1.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.

Result Analysis
Print
Save
E-mail