experienced emergency physicians with brain-death OTD were using methods of communication to understand and sympathized with the family members and had abundant experiences. The findings of this study will help inexperienced emergency physicians with brain-death OTD.
2.Arteriovenous Malformation of the Distal Ileum in a 14-Year-Old Girl with Recurrent Abdominal Pain: A Case Report
Hyein KANG ; Eun Sun LEE ; Hee Sung KIM ; Mi Kyung KIM ; Kwi Won PARK ; Dae Yong YI ; Byung Ihn CHOI ; Jong Beum LEE ; Hyun Jeong PARK
Journal of the Korean Radiological Society 2018;78(4):295-298
Arteriovenous malformation (AVM) is a lesion involving a high-flow vascular malformation, which is one of the causes of massive gastrointestinal bleeding. In the pediatric population, AVM is quite rare in the gastrointestinal tract, and the most common primary site is the colon. A small bowel is a rare primary site of AVM, and only 1 case has been reported in Korea. Here, we report on a case of AVM found in the distal ileum of a 14-year-old girl who complained about recurrent lower abdominal pain only without a gastrointestinal hemorrhage. In the previous research literature, a small bowel AVM can be diagnosed through detecting the existence of an enhancing nidus of the intestinal wall at the arterial phase, accompanied by an early draining vein as it appeared on a dynamic contrast-enhanced abdominal computed tomography. In our case, the pathologically confirmed AVM of the distal ileum showed a dot-like enhancement within the thick low-attenuating submucosal layer of the terminal ileum.
3.Acid etching of glass-infiltrated zirconia and its biological response.
Van Thi VU ; Gye Jeong OH ; Kwi Dug YUN ; Hyun Pil LIM ; Ji Won KIM ; Thao Phuong Thi NGUYEN ; Sang Won PARK
The Journal of Advanced Prosthodontics 2017;9(2):104-109
PURPOSE: The purpose of this study was to evaluate the influence of acid etching treatment on surface characteristics and biological response of glass-infiltrated zirconia. MATERIALS AND METHODS: A hundred zirconia specimens were divided into four groups depending on surface treatments: untreated zirconia (group Z); acid-etched zirconia (group ZE); glass-infiltrated zirconia (group ZG); and glass-infiltrated and acid-etched zirconia (group ZGE). Surface roughness, surface topography, surface morphology, and Vickers hardness of specimens were evaluated. For biological response test, MC3T3-E1 cell attachment and proliferation on surface of the specimens were examined. The data were statistically analyzed using one-way ANOVA and Tukey's HSD test at a significance level of 0.05. RESULTS: Group ZGE showed the highest surface roughness (Ra = 1.54 µm) compared with other groups (P < .05). Meanwhile, the hardness of group Z was significantly higher than those of other groups (P < .05). Cell attachment and cell proliferation were significantly higher in group ZGE (P < .05). CONCLUSION: We concluded that effective surface roughness on zirconia could be made by acid etching treatment after glass infiltration. This surface showed significantly enhanced osteoblast cell response.
Cell Proliferation
;
Glass
;
Hardness
;
Osteoblasts
4.Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.
Min Kyung JI ; Ji Hee PARK ; Sang Won PARK ; Kwi Dug YUN ; Gye Jeong OH ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2015;7(4):271-277
PURPOSE: This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS: Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau(R)Zirconia and ZENOSTAR(R)ZR translucent) and lithium disilicate glass ceramic (IPS e.max(R)press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS: The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max(R)press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION: The lithium disilicate glass ceramic crown (IPS e.max(R)press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR(R)ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max(R)press) had overextended margins.
Bicuspid
;
Ceramics
;
Computer-Aided Design*
;
Crowns*
;
Glass
;
Lithium*
;
Resin Cements
;
Shoulder
;
Tooth
5.Comparison of Clinical Outcomes Associated with Pull-Type and Introducer-Type Percutaneous Endoscopic Gastrostomies.
Sin Won LEE ; Jeong Hoon LEE ; Hyungjin CHO ; Yeonjung HA ; Hyun LIM ; Ji Yong AHN ; Kwi Sook CHOI ; Do Hoon KIM ; Kee Don CHOI ; Ho June SONG ; Gin Hyug LEE ; Hwoon Yong JUNG ; Jin Ho KIM
Clinical Endoscopy 2014;47(6):530-537
BACKGROUND/AIMS: Percutaneous endoscopic gastrostomy (PEG) is a method of providing enteral nutrition using endoscopy. The PEG techniques differ according to the insertion method, and include the pull type, push type, and introducer type. The aim of this study was to compare the clinical outcomes associated with the pull-type and introducer-type PEG insertion techniques, which included the adverse events, at our tertiary care center in Korea. METHODS: We retrospectively reviewed 141 cases that had undergone PEG insertion at our center from January 2009 to June 2012. The indications for PEG insertion and the acute and chronic complications caused by each type of PEG insertion were analyzed. RESULTS: The indications for PEG insertion in our cohort included neurologic disease (58.7%), malignancy (21.7%), and other indications (19.6%). Successful PEG insertions were performed on 136 cases (96.5%), and there were no PEG-associated deaths. Bleeding was the most frequent acute complication (12.8%), and wound problems were the most frequent chronic complications (8.8%). There were no statistically significant differences between the pull-type and introducer-type PEG insertion techniques in relation to complication rates in our study population. CONCLUSIONS: PEG insertion is considered a safe procedure. The pull-type and introducer-type PEG insertion techniques produce comparable outcomes, and physicians may choose either of these approaches according to the circumstances.
