1.Treatment of Diabetic Retinopathy with Blood Stasis, Collateral Obstruction, and Qi and Yin Deficiency Syndrome with Tongluo Mingmu Capsules: A Randomized, Double-blind, and Multi-center Phase Ⅲ Clinical Trial
Junxia REN ; Yongzheng WANG ; Xiaofei LIU ; Li SUN ; Libo YANG ; Lie WU ; Fengmei LIAN ; Qiping WEI ; Lijuan WEI ; Jingsheng YU ; Jianke HAN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):170-178
ObjectiveTo evaluate the clinical efficacy and safety of Tongluo Mingmu capsules in the treatment of diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome. MethodA randomized, double-blind, positive-control, and multi-center clinical trial design method was used. 416 patients with diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome in four test centers were included (the ratio of the treatment group to the control group was 3∶1). On the basis of standardized hypoglycemic treatment, the treatment group was given both four Tongluo Mingmu capsules and two Calcium Dobesilate capsule agents three times a day, while the control group were given both two Calcium Dobesilate capsules and four Tongluo Mingmu capsule agents three times a day. The course of treatment was 12 weeks. The curative effect of Tongluo Mingmu capsules was evaluated by comparing the comprehensive curative effect of diabetic retinopathy, traditional Chinese medicine(TCM) syndrome score, corrected visual acuity, fundus changes, fundus fluorescence angiography, and other curative effect indexes before and after treatment in the two groups. At the same time, general examination, laboratory examination, and adverse events were performed to evaluate the safety of the drug. ResultThe baseline demographic data and disease characteristics of the treatment group and the control group were balanced and comparable, with the difference not statistically significant. After 12 weeks of treatment, the total effective rate of the comprehensive curative effect of diabetic retinopathy in the treatment group (61.0%, 189/310) was better than that in the control group (44.1%, 45/102), and the difference was statistically significant (χ2=8.880, P<0.01). The total effective rate of TCM syndromes in the treatment group (88.4%, 259/293) was better than that in the control group (69.9%, 65/93), and the difference was statistically significant (χ2=17.927, P<0.01). The disappearance rate of dry eyes (χ2=8.305), dull complexion (χ2=4.053), lassitude (χ2=10.267), shortness of breath (χ2=8.494), and dry stool (χ2=8.657) in the treatment group was higher than that in the control group, and the difference between the groups was statistically significant (P<0.05, P<0.01). In terms of improving corrected visual acuity (χ2=8.382), fundus changes (χ2=6.026) , the treatment group was significantly better than the control group (P<0.05). During the trial, the incidence of adverse events in the treatment group and the control group was 1.3% and 2.9%, respectively. There was no significant difference between the two groups. In addition, there were no serious adverse events and adverse events leading to withdrawal in both groups. ConclusionTongluo Mingmu capsules can improve the comprehensive curative effect of diabetic retinopathy and enhance the efficacy of TCM syndromes, visual acuity, fundus changes, and fundus fluorescein angiography, with great safety. Therefore, it can provide a new alternative therapeutic drug for patients with diabetic retinopathy.
