1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Clinical trial of lupatadine combined with azlastine hydrochloride nasal spray in the treatment of allergic rhinitis patients
Hong-Bin XU ; Ke-Liang LI ; Ke LI ; Mei WANG ; Lu-Lu HU ; Ming-Peng SUN ; Bu-Sheng TONG
The Chinese Journal of Clinical Pharmacology 2024;40(19):2822-2825
Objective To observe the clinical efficacy and safety of lupatadine tablets combined with azelastine hydrochloride nasal spray in the treatment of allergic rhinitis patients.Methods Patients with allergic rhinitis were randomly divided into control group and treatment group.Both groups received general treatment.On this basis,the control group was given azelastine hydrochloride nasal spray 0.14 mg per nostril each time,bid;on the basis of control group,the treatment group received lupatadine tablets 10 mg each time,orally,qd.Two groups were treated for 4 weeks.The clinical efficacy,rhinoconjunctivitis related quality of life questionnaire(RQLQ),serum indexes[interleukin-6(IL-6),IL-1 β,tumor necrosis factor-α(TNF-α),immunoglobulin E(IgE)]and safety were compared between the two groups.Results Treatment group were enrolled 53 cases,4 cases dropped out,and 49 cases were finally included in the statistical analysis.Control group were enrolled 53 cases,4 cases dropped out,and 49 cases were finally included in the statistical analysis.After treatment,the total effective rates of the treatment and control groups were 95.92%(47 cases/49 cases)and 81.63%(40 cases/49 cases)with significant difference(P<0.05).After treatment,the RQLQ scores of treatment and control groups were(49.57±6.97)and(58.18±7.78)points,IL-6 levels were(5.12±1.25)and(7.34±1.46)ng·L-1,IL-1 β levels were(12.25±5.64)and(20.05±6.32)pg·mL-1,TNF-α levels were(3.25±0.62)and(4.45±0.49)pg·mL-1,the IgE levels were(114.28±19.63)and(136.84±30.14)μg·L-1,respectively,the differences were statistically significant difference(all P<0.05).The adverse drug reactions of two groups were dry mouth,fatigue,dizziness and drowsiness.The total incidences of adverse drug reactions in the treatment and control groups were 16.33%and 10.20%without significant difference(P>0.05).Conclusion Lupatadine tablets combined with azostine hydrochloride nasal spray have a definitive clinical efficacy in the treatment of allergic rhinitis patients,which can effectively reduce the inflammatory reaction,reduce the IgE levels,improve the quality of life,without increasing the incidence of adverse drug reactions.
7.Study on fatigue vibration evaluation of ultrasonic knife tip based on Q factor
Ke-Sheng WANG ; Ze-Kai LI ; Pei LIU ; Jing-Sheng SUN ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(6):17-22
Objective To propose a Q factor-based fatigue vibration evaluation method of the ultrasonic knife tip.Methods Firstly,an ultrasonic cutter fatigue testing table was established to realize repeated cutting,which was composed of a power supply module,a three-axis moving module,an ultrasonic cutter clamping module and a control module.Secondly,10 ultrasonic knives of some brand underwent fatigue testing with the table,during which non-contact measurement of the ultrasonic knife tip vibration was carried out and the Q factors were calculated at the five periods of the fatigue test,including the periods before cutting,after 500 times of cutting,after 1 000 times of cutting,after 2 000 times of cutting and after 3 000 times of cutting.Finally,the average cutting speed and burst pressure for coagulated vessels were computed at each period to validata the effectiveness of the method proposed.Results It's indicated that Q factor could effectively reflect the fatigue degradation of the ultrasonic knife tip,while the average cutting speed and burst pressure for coagulated vessels were difficult to efficiently evaluate the fatigue degradation level of the ultrasonic knife tip due to the uncertainty factors in the measurement process.Conclusion The proposed Q factor-based evaluation method can directly evaluate fatigue vibration of the ultrasonic knife tip in an accurate and quantitative manner.[Chinese Medical Equipment Journal,2024,45(6):17-22]
8.Accurate quantitative evaluation of MRI scanning noise based on laser vibrometry technology
Ke-Sheng WANG ; Pei-Jia XU ; Pei LIU ; Jing-Sheng SUN ; Ze-Kai LI ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(10):20-24
