1.How to Achieve Diversity, Equity, and Inclusion in The Korean Society of Gastroenterology?
Nayoung KIM ; Kwangwoo NAM ; Ki-Nam SHIM ; Hyo Jung KIM ; Su Youn NAM ; Sae Kyung JOO ; Seun Ja PARK ; Yonghoon CHOI ; Yoon Ju JUNG ; Yong Sung KIM ; Ja Kyung KIM ; Seon Mee PARK
The Korean Journal of Gastroenterology 2025;85(1):22-30
With the increasing emphasis on diversity, equity, and inclusion (DEI) in organizations and institutions, academic societies in gastroenterology and hepatology are beginning to take actionable steps toward achieving DEI. The successful implementation of DEI initiatives leads to excellence in the field, improved patient outcomes, particularly in areas where health disparities are prevalent, and advances in the gastrointestinal discipline. Such implementation also results in a workforce that better reflects the growing diversity of the population. This review defines DEI and introduces the DEI policies and strategies adopted by the academic societies of gastroenterology in other countries. This paper proposes strategies to integrate DEI better into the Korean Society of Gastroenterology, emphasizing the importance of embedding DEI into the culture and strategic framework. The key strategies include establishing a DEI committee, setting clear targets, and conducting formal assessments to measure DEI progress. This study focused on enhancing workforce diversity, particularly among women and young doctors, and advocates for the need to support their academic development through male allyship and the promotion of equitable and inclusive academic cultures.
2.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively.
5.List of occupational diseases among farmers in Korea: a literature review
Hansoo SONG ; Seok-Ju YOO ; Won-Ju PARK ; Seunghyeon CHO ; Ki Soo PARK ; Joo Hyun SUNG ; Sang Jin PARK ; Seong-yong YOON ; Kyeongsoo KIM ; Dong-phil CHOI ; Hye-min KIM ; Bounggyun JU ; Kanwoo YOUN
Annals of Occupational and Environmental Medicine 2025;37(1):e2-
A comprehensive list of occupational diseases among farmers is crucial for both compensation and prevention efforts. In Korea, most farmers are self-employed, and some occupational diseases are compensated through farmer safety insurance. However, it is not harmonized with industrial accident compensation insurance and does not adequately reflect the true burden of occupational diseases among farmers. To address this gap, the authors compiled a list of occupational diseases tailored to Korean farmers by reviewing the International Labor Organization’s list of occupational diseases, the Korean Industrial Accident Compensation Insurance List, the occupational disease lists of other countries, and relevant literature on farmers’ work-related diseases.
6.How to Achieve Diversity, Equity, and Inclusion in The Korean Society of Gastroenterology?
Nayoung KIM ; Kwangwoo NAM ; Ki-Nam SHIM ; Hyo Jung KIM ; Su Youn NAM ; Sae Kyung JOO ; Seun Ja PARK ; Yonghoon CHOI ; Yoon Ju JUNG ; Yong Sung KIM ; Ja Kyung KIM ; Seon Mee PARK
The Korean Journal of Gastroenterology 2025;85(1):22-30
With the increasing emphasis on diversity, equity, and inclusion (DEI) in organizations and institutions, academic societies in gastroenterology and hepatology are beginning to take actionable steps toward achieving DEI. The successful implementation of DEI initiatives leads to excellence in the field, improved patient outcomes, particularly in areas where health disparities are prevalent, and advances in the gastrointestinal discipline. Such implementation also results in a workforce that better reflects the growing diversity of the population. This review defines DEI and introduces the DEI policies and strategies adopted by the academic societies of gastroenterology in other countries. This paper proposes strategies to integrate DEI better into the Korean Society of Gastroenterology, emphasizing the importance of embedding DEI into the culture and strategic framework. The key strategies include establishing a DEI committee, setting clear targets, and conducting formal assessments to measure DEI progress. This study focused on enhancing workforce diversity, particularly among women and young doctors, and advocates for the need to support their academic development through male allyship and the promotion of equitable and inclusive academic cultures.
7.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.How to Achieve Diversity, Equity, and Inclusion in The Korean Society of Gastroenterology?
Nayoung KIM ; Kwangwoo NAM ; Ki-Nam SHIM ; Hyo Jung KIM ; Su Youn NAM ; Sae Kyung JOO ; Seun Ja PARK ; Yonghoon CHOI ; Yoon Ju JUNG ; Yong Sung KIM ; Ja Kyung KIM ; Seon Mee PARK
The Korean Journal of Gastroenterology 2025;85(1):22-30
With the increasing emphasis on diversity, equity, and inclusion (DEI) in organizations and institutions, academic societies in gastroenterology and hepatology are beginning to take actionable steps toward achieving DEI. The successful implementation of DEI initiatives leads to excellence in the field, improved patient outcomes, particularly in areas where health disparities are prevalent, and advances in the gastrointestinal discipline. Such implementation also results in a workforce that better reflects the growing diversity of the population. This review defines DEI and introduces the DEI policies and strategies adopted by the academic societies of gastroenterology in other countries. This paper proposes strategies to integrate DEI better into the Korean Society of Gastroenterology, emphasizing the importance of embedding DEI into the culture and strategic framework. The key strategies include establishing a DEI committee, setting clear targets, and conducting formal assessments to measure DEI progress. This study focused on enhancing workforce diversity, particularly among women and young doctors, and advocates for the need to support their academic development through male allyship and the promotion of equitable and inclusive academic cultures.
10.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.

Result Analysis
Print
Save
E-mail