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Application of the blastomere count variations “skip value” in the embryo AI assessment
Jingwei YANG ; Wei HAN ; Weiwei LIU ; Junxia LIU ; Guoning HUANG ; Xiaodong ZHANG
Chinese Journal of Obstetrics and Gynecology 2024;59(7):548-558
Objective:To explore the correlation between blastomere count variations “skip value” which extracted from by time-lapse technology (TLT) combined with artificial intelligence (AI) and morphological features of in vitro fertilization (IVF) embryo, and to test its feasibility in clinical applications.Methods:This study was a diagnostic experiment (AI reassessment of embryo transferred patients), a total of 6 545 embryos from 1 226 patients who underwent IVF at the Women and Children′s Hospital of Chongqing Medical University from December 2020 to December 2021 were retrospectively analyzed, of which 2 869 embryos were attempted to cultured to blastocyst stage by TLT. The embryo dynamic map (EDM) was drawn by Embryo Viewer, a TLT recording software, based on embryo developmental kinetics. The self-developed AI embryo evaluation software identified and recorded the number of cleavages in real time during embryonic development, and compared with the EDM, the correlation between the skip value formed by the change of cleavage sphere counts and the outcomes of the embryos was analyzed. The correlation among skip value, morphological score of embryo, implantation rate and live birth rate were performed by Spearman and step-up logistic regression. The receiver operating characteristic (ROC) curve was selected for reporting there relationship of skip value and morphology. Finally, predicting power of skip value for implantation and live birth rate were performed by ROC analysis.Results:The total skip values extracted from the blastomere count of embryos (72 hours post-fertilization) were negatively correlated with abnormal cleavage, blastocyst formation rate, day 3 (D3)-cell score, uneven size and fragmentation (the β values were -0.268, -0.116, -0.213, -0.159 and -0.222, respectively; all P<0.001); positively correlated with D3-cell number ( β=0.034; P<0.001); negatively correlated with blastocyst formation rate and implantation rate ( OR=0.97, 95% CI: 0.93-0.99, P=0.034; OR=0.96, 95% CI: 0.93-0.98, P=0.044). The power of predicting implantation were similar between the order selection of skip values and traditional morphology criteria [area under curve (AUC): 0.679 vs 0.620]. Live birth rate were negatively correlated with female age ( OR=0.91, 95% CI: 0.88-0.93; P<0.001), D3 general score ( OR=0.77, 95% CI: 0.59-0.99; P=0.045) and order selection of skip values ( OR=0.98, 95% CI: 0.96-0.99; P=0.038), while positively correlated with retrieved oocyte number and endometrial thickness in embryo transferred ( OR=1.08, 95% CI:1.05-1.11, P<0.001; OR=1.09, 95% CI:1.06-0.12, P<0.001, respectively) from multivariate regression analysis, and the power of predicting live birth was 0.666 for AUC. Conclusions:The skip value and its order form is a systematic quantification of embryo development, correlated with embryo developmental quality and clinical outcome. It could be an addition parameter for embryo culture and selection.
6.A Phase Ⅲ Clinical Observation of Yishen Yangxin Anshen Tablets in Treatment of Insomnia with Deficiency of Heart Blood and Insufficiency of Kidney Essence
Wei WANG ; Junxia REN ; Yongzheng WANG ; Jianke HAN ; Limin YANG ; Weidong WANG ; Fengmei LIAN ; Changshan AI ; Xiaoli YIN ; Baoliang WANG ; Yi MENG ; Shuguang YUAN ; Desheng ZHOU ; Xuedong GAO
Chinese Journal of Experimental Traditional Medical Formulae 2023;29(4):110-116
ObjectiveTo confirm the clinical efficacy and safety of Yishen Yangxin Anshen tablets in the treatment of insomnia (heart-blood deficiency and kidney-essence insufficiency syndrome). MethodA randomized block, double-blind, placebo-controlled, multi-center clinical trial design method was adopted, and a total of 480 patients with insomnia due to deficiency of heart blood and insufficiency of kidney essence (treatment group-control group 3∶1) from seven hospitals (Guang'anmen Hospital, China Academy of Chinese Medical Sciences, The First Clinical Hospital, Jilin Province Academy of Traditional Chinese Medicine(TCM), The Second Affiliated Hospital of Liaoning University of TCM, The First Affiliated Hospital of Henan University of Chinese Medicine, Henan Province Hospital of TCM, Hebei General Hospital, The First Hospital of Hunan University of Chinese Medicine) were enrolled. The treatment group was given Yishen Yangxin Anshen tablets and the control group received placebo tablets (4 tablets/time, 3 times/day, 4 weeks of administration, 4 weeks of follow-up after drug withdrawal). The sleep dysfunction rating scale (SDRS) score, pittsburgh sleep quality index (PSQI) score, TCM, polysomnography (PSG) indicators from four hospital (Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Henan Province Hospital of TCM, Hebei General Hospital, The First Hospital of Hunan University of Chinese Medicine), and other efficacy indicators were compared between the two groups before and after treatment. Through general physical examination, laboratory examination, and observation of adverse events, the safety of the drugs was evaluated. ResultThe baseline indexes of the two groups showed no significant difference and thus the two groups were comparable. After treatment, the total score of SDRS in the treatment group was lower than that in the control group (P<0.01). After drug withdrawal for 4 weeks, the total score of SDRS demonstrated no significant change in the treatment group as compared with that at the end of treatment, indicating that the rebound change of curative effect was not obvious. After treatment, the total score of PSQI in the treatment group decreased as compared with that in the control group (P<0.01), and the change of total score of PSQI in the treatment group was statistically significant (P<0.05) after drug withdrawal for 4 weeks but small, indicating that the rebound change of curative effect was not obvious. After treatment, the total effective rate about the TCM symptoms in the treatment group was higher than that in the control group (χ2=137.521,P<0.01). After treatment, the disappearance rates of single indexes in the treatment group, such as difficulty in falling asleep, easily waking up after sleeping, early awakening, short sleep time, dreamfulness, palpitation, forgetfulness, dizziness, mental fatigue, and weakness of waist and knee, increased compared with those in the control group (P<0.01). After treatment, the treatment group demonstrated fewer awaking times (AT), longer total sleep time (TST), lower ATA/TST ratio, and higher sleep efficiency (%) than the control group (P<0.05). No abnormal value or aggravation related to drugs was observed in either group. The incidence of adverse events in the treatment group and the control group was 5.57% and 8.40% respectively. No serious adverse events or adverse events leading to withdrawal happened in either group. ConclusionYishen Yangxin Anshen tablets is effective and safe for patients with insomnia of deficiency of heart-blood and insufficiency of kidney-essence.
