1.2021 Asian Pacific Society of Cardiology Consensus Recommendations on the use of P2Y12 receptor antagonists in the Asia-Pacific Region: Special populations.
W E I C H I E H T A N TAN ; P C H E W CHEW ; L A M T S U I TSUI ; T A N TAN ; D U P L Y A K O V DUPLYAKOV ; H A M M O U D E H HAMMOUDEH ; Bo ZHANG ; Yi LI ; Kai XU ; J O N G ONG ; Doni FIRMAN ; G A M R A GAMRA ; A L M A H M E E D ALMAHMEED ; D A L A L DALAL ; T A N TAN ; S T E G STEG ; N N G U Y E N NGUYEN ; A K O AKO ; A L S U W A I D I SUWAIDI ; C H A N CHAN ; S O B H Y SOBHY ; S H E H A B SHEHAB ; B U D D H A R I BUDDHARI ; Zu Lv WANG ; Y E A N Y I P F O N G FONG ; K A R A D A G KARADAG ; K I M KIM ; B A B E R BABER ; T A N G C H I N CHIN ; Ya Ling HAN
Chinese Journal of Cardiology 2023;51(1):19-31
2.Updated New York City Emergency Medical Services Acute Stroke Triage Protocol Reduces Interfacility Transfers and Time to Endovascular Thrombectomy for Emergent Large Vessel Occlusion Stroke Patients
Jacob R. MOREY ; Brian D. KIM ; Michael REDLENER ; Xiangnan ZHANG ; Naoum Fares MARAYATI ; Stavros MATSOUKAS ; Emily FIANO ; Laura K. STEIN ; J MOCCO ; Johanna T. FIFI
Journal of Stroke 2022;24(3):417-420
3.Five-Class Classification of Cervical Pap Smear Images: A Study of CNN-Error-Correcting SVM Models
Audrey K. C. HUONG ; Kim Gaik TAY ; Xavier T. I. NGU
Healthcare Informatics Research 2021;27(4):298-306
Objectives:
Different complex strategies of fusing handcrafted descriptors and features from convolutional neural network (CNN) models have been studied, mainly for two-class Papanicolaou (Pap) smear image classification. This paper explores a simplified system using combined binary coding for a five-class version of this problem.
Methods:
This system extracted features from transfer learning of AlexNet, VGG19, and ResNet50 networks before reducing this problem into multiple binary sub-problems using error-correcting coding. The learners were trained using the support vector machine (SVM) method. The outputs of these classifiers were combined and compared to the true class codes for the final prediction.
Results:
Despite the superior performance of VGG19-SVM, with mean ± standard deviation accuracy and sensitivity of 80.68% ± 2.00% and 80.86% ± 0.45%, respectively, this model required a long training time. There were also false-negative cases using both the VGGNet-SVM and ResNet-SVM models. AlexNet-SVM was more efficient in terms of running speed and prediction consistency. Our findings also showed good diagnostic ability, with an area under the curve of approximately 0.95. Further investigation also showed good agreement between our research outcomes and that of the state-of-the-art methods, with specificity ranging from 93% to 100%.
Conclusions
We believe that the AlexNet-SVM model can be conveniently applied for clinical use. Further research could include the implementation of an optimization algorithm for hyperparameter tuning, as well as an appropriate selection of experimental design to improve the efficiency of Pap smear image classification.
