1.TLR4 and IFN - γ Activated Mesenchymal Stem Cells Improve Schistosomiasis Liver Fibrosis by Regulating Macrophage Polarization
Yaojia REN ; Fang CHEN ; Wanxian HUANG ; Zhongdao WU ; Junxia LEI
Journal of Sun Yat-sen University(Medical Sciences) 2025;46(3):410-419
ObjectiveTo investigate whether co-activated mesenchymal stem cells(MSCs) exert therapeutic effects against schistosomiasis by modulating macrophage polarization. MethodsTwenty adult male Balb/c mice were randomly divided into four groups: uninfected, infected, MSC-treated, and MSCTLR4+IFN-γ-treated groups. The Schistosoma japonicum infection model was established via abdominal patch method with cercariae. At week 5 post-infection, praziquantel was administered orally for antiparasitic treatment. At week 6, mice received either MSCs treatments (with or without pre-activation) or no treatment. Body weight changes were monitored weekly. Hepatic pathological alterations were evaluated via HE and Masson staining. RT-qPCR was used to assess α-SMA and collagen (Col-I, Col-Ⅲ) mRNA levels to quantify fibrosis. The mRNA levels of hepatic inflammatory cytokines and matrix metalloproteinases(MMP) were analyzed to explore fibrotic mechanisms. The expressions of i-Nos and Arg-1 in liver tissues were detected by RT-qPCR, and the ratio of M1 or M2 macrophages was detected by immunofluorescence staining, aiming to analyze the correlation between MSCs treatment and macrophage polarization. An in vitro co-culture system validated direct MSC-macrophage interactions. ResultsCompared with the infected group, the MSCTLR4+IFN-γ group exhibited increased body weight gain (P< 0.01), reduced hepatic granulomatous lesion area (P< 0.001), and decreased α-SMA, Col-I, and Col-Ⅲ mRNA levels (P< 0.01). Additionally, the MSCTLR4+IFN-γ group showed reduced TNF-α and IL-1β expression (P< 0.05), as well as elevated MMP2, Mmp9, and MMP13 levels (P< 0.01). The MSCTLR4+IFN-γ group showed higher expression of M2 marker Arg-1 mRNA compared with the infection group (P < 0.001) , while the expression of M1 marker i-Nos decreased (P< 0.05). Immunofluorescence confirmed a lower i-Nos+ cell ratio (P< 0.05) and higher F4/80+CD206+ cell ratio (P< 0.000 1) in the MSCTLR4+IFN-γ group compared with the infection group. In vitro co-culture experiments further demonstrated that MSCTLR4+IFN-γ promoted Arg-1 expression, suppressed pro-inflammatory cytokine i-Nos and TNF-α levels, consistent with ELISA results. ConclusionsThis study reveals that TLR4 and IFN-γ co-activated MSCs alleviate Schistosoma japonicum-induced hepatic fibrosis, potentially through modulating macrophage polarization toward the M2 phenotype. This mechanism may suppress inflammation and enhance extracellular matrix degradation, providing a therapeutic strategy for schistosomiasis-associated liver fibrosis.