7.IgD multiple myeloma: report of 1 case and review of literature
Han XU ; Shumin NIE ; Junxia HUANG ; Tianlan LI ; Yan GAO ; Chunxia MAO ; Shanshan LIU ; Yujie XU ; Jingjing ZHOU ; Jingjing XIAO ; Mengying WANG ; Fanjun MENG ; Xianqi FENG
Journal of Leukemia & Lymphoma 2022;31(2):107-110
Objective:To investigate the clinical features of IgD multiple myeloma (MM) and the effect and prognosis of daratumumab-based combination therapy.Methods:The clinicopathological data of a IgD MM patient with disease progression and extramedullary infiltration treated with daratumumab in the Affiliated Hospital of Qingdao University in December 2019 were retrospectively analyzed.Results:The 74-year-old woman was diagnosed as IgD MM by bone marrow aspiration and immunofixation electrophoresis. The patient was given VD (bortezomib, dexamethasone), RD (lenalidomide, dexamethasone) and ID (ixazomib, dexamethasone) regimens. In June 2020, the patient developed multiple subcutaneous nodules, and she was assessed as progressive disease with extensive extramedullary infiltration. After treated with daratumumab-PAD (liposomal doxorubicin, bortezomib, dexamethasone) regimen, the patient's subcutaneous nodules were significantly reduced and partially disappeared, and the general condition was significantly improved. But the patient was in a cachexia state and finally died of the irregular treatment and disease progression.Conclusions:IgD MM has a low incidence and a short survival period, and there is no uniform standard treatment. The early application of daratumumab combined with proteasome inhibitors, immunomodulators, cytotoxic drugs and hematopoietic stem cell transplantation may improve the overall survival of patients.
8.Feature exaction and classification of autism spectrum disorder children related electroencephalographic signals based on entropy.
Jie ZHAO ; Meng DING ; Zhen TONG ; Junxia HAN ; Xiaoli LI ; Jiannan KANG
Journal of Biomedical Engineering 2019;36(2):183-188
The early diagnosis of children with autism spectrum disorders (ASD) is essential. Electroencephalography (EEG) is one of most commonly used neuroimaging techniques as the most accessible and informative method. In this study, approximate entropy (ApEn), sample entropy (SaEn), permutation entropy (PeEn) and wavelet entropy (WaEn) were extracted from EEGs of ASD child and a control group, and Student's -test was used to analyze between-group differences. Support vector machine (SVM) algorithm was utilized to build classification models for each entropy measure derived from different regions. Permutation test was applied in search for optimize subset of features, with which the SVM model achieved best performance. The results showed that the complexity of EEGs in children with autism was lower than that of the normal control group. Among all four entropies, WaEn got a better classification performance than others. Classification results vary in different regions, and the frontal lobe showed the best performance. After feature selection, six features were filtered out and the accuracy rate was increased to 84.55%, which can be convincing for assisting early diagnosis of autism.
