1.Genomics-driven derivatization of the bioactive fungal sesterterpenoid variecolin: Creation of an unnatural analogue with improved anticancer properties.
Dexiu YAN ; Jemma ARAKELYAN ; Teng WAN ; Ritvik RAINA ; Tsz Ki CHAN ; Dohyun AHN ; Vladimir KUSHNAREV ; Tsz Kiu CHEUNG ; Ho Ching CHAN ; Inseo CHOI ; Pui Yi HO ; Feijun HU ; Yujeong KIM ; Hill Lam LAU ; Ying Lo LAW ; Chi Seng LEUNG ; Chun Yin TONG ; Kai Kap WONG ; Wing Lam YIM ; Nikolay S KARNAUKHOV ; Richard Y C KONG ; Maria V BABAK ; Yudai MATSUDA
Acta Pharmaceutica Sinica B 2024;14(1):421-432
A biosynthetic gene cluster for the bioactive fungal sesterterpenoids variecolin ( 1) and variecolactone ( 2) was identified in Aspergillus aculeatus ATCC 16872. Heterologous production of 1 and 2 was achieved in Aspergillus oryzae by expressing the sesterterpene synthase VrcA and the cytochrome P450 VrcB. Intriguingly, the replacement of VrcB with homologous P450s from other fungal terpenoid pathways yielded three new variecolin analogues ( 5- 7). Analysis of the compounds' anticancer activity in vitro and in vivo revealed that although 5 and 1 had comparable activities, 5 was associated with significantly reduced toxic side effects in cancer-bearing mice, indicating its potentially broader therapeutic window. Our study describes the first tests of variecolin and its analogues in animals and demonstrates the utility of synthetic biology for creating molecules with improved biological activities.
2.Effects of Zhuangyao Shuanglu Tongnao Formula on neuronal apoptosis of rats with ischemia-reperfusion induced injury
Yang ZHAI ; Xue-Ni MO ; Hong-Li TENG ; Yue-Qiang HU ; Guang-Shan ZHENG ; Wei MA ; Peng YANG ; Xiao-Ping MEI ; Min ZOU ; Kai-Hua WANG
Chinese Traditional Patent Medicine 2024;46(3):795-802
AIM To investigate the effects of Zhuangyao Shuanglu Tongnao Formula on neuronal apoptosis in rats with cerebral ischemia-reperfusion injury based on the study of oxidative stress and inflammatory response.METHODS The rats were randomly divided into the sham operation group,the model group,the edaravone group(3.0 mg/kg),the low,medium and high dose groups(9.0,18.0,36.0 g/kg)of Zhuangyao Shuanglu Tongnao Formula,with 18 rats in each group.The middle cerebral artery occlusion/reperfusion was conducted by thread embolism method to simulate cerebral ischemia reperfusion injury in rats followed by 6 days corresponding drugs administration.Subsequently,the rats had their neurological function deficit scored by Zeal Longa scoring method;their sizes of cerebral infarction areas measured by TTC staining;their pathological damage and apoptosis of neurons in hippocampal CA1 area of ischemic penumbra of the brain tissue detected by HE staining and TUNEL staining;their SOD activity and levels of GSH,MDA,IL-6,IL-1β,TNF-α in brain tissue detected by kits;and their protein expressions of Bax,Bcl-2,caspase-3,cleaved-capase-3,TLR4,NF-κB p65,Nrf2,HO-1 in rat brain tissue determined by Western blot.RESULTS Compared with the model group,the groups intervened with edaravone,medium and high dose of Zhuangyao Shuanglu Tongnao Formula displayed improvements in the scores of nerve function defects,the rate of cerebral infarction,the rate of neuronal apoptosis,the levels of IL-6,IL-1β,TNF-α and MDA in the ischemic penumbra of brain tissues,the protein expressions of Bax and TLR4,the ratio of cleaved-capase-3/caspase-3 and p-NF-κB p65/NF-κB p65(P<0.05),the levels of GSH,the activity of SOD and the protein expressions of Bcl-2,Nrf2 and HO-1(P<0.05).CONCLUSION Being an inhibitor of oxidative stress and inflammatory response,Zhuangyao Shuanglu Tongnao Formula can alleviate brain injury in rats with cerebral ischemia reperfusion injury through the inhibition of neuronal apoptosis and improvement of neural function mediated by the inhibition of TLR4/NF-κB signal pathway and activation of Nrf2/HO-1 signal pathway.
3.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.
