1.Clinical research on corneal epithelium remodeling after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis
Yangjing ZHANG ; Liwei MA ; Fan ZHANG ; Chunmei KE ; Ruifu WANG ; Lipye ZU
International Eye Science 2025;25(1):37-41
AIM: To compare the changes in corneal epithelial thickness(CET)after small incision lenticule extraction(SMILE)and femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS: A total of 187 patients(187 eyes)who underwent either SMILE or FS-LASIK at Urumqi Aier Eye Hospital between December 2022 and November 2023 were collected. The patients were divided into SMILE group and FS-LASIK group according to surgical methods. The CET of the patients was measured by optical coherence tomography(OCT)system before surgery and at 1 wk, 1, 3, and 6 mo postoperatively.RESULTS: Changes in corneal epithelial thickness(△CET)in the central, paracentral, and mid-peripheral regions were compared at 6 mo postoperatively. The SMILE group was characterized by the most significant thickening in the central area and the least thickening in the mid-peripheral area; while the FS-LASIK group was characterized by the most significant thickening in the paracentral area and the least thickening in the mid-peripheral region. At 1 wk, 1, 3, and 6 mo postoperatively, within the 0-7 mm corneal area, the △CET for both the SMILE and FS-LASIK groups was correlated with the preoperative spherical equivalent.CONCLUSION: Within 6 mo postoperatively, both SMILE and FS-LASIK showed a similar trend in epithelial thickening but with distinct characteristics. The change in corneal epithelial thickness for both procedures was positively correlated with the preoperative diopter.
2.Effects of long working hours, shift rotation, and job stress on work-related musculoskeletal disorders among key occupational populations in Yunnan Province
Jun QI ; Jingjing CAO ; Meifeng ZHOU ; Ke ZHU ; Xingren LIU ; Linbo FAN
Journal of Environmental and Occupational Medicine 2025;42(3):302-309
Background The adverse effects of long working hours, shift rotation, and job stress on the physical and mental health of occupational populations require urgent attention. Objective To investigate and compare the positive rates of WMSDs between different industries, analyze the exposure status of long working hours, shift rotation, and job stress among key occupational groups, and evaluate the impacts of these factors on WMSDs in the manufacturing and service industries. Methods The study subjects were derived from key occupational populations in Yunnan Province, recruited by the Chinese National Occupational Health Literacy Monitoring Survey in 2022. A cross-sectional design was used for this survey. The key occupational populations were recruited from the secondary industry (manufacturing industry, metal mining and beneficiation industry, and non-metal mining and beneficiation industry) by stratified random sampling and from the tertiary industry (medical and healthcare industry, education industry, environmental sanitation industry, transportation industry, and express/takeaway delivery industry) by proportional probability sampling, and
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Application and Advance of Image Compression Algorithms in Medical Imaging
Jiawen SHANG ; Peng HUANG ; Zhixing CHANG ; Yuhan FAN ; Zhihui HU ; Ke ZHANG ; Jianrong DAI ; Hui YAN
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1281-1290
Medical imaging technology plays a crucial role in clinical diagnosis and treatment. Image compression technology provides robust technical support for the storage and transmission of massive medical imaging data, serving as an effective safeguard for hospital data backup and telemedicine. The technology holds broad application prospects in the medical field, enabling the processing of various imaging modalities, multidimensional imaging, and medical video imaging. This study elaborates on general image and video compression algorithms, the application of compression algorithms in the medical field, and the performance metrics of medical image compression, thereby providing critical technical support for enhancing clinical diagnostic efficiency and data management security.
9.Specific DNA barcodes screening, germplasm resource identification, and genetic diversity analysis of Platycodon grandiflorum
Xin WANG ; Yue SHI ; Jin-hui MAN ; Yu-ying HUANG ; Xiao-qin ZHANG ; Ke-lu AN ; Gao-jie HE ; Zi-qi LIU ; Fan-yuan GUAN ; Yu-yan ZHENG ; Xiao-hui WANG ; Sheng-li WEI
Acta Pharmaceutica Sinica 2024;59(1):243-252
Platycodonis Radix is the dry root of
10.Intravenous thrombolysis in patients with stroke warning syndrome: comparison with antiplatelet therapy
Ke ZHU ; Yanyan LI ; Jianrui LI ; Xinhong FAN ; Jinyan LI ; Tong FAN ; Dan GUO
International Journal of Cerebrovascular Diseases 2024;32(1):27-32
Objective:To investigate the efficacy and safety of intravenous thrombolysis and antiplatelet therapy in patients with stroke warning syndrome (SWS), as well as influencing factors of the outcome in patients with SWS.Method:Patients with SWS admitted to the 521 st Hospital of Ordnance Group from June 1, 2018 to December 31, 2023 were retrospectively included. Some patients were treated with ateplase intravenous thrombolysis, followed by oral antiplatelet therapy; some patients only received antiplatelet therapy. The main outcome measure was the modified Rankin Scale score at 90 days after onset, with a score of 0-2 defined as good outcome. Results:A total of 35 patients with SWS were included, including 26 males (74.3%) with an age of 58.29±11.06 years. Nineteen patients (54.3%) received intravenous thrombolysis, and 27 (77.1%) had good outcome at 90 days. There was no statistically significant difference in demographic, baseline data, and good outcome between the intravenous thrombolysis group and the antiplatelet therapy group. One patient had new stroke and one had transient ischemic attack in the intravenous thrombolysis group. There were statistically significant differences in ABCD2 score, systolic blood pressure, low-density lipoprotein cholesterol, fasting blood glucose, highest National Institutes of Health Stroke Scale (NIHSS) score at onset, and symptom duration between the good outcome group and the poor outcome group (all P<0.05). Conclusions:The efficacy of intravenous thrombolysis is similar to that of antiplatelet drugs alone in treating SWS. ABCD2 score, systolic blood pressure, low-density lipoprotein cholesterol, fasting blood glucose, highest NIHSS score at onset, and duration of symptoms may be influencing factors for the outcome of patients with SWS.

Result Analysis
Print
Save
E-mail