2.Treatment of Diabetic Retinopathy with Blood Stasis, Collateral Obstruction, and Qi and Yin Deficiency Syndrome with Tongluo Mingmu Capsules: A Randomized, Double-blind, and Multi-center Phase Ⅲ Clinical Trial
Junxia REN ; Yongzheng WANG ; Xiaofei LIU ; Li SUN ; Libo YANG ; Lie WU ; Fengmei LIAN ; Qiping WEI ; Lijuan WEI ; Jingsheng YU ; Jianke HAN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):170-178
ObjectiveTo evaluate the clinical efficacy and safety of Tongluo Mingmu capsules in the treatment of diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome. MethodA randomized, double-blind, positive-control, and multi-center clinical trial design method was used. 416 patients with diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome in four test centers were included (the ratio of the treatment group to the control group was 3∶1). On the basis of standardized hypoglycemic treatment, the treatment group was given both four Tongluo Mingmu capsules and two Calcium Dobesilate capsule agents three times a day, while the control group were given both two Calcium Dobesilate capsules and four Tongluo Mingmu capsule agents three times a day. The course of treatment was 12 weeks. The curative effect of Tongluo Mingmu capsules was evaluated by comparing the comprehensive curative effect of diabetic retinopathy, traditional Chinese medicine(TCM) syndrome score, corrected visual acuity, fundus changes, fundus fluorescence angiography, and other curative effect indexes before and after treatment in the two groups. At the same time, general examination, laboratory examination, and adverse events were performed to evaluate the safety of the drug. ResultThe baseline demographic data and disease characteristics of the treatment group and the control group were balanced and comparable, with the difference not statistically significant. After 12 weeks of treatment, the total effective rate of the comprehensive curative effect of diabetic retinopathy in the treatment group (61.0%, 189/310) was better than that in the control group (44.1%, 45/102), and the difference was statistically significant (χ2=8.880, P<0.01). The total effective rate of TCM syndromes in the treatment group (88.4%, 259/293) was better than that in the control group (69.9%, 65/93), and the difference was statistically significant (χ2=17.927, P<0.01). The disappearance rate of dry eyes (χ2=8.305), dull complexion (χ2=4.053), lassitude (χ2=10.267), shortness of breath (χ2=8.494), and dry stool (χ2=8.657) in the treatment group was higher than that in the control group, and the difference between the groups was statistically significant (P<0.05, P<0.01). In terms of improving corrected visual acuity (χ2=8.382), fundus changes (χ2=6.026) , the treatment group was significantly better than the control group (P<0.05). During the trial, the incidence of adverse events in the treatment group and the control group was 1.3% and 2.9%, respectively. There was no significant difference between the two groups. In addition, there were no serious adverse events and adverse events leading to withdrawal in both groups. ConclusionTongluo Mingmu capsules can improve the comprehensive curative effect of diabetic retinopathy and enhance the efficacy of TCM syndromes, visual acuity, fundus changes, and fundus fluorescein angiography, with great safety. Therefore, it can provide a new alternative therapeutic drug for patients with diabetic retinopathy.
3.Analysis of driver gene mutations in “Xuanwei” multi-nodular non-small cell lung cancer
WANG Xiaoxionga ; LI Quana ; SHEN Zhenghaib ; CAI Jingjinga ; LI Zhuoyinga ; SHEN Shaoconga ; LI Hongshenga ; LIU Xina ; LIU Xia ; LIU Junxia ; GUO Yinjina ; DU Yaxia ; LAN Yunyia ; MA Luyaoa ; YANG Ruijiaoa ; WU Shunxiana ; ZHOU Yongchuna ; HUANG Yunchaob
Chinese Journal of Cancer Biotherapy 2024;31(4):377-382
[摘 要] 目的:探讨多结节非小细胞肺癌(NSCLC)组织中的驱动基因突变情况与临床病理特征的关系,为多结节NSCLC患者治疗提供分子诊断依据。方法:本研究共纳入2018年1月至2023年10月间云南省肿瘤医院分子诊断中心检测的121例多结节NSCLC患者的253个肺结节肿瘤组织标本,以第二代测序(NGS)技术或扩增阻滞突变系统PCR(ARMS-PCR)技术检测多结节NSCLC 组织中驱动基因突变情况,分析其与患者临床病理特征的关系,比较不同结节间肺癌驱动基因的突变异质性。结果:与非“宣威”NSCLC相比,“宣威”多结节NSCLC患者驱动基因突变具有显著的地域特点,表现在“宣威”患者具有较低(20%)的EGFR敏感突变(L858R、19-del)及较高(27.26%)的EGFR少见突变(主要为G719/S768I、G719);“宣威”多结节NSCLC患者的KRAS突变率(27.27%)亦显著高于非“宣威”患者突变率(12.59%)(P<0.05)。此外,“宣威”多结节NSCLC患者驱动基因突变不一致率高达69.23%,远高于非“宣威”患者驱动基因突变不一致率(55.07%)(P<0.05)。结论:“宣威”多结节NSCLC患者具有较高的EGFR少见突变及KRAS突变率,同一患者不同病灶之间存在更高的驱动基因突变异质性,本研究将为“宣威”多结节NSCLC的诊疗策略提供更多的选择。
4.The feasibility and safety of simultaneous bilateral adrenal vein sampling using 4F-MPA1 catheter via right elbow vein access:preliminary results in 51 patients
Qingan LI ; Qinghe WANG ; Ming YU ; Luhong LI ; Junwei WEN ; Shuangyu SHEN ; Jiali CHU ; Junxia WU ; Yi JIN ; Yuanhao LI
Journal of Interventional Radiology 2024;33(2):176-181
