1.Mechanism of Inducing Ferroptosis in Hepatocellular Carcinoma Cells by Shugan Quyu Jiedu Prescription Based on p53/SLC7A11/GPX4 Pathway
Xiaojun CAI ; Renyi YANG ; Zhibin WANG ; Yilin GONG ; Ke WANG ; Lizhu LIN ; Chong ZHONG ; Jing LI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(8):74-82
ObjectiveTo investigate the effect of Shugan Quyu Jiedu prescription (SGQYJDF) on inducing ferroptosis in hepatocellular carcinoma cells based on the tumor protein 53 (p53)/solute carrier family 7 member 11 (SLC7A11)/glutathione peroxidase 4 (GPX4) pathway. MethodMHCC97H cells were divided into the blank serum group (10% blank serum medium), SGQYJDF-containing serum low concentration group (5% SGQYJDF-containing serum and 5% blank serum medium), SGQYJDF-containing serum medium concentration group (7.5% SGQYJDF-containing serum and 2.5% blank serum medium), SGQYJDF-containing serum high concentration group (10% SGQYJDF-containing serum medium) and sorafenib group (sorafenib concentration of 10 μmol·L-1 in 10% blank serum medium). After 24 hours of intervention, the cell survival rate was detected by cell counting kit-8 (CCK-8) assay. The cell proliferation ability was detected by 5-ethynyl-2′-deoxyuridine (EdU) staining. The intracellular ferrous ion (Fe2+) level was detected by ferrous ion fluorescent probe (FerroOrange) staining. The intracellular malondialdehyde (MDA) and glutathione (GSH) levels were detected by colorimetric assays. The ultrastructure of mitochondria was observed by transmission electron microscopy. The expression levels of ferroptosis-related proteins p53, SLC7A11 and GPX4 were detected by Western blot. ResultIn terms of cell viability, compared with the blank serum group, the SGQYJDF group showed a dose-dependent decrease in the survival rate of MHCC97H cells. Effect of the medium and high concentrations of SGQYJDF on the survival rate of MHCC97H cells were significantly decreased (P<0.01). Additionally, the results of the EdU assay showed that both the medium and high concentrations of SGQYJDF were able to inhibit the proliferation ability of MHCC97H cells (P<0.05, P<0.01). Regarding the biochemical indicators of ferroptosis, compared to the blank serum group, the medium and high concentrations of SGQYJDF were able to dose-dependently increase the intracellular Fe2+ level (P<0.01). The low, medium, and high concentrations of SGQYJDF were able to dose-dependently decrease the level of GSH in MHCC97H cells (P<0.01) and increase the level of MDA in the cells (P<0.05, P<0.01). In terms of pathway-related protein expression, compared to the blank serum group, the medium and high concentrations of SGQYJDF could significantly increase the expression of p53 (P<0.01). The low, medium, and high concentrations of SGQYJDF could significantly decrease the expression of GPX4 (P<0.01). The high concentration of SGQYJDF could decrease the expression of SLC7A11 (P<0.01). In terms of the cell morphology of ferroptosis, compared with the blank serum group, transmission electron microscopy revealed that the low concentration of SGQYJDF caused mitochondrial deformation, while the medium and high concentrations of SGQYJDF resulted in reduced mitochondrial volume, increased double-layer membrane density, and decreased mitochondrial cristae. These features were similar to those of sorafenib-induced ferroptosis. Furthermore, compared with the sorafenib group, the high concentration of SGQYJDF showed no statistically significant differences in cell survival rate, proliferation ability, Fe2+ level, MDA level, and GSH level. ConclusionThe results suggest that SGQYJDF may induce ferroptosis and inhibit proliferation in hepatocellular carcinoma MHCC97H cells by upregulating the expression of p53, suppressing the expressions of GPX4 and SLC7A11, downregulating the level of GSH, and leading to the accumulation of intracellular Fe2+ and MDA.
