1.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Determination of rifapentine concentration in human serum by two-dimensional liquid chromatography
Tao KE ; Tian HE ; Pei-Ze ZHANG ; Wei LI ; Yang ZHOU ; Feng WANG ; Miao-Na LIU
The Chinese Journal of Clinical Pharmacology 2024;40(11):1638-1641
Objective To develop a two-dimensional liquid chromatographic method for rifapentine blood concentration determination.Methods The blood concentration of rifapentine was determined by a novel two-dimensional liquid chromatography(2D-LC)with a one-dimensional column:Aston SC2T(3.5 mm ×50.0 mm,5 μm);a two-dimensional column:Aston SCB(4.6 mm ×250.0 mm,5 μm);the temperature of the column was 40 ℃;the flow rate was 1.0 mL·min-1;the detection wavelength was 335 nm;the injection volume was 300 μL.The specificity,standard curve and lower limit of quantification,precision and recovery,and stability of the method were investigated.The method was used to determine the blood concentration of rifapentine in tuberculosis patients.Results Rifapentine showed good linearity within 0.33-18.62 μg·mL-1 with the standard curve equation of y=2.68 x 105x-5 850.36(r=0.997),the recoveries were 99.81%-105.08%,and the intra-and inter-day precision were ≤4.84%.The results of rifapentine blood concentration measurements in tuberculosis patients were in the range of 0.10-54.70μg·mL-1,and 64.74%were within the therapeutic window concentration range(8-30 μg·mL-1).Conclusion The method is easy to operate,has high sensitivity,low detection limit and high specificity,and is suitable for clinical blood concentration determination.Individual differences in the administration of rifapentine in tuberculosis patients are large,and blood concentration monitoring is required for individualized treatment.
8.Treatment of Chronic Bronchitis Based on Theory of "Warming Lung Yang and Protecting Yin Skin"
Zhen LU ; Qingyin LIU ; Weiwei YAO ; Weiwei TAO ; Lina LIU ; Ke PEI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(15):215-223
Chronic bronchitis (CB) is a common respiratory system disease that is classified as a lung disease in traditional Chinese medicine (TCM) and is closely related to lung dysfunction. Lung Yang is the Yang Qi of the lungs,which drives the physiological activities within the lungs. It has physiological functions such as warming the lung system,regulating lung fluid,and dispersing the protective Yang. It can be distributed on the surface of the airway's Yin skin through sweat pores in the form of airflow and fluid,playing a protective and nourishing role. If the protective Yang fails to guard the Yin skin or if the lung fluid cannot nourish the Yin skin,the structural integrity of the airway's Yin skin may be compromised. This may weaken lung Yang's functions, such as clearing phlegm turbidity,dispersing lung fluid,and resisting external pathogens. Consequently, the retention of phlegm turbidity,insufficient nourishment of the Yin skin,and invasion by external pathogens all damage the lung Yang,burn the lung fluid,and exacerbate the pathological state of Yin skin unprotected,forming a vicious cycle that ultimately results in lung Yang asthenia and then the onset of CB. Based on the intrinsic connection between "Yin skin unprotected" and "lung Yang asthenia",this paper interprets the etiology and pathogenesis of CB. It proposes that "Yin skin unprotected" in the airway is the basic cause of CB and "lung Yang asthenia" caused by "Yin skin unprotected" is the core pathogenesis of CB. By integrating micro differentiation indicators with macro differentiation syndromes, the study explores its modern biological basis. Guided by the theory of "warming the lung Yang and protecting the Yin skin" and based on modern pharmacology research,this study further explores the scientific connotation of single TCM and compound formulations for treating TCM by warming the lung Yang and protecting the Yin skin. Furthermore, it proposes methods for dispelling pathogenic factors and protecting the Yin skin during the acute exacerbation phase,as well as nourishing and warming lung Yang during the remission phase,in order to provide new ideas for the early prevention and treatment of TCM.
