1.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
		                        		
		                        			 Purpose:
		                        			This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. 
		                        		
		                        			Materials and Methods:
		                        			The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. 
		                        		
		                        			Results:
		                        			For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. 
		                        		
		                        			Conclusion
		                        			These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA. 
		                        		
		                        		
		                        		
		                        	
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
		                        		
		                        			 Purpose:
		                        			This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. 
		                        		
		                        			Materials and Methods:
		                        			The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. 
		                        		
		                        			Results:
		                        			For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. 
		                        		
		                        			Conclusion
		                        			These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA. 
		                        		
		                        		
		                        		
		                        	
3.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
		                        		
		                        			 Purpose:
		                        			This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. 
		                        		
		                        			Materials and Methods:
		                        			The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. 
		                        		
		                        			Results:
		                        			For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. 
		                        		
		                        			Conclusion
		                        			These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA. 
		                        		
		                        		
		                        		
		                        	
4.Eligibility for Lecanemab Treatment in the Republic of Korea:Real-World Data From Memory Clinics
Sung Hoon KANG ; Jee Hyang JEONG ; Jung-Min PYUN ; Geon Ha KIM ; Young Ho PARK ; YongSoo SHIM ; Seong-Ho KOH ; Chi-Hun KIM ; Young Chul YOUN ; Dong Won YANG ; Hyuk-je LEE ; Han LEE ; Dain KIM ; Kyunghwa SUN ; So Young MOON ; Kee Hyung PARK ; Seong Hye CHOI
Journal of Clinical Neurology 2025;21(3):182-189
		                        		
		                        			 Background:
		                        			and Purpose We aimed to determine the proportion of Korean patients with early Alzheimer’s disease (AD) who are eligible to receive lecanemab based on the United States Appropriate Use Recommendations (US AUR), and also identify the barriers to this treatment. 
		                        		
		                        			Methods:
		                        			We retrospectively enrolled 6,132 patients with amnestic mild cognitive impairment or mild amnestic dementia at 13 hospitals from June 2023 to May 2024. Among them, 2,058 patients underwent amyloid positron emission tomography (PET) and 1,199 (58.3%) of these patients were amyloid-positive on PET. We excluded 732 patients who did not undergo brain magnetic resonance imaging between June 2023 and May 2024. Finally, 467 patients were included in the present study. 
		                        		
		                        			Results:
		                        			When applying the criteria of the US AUR, approximately 50% of patients with early AD were eligible to receive lecanemab treatment. Among the 467 included patients, 36.8% did not meet the inclusion criterion of a Mini-Mental State Examination (MMSE) score of ≥22. 
		                        		
		                        			Conclusions
		                        			Eligibility for lecanemab treatment was not restricted to Korean patients with early AD except for those with an MMSE score of ≥22. The MMSE criteria should therefore be reconsidered in areas with a higher proportion of older people, who tend to have lower levels of education. 
		                        		
		                        		
		                        		
		                        	
5.Eligibility for Lecanemab Treatment in the Republic of Korea:Real-World Data From Memory Clinics
Sung Hoon KANG ; Jee Hyang JEONG ; Jung-Min PYUN ; Geon Ha KIM ; Young Ho PARK ; YongSoo SHIM ; Seong-Ho KOH ; Chi-Hun KIM ; Young Chul YOUN ; Dong Won YANG ; Hyuk-je LEE ; Han LEE ; Dain KIM ; Kyunghwa SUN ; So Young MOON ; Kee Hyung PARK ; Seong Hye CHOI
Journal of Clinical Neurology 2025;21(3):182-189
		                        		
		                        			 Background:
		                        			and Purpose We aimed to determine the proportion of Korean patients with early Alzheimer’s disease (AD) who are eligible to receive lecanemab based on the United States Appropriate Use Recommendations (US AUR), and also identify the barriers to this treatment. 
		                        		