2.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
3.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
4.Antibacterial magnesium oxide-calcium phosphate composite coating prepared by combining electrodeposition and sol-gel impregnation
Junjie TAN ; Jiaheng DU ; Zhenyu WEN ; Jiyuan YAN ; Kui HE ; Ke DUAN ; Yiran YIN ; Zhong LI
Chinese Journal of Tissue Engineering Research 2024;28(29):4663-4670
BACKGROUND:Calcium phosphate(CaP)coatings are widely used to improve the integration of titanium implants into bone but these coatings are associated with risks of infection.It is thus desirable to confer antibacterial properties to CaP coatings. OBJECTIVE:To prepare CaP-MgO composite coatings by impregnating magnesium oxide(MgO)sol into CaP coatings and assess the in vitro antibacterial activities and cytocompatibility. METHODS:An electrolyte was determined by titration and used for CaP coating electrodeposition on titanium(referred to as Ti-CaP).MgO was impregnated into the coating by immersing in an MgO sol with different mass fractions(15%,30%,50%)and subsequently calcined to form MgO-CaP composite coatings,which were recorded as Ti-CaP-15Mg,Ti-CaP-30Mg and Ti-CaP-50Mg,respectively.Microstructure,tensile properties,critical load,and Mg2+ release of coatings in vitro were characterized.Antibacterial activity was assayed using spread plate method by culturing S.aureus on the pure titanium sheet surface and Ti-CaP,Ti-Cap-15mg,Ti-Cap-30mg and Ti-Cap-50mg surfaces for 24 and 48 hours.Mouse osteoblast suspension was inoculated on pure titanium sheets and Ti-CaP,Ti-CaP-15Mg,Ti-CaP-30Mg and Ti-CaP-50Mg coated titanium sheets,respectively.Cell proliferation was detected by CCK-8 assay,and cell survival rate was calculated.The morphology of composite coating soaked in DMEM was also observed. RESULTS AND CONCLUSION:(1)Homogeneous,microporous CaP coatings consisting of octacaclium phosphate crystal flakes were prepared on titanium by electrodeposition.After sol impregnation-calcination,MgO aggregates were filled into the inter-flake voids.The extent of MgO filling and Mg concentration in the coating increased with the number of sol impregnation procedures.When immersed in phosphate buffered saline,all composite coatings actively released Mg2+ within 1 day;subsequently,the Mg2+ release slowed down on day 3.A small amount of Mg2+ release was still detected on day 7.The yield strength,tensile strength and fracture growth rate of Ti-CaP-30Mg coated titanium were not significantly different from those of pure titanium(P>0.05).There was no significant difference in the critical load of Ti-CaP,Ti-CaP-15Mg,Ti-CaP-30Mg and Ti-CaP-50Mg groups(P>0.05).(2)Except that pure titanium sheet and Ti-CaP had no antibacterial properties,the other samples had good antibacterial properties,and the antibacterial rate increased with the increase of MgO content in the coating.(3)After 1 and 3 days of co-culture,the cell survival rate of Ti-CaP-15Mg,Ti-CaP-30Mg and Ti-CaP-50Mg groups was lower than that of pure titanium group and Ti-CaP group(P<0.05).After 5 and 7 days of culture,there was no significant difference in cell survival rate among five groups(P>0.05).The content of MgO in the coating decreased gradually with the time of immersion in the medium.(4)The MgO sol impregnation added antibacterial properties to the CaP coatings while retained their biocompatibility.
5.Clinical trial of brexpiprazole in the treatment of adults with acute schizophrenia
Shu-Zhe ZHOU ; Liang LI ; Dong YANG ; Jin-Guo ZHAI ; Tao JIANG ; Yu-Zhong SHI ; Bin WU ; Xiang-Ping WU ; Ke-Qing LI ; Tie-Bang LIU ; Jie LI ; Shi-You TANG ; Li-Li WANG ; Xue-Yi WANG ; Yun-Long TAN ; Qi LIU ; Uki MOTOMICHI ; Ming-Ji XIAN ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(5):654-658
Objective To evaluate the efficacy and safety of brexpiprazole in treating acute schizophrenia.Methods Patients with schizophrenia were randomly divided into treatment group and control group.The treatment group was given brexpiprozole 2-4 mg·d-1 orally and the control group was given aripiprazole 10-20 mg·d-1orally,both were treated for 6 weeks.Clinical efficacy of the two groups,the response rate at endpoint,the changes from baseline to endpoint of Positive and Negative Syndrome Scale(PANSS),Clinical Global Impression-Improvement(CGI-S),Personal and Social Performance scale(PSP),PANSS Positive syndrome subscale,PANSS negative syndrome subscale were compared.The incidence of treatment-related adverse events in two groups were compared.Results There were 184 patients in treatment group and 186 patients in control group.After treatment,the response rates of treatment group and control group were 79.50%(140 cases/184 cases)and 82.40%(150 cases/186 cases),the scores of CGI-I of treatment group and control group were(2.00±1.20)and(1.90±1.01),with no significant difference(all P>0.05).From baseline to Week 6,the mean change of PANSS total score wese(-30.70±16.96)points in treatment group and(-32.20±17.00)points in control group,with no significant difference(P>0.05).The changes of CGI-S scores in treatment group and control group were(-2.00±1.27)and(-1.90±1.22)points,PSP scores were(18.80±14.77)and(19.20±14.55)points,PANSS positive syndrome scores were(-10.30±5.93)and(-10.80±5.81)points,PANSS negative syndrome scores were(-6.80±5.98)and(-7.30±5.15)points,with no significant difference(P>0.05).There was no significant difference in the incidence of treatment-related adverse events between the two group(69.00%vs.64.50%,P>0.05).Conclusion The non-inferiority of Brexpiprazole to aripiprazole was established,with comparable efficacy and acceptability.