4.Orthopaedic robot assisted closed reduction and cannulated screw internal fixation for the treatment of femoral neck fractures
Shou-Hai JIANG ; Chuan-Kai ZHANG ; Fang-Teng JIA ; Qiang CHEN ; Meng XU ; Pei-Lin YANG ; Yu-Shuai ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(2):119-123
Objective To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixa-tion for femoral neck fracture assisted by robot navigation and positioning system.Methods From July 2019 to January 2020,16 cases of femoral neck fracture(navigation group)were treated with closed reduction and internal fixation guided by robot system,including 7 males and 9 females,aged 25 to 72 years old with an average of(53.61±5.45)years old;Garden classification of fracture:3 cases of type Ⅰ,3 cases of type Ⅱ,8 cases of type Ⅲ,2 cases of type Ⅳ.Non navigation group(control group):20 cases of femoral neck fracture were treated with closed reduction and hollow nail internal fixation,8 males and 12 females,aged 46 to 70 years old with an average of(55.23±4.64)years old;Garden type Ⅰ in 2 cases,type Ⅱ in 4 cases,type Ⅲ in 11 cases,type Ⅳ in 3 cases.The operation time,fluoroscopy times,guide needle drilling times,screw adjustment times,intraoperative bleeding volume and other indicators of two groups were evaluated.Results Both groups were followed up for 12 to 18 months with an average of(15.6±2.8)months.The fractures of both groups were healed without delayed union and nonunion.There was no significant difference in healing time between two groups(P=0.782).There was no significant differ-ence in Harris scores between two groups at the last follow-up(P=0.813).There was no significant difference in operation time between two groups(P>0.05).There were significant differences between two groups in fluoroscopy times,guide needle drilling times,hollow screw replacement times,and intraoperative bleeding volume(P<0.05).Conclusion Closed reduction and hollow screw internal fixation assisted by robot navigation system for femoral neck fracture has the advantages of minimally invasive operation,precise screw placement,and reduction of X-ray radiation damage during operation.
5.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.
6.Application of in vivo brain imaging technology in the basic research of acupuncture-moxibustion for encephalopathy.
Xu WANG ; Zheng-Cui FAN ; Zhen ZHANG ; Bo-Kai WANG ; Fei-Xue WANG ; Teng HE ; Xiu-Min JIANG ; Jing-Lan YAN ; Yong-Jun CHEN
Chinese Acupuncture & Moxibustion 2023;43(12):1363-1369
Acupuncture-moxibustion is remarkably effective on encephalopathy, but its mechanism is unclear. With the continuous development of imaging technology, the in vivo brain imaging technology has been used increasingly in life science research and it also becomes a more effective tool for the basic research of acupuncture-moxibustion in treatment of encephalopathy. The paper summarizes the application of its technology in the basic research of acupuncture-moxibustion for encephalopathy and the characteristics of imaging, as well as the advantages and shortcomings. It is anticipated that the references may be provided for the basic research of acupuncture-moxibustion in treatment of encephalopathy and be conductive to the modernization of acupuncture-moxibustion.
Humans
;
Moxibustion
;
Acupuncture Therapy
;
Acupuncture
;
Brain Diseases/therapy*
;
Neuroimaging
7.Comparison of different ureteral length measurement methods in the indwelling of double-J stent after ureteroscopy
Yongchuan WANG ; Yuhang BI ; Anji REN ; Xiaolu LUN ; Jing DU ; Haijun ZHOU ; Kai WANG ; Zhiyong YU ; Wenshun LIU ; Teng SHEN ; Yi SHAO
Journal of Modern Urology 2023;28(2):106-110
【Objective】 To investigate the application of different ureteral length measurement methods in the indwelling of double-J stent. 【Methods】 Clinical data of 260 patients with double-J stent indwelling after ureteroscopic surgery during Jul.2018 and Dec.2020 were prospectively analyzed. The patients were randomly divided into height calculation group, CT measurement group, KUB group and ureteroscopic measurement group. The length of ureter was calculated accordingly and the appropriate length of double-J stent was selected. KUB was performed on the first day after operation and before extubation to determine the position of double-J stent. The patients completed the ureteral stent-related symptom questionnaire (USSQ), urinary symptom score, lower urinary tract symptom (LUTS) score, pain score, hematuria score, and quality of life score before and after double-J catheter placement. 【Results】 There were no significant differences in age, gender, height, side of stent and urinary symptom score among the four groups (P>0.05). The average lengths of the ureters measured by the four methods were (21.5±1.0) cm, (21.5±1.8) cm, (23.8±1.3) cm and (21.7±1.8) cm, respectively. There were no significant differences among the height calculation group, CT measurement group and ureteroscope group, but there was significant difference between the three groups and the KUB group. The ideal ureteral stent length indwelling ratio in the ureteroscopic group was 76.9%, which was better than that in the other three groups. Postoperative indwelling time was 7-42 d (mean 29.8 d). The USSQ score of the ureteroscopic group before extubation was (14.1±1.5), which was lower than that of the other three groups (P<0.05). The ureteroscopic group was better than the other three groups in the comparison of frequency and urgency of urination, nocturia, hematuria, quality of life score, and pain score (P<0.05). 【Conclusion】 Intraoperative ureteroscopic measurement of the ureteral length is a simple and feasible method in guiding the indwelling of double-J stent to reduce ureteral stent related symptoms.