Objective To discuss the feasibility and safety of simultaneous bilateral adrenal vein sampling(AVS)using two 4F-MPA1 catheters via right elbow vein access.Methods A total of 51 consecutive patients with primary aldosteronism,who received simultaneous bilateral AVS using two 4F-MPA1 catheters(one of the two catheters was shaped into pig tail figure)via right elbow vein access at Xiangyang Municipal Central Hospital between October 2021 and October 2022,were enrolled in this study.The used catheter,the success rate of simultaneous bilateral AVS,and the incidence of complications rate were calculated.Results The 4F-MPA1 catheter was used for all of the right AVS,while a specially shaped 4F-MPA1 catheter was used for the main trunk vein AVS of the left adrenal gland and the central vein AVS of the left adrenal gland.The success rate of simultaneous bilateral AVS was 92.2%(47/51).Adrenal hematoma occurred in one patient(1.96%).Conclusion The technique of simultaneous bilateral AVS using two 4F-MPA1 catheters via right elbow vein access is simple to operate,less traumatic,and clinically safe and feasible.However,due to the small sample used in this study,the clinical value of this technique still needs further investigation and verification.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Changes of hippocampal gray matter volume and immune related genes in dizocilpine-induced schizophrenia model rats
Guangxian WU ; Xinzhe DU ; Qi LI ; Yao GAO ; Jinzhi LYU ; Dan WANG ; Junxia LI ; Xiao WANG ; Xinrong LI ; Sha LIU
Chinese Journal of Behavioral Medicine and Brain Science 2023;32(1):2-8
Objective:To investigate the changes of hippocampal gray matter volume and expression of candidate immune related genes in a rat model of schizophrenia established by repeated administration of dizocilpine(MK-801).Methods:Thirty SPF grade Sprague-Dawley male rats at postnatal day 28 were randomly divided into MK-801 medium-dose (0.25 mg/kg) group, MK-801 high-dose(0.50 mg/kg) group and normal saline (5 mL/kg) group according to random number table method, with 10 in each group.Rats were given continuous intraperitoneal administration according to grouping once a day for 14 days.Open field test, novel object recognition test and Y-maze test were used at postnatal day 60 to detect spontaneous activity, exploration ability, anxiety level, object recognition memory ability and spatial working memory of rats, respectively.At postnatal day 67, structural magnetic resonance imaging was used to detect the changes of hippocampal gray matter volume in rat.And at postnatal day 70, qRT-PCR was used to detect the expression of candidate immune-related genes in rat hippocampus.SPSS 25.0 was used for statistical analysis, one-way ANOVA was used for comparison among multiple groups, and Tukey test was used for further pairwise comparisons.Results:(1)The behavioral results showed that there were significant differences in the total movement distance, central area activity time, novel object recognition index, and spontaneous correct alternation rate among the three groups ( F=11.15, 10.11, 13.62, 11.99, all P<0.05). The total movement distances in MK-801 medium-dose group and MK-801 high-dose group ((21.44±2.17) m, (22.87±1.96)m) were higher than that in the normal saline group ((18.70±1.88) m) (both P<0.05). The activity time of the central area in the MK-801 medium-dose group and MK-801 high-dose group((3.24±1.58) s, (2.50±1.32) s) were lower than that of the normal saline group ((6.05±2.48)s) (both P<0.01). Novel object recognition indexes in the MK-801 medium-dose group and MK-801 high-dose group((56.10±3.99)%, (54.00±6.41)%) were both lower than that in the normal saline group ((65.90±5.65)%)(both P<0.01), and the rates of spontaneous correct alternation ((54.60±7.03)%, (51.60±8.84)%) in the two groups were lower than that of the normal saline group ((68.40±8.57)%) (both P<0.01). (2) The results of structural magnetic resonance imaging showed that there were significant differences in the volume of hippocampal gray matter among the three groups ( F=9.24, P<0.001). The volumes of hippocampal gray matter in MK-801 medium-dose group and MK-801 high-dose group were lower than that in normal saline group(both P<0.001). (3)By constructing protein-protein interaction network, four candidate immune related genes were screened out: neuropeptide Y (NPY), somatostatin (SST), cholecystokinin (CCK) and tachykinin 1 (TAC1). The results showed that the mRNA expression levels of NPY, SST and CCK in the hippocampus of the three groups were significantly different ( F=11.41, 10.43, 5.85, all P<0.05), but there was no statistical difference in the TAC1 mRNA expression level ( F=0.08, P>0.05). The mRNA levels of NPY, SST and CCK in the hippocampus of rats in the MK-801 high-dose group were lower than those in the normal saline group (all P<0.05). Conclusion:Both medium dose and high dose MK-801 administration can reduce the volume of hippocampal gray matter in schizophrenia model rats, but they have different effects on the expression of hippocampal immune related genes, of which high dose administration has a greater effect.