9.Progress and practice of objective measurement of physical behaviors in large-scale cohort research
Yuanyuan CHEN ; Yalei KE ; Jun LYU ; Dianjianyi SUN ; Lang PAN ; Pei PEI ; Huaidong DU ; Junshi CHEN ; Zhengming CHEN ; Liming LI ; Doherty AIDEN ; Canqing YU
Chinese Journal of Epidemiology 2024;45(1):35-40
Due to the limited reliability of traditional self-completed questionnaire, the accuracy of measurement of physical behaviors (physical activity, sedentary behavior and sleep) is not high. With the development of technology, wearable devices (e.g. accelerometer) can be used for more accurate measurement of physical behaviors and have great application potential in large-scale research. However, the data of objective measurement of physical behaviors from large-scale cohort research in Asian populations is still limited. Between August 2020 and December 2021, the 3 rd resurvey of China Kadoorie Biobank (CKB) project used Axivity AX3 wrist triaxial accelerometer to collect the data of participants' daily activity and sleep status. A total of 20 370 participants from 10 study areas were included in the study, in whom 65.2% were women, and the age was (65.4±9.1) years. The participants' physical activity level varied greatly in different study areas. The objective measurement of participants' physical behaviors in CKB project has provided valuable resources for the description of 24-hour patterns of physical behaviors and evaluation of the health effect of physical activity, sedentary behavior and sleep as well as their association with diseases in the elderly in China.
10.Distribution and influencing factors of lipoprotein (a) levels in non-arteriosclerotic cardiovascular disease population in China
Yalei KE ; Lang PAN ; Jun LYU ; Dianjianyi SUN ; Pei PEI ; Yiping CHEN ; Ling YANG ; Huaidong DU ; Robert CLARKE ; Junshi CHEN ; Zhengming CHEN ; Xiao ZHANG ; Ting CHEN ; Runqin LI ; Litong QI ; Liming LI ; Canqing YU
Chinese Journal of Epidemiology 2024;45(6):779-786
Objective:To describe the distribution of lipoprotein (a) [Lp(a)] levels in non-arteriosclerotic cardiovascular disease (ASCVD) population in China and explore its influencing factors.Methods:This study was based on a nested case-control study in the CKB study measured plasma biomarkers. Lp(a) levels was measured using a polyclonal antibody-based turbidimetric assay certified by the reference laboratory and ≥75.0 nmol/L defined as high Lp(a). Multiple logistic regression model was used to examine the factors related to Lp(a) levels.Results:Among the 5 870 non-ASCVD population included in the analysis, Lp(a) levels showed a right-skewed distribution, with a M ( Q1, Q3) of 17.5 (8.8, 43.5) nmol/L. The multiple logistic regression analysis found that female was associated with high Lp(a) ( OR=1.23, 95% CI: 1.05-1.43). The risk of increased Lp(a) levels in subjects with abdominal obesity was significantly reduced ( OR=0.68, 95% CI: 0.52-0.89). As TC, LDL-C, apolipoprotein A1(Apo A1), and apolipoprotein B(Apo B) levels increased, the risk of high Lp(a) increased, with OR (95% CI) for each elevated group was 2.40 (1.76-3.24), 2.68 (1.36-4.93), 1.29 (1.03-1.61), and 1.65 (1.27-2.13), respectively. The risk of high Lp(a) was reduced in the HDL-C lowering group with an OR (95% CI) of 0.76 (0.61-0.94). In contrast, an increase in TG levels and the ratio of Apo A1/Apo B(Apo A1/B) was negatively correlated with the risk of high Lp(a), with OR (95% CI) of 0.73 (0.60-0.89) for elevated triglyceride group, and OR (95% CI) of 0.60 (0.50-0.72) for the Apo A1/B ratio increase group (linear trend test P≤0.001 except for Apo A1). However, no correlation was found between Lp(a) levels and lifestyle factors such as diet, smoking, and physical activity. Conclusions:Lp(a) levels were associated with sex and abdominal obesity, but less with lifestyle behaviors.

Result Analysis
Print
Save
E-mail