Objective To carry out accurate quantative evaluation of MRI scanning noise based on laser vibrometry technology.Methods Skull and spine MRI was performed with mute and conventional sequences.A laser vibrometry device was used to sample the surface vibration noise at the outer edge of the inspection hole of MRI system according to GB/T 16539-1996 Acoustics—Determination of sound power levels of noise sources using vibration velocity—Measurement for seal machinery,and the indicators of sound power level,sound pressure level and perceived noise level obtained by the three calculation methods(LPN1,LPN2 and LPN3)were analyzed with some dedicated MRI noise analysis software.Results The peak sound pressure levels for conventional and mute sequences of skull scanning were 81 and 63 dB(A),respectively,and mute sequence reduced the noise level significantly;the peak sound pressure levels for conventional and mute sequences of spine scanning were 79 and 75 dB(A),respectively,and the noise reduction level was significantly lower than that of skull scanning.Significant differences in noise reduction were not found in spine scanning sequences,while were found in skull scanning sequences.During spine and skull scanning LPN1,LPN2 and LPN3 obtained by the three calculation methods of conventional and mute sequences were all higher than the overall sound power and overall pressure levels obviously.Conclusion Mute sequence can not realize linear noise reduction for the whole frequency band,the perceived noise of the human ear during MRI scanning is related directly to the scanning sequence,and there may be some bias when only one physical indicator is involved in the noise evaluation of MRI system.[Chinese Medical Equipment Journal,2024,45(10):20-24]
9.Overexpression of Hsp70 Promoted the Expression of Glycolysis-related Genes in C2C12 Cells
Lei QIN ; Ke XU ; Chun-Guang ZHANG ; Han CHU ; Shi-Fan DENG ; Jian-Bin ZHANG ; Hua YANG ; Liang HONG ; Gui-Feng ZHANG ; Chao SUN ; Lei PU
Chinese Journal of Biochemistry and Molecular Biology 2024;40(10):1417-1425
The aim of this study was to investigate the impact of overexpressing 70-kD heat shock pro-teins(Hsp70)on glycolysis in C2C12 cells during myogenesis and adipogenesis.Using C2C12 cells as the research material,adenovirus was used to overexpress the Hsp70 gene,and changes in the expression of glycolytic genes were detected using fluorescence quantitative PCR and Western blotting techniques.The study indicated that during C2C12 cell myogenic differentiation,the expression trend of the Hsp70 gene was consistent with that of Gsk3β,Pkm,Prkag3,Pfkm,and Hk-2 genes,suggesting a relationship between Hsp70 and the glycolytic pathway during myogenic differentiation.Overexpression of Hsp70 in the later stages of myogenic differentiation significantly upregulated the expression of Gsk3β,Pkm,Prk-ag3,and Pfkm genes(P<0.05),with no significant impact on Hk-2 gene expression(P>0.05).Dur-ing C2C12 cell adipogenic induction,the expression trend of the Hsp70 gene was similar to that of Gsk3β,Pkm,Prkag3,Pfkm,and Hk-2 genes,indicating a relationship between Hsp70 and the glycolytic path-way during adipogenic induction.Following Hsp70 overexpression,in the later stages of adipogenic in-duction,the number of lipid droplets was significantly higher compared to the control group,with a sig-nificant upregulation of Gsk3β,Pkm,Prkag3,and Pfkm gene expression(P<0.05),while Hk-2 gene expression was not significantly affected(P>0.05).In conclusion,Hsp70 in C2C12 cells in myogenic and adipogenic states promoted the breakdown of glycogen into 6-phospho-glucose,thereby enhancing the glycolytic pathway,providing insights into the functional role of the Hsp70 gene in glycolysis in C2C12 cells.
10.Preparation Method and Quality Evaluation of Novel Frozen Human Platelets
Yi-Zhe ZHENG ; Dong-Dong LI ; Geng-Wei YAN ; Bao-Jian WANG ; Ke WANG ; Lei WANG ; Shao-Duo YAN ; Yan-Hong LI ; Qiu-Xia FU ; Zhen-Wei SUN
Journal of Experimental Hematology 2024;32(4):1264-1270
Objective:To optimize the technical parameters related to the preparation of novel frozen human platelets and formulate corresponding protocol for its preparation.Methods:Novel frozen human platelets were prepared with O-type bagged platelet-rich plasma(PRP),the key technical parameters(DMSO addition,incubation time,centrifugation conditions,etc.)of the preparation process were optimized,and the quality of the frozen platelets was evaluated by routine blood tests,apoptosis rate,platelet activation rate and surface protein expression level.Results:In the preparation protocol of novel frozen human platelets,the operation of centrifugation to remove supernatant was adjusted to before the procedure of platelets freezing,and the effect of centrifugation on platelets was minimal when the centrifugation condition was 800 xg for 8 min.In addition,platelets incubated with DMSO for 30 min before centrifugation exhibited better quality after freezing and thawing.The indexes of novel frozen human platelets prepared with this protocol remained stable after long-term cryopreservation.Conclusion:The preparation technique of novel frozen human platelets was established and the protocol was formulated.It was also confirmed that the quality of frozen platelets could be improved by incubating platelets with DMSO for 30 min and then centrifuging them at 800 ×g for 8 min in the preparation of novel frozen human platelets.