9.Correlation between handgrip strength and pulmonary function in college students
LUO Yu, MA Tian, QUE Gang, REN Zhe, GUO Junxia, WU Hao
Chinese Journal of School Health 2023;44(8):1226-1229
Objective:
To explore the relationship between handgrip strength (HGS) and pulmonary function (PF) in college students with sedentary lifestyle, so as to provide a reference for taking HGS as an essential factor of PF.
Methods:
In March 1-5, 2023, a total of 44 college students were recruited and were divided into the sedentary group (22) and exercise group (22) according to the International Physical Activity Questionaire (IPAQ), with 22 students in each group. Independent sample t-test was used to compare the indexes between groups, pearson correlation coefficient was used to determine the correlation between HGS and PF. Multiple linear regression analysis was used to determine the predictive model of PF.
Results:
There were statistical significance of the correlations between HGS and FVC, MEP, PEF, FEV1, FIVC, MIP, and PIF ( r=0.79, 0.47, 0.44, 0.60, 0.72, 0.53 , 0.49, P <0.01). When gender, physical activity, age, height, weight, and HGS were included as predictors in the regression model, height and HGS had significant effects on FVC ( R 2=0.75, F= 60.55 , P <0.01), weight and HGS had a good predictive effect on FIVC ( R 2=0.67, F=41.77, P <0.01).
Conclusion
HGS is significantly associated with PF in college students with sedentary lifestyle. Therefore, HGS can be used as an important indicator to predict the PF status of habitual sedentary college students.
10.Melatonin Attenuates Mitochondrial Damage in Aristolochic AcidInduced Acute Kidney Injury
Jian SUN ; Jinjin PAN ; Qinlong LIU ; Jizhong CHENG ; Qing TANG ; Yuke JI ; Ke CHENG ; Rui WANG ; Liang LIU ; Dingyou WANG ; Na WU ; Xu ZHENG ; Junxia LI ; Xueyan ZHANG ; Zhilong ZHU ; Yanchun DING ; Feng ZHENG ; Jia LI ; Ying ZHANG ; Yuhui YUAN
Biomolecules & Therapeutics 2023;31(1):97-107
Aristolochic acid (AA), extracted from Aristolochiaceae plants, plays an essential role in traditional herbal medicines and is used for different diseases. However, AA has been found to be nephrotoxic and is known to cause aristolochic acid nephropathy (AAN).AA-induced acute kidney injury (AKI) is a syndrome in AAN with a high morbidity that manifests mitochondrial damage as a key part of its pathological progression. Melatonin primarily serves as a mitochondria-targeted antioxidant. However, its mitochondrial protective role in AA-induced AKI is barely reported. In this study, mice were administrated 2.5 mg/kg AA to induce AKI. Melatonin reduced the increase in Upro and Scr and attenuated the necrosis and atrophy of renal proximal tubules in mice exposed to AA. Melatonin suppressed ROS generation, MDA levels and iNOS expression and increased SOD activities in vivo and in vitro. Intriguingly, the in vivo study revealed that melatonin decreased mitochondrial fragmentation in renal proximal tubular cells and increased ATP levels in kidney tissues in response to AA. In vitro, melatonin restored the mitochondrial membrane potential (MMP) in NRK-52E and HK-2 cells and led to an elevation in ATP levels. Confocal immunofluorescence data showed that puncta containing Mito-tracker and GFP-LC3A/B were reduced, thereby impeding the mitophagy of tubular epithelial cells. Furthermore, melatonin decreased LC3A/B-II expression and increased p62 expression. The apoptosis of tubular epithelial cells induced by AA was decreased. Therefore, our findings revealed that melatonin could prevent AA-induced AKI by attenuating mitochondrial damage, which may provide a potential therapeutic method for renal AA toxicity.


Result Analysis
Print
Save
E-mail