9.Global incidence and prevalence of nonalcoholic fatty liver disease
Margaret LP TENG ; Cheng Han NG ; Daniel Q. HUANG ; Kai En CHAN ; Darren JH TAN ; Wen Hui LIM ; Ju Dong YANG ; Eunice TAN ; Mark D. MUTHIAH
Clinical and Molecular Hepatology 2023;29(Suppl):S32-S42
Nonalcoholic fatty liver disease (NAFLD) is a leading cause of liver disease worldwide. The estimated global incidence of NAFLD is 47 cases per 1,000 population and is higher among males than females. The estimated global prevalence of NAFLD among adults is 32% and is higher among males (40%) compared to females (26%). The global prevalence of NAFLD has increased over time, from 26% in studies from 2005 or earlier to 38% in studies from 2016 or beyond. The prevalence of NAFLD varies substantially by world region, contributed by differing rates of obesity, and genetic and socioeconomic factors. The prevalence of NAFLD exceeds 40% in the Americas and South-East Asia. The prevalence of NAFLD is projected to increase significantly in multiple world regions by 2030 if current trends are left unchecked. In this review, we discuss trends in the global incidence and prevalence of NAFLD and discuss future projections.
10.Advances in surgical strategies for ossification of posterior longitudinal ligament involving the C 2 segment.
Teng LIU ; Guoning GU ; Chenguang ZHAN ; Haishan LI ; Huizhi GUO ; Yongxian LI ; Guoye MO ; Kai YUAN ; Shuncong ZHANG ; Zhidong YANG ; Yongchao TANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):742-747
OBJECTIVE:
To evaluate the application of surgical strategies for the treatment of cervical ossification of the posterior longitudinal ligament (OPLL) involving the C 2 segment.
METHODS:
The literature about the surgery for cervical OPLL involving C 2 segment was reviewed, and the indications, advantages, and disadvantages of surgery were summarized.
RESULTS:
For cervical OPLL involving the C 2 segments, laminectomy is suitable for patients with OPLL involving multiple segments, often combined with screw fixation, and has the advantages of adequate decompression and restoration of cervical curvature, with the disadvantages of loss of cervical fixed segmental mobility. Canal-expansive laminoplasty is suitable for patients with positive K-line and has the advantages of simple operation and preservation of cervical segmental mobility, and the disadvantages include progression of ossification, axial symptoms, and fracture of the portal axis. Dome-like laminoplasty is suitable for patients without kyphosis/cervical instability and with negative R-line, and can reduce the occurrence of axial symptoms, with the disadvantage of limited decompression. The Shelter technique is suitable for patients with single/double segments and canal encroachment >50% and allows for direct decompression, but is technically demanding and involves risk of dural tear and nerve injury. Double-dome laminoplasty is suitable for patients without kyphosis/cervical instability. Its advantages are the reduction of damage to the cervical semispinal muscles and attachment points and maintenance of cervical curvature, but there is progress in postoperative ossification.
CONCLUSION
OPLL involving the C 2 segment is a complex subtype of cervical OPLL, which is mainly treated through posterior surgery. However, the degree of spinal cord floatation is limited, and with the progress of ossification, the long-term effectiveness is poor. More research is needed to address the etiology of OPLL and to establish a systematic treatment strategy for cervical OPLL involving the C 2 segment.
Humans
;
Longitudinal Ligaments/surgery*
;
Ossification of Posterior Longitudinal Ligament/surgery*
;
Treatment Outcome
;
Osteogenesis
;
Decompression, Surgical/methods*
;
Cervical Vertebrae/surgery*
;
Laminoplasty/methods*
;
Kyphosis/surgery*
;
Retrospective Studies

Result Analysis
Print
Save
E-mail