4.An ultrasound-guided fascia iliaca catheter technique does not impair ambulatory ability within a clinical pathway for total hip arthroplasty
Seshadri C. MUDUMBAI ; T. Edward KIM ; Steven K. HOWARD ; Nicholas J. GIORI ; Steven WOOLSON ; Toni GANAWAY ; Alex KOU ; Robert KING ; Edward R. MARIANO
Korean Journal of Anesthesiology 2020;73(3):267-267
5.Utility of a modified components separation for abdominal wall reconstruction in the liver and kidney transplant population
Cara K BLACK ; Elizabeth G ZOLPER ; Elliot T WALTERS ; Jessica WANG ; Jesus MARTINEZ ; Andrew TRAN ; Iram NAZ ; Vikas KOTHA ; Paul J KIM ; Sarah R SHER ; Karen K EVANS
Archives of Plastic Surgery 2019;46(5):462-469
BACKGROUND: Incisional hernia is a common complication following visceral organ transplantation. Transplant patients are at increased risk of primary and recurrent hernias due to chronic immune suppression and large incisions. We conducted a retrospective review of patients with a history of liver or kidney transplantation who underwent hernia repair to analyze outcomes and hernia recurrence. METHODS: This is a single center, retrospective review of 19 patients who received kidney and/or liver transplantation prior to presenting with an incisional hernia from 2011 to 2017. All hernias were repaired with open component separation technique (CST) with biologic mesh underlay. RESULTS: The mean age of patients was 61.0±8.3 years old, with a mean body mass index of 28.4±4.8 kg/m², 15 males (78.9%), and four females (21.1%). There were seven kidney, 11 liver, and one combined liver and kidney transplant patients. The most common comorbidities were hypertension (16 patients, 84.2%), diabetes (9 patients, 47.4%), and tobacco use (8 patients, 42.1%). Complications occurred in six patients (31.6%) including hematoma (1/19), abscess (1/19), seroma (2/19), and hernia recurrence (3/19) at mean follow-up of 28.7±22.8 months. With the exception of two patients with incomplete follow-up, all patients healed at a median time of 27 days. CONCLUSIONS: This small, retrospective series of complex open CST in transplant patients shows acceptable rates of long-term hernia recurrence and healing. By using a multidisciplinary approach for abdominal wall reconstruction, we believe that modified open CST with biologic mesh is a safe and effective technique in the transplant population with complex abdominal hernias.
Abdominal Wall
;
Abscess
;
Body Mass Index
;
Comorbidity
;
Female
;
Follow-Up Studies
;
Hematoma
;
Hernia
;
Hernia, Abdominal
;
Herniorrhaphy
;
Humans
;
Hypertension
;
Immunosuppression
;
Incisional Hernia
;
Kidney Transplantation
;
Kidney
;
Liver Transplantation
;
Liver
;
Male
;
Organ Transplantation
;
Recurrence
;
Retrospective Studies
;
Seroma
;
Surgical Mesh
;
Tobacco Use
;
Transplants
6.Virtual reality distraction decreases routine intravenous sedation and procedure-related pain during preoperative adductor canal catheter insertion: a retrospective study.
Pooja G PANDYA ; T Edward KIM ; Steven K HOWARD ; Erica STARY ; Jody C LENG ; Oluwatobi O HUNTER ; Edward R MARIANO
Korean Journal of Anesthesiology 2017;70(4):439-445
BACKGROUND: Virtual reality (VR) distraction is a nonpharmacological method to prevent acute pain that has not yet been thoroughly explored for anesthesiology. We present our experience using VR distraction to decrease routine intravenous sedation for patients undergoing preoperative perineural catheter insertion. METHODS: This 1-month quality improvement project involved all elective unilateral primary total knee arthroplasty patients who received a preoperative adductor canal catheter. Clinical data were analyzed retrospectively. For the first half of the month, all patients received usual care; intravenous sedation was administered at the discretion of the regional anesthesiologist. For the second half of the month, patients were offered VR distraction with intravenous sedation upon request. The primary outcome was fentanyl dosage; other outcomes included midazolam dosage, procedure-related pain, procedural time, and blood pressure changes. RESULTS: Seven patients received usual care and seven used VR. In the VR group, 1/7 received intravenous sedation versus 6/7 who received usual care (P = 0.029). The fentanyl dose was lower (median [10th–90th percentiles]) in the VR group (0 [0–20] µg) versus the non-VR group (50 [30–100] µg; P = 0.008). Midazolam use was lower in the VR group (0 [0–0] mg) than in the non-VR group (1 [0–1] mg; P = 0.024). Procedure-related pain was lower in the VR group (1 [1–4] NRS) versus the non-VR group (3 [2–6] NRS; P = 0.032). There was no difference in other outcomes. CONCLUSIONS: VR distraction may provide an effective nonpharmacological alternative to intravenous sedation for the ultrasound-guided placement of certain perineural catheters.
Acute Pain
;
Analgesics, Opioid
;
Anesthesia, Conduction
;
Anesthesiology
;
Arthroplasty, Replacement, Knee
;
Blood Pressure
;
Catheters*
;
Fentanyl
;
Humans
;
Methods
;
Midazolam
;
Quality Improvement
;
Retrospective Studies*
;
Ultrasonography
7.Implementation of clinical practice changes by experienced anesthesiologists after simulation-based ultrasound-guided regional anesthesia training.
