1.Clinical Characteristics of Pediatric Chronic Rhinosinusitis: A Nationwide Retrospective Multicenter Study
Donghyeok KIM ; Gwanghui RYU ; Sang Duk HONG ; Shin Hyuk YOO ; Sue Jean MUN ; Eun Jung LEE ; Sung-Jae HEO ; Jin Hyeok JEONG ; Dae Woo KIM ; Hyung-Ju CHO ; Min-Seok RHA ; Yong Min KIM ; Ki-Il LEE ; Ji-Hun MO ;
Journal of Rhinology 2025;32(1):28-35
Background and Objectives:
Pediatric chronic rhinosinusitis (CRS) significantly affects children’s quality of life and learning abilities. This study aimed to evaluate the postoperative outcomes in pediatric patients who underwent functional endoscopic sinus surgery (FESS) for CRS.
Methods:
A retrospective review was conducted on pediatric patients who underwent FESS for CRS at 11 university hospitals. The inclusion criteria were patients under 20 years old with bilateral disease who were operated on between January 2005 and December 2021. The data collected included demographics, clinical history, blood tests, preoperative computed tomography, and preoperative and postoperative symptom control. The Kruskal-Wallis and Fisher exact tests were used to compare the quantitative and qualitative data, respectively.
Results:
In total, 213 patients were enrolled. The mean age was 13.4±3.0 years, and 145 (68.1%) were male. One hundred sixty-four patients (77.0%) had nasal polyps and 33 patients (15.5%) underwent revision FESS. The preoperative symptoms, in order of prevalence, included nasal obstruction (87.8%), rhinorrhea (71.8%), a sense of postnasal drip (58.2%), hyposmia (44.6%), cough (24.4%), and facial fullness (18.3%). These symptoms were significantly alleviated for up to 3 years after surgery (p<0.001). At the time of the last follow-up, 121 patients (56.8%) were controlled, 80 (37.6%) were partly controlled, and 12 (5.6%) were uncontrolled. Patients in the uncontrolled group had higher Lund-Mackay scores, longer follow-up durations, and more instances of revision surgery compared to those in the controlled and partly controlled groups. When age was categorized into three groups, those aged 16 years or older tended to have lower Lund-Mackay scores and better control.
Conclusion
FESS significantly improves both the postoperative symptoms and the long-term quality of life in pediatric CRS patients. Better symptom control is associated with older age and a lower disease burden.
2.Biologics for Chronic Rhinosinusitis With Nasal Polyps: Current Status and Clinical Considerations in Korea
Ki-Il LEE ; Gwanghui RYU ; Shin Hyuk YOO ; Hyung-Ju CHO ; Ji-Hun MO ; Chang-Hoon KIM ;
Journal of Rhinology 2025;32(1):1-9
Chronic rhinosinusitis with nasal polyps (CRSwNP) is a prevalent condition that significantly impacts quality of life and places a burden on healthcare systems. The advent of biologics targeting type 2 immune pathways offers new therapeutic options for severe and/or uncontrolled CRSwNP. Initially, biologic use was guided by the European Position Paper on Rhinosinusitis and Nasal Polyps (EPOS) 2020 and the European Forum for Research and Education in Allergy and Airway Diseases (EUFOREA) guidelines, despite limited data on clinical indications, response measures, and treatment duration. Since then, numerous studies and the EPOS/EUFOREA 2023 update have refined these guidelines. The update defines clinical indications for biologics based on type 2 inflammation markers by lowering the blood eosinophil threshold from 250 to 150 cells/μL. The response to biologics is now more simply categorized into three levels based on reductions in nasal polyp size, improvements in quality of life, and enhancement of smell. Treatment evaluation is recommended at 6 months with annual follow-up. Longer administration intervals, such as every four weeks, have also proven effective in well-controlled patients. Although specific guidelines for discontinuation or switching biologics remain lacking, clinical judgment is essential in determining when treatment should be stopped or adjusted. Additionally, regulatory updates support the use of biologics for CRSwNP, and novel agents such as tezepelumab (an anti-thymic stromal lymphopoietin monoclonal antibody) continue to show promise. Finally, in Korea, biologics for CRSwNP are not covered by national health insurance, leading to extended dosing intervals due to high costs. Despite this limitation, studies have shown that adjusted dosing can maintain subjective quality of life. Recent studies by Korean authors have also explored practical considerations such as dosing intervals and comparisons to surgery. Further research is needed to optimize treatment strategies, particularly regarding cost-effectiveness and prospective studies tailored to the Korean healthcare system.