Cohort Studies
;
Endoscopy
;
Enteral Nutrition
;
Gastrostomy*
;
Hemorrhage
;
Korea
;
Retrospective Studies
;
Tertiary Care Centers
;
Wounds and Injuries
6.Long Term Outcomes of Pediatric Liver Transplantation According to Age.
Jeik BYUN ; Nam Joon YI ; Jeong Moo LEE ; Suk Won SUH ; Tae YOO ; Youngrok CHOI ; Jae Sung KO ; Jeong Kee SEO ; Hyeyoung KIM ; Hae Won LEE ; Hyun Young KIM ; Kwang Woong LEE ; Sung Eun JUNG ; Seong Cheol LEE ; Kwi Won PARK ; Kyung Suk SUH
Journal of Korean Medical Science 2014;29(3):320-327
Liver transplantation (LT) has been the key therapy for end stage liver diseases. However, LT in infancy is still understudied. From 1992 to 2010, 152 children had undergone LT in Seoul National University Hospital. Operations were performed on 43 patients aged less than 12 months (Group A) and 109 patients aged over 12 months (Group B). The mean age of the recipients was 7 months in Group A and 74 months in Group B. The patients' survival rates and post-LT complications were analyzed. The mean Pediatric End-stage Liver Disease score was higher in Group A (21.8) than in Group B (13.4) (P = 0.049). Fulminant hepatitis was less common in Group A (4.8%) than in Group B (13.8%) (P = 0.021). The post-transplant lymphoproliferative disorder and portal vein complication were more common in Group A (14.0%, 18.6%) than in Group B (1.8%, 3.7%) (P = 0.005). However, the 1, 5, and 10 yr patient survival rates were 93%, 93%, and 93%, in Group A and 92%, 90%, and 88% in Group B (P = 0.212). The survival outcome of pediatric LT is excellent and similar regardless of age. LTs in infancy are not riskier than those of children.
Adolescent
;
Age Factors
;
Child
;
Child, Preschool
;
End Stage Liver Disease/mortality/*surgery
;
Female
;
Graft Rejection/epidemiology
;
Graft Survival
;
Herpesviridae Infections/etiology
;
Humans
;
Infant
;
Liver Transplantation/*adverse effects/*statistics & numerical data
;
Lymphoproliferative Disorders/*etiology
;
Male
;
Proportional Hazards Models
;
Risk Factors
;
Severity of Illness Index
;
Survival Rate
;
Treatment Outcome
;
Vascular Diseases/etiology
7.Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP.
Gye Jeong OH ; Yoon Jeong SEO ; Kwi Dug YUN ; Hyun Pil LIM ; Sang Won PARK ; Kyung Ku LEE ; Tae Kwan LIM ; Doh Jae LEE
The Journal of Korean Academy of Prosthodontics 2011;49(2):120-127
PURPOSE: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. MATERIALS AND METHODS: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. ZrO2 powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at 1450degrees C. In order to evaluate the color, spectrophotometer was used to analyze the value of L*, C*, a* and b*, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (alpha= 0.05). The Tukey multiple comparison test was used for post hoc analysis. RESULTS: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). CONCLUSION: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.
Ceramics
;
Edible Grain
;
Chlorides
;
Chromium
;
Chromium Compounds
;
Humans
;
Lighting
;
Microscopy, Electron, Scanning
;
Tooth
;
Zirconium
8.Sintering behavior and mechanical properties of zirconia compacts fabricated by uniaxial press forming.
Gye Jeong OH ; Kwi Dug YUN ; Kwang Min LEE ; Hyun Pil LIM ; Sang Won PARK
The Journal of Advanced Prosthodontics 2010;2(3):81-87
PURPOSE: The purpose of this study was to compare the linear sintering behavior of presintered zirconia blocks of various densities. The mechanical properties of the resulting sintered zirconia blocks were then analyzed. MATERIAL AND METHODS: Three experimental groups of dental zirconia blocks, with a different presintering density each, were designed in the present study. Kavo Everest(R) ZS blanks (Kavo, Biberach, Germany) were used as a control group. The experimental group blocks were fabricated from commercial yttria-stabilized tetragonal zirconia powder (KZ-3YF (SD) Type A, KCM. Corporation, Nagoya, Japan). The biaxial flexural strengths, microhardnesses, and microstructures of the sintered blocks were then investigated. The linear sintering shrinkages of blocks were calculated and compared. RESULTS: Despite their different presintered densities, the sintered blocks of the control and experimental groups showed similar mechanical properties. However, the sintered block had different linear sintering shrinkage rate depending on the density of the presintered block. As the density of the presintered block increased, the linear sintering shrinkage decreased. In the experimental blocks, the three sectioned pieces of each block showed the different linear shrinkage depending on the area. The tops of the experimental blocks showed the lowest linear sintering shrinkage, whereas the bottoms of the experimental blocks showed the highest linear sintering shrinkage. CONCLUSION: Within the limitations of this study, the density difference of the presintered zirconia block did not affect the mechanical properties of the sintered zirconia block, but affected the linear sintering shrinkage of the zirconia block.