T Edward KIM ; Toni GANAWAY ; T Kyle HARRISON ; Steven K HOWARD ; Cynthia SHUM ; Alex KUO ; Edward R MARIANO
Korean Journal of Anesthesiology 2017;70(3):318-326
BACKGROUND: Anesthesiologists who have finished formal training and want to learn ultrasound-guided regional anesthesia (UGRA) commonly attend 1 day workshops. However, it is unclear whether participation actually changes clinical practice. We assessed change implementation after completion of a 1 day simulation-based UGRA workshop. METHODS: Practicing anesthesiologists who participated in a 1 day UGRA course from January 2012 through May 2014 were surveyed. The course consisted of clinical observation of UGRA procedures, didactic lectures, ultrasound scanning, hands-on perineural catheter placement, and mannequin simulation. The primary outcome was the average number of UGRA blocks per month reported at follow-up versus baseline. Secondary outcomes included preference for ultrasound as the nerve localization technique, ratings of UGRA teaching methods, and obstacles to performing UGRA. RESULTS: Survey data from 46 course participants (60% response rate) were included for analysis. Participants were (median [10th–90th percentile]) 50 (37–63) years old, had been in practice for 17 (5–30) years, and were surveyed 27 (10–34) months after their UGRA training. Participants reported performing 24 (4–90) blocks per month at follow-up compared to 10 (2–24) blocks at baseline (P < 0.001). Compared to baseline, more participants at follow-up preferred ultrasound for nerve localization. The major obstacle to implementing UGRA in clinical practice was time pressure. CONCLUSIONS: Participation in a 1 day simulation-based UGRA course may increase UGRA procedural volume by practicing anesthesiologists.
Anesthesia, Conduction*
;
Catheters
;
Education
;
Follow-Up Studies
;
Lectures
;
Manikins
;
Nerve Block
;
Teaching
;
Ultrasonography
8.Randomized comparison of popliteal-sciatic perineural catheter tip migration and dislocation in a cadaver model using two catheter designs.
Lauren STEFFEL ; Steven K HOWARD ; Lindsay BORG ; Edward R MARIANO ; Jody C LENG ; T Edward KIM
Korean Journal of Anesthesiology 2017;70(1):72-76
BACKGROUND: New catheter-over-needle (CON) technology for continuous peripheral nerve blockade has emerged, but its effect on the risk of perineural catheter tip dislocation is unknown. Less flexible catheters may be more likely to migrate away from the nerve with simulated patient movement. In the present study, we evaluated catheter tip migration between CON catheters and traditional catheter-through-needle (CTN) catheters during ultrasound-guided short-axis in-plane (SAX-IP) insertion. METHODS: We evaluated the migration of popliteal-sciatic catheters in a prone, unembalmed male cadaver. Thirty catheter placement trials were divided randomly into two groups based on the catheter type: CON or CTN. A single anesthesiology resident placed the catheters by SAX-IP insertion, and the catheters were then examined by ultrasound before and after ipsilateral knee range of motion (ROM) exercises (0°–130° flexion). A blinded expert regional anesthesiologist performed caliper measurements on the ultrasound images before and after the ROM exercises. The primary outcome was the change in distance from the catheter tip to the center of the nerve (cm) between before and after the ROM exercises. RESULTS: The change in the tip-to-nerve distance (median [10th–90th percentile]) was 0.06 (−0.16 to 0.23) cm for the CTN catheter and 0.00 (−0.12 to 0.69) for the CON catheter (P = 0.663). However, there was a statistically significant increase in dislocation out of the nerve compartment for the CON catheter (4/15; 0/15 for CTN) (P = 0.043). CONCLUSIONS: Although the use of different catheter designs had no effect on the change in the measured migration distance of popliteal-sciatic catheters, 27% of the CON catheters were dislocated out of the nerve compartment. These results may influence the choice of catheter design when using SAX-IP perineural catheter insertion.
Anesthesia, Conduction
;
Anesthesiology
;
Cadaver*
;
Catheters*
;
Dislocations*
;
Exercise
;
Humans
;
Knee
;
Male
;
Nerve Block
;
Peripheral Nerves
;
Range of Motion, Articular
;
Sciatic Nerve
;
Ultrasonography
9.Can bedside patient-reported numbness predict postoperative ambulation ability for total knee arthroplasty patients with nerve block catheters?.