Algorithms
;
Autism Spectrum Disorder
;
classification
;
diagnosis
;
Child
;
Electroencephalography
;
Entropy
;
Humans
;
Support Vector Machine
9.Association between coronary heart disease and methylenetetrahydrofolate reductase polymorphism
Jihua LIANG ; Xinxin ZHANG ; Shouyi TANG ; Junxia HAN ; Hui JIAO ; Wenguo WANG
Chinese Journal of Primary Medicine and Pharmacy 2018;25(12):1557-1560
Objective To explore the correlation between the pathogenesis of coronary heart disease and the polymorphism of methylenetetrahydrofolate reductase ( MTHFR ) .Methods 130 cases of coronary heart disease diagnosed and treated in Heze Municiple Hospital from July 2015 to July 2017 were selected as observation group .At the same time,130 healthy people were selected as control group .The serum folate and homocysteine ( HCY) levels were compared between the two groups .At the same time, polymerase chain reaction -restriction fragment length polymorphism was used to analyze the MTHFR gene polymorphisms .The distribution of MTHFR gene polymorphism was compared between the two groups .Results The level of serum folic acid in the observation group was (5.76 ± 2.14)g/L,which was significantly lower than (7.34 ±2.43)g/L in the control group (t=5.64,P<0.05).The level of serum HCY in the observation group was (15.46 ±5.74)μmol/L,which was significantly higher than (10.28 ± 4.38)μmol/L in the control group (t=6.43,P<0.05).The frequencies of TT type,TC type and CC type of MTHFR gene in the observation group were 36.92%,46.92%and 16.15%,respectively.The frequencies of TT type,TC type and CC type of MTHFR gene in the control group were 21.54%,55.38% and 23.08%,respectively.The frequency of TT type in the observation group was significantly higher than that of the control group (χ2 =8.25,P<0.05). There were no statistically significant differences in folic acid levels among different gene types in the observationgroup(t=1.31,0.55,0.73,all P>0.05),but the serum HCY level of TT type was significantly higher than that of CT type and CC type in the observation group (t=5.33,4.62,all P<0.05).Conclusion Serum folic acid level, HCY level and homozygous mutations of MTHFR gene type have certain relationship with the occurrence of coronary heart disease ,the body serum folic acid level and the distribution of MTHFR genotypes can affect the concentration of HCY,thus affecting the occurrence of coronary heart disease .
10.Brain 1H-MRS study on the effects of copper chelation therapy on WD patients
Shumei WU ; Wenbin HU ; Yongzhu HAN ; Jiyuan HU ; Xun WANG ; Kai LI ; Gongqiang WANG ; Junxia WU ; Zengfeng SU ; Renmin YANG
Chinese Journal of Nervous and Mental Diseases 2015;(10):601-606
Objective To examine the brain metabolic changes in WD patients receiving copper chelation by us?ing 1H-MRS. Method Thirty-nine patients with WD was randomly divided into four groups: non-brain type group (18 cases), brain type prior-treatment group and short-term treatment group (21 cases), long-term treatment group (20 cases) from short-term treatment group, and 20 healthy volunteers served as a control group. 1H-MRS and MRI were performed on patients on 1.5/MR/MRS system to detect these above-mentioned items before and after treatment. Result The mean of NAA/Cr was significantly lower in the left putamen and head of the caudate nucleus than in the left basal ganglion in the 39 patients with WD. The mean of NAA/Cr and Cho/Cr in the left putamen and basal ganglion was significantly lower in non-brain type group than in control group(P<0.01). The mean of NAA/Cr Cho/Cr and NAA/Cho in the left putamen,head of the caudate nucleus and basal ganglion were significantly lower in brain type group than in control group(P<0.01 or P<0.05). The mean of NAA/Cr in the left putamen was much lower in brain type group than in non-brain type group (P<0.01). The mean of NAA/Cr, Cho/Cr and NAA/Cho of short-term treatment group in the left putamen, head of the caudate nucleus and basal ganglion was not significantly different between brain type group and short-term treatment group(P>0.05). The mean of NAA/Cr and NAA/Cho in the left putamen and basal ganglion was much higher in long-term treatment group than in brain type group(P<0.01 or P<0.05). The mean of Cho/Cr in the left head of caudate nucleus were much higher after treatment compared with prior-treatment group(P<0.05). The mean of NAA/Cr in the left putamen, head of the left caudate nucleus and basal ganglion in all groups was negatively correlated with course of the disease. Conclusion There are significant differences in brain metabolism among different type of WD. The long-term but not short-term copper chelation significantly improves brain metabolism. NAA/Cr may be used as a non-invasive indicator to examine the efficacy of treatment.

Result Analysis
Print
Save
E-mail