6.Analysis of core functional components in Yinchenhao Decoction and their pathways for treating liver fibrosis
Xingmei CHEN ; Qinwen LIU ; Yi LI ; Xiaoyu ZHONG ; Qiling FAN ; Ke MA ; Liuting LUO ; Daogang GUAN ; Zhibo ZHU
Journal of Southern Medical University 2024;44(8):1508-1517
Objective To analyze the core functional component groups(CFCG)in Yinchenhao Decoction(YCHD)and their possible pathways for treating hepatic fibrosis based on network pharmacology.Methods PPI data were extracted from DisGeNET,Genecards,CMGRN and PTHGRN to construct a weighted network using Cytoscape 3.9.1.The data of the chemical components in YCHD were obtained from Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform(TCMSP),and the potential active components and targets were selected using PreADMET Web server and SwissTargetPrediction.A fusion model was constructed to obtain the functional effect space and evaluate the effective proteins to identify the CFCG followed by GO and KEGG pathway enrichment analyses for all the targets.In cultured human hepatic stellate cells(LX-2 cells),the cytotoxicity of different compounds in YCHD was tested using CCK-8 assay;the effects of these compounds on collagen α1(Col1a1)mRNA expression and the pathways in 20 ng/mL TGF-β1-stimulated cells were analyzed using RT-qPCR and Western blotting.Results A total of 1005 pathogenic genes,226 potential active components and 1529 potential targets in YCHD and 52 potential targets of CFCG were obtained.Benzyl acetate,vanillic acid,clorius,polydatin,lauric acid and ferulic acid were selected for CCK-8 verification,and they all showed minimal cytotoxicity below the concentration of 200 μmol/L.Clorius,polydatin,lauric acid and ferulic acid all effectively inhibited TGF-β1-induced LX-2 cell activation.At the concentration of 200 μmol/L,all these 4 components inhibited PI3K,p-PI3K,AKT,p-AKT,ERK,p-ERK,P38 MAPK and p-P38 MAPK expressions in TGF-β1-induced LX-2 cells.Conclusion The therapeutic effect of YCHD on hepatic fibrosis is probably mediated by its core functional components including benzyl acetate,vanillic acid,clorius,polydatin,lauric acid and ferulic acid,which inhibit the PI3K-AKT and MAPK pathways in hepatic stellate cells.
7.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.
8.Development and performance testing of a novel transcatheter tricuspid valve interventional device
Qiuji WANG ; Junfei ZHAO ; Lishan ZHONG ; Shuo XIAO ; Chaolong ZHANG ; Zhenzhong WANG ; Dou FANG ; Yuxin LI ; Yingjie KE ; Shanwen PANG ; Junqiang QIU ; Biaochuan HE ; Huanlei HUANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):885-890
Objective To develop a novel transcatheter tricuspid valve replacement device and test its performance. Methods The transcatheter tricuspid valve stent consisted of double-layer self-expanding nitinol stent, biotissue-derived bovine pericardial leaflets, and PTFE woven. The delivery system, mainly consisting of a handle control unit and a delivery sheath, was sent to the correct position via right atrium or jugular vein. The sheath had a visualization feature, and the handle control unit could realize the functions of stable release and partial recovery of the interventional valve. In addition, this study performed animal survival experiments on the basis of in vitro experiments. A large-white pig was used as the experimental animal. Cardiopulmonary bypass was established through median thoracotomy, then the right atrium was opened, and the interventional valve was released under direct vision without cardiac arrest. Approximately 1 month after interventional valve implantation, the maneuverability and stability of the interventional tricuspid device were evaluated by autopsy. Results Through the animal experiment, the interventional valve was successfully released, and the anchoring was satisfactory. Postoperative transthoracic echocardiography showed that the interventional valve opened and closed well, the flow rate of tricuspid valve was 0.6 m/s, and there was no obvious tricuspid regurgitation. One month after the operation, we dissected the large-white pig and found the interventional valve was not deformed or displaced, the leaflets were well aligned, and there was thrombus attachment in the groove between the inner and outer layers of the interventional valve. Conclusion Animal experiment shows that the novel device can stably and firmly attach to the tricuspid annulus, with good anchoring effect, and effectively reduce paravalvular leakage.
9.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]
10.Catheter-related bloodstream infection caused by Staphylococcus pas-teuri:one case report
Chong-Zhen WANG ; Shan ZHONG ; Li-Xia XU ; Li-Cheng WANG ; Xiao-Ying FU ; Huan LI ; Yuan-Li LI ; Xiong ZHU ; Hai CHEN ; Dong-Ke CHEN
Chinese Journal of Infection Control 2024;23(8):1040-1043
One patient was admitted to a hospital due to"sepsis,chronic kidney disease,type 2 diabetes,shock,and cerebral infarction".Patient's blood specimen was taken for clinical examination.Aerobic and anaerobic culture results of catheter blood and venous blood were both positive.The pathogen was identified as Staphylococcus pas-teuri by VITEK MS,and the patient was diagnosed as catheter-related bloodstream infection caused by Staphylo-coccus pasteuri.Clinical empirical use of piperacillin for anti-infection treatment was ineffective,and vancomycin was eventually used for treatment based on in vitro antimicrobial susceptibility testing.Patient's condition improved after removing the venous catheter.There are currently no reported cases of Staphylococcus pasteuri in China.Ear-ly identification of pathogen and adjustment of treatment plans based on antimicrobial susceptibility testing results are crucial for effective treatment of this case.

Result Analysis
Print
Save
E-mail