Seshadri C MUDUMBAI ; Toni GANAWAY ; T Edward KIM ; Steven K HOWARD ; Nicholas J GIORI ; Cynthia SHUM ; Edward R MARIANO
Korean Journal of Anesthesiology 2016;69(1):32-36
BACKGROUND: Adductor canal catheters offer advantages over femoral nerve catheters for knee replacement patients because they produce less quadriceps muscle weakness; however, applying adductor canal catheters in bedside clinical practice remains challenging. There is currently no patient-reported outcome that accurately predicts patients' physical function after knee replacement. The present study evaluates the validity of a relatively new patient-reported outcome, i.e., a numbness score obtained using a numeric rating scale, and assesses its predictive value on postoperative ambulation. METHODS: We conducted a retrospective cohort study pooling data from two previously-published clinical trials using identical research methodologies. Both studies recruited patients undergoing knee replacement; one studied adductor canal catheters while the other studied femoral nerve catheters. Our primary outcome was patient-reported numbness scores on postoperative day 1. We also examined postoperative day 1 ambulation distance and its association with postoperative numbness using linear regression, adjusting for age, body mass index, and physical status. RESULTS: Data from 94 subjects were included (femoral subjects, n = 46; adductor canal subjects, n = 48). Adductor canal patients reported decreased numbness (median [10th-90th percentiles]) compared to femoral patients (0 [0-5] vs. 4 [0-10], P = 0.001). Adductor canal patients also ambulated seven times further on postoperative day 1 relative to femoral patients. There was a significant association between postoperative day 1 total ambulation distance and numbness (Beta = -2.6; 95% CI: -4.5, -0.8, P = 0.01) with R2 = 0.1. CONCLUSIONS: Adductor canal catheters facilitate improved early ambulation and produce less patient-reported numbness after knee replacement, but the correlation between these two variables is weak.
Arthroplasty*
;
Body Mass Index
;
Catheters*
;
Cohort Studies
;
Early Ambulation
;
Femoral Nerve
;
Humans
;
Hypesthesia*
;
Knee*
;
Linear Models
;
Nerve Block*
;
Quadriceps Muscle
;
Retrospective Studies
;
Walking*
10.An ultrasound-guided fascia iliaca catheter technique does not impair ambulatory ability within a clinical pathway for total hip arthroplasty.
Seshadri C MUDUMBAI ; T Edward KIM ; Steven K HOWARD ; Nicholas J GIORI ; Steven WOOLSON ; Toni GANAWAY ; Alex KOU ; Robert KING ; Edward R MARIANO
Korean Journal of Anesthesiology 2016;69(4):368-375
BACKGROUND: Both neuraxial and peripheral regional analgesic techniques offer postoperative analgesia for total hip arthroplasty (THA) patients. While no single technique is preferred, quadriceps muscle weakness from peripheral nerve blocks may impede rehabilitation. We designed this study to compare postoperative ambulation outcome in THA patients who were treated with a new ultrasound-guided fascia iliaca catheter (FIC) technique or intrathecal morphine (ITM). METHODS: We reviewed the electronic health records of a sequential series of primary unilateral THA patients who were part of a standardized clinical pathway; apart from differences in regional analgesic technique, all other aspects of the pathway were the same. Our primary outcome was total ambulation distance (meters) combined for postoperative days 1 and 2. Secondary outcomes included daily opioid consumption (morphine milligram equivalents) and analgesic-related side effects. We examined the association between the primary outcome and analgesic technique by performing crude and adjusted ordinary least-squares linear regression. A P value < 0.05 was considered statistically-significant. RESULTS: The study analyzed the records of 179 patients (fascia iliaca, n = 106; intrathecal, n = 73). The primary outcome (total ambulation distance) did not differ between the groups (P = 0.08). Body mass index (BMI) was the only factor (β = -1.7 [95% CI -0.5 to -2.9], P < 0.01) associated with ambulation distance. Opioid consumption did not differ, while increased pruritus was seen in the intrathecal group (P < 0.01). CONCLUSIONS: BMI affects postoperative ambulation outcome after hip arthroplasty, whereas the type of regional analgesic technique used does not. An ultrasound-guided FIC technique offers similar analgesia with fewer side effects when compared with ITM.
Analgesia
;
Anesthesia, Conduction
;
Anesthesia, Spinal
;
Arthroplasty
;
Arthroplasty, Replacement, Hip*
;
Body Mass Index
;
Catheters*
;
Critical Pathways*
;
Electronic Health Records
;
Fascia*
;
Hip
;
Humans
;
Linear Models
;
Morphine
;
Nerve Block
;
Peripheral Nerves
;
Pruritus
;
Quadriceps Muscle
;
Rehabilitation
;
Ultrasonography
;
Walking

Result Analysis
Print
Save
E-mail