Cyclic N-Oxides
;
Zirconium
9.Adaptability of zirconia core fabricated by cold isostatic pressing.
Yoon Jeong SEO ; Kwi Dug YUN ; Hyun Seung KIM ; Sang Won PARK
The Journal of Korean Academy of Prosthodontics 2010;48(2):143-150
PURPOSE: The purpose of this study is to fabricate the new zirconia block (CNU block) and to evaluate fit of core and porcelain veneered zirconia crown. MATERIAL AND METHODS: The experimental blocks were fabricated from the commercial ytrria-stabilized zirconia powder (KZ-3YE Type A). The powder was uniaxial pressing and the green bodies were conducted using the Cold Isostatic Pressing. The zirconia blocks were presintered at 1040degrees C and the final sintering was performed at 1450degrees C. The Kavo Everest ZS blank(R) (KaVo, Biberach/Ri beta.) was used as a control group. The linear shrinkage of CNU block and Kavo block were compared. Twenty-one cores for porcelain veneered crowns were fabricated with CAD/CAM system (Everest(R), Biberach/Ribeta.). Group I: seven cores fabricated from Kavo blocks, Group II: seven cores fabricated from CNU blocks, Group III: seven cores from CNU blocks and porcelain veneering for crowns. All specimens were cemented and sectioned into two planes: diagonal and bucco-lingual. The measurement of the marginal, internal, and occlusal fit was carried out using SEM (S-4800(R)) at 30 x. The results were analyzed by one-way ANOVA test. RESULTS: The linear shrinkage of the CNU block and the KaVo block was 19.00% and 20.09%. The marginal gap of cores (29.67 +/- 6.58 micrometer) fabricated from CNU blocks showed significantly smaller than that of the cores of Kavo blocks (36.84 +/- 7.18 micrometer) (P < .05). The internal gaps of the porcelain veneered crowns (32.23 +/- 6.33 micrometer) were larger than those of the other two groups (37.57 +/- 6.81 micrometer and 38.14 +/- 6.81 micrometer). CONCLUSION: No statistically significant difference was found in between experimental groups and control group. The experimental groups in marginal gap showed significantly smaller than the control group.
Cold Temperature
;
Crowns
;
Dental Porcelain
;
Ethylnitrosourea
;
Zirconium
10.Sulfate free polyethylene glycol versus standard polyethylene glycol for colonoscopy preparation: a prospective, randomized, investigator-blinded comparison.
Jung Ho KIM ; Jeong Sik BYEON ; Sang Hyun PARK ; Jin Kyung RYU ; Byunggyu KIM ; Jun Won CHUNG ; Kwi Sook CHOI ; Byong Duk YE ; Seung Jae MYUNG ; Suk Kyun YANG ; Jin Ho KIM
Korean Journal of Medicine 2008;74(1):30-36
BACKGROUND/AIMS: Although polyethylene glycol (PEG) solution is safe and effective for bowel preparation for colonoscopy, its salty taste as well as the required large volume limits its use. Sulfate free PEG (SF-PEG) solution was developed to reduce the salty taste by removing the sodium sulfate. The aim of this study was to compare the SF-PEG solution with the standard PEG solution in regard to the quality of bowel preparation, the degree of patients' satisfaction and the side effects in Korean patients. METHODS: From July through September in 2006, 100 patients who underwent colonoscopic polypectomy were prospectively enrolled. They were randomly assigned to receive either PEG or SF-PEG solution. The quality of bowel preparation was assessed by one colonoscopist who was blinded with regard to the type of preparation used. Detailed questionnaires were used to assess the patients' tolerance and satisfaction. The serum biochemical parameters were measured before and after bowel cleansing. RESULTS: The numbers of patients whose quality of bowel preparation was excellent, good, fair and poor were 2, 43, 5 and 0 in PEG group, while this was 0, 41, 9 and 0 in SF-PEG group, respectively (p=0.118). The side effects were not different between the groups. The visual analog scale score of the patients' satisfaction was 6.4+/-2.4 in the PEG group and 5.8+/-2.8 in the SF-PEG group (p=0.237). The changes of serum biochemical parameters were also not different. CONCLUSIONS: The SF-PEG solution shows similar effectiveness and safety for bowel preparation for colonoscopy when compared to the standard PEG solution. The SF-PEG solution is a good solution to use for colonoscopy preparation.
Colonoscopy
;
Humans
;
Polyethylene
;
Polyethylene Glycols
;
Prospective Studies
;
Sodium
;
Sulfates
;
Surveys and Questionnaires

Result Analysis
Print
Save
E-mail