		                        			Methods:
		                        			We retrospectively enrolled 6,132 patients with amnestic mild cognitive impairment or mild amnestic dementia at 13 hospitals from June 2023 to May 2024. Among them, 2,058 patients underwent amyloid positron emission tomography (PET) and 1,199 (58.3%) of these patients were amyloid-positive on PET. We excluded 732 patients who did not undergo brain magnetic resonance imaging between June 2023 and May 2024. Finally, 467 patients were included in the present study. 
		                        		
		                        			Results:
		                        			When applying the criteria of the US AUR, approximately 50% of patients with early AD were eligible to receive lecanemab treatment. Among the 467 included patients, 36.8% did not meet the inclusion criterion of a Mini-Mental State Examination (MMSE) score of ≥22. 
		                        		
		                        			Conclusions
		                        			Eligibility for lecanemab treatment was not restricted to Korean patients with early AD except for those with an MMSE score of ≥22. The MMSE criteria should therefore be reconsidered in areas with a higher proportion of older people, who tend to have lower levels of education. 
		                        		
		                        		
		                        		
		                        	
6.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
		                        		
		                        			 Purpose:
		                        			This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. 
		                        		
		                        			Materials and Methods:
		                        			The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. 
		                        		
		                        			Results:
		                        			For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. 
		                        		
		                        			Conclusion
		                        			These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA. 
		                        		
		                        		
		                        		
		                        	
7.Eligibility for Lecanemab Treatment in the Republic of Korea:Real-World Data From Memory Clinics
Sung Hoon KANG ; Jee Hyang JEONG ; Jung-Min PYUN ; Geon Ha KIM ; Young Ho PARK ; YongSoo SHIM ; Seong-Ho KOH ; Chi-Hun KIM ; Young Chul YOUN ; Dong Won YANG ; Hyuk-je LEE ; Han LEE ; Dain KIM ; Kyunghwa SUN ; So Young MOON ; Kee Hyung PARK ; Seong Hye CHOI
Journal of Clinical Neurology 2025;21(3):182-189
		                        		
		                        			 Background:
		                        			and Purpose We aimed to determine the proportion of Korean patients with early Alzheimer’s disease (AD) who are eligible to receive lecanemab based on the United States Appropriate Use Recommendations (US AUR), and also identify the barriers to this treatment. 
		                        		
		                        			Methods:
		                        			We retrospectively enrolled 6,132 patients with amnestic mild cognitive impairment or mild amnestic dementia at 13 hospitals from June 2023 to May 2024. Among them, 2,058 patients underwent amyloid positron emission tomography (PET) and 1,199 (58.3%) of these patients were amyloid-positive on PET. We excluded 732 patients who did not undergo brain magnetic resonance imaging between June 2023 and May 2024. Finally, 467 patients were included in the present study. 
		                        		
		                        			Results:
		                        			When applying the criteria of the US AUR, approximately 50% of patients with early AD were eligible to receive lecanemab treatment. Among the 467 included patients, 36.8% did not meet the inclusion criterion of a Mini-Mental State Examination (MMSE) score of ≥22. 
		                        		
		                        			Conclusions
		                        			Eligibility for lecanemab treatment was not restricted to Korean patients with early AD except for those with an MMSE score of ≥22. The MMSE criteria should therefore be reconsidered in areas with a higher proportion of older people, who tend to have lower levels of education. 
		                        		
		                        		
		                        		
		                        	
8.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
		                        		
		                        			 Purpose:
		                        			This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. 
		                        		
		                        			Materials and Methods:
		                        			The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. 
		                        		
		                        			Results:
		                        			For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. 
		                        		
		                        			Conclusion
		                        			These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA. 
		                        		