3.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Diagnosis and Management of Peyronie’s Disease: A Clinical Consensus Statement and Recommendations from the Korean Society for Sexual Medicine and Andrology
Dong Soo KIM ; Hee Jo YANG ; Hyun Cheol JEONG ; Ki Hyuck MOON ; Dong Sup LEE ; Seung Hun SONG ; Won Ki LEE ;
The World Journal of Men's Health 2025;43(1):50-59
Peyronie’s disease is an acquired condition characterized by penile deformities caused by fibrosis of the penile tunica albuginea, leading to symptoms such as penile pain, erectile dysfunction, and other associated issues. Despite extensive research, the pathophysiology of this condition remains poorly understood, and standardized diagnostic and treatment protocols are lacking. While clinical guidelines from several professional societies exist, they do not consistently account for factors such as patient ethnicity, geography, and socioeconomic status. Thus, the Korean Society for Sexual Medicine and Andrology (KSSMA) aimed to develop recommendations tailored to clinical practice in Korea. These recommendations summarize the latest evidence, including clinical practice guidelines from various international professional societies, and represent the consensus opinion of an expert group within the KSSMA. They encompass all aspects of Peyronie’s disease, including the definition, diagnosis, non-surgical interventions, and surgical treatment options.
6.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
7.Atypical features of hepatic veno‑occlusive disease/sinusoidal obstruction syndrome after inotuzumab ozogamicin in adult patients with acute lymphoblastic leukemia
Kyung‑Hun SUNG ; Daehun KWAG ; Gi June MIN ; Sung‑Soo PARK ; Silvia PARK ; Sung‑Eun LEE ; Byung‑Sik CHO ; Ki‑Seong EOM ; Yoo‑Jin KIM ; Hee‑Je KIM ; Chang‑Ki MIN ; Seok‑Goo CHO ; Seok LEE ; Jae‑Ho YOON
Blood Research 2025;60():28-
Purpose:
Inotuzumab ozogamicin (INO) has demonstrated a safe bridging role to allogeneic hematopoietic stem cell transplantation (HSCT) in patients with relapsed or refractory B-cell acute lymphoblastic leukemia (R/R B-ALL). How‑ ever, hepatic veno-occlusive disease/sinusoidal obstruction syndrome (VOD/SOS) is frequently observed. This study aimed to identify significant features of INO-associated VOD/SOS.
Methods:
We reviewed seven cases of hepatic VOD/SOS that developed either during INO salvage or after alloge‑ neic HSCT following INO-induced complete remission (CR). Diagnosis and severity grading of VOD/SOS were based on the revised criteria from the European Society for Blood and Marrow Transplantation. Defibrotide was used to treat severe to very severe cases.
Results:
Four patients developed VOD/SOS during INO salvage therapy (at 21 and 36 days post-INO1, 77 days postINO3, and 21 days post-INO5), while three were diagnosed at 2, 5, and 10 days post-HSCT following INO-induced CR.Doppler ultrasonography revealed preserved portal vein flow (range 10.2–26.0 cm/sec) and normal hepatic artery resistive index (RI, range 0.56–0.74) in all but one patient (RI 0.83). Despite this, all patients presented with massive ascites and progressively elevated total bilirubin levels. All cases were classified as severe to very severe; six were treated with defibrotide and one underwent liver transplantation. Most patients ultimately died owing to VOD/SOS progression.
Conclusion
Post-INO VOD/SOS manifested as two different clinical settings and was characterized by preserved portal vein flow, which complicated diagnosis. Despite timely defibrotide administration, clinical outcomes were poor.These findings emphasize the need for vigilance and potential consideration of prophylactic strategies for prevention of INO-associated VOD/SOS.
8.Dual-plate fixation using a medial and lateral approach for transcondylar fractures of the distal humerus in older adults: an observational cohort study
Jae Hoon LEE ; Jong Hun BAEK ; Myung-Seo KIM ; Ki-Hyeok KU
Archives of hand and microsurgery 2025;30(2):95-103
Purpose:
Commonly used surgical approaches for internal plate fixation of transcondylar distal humeral fractures may require ulnar nerve release or anterior transposition, and extensive surgical dissection can cause triceps weakness. This study reports the surgical technique and clinical outcomes of a medial and lateral approach for dual-plate fixation of transcondylar distal humeral fractures without ulnar nerve release or extensive surgical dissection.
Methods:
Sixteen patients (mean age, 81.25 years; range, 70–95 years) who underwent plate fixation using a medial and lateral approach for distal humeral transcondylar fractures were retrospectively reviewed. An anatomical distal humerus parallel or orthogonal locking plate was used for internal fixation. Ulnar nerve release was not performed in any patients. Surgical outcomes were evaluated 1 year postoperatively based on the level of pain, elbow range of motion, the Mayo elbow performance score, and postoperative complications.
Results:
The mean visual analog scale score was 0.47. The mean range of motion of the elbow joint was 13.8° for extension and 131.8° for flexion. The Mayo Elbow Performance Score was excellent in nine patients and good in seven. Bone union was achieved in all patients. There were no complications such as ulnar neuropathy, heterotopic ossification, or infection.
Conclusion
In transcondylar distal humeral fracture in older adults, a medial and lateral approach with dual anatomical locking plate fixation is recommended as a surgical technique that has the advantage of enabling rigid fixation without necessitating ulnar nerve release and extensive surgical dissection. Nonetheless, further research should be conducted.
9.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save