1.Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Tatsuya KAKEGAWA ; Katsutoshi SUGIMOTO ; Naohisa KAMIYAMA ; Hiroshi HASHIMOTO ; Hiroshi TAKAHASHI ; Takuya WADA ; Yu YOSHIMASU ; Hirohito TAKEUCHI ; Ryohei NAKAYAMA ; Kentaro SAKAMAKI ; Takao ITOI
Ultrasonography 2024;43(6):457-468
Purpose:
The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).
Methods:
A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).
Results:
The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).
Conclusion
The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
2.Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Tatsuya KAKEGAWA ; Katsutoshi SUGIMOTO ; Naohisa KAMIYAMA ; Hiroshi HASHIMOTO ; Hiroshi TAKAHASHI ; Takuya WADA ; Yu YOSHIMASU ; Hirohito TAKEUCHI ; Ryohei NAKAYAMA ; Kentaro SAKAMAKI ; Takao ITOI
Ultrasonography 2024;43(6):457-468
Purpose:
The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).
Methods:
A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).
Results:
The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).
Conclusion
The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
3.Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Tatsuya KAKEGAWA ; Katsutoshi SUGIMOTO ; Naohisa KAMIYAMA ; Hiroshi HASHIMOTO ; Hiroshi TAKAHASHI ; Takuya WADA ; Yu YOSHIMASU ; Hirohito TAKEUCHI ; Ryohei NAKAYAMA ; Kentaro SAKAMAKI ; Takao ITOI
Ultrasonography 2024;43(6):457-468
Purpose:
The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).
Methods:
A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).
Results:
The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).
Conclusion
The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
4.Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Tatsuya KAKEGAWA ; Katsutoshi SUGIMOTO ; Naohisa KAMIYAMA ; Hiroshi HASHIMOTO ; Hiroshi TAKAHASHI ; Takuya WADA ; Yu YOSHIMASU ; Hirohito TAKEUCHI ; Ryohei NAKAYAMA ; Kentaro SAKAMAKI ; Takao ITOI
Ultrasonography 2024;43(6):457-468
Purpose:
The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).
Methods:
A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).
Results:
The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).
Conclusion
The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
5.Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Tatsuya KAKEGAWA ; Katsutoshi SUGIMOTO ; Naohisa KAMIYAMA ; Hiroshi HASHIMOTO ; Hiroshi TAKAHASHI ; Takuya WADA ; Yu YOSHIMASU ; Hirohito TAKEUCHI ; Ryohei NAKAYAMA ; Kentaro SAKAMAKI ; Takao ITOI
Ultrasonography 2024;43(6):457-468
Purpose:
The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).
Methods:
A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).
Results:
The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).
Conclusion
The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
6.Infection control measures promoted by the public health center for “housing for the elderly” facilities during norovirus cluster outbreaks
Kentaro SUGIMOTO ; Noriko SATO ; Yuko AMAMIYA ; Noriko HOSOYA
Journal of Rural Medicine 2022;17(3):151-157
Objective: “Housing for the elderly” is a type of facility where a few healthcare staff and care workers provide long-term care to residents. This study aimed to explore the infection control measures promoted by the public health centers (PHC) when a cluster of norovirus cases occurred in this type of facility.Materials and Methods: This study involved a prefectural office in Japan and collected the records of PHC surveys/instructions of norovirus cluster cases that occurred in “housing for the elderly” facilities between 2017 and 2019. The records provided information about the case characteristics (cluster periods and number of infected individuals) and instructions for infection control by the PHC. We tabulated the case characteristics and performed a descriptive qualitative analysis to extract the instructions from the PHC.Results: Twelve clusters of cases were included in the study. Approximately 16% of the residents and care workers in each facility were infected, and it took an average of 23 days from the start of the outbreak to the end. Nine categories of PHC instructions emerged after the data analysis. “Collaboration with community healthcare workers” included instructions by the PHC to share information with external physicians and home-visiting nurses. In “precautions when caring for elderly residents with functional decline”, the procedure for changing diapers and infection control measures considering the behavior of residents with dementia were advised. If the contents of the infection control manuals were deemed to be inadequate, an “improvement of the infection control manuals” was instructed.Conclusion: To implement effective infection control by care workers at “housing for the elderly” facilities, the PHC should promote the involvement of community physicians and nurses and advise on clear procedures based on residents’ functional decline.
7.Impact of Rotation Correction after Brace Treatment on Prognosis in Adolescent Idiopathic Scoliosis.
Kentaro YAMANE ; Tomoyuki TAKIGAWA ; Masato TANAKA ; Yoshihisa SUGIMOTO ; Shinya ARATAKI ; Toshifumi OZAKI
Asian Spine Journal 2016;10(5):893-900
STUDY DESIGN: Level 4 retrospective review. PURPOSE: Brace treatment is the standard nonoperative treatment for adolescent idiopathic scoliosis (AIS). Rotation correction is also important, because AIS involves a rotation deformity. The purpose of this study was to evaluate the impact of rotation correction after Osaka Medical College (OMC) brace treatment on clinical outcomes in AIS. OVERVIEW OF LITERATURE: Brace treatment has a significant effect on the progression of AIS. However, few reports have examined rotation correction after brace treatment. METHODS: A total of 46 patients who wore the OMC brace were retrospectively reviewed. The curve magnitude was determined according to the Cobb method, and the rotation angle of the apical vertebrae was measured by the modified Nash-Moe method. Based on the difference in the rotation angle before and after the initial brace treatment, patients were divided into two groups. Group A (n=33) was defined as no change or improvement of the rotation angle; group B (n=13) was defined as deterioration of the rotation angle. If the patients had curve or rotation progression of 5° or more at skeletal maturity, or had undergone surgery, the treatment was considered a failure. RESULTS: Differences of rotation angle between before and after the initial brace treatment were 2°±2° in group A and –3°±2° in group B (p<0.001). The rates of treatment failure were 42% in group A and 77% in group B (p<0.05). This study included 25 patients with Lenke type 1 (54%). Group A (24%) with Lenke type 1 also had a significantly better success rate of brace treatment than group B (75%) (p<0.05). CONCLUSIONS: Insufficient rotation correction increased brace treatment failure. Better rotation correction resulted in a higher success rate of brace treatment in patients with Lenke type 1.
Adolescent*
;
Braces*
;
Congenital Abnormalities
;
Humans
;
Methods
;
Prognosis*
;
Retrospective Studies
;
Scoliosis*
;
Spine
;
Treatment Failure


Result Analysis
Print
Save
E-mail