		                        		
		                        		
		                        	
9.Exercise improves muscle mitochondrial dysfunction-associated lipid profile under circadian rhythm disturbance
Yu GU ; Dong-Hun SEONG ; Wenduo LIU ; Zilin WANG ; Yong Whi JEONG ; Jae-Cheol KIM ; Dae Ryong KANG ; Rose Ji Eun LEE ; Jin-Ho KOH ; Sang Hyun KIM
The Korean Journal of Physiology and Pharmacology 2024;28(6):515-526
		                        		
		                        			
		                        			 We investigated whether endurance exercise training (EXT) ameliorates circadian rhythm (CR)-induced risk factors by improving skeletal muscle (SKM) mitochondrial biogenesis, reducing oxidative stress, and modulating apoptotic protein expression. We distinguished between regular and shift workers using the National Health and Nutrition Examination Survey (NHANES) and investigated the health problems caused by shift work (CR disturbance) and the potential therapeutic effects of exercise. In our animal study, 36 rats underwent 12 weeks of CR disturbance, divided into regular and irregular CR groups. These groups were further split into EXT (n = 12) and sedentary (n = 12) for an additional 8 weeks. We analyzed SKM tissue to understand the molecular changes induced by CR and EXT. NHANES data were analyzed using SAS 9.4 and Prism 8 software, while experimental animal data were analyzed using Prism 8 software. The statistical procedures used in each experiment are indicated in the figure legends. Our studies showed that CR disturbance increases dyslipidemia, alters circadian clock proteins (BMAL1, PER2), raises apoptotic protein levels, and reduces mitochondrial biogenesis in SKM. EXT improved LDL-C and HDLC levels without affecting muscle BMAL1 expression. It also enhanced mitochondrial biogenesis (AMPK, PGC-1α, Tfam, NADH-UO, COX-I), antioxidant levels (Catalase, SOD1, SOD2), and apoptotic protein (p53, Bax/Bcl2) expression or activity in SKM. We demonstrated that shift work-induced CR disturbance leads to dyslipidemia, diminished mitochondrial biogenesis, and reduced antioxidant capacity in SKM. However, EXT can counteract dyslipidemia under CR disturbance, potentially lowering the risk of cardiovascular disorders. 
		                        		
		                        		
		                        		
		                        	
10.Exercise improves muscle mitochondrial dysfunction-associated lipid profile under circadian rhythm disturbance
Yu GU ; Dong-Hun SEONG ; Wenduo LIU ; Zilin WANG ; Yong Whi JEONG ; Jae-Cheol KIM ; Dae Ryong KANG ; Rose Ji Eun LEE ; Jin-Ho KOH ; Sang Hyun KIM
The Korean Journal of Physiology and Pharmacology 2024;28(6):515-526
		                        		
		                        			
		                        			 We investigated whether endurance exercise training (EXT) ameliorates circadian rhythm (CR)-induced risk factors by improving skeletal muscle (SKM) mitochondrial biogenesis, reducing oxidative stress, and modulating apoptotic protein expression. We distinguished between regular and shift workers using the National Health and Nutrition Examination Survey (NHANES) and investigated the health problems caused by shift work (CR disturbance) and the potential therapeutic effects of exercise. In our animal study, 36 rats underwent 12 weeks of CR disturbance, divided into regular and irregular CR groups. These groups were further split into EXT (n = 12) and sedentary (n = 12) for an additional 8 weeks. We analyzed SKM tissue to understand the molecular changes induced by CR and EXT. NHANES data were analyzed using SAS 9.4 and Prism 8 software, while experimental animal data were analyzed using Prism 8 software. The statistical procedures used in each experiment are indicated in the figure legends. Our studies showed that CR disturbance increases dyslipidemia, alters circadian clock proteins (BMAL1, PER2), raises apoptotic protein levels, and reduces mitochondrial biogenesis in SKM. EXT improved LDL-C and HDLC levels without affecting muscle BMAL1 expression. It also enhanced mitochondrial biogenesis (AMPK, PGC-1α, Tfam, NADH-UO, COX-I), antioxidant levels (Catalase, SOD1, SOD2), and apoptotic protein (p53, Bax/Bcl2) expression or activity in SKM. We demonstrated that shift work-induced CR disturbance leads to dyslipidemia, diminished mitochondrial biogenesis, and reduced antioxidant capacity in SKM. However, EXT can counteract dyslipidemia under CR disturbance, potentially lowering the risk of cardiovascular disorders. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail