1.Related factors of post-stroke depression in patients with cerebral infarction during hospitalization in rehabilitation department
Fang LI ; Huizhen LIU ; Liping MEI ; Tong ZHANG ; Haojie ZHANG ; Bingjie LI ; Jun ZHAO
Chinese Journal of Rehabilitation Theory and Practice 2024;30(2):217-222
ObjectTo explore the risk factors related to the intensity of post-stroke depression in patients with cerebral infarction during hospitalization in the rehabilitation department. MethodsThe hospital consultation records of cerebral infarction patients in Beijing Bo'ai Hospital from December, 2019 to February, 2023 were reviewed from the hospital information system, and those who were diagnosed as depression visited the department of psychology were selected. It was collected including general information of sexes, ages, education levels, matrimony; medical features of course, location, affected side, sensory disorders, aphasia, agrypnia, dysphagia, hand-shoulder syndrome, constipation; functioning of muscle strength and Brunnstrom stages; and scores of Mini-Mental State Examination (MMSE), National Institutes of Health Stroke Scale (NIHSS), Fugl-Meyer Assessment (FMA), Fugl-Meyer Assessment-Balance (FMA-B), modified Barthel Index (MBI) and Hamilton Depression Scale (HAMD). Patients with HAMD scores ≤ 20 were as the low group, and those > 20 were as the high group. ResultA total of 2 403 hospitalized stroke patients were included, out of which 269 patients with cerebral infarction were diagnosed as depression and visited the department of psychology; while 103 cases were in the low group and 166 cases were in the high group. The incidence of constipation was less, and the incidence of dysphagia and shoulder-hand syndrome was higher in the high group (χ2 > 5.379, P < 0.05), with weaker strength of iliopsoas muscle and quadriceps muscle, earlier of Brunnstrom stage of lower extremities and hands, and worse scores of NIHSS, MMSE, FMA, FMA-B and MBI (|Z| > 2.020, t > 2.171, P < 0.05). Logistic regression showed that constipation (OR = 0.435), quadriceps muscle strength (OR = 0.782) and dysphagia (OR = 2.602) related to the intensity of post-stroke depression in convalescent patients (P < 0.05). ConclusionPost-stroke dysphagia and poor quadriceps muscle strength may exacerbate post-stroke depression; however, constipation may not.
2.Research status of anti-inflammatory effect of traditional Chinese medicine based on NLRP3 inflammatory body
Fu-Mei XU ; Jun-Yuan ZENG ; Lei ZHAO ; Qi-Li ZHANG ; Peng-Fei XIA ; Yin-Qiang JIA ; Jie WANG ; Peng-Xia FANG ; Yan-Li XU
The Chinese Journal of Clinical Pharmacology 2024;40(6):923-927
Inflammasome is a kind of intracellular polyprotein complex,which is an important component of the complex system of local inflammatory microenvironment after human tissue damage.When the inflammasome is activated,it induces the activation of cysteine aspartate proteinase 1(caspase-1),mediates the maturation and secretion of proinflammatory cytokines,such as interleukin(IL)-1 β and IL-18,and induces cell death,which plays an important role in regulating the host immune response to pathogen infection and tissue repair of cell damage.Nod-like receptor protein 3(NLRP3)inflammatory body,which is composed of NLRP3,pro-cysteine aspartic acid specific protease-1(pro-caspase-1)and apoptosis-related spot-like protein(ASC),is the most deeply and widely studied type of inflammatory body,which plays an important role in the regulation of inflammation.When NLRP3 inflammatory bodies are activated,inflammatory mediators are produced and released,which participate in the occurrence and development of a variety of inflammatory diseases.Some studies have shown that traditional Chinese medicine can improve the pathological state of a variety of diseases by inhibiting NLRP3 inflammatory bodies,and play a role in the prevention and treatment of a variety of inflammatory diseases,including cardiovascular diseases,joint inflammation,diabetes and so on.This paper systematically combs the mechanism of NLRP3 inflammatory bodies,and summarizes the latest research reports on the effects of traditional Chinese medicine compound prescription,traditional Chinese medicine monomers and traditional Chinese medicine extracts on NLRP3 inflammatory bodies in the treatment of inflammatory diseases,in order to provide new ideas for the further study of the pathogenesis and drug treatment of many inflammatory diseases.
3.Research progress and primary analysiss for the design of codrug
Jing ZHAO ; Xia CHEN ; Jun-Mei WANG
The Chinese Journal of Clinical Pharmacology 2024;40(8):1226-1230
Codrug is a kind of prodrug compound formed by covalent combination of two or more pharmacologically active drug molecules,which is activated in vivo to release the original drug to play a therapeutic effect.This kind of drug design has the characteristics of synergistic efficacy,reducing incidence of adverse drug reactions,improving stability and pharmacokinetic characteristics,targeted release,etc.,but with the development of pharmaceutical technology,these characteristics are gradually replaced by other designs.This article will introduce the characteristics and application of co-drugs,and analyze the advantages,disadvantages and prospects of such drugs in drug development strategy.
4.Simultaneous GC-MS determination of sixteen pesticide residues and safety assessment for Lycii Fructus
Jia-Qi QIN ; Qiang-Qiang QI ; Ya-Jun ZHANG ; Yan WANG ; Si-Yuan ZHAO ; De-Yan CAO ; Mei-Lin ZHU
Chinese Traditional Patent Medicine 2024;46(1):143-149
AIM To establish a GC-MS method for the simultaneous content determination of sixteen pesticide residues in Lycii Fructus and perform safety assessment.METHODS The analysis was performed on DB-5MS chromatographic column(30 m×0.25 mm,0.25 μm)subjected to the programmed heating,with splitless injection of 1.0 μL dissolved sample at a flowing rate of 1.0 mL/min.Other parameters were as follows:injection port temperature of 250℃,electron impact ionization(EI),electron energy of 70 eV;ion source temperature of 230℃,multi-reaction monitoring mode,and collision gas.of high-purity N2.Pesticide residues with relatively high dietary risk were analyzed and discussed with regard to residue levels,dietary intake risk,risk ranking and cumulative exposure assessment.RESULTS Sixteen pesticides showed good linear relationships within their own ranges(r≥0.994 4),whose average recoveries were 70%-114%,with the RSDs of less than 2%.The highest average cyfluthrin residue of 0.999 2 mg/kg in Lycii Fructus of production regions and the highest average cypermethrin residue of 0.088 4 mg/kg in Lycii Fructus commodities were both detected.In Lycii Fructus of production regions with chronic hazard index(HI)value of 0.012 9 and acute HI value of 0.065 5 and their commodities with chronic HI of 0.001 2 and acute HI of 0.005 4,the pesticide residue of cypermethrin was the leading cause of chronic and acute dietary risk,and additionally,pyridaben within maximum residue limit(MRL)was the only detectectable highly toxic pesticide among the other most concerning pestcides of deltamethrin,pyridaben,chlorpyrifos,dichlorvos and methidathion.CONCLUSION There exist pesticide residues within MRL values in some samples of Lycii Fructus and the use of cypermethrin should be well-controlled.
5.Clinical phenotype and gene variation analysis of MED25 gene mutation induced Basel-Vanagaite-Smirin-Yosef syndrome
Guangjin LUO ; Xuan ZHANG ; Xiao CHEN ; Lihua WANG ; Jing ZHAO ; Xiao DING ; Jun CHEN ; Lijiang WANG ; Aiyun YUAN ; Mei HOU
Chinese Journal of Neurology 2024;57(1):47-53
Objective:To investigate the clinical phenotype and genetic variation of Basel-Vanagaite-Smirin-Yosef syndrome (BVSYS), and to enhance clinicians′ knowledge of the disease.Methods:The clinical data of a child with BVSYS admitted to the Department of Neurological Rehabilitation, Qingdao Women and Children′s Hospital Affiliated to Qingdao University in February 2023 were collected. Whole genome sequencing was used to analyze the pathogenic genes of the child, and Sanger sequencing was used to verify the suspected mutation sites of the family members. The clinical phenotype and genetic variation characteristics were analyzed, and the clinical characteristics of BVSYS were summarized in combination with relevant literature.Results:The patient, a female aged 3 years and 1 month, presented with global developmental delay, speech disorder, distinctive facial features, esotropia, epilepsy, hypotonia and atrial septal defect. Brain magnetic resonance imaging revealed bilateral ventriculomegaly with abnormal signal intensity in the posterior bodies of both lateral ventricles and thinning of the corpus callosum. The whole genome sequencing revealed a homozygous missense mutation c.518 (exon5) T>C (p.IIe173Thr) in the MED25 gene of the child, and Sanger sequencing confirmed that her parents and elder brother carried the aforementioned heterozygous mutation, which was classified as a likely pathogenic mutation according to the guidelines of the American College of Medical Genetics and Genomics. A total of 22 cases from 6 literature sources were retrieved, with no reported cases in China so far. Conclusions:BVSYS is clinically rare. For patients presenting with unexplained global developmental delay or intellectual disability combined with craniofacial, neurological, cardiac, and eye abnormalities, targeted genetic testing can facilitate a definite diagnosis.
6.Development of the robotic digestive endoscope system and an experimental study on mechanistic model and living animals (with video)
Bingrong LIU ; Yili FU ; Kaipeng LIU ; Deliang LI ; Bo PAN ; Dan LIU ; Hao QIU ; Xiaocan JIA ; Jianping CHEN ; Jiyu ZHANG ; Mei WANG ; Fengdong LI ; Xiaopeng ZHANG ; Zongling KAN ; Jinghao LI ; Yuan GAO ; Min SU ; Quanqin XIE ; Jun YANG ; Yu LIU ; Lixia ZHAO
Chinese Journal of Digestive Endoscopy 2024;41(1):35-42
Objective:To develop a robotic digestive endoscope system (RDES) and to evaluate its feasibility, safety and control performance by experiments.Methods:The RDES was designed based on the master-slave control system, which consisted of 3 parts: the integrated endoscope, including a knob and button robotic control system integrated with a gastroscope; the robotic mechanical arm system, including the base and arm, as well as the endoscopic advance-retreat control device (force-feedback function was designed) and the endoscopic axial rotation control device; the control console, including a master manipulator and an image monitor. The operator sit far away from the endoscope and controlled the master manipulator to bend the end of the endoscope and to control advance, retract and rotation of the endoscope. The air supply, water supply, suction, figure fixing and motion scaling switching was realized by pressing buttons on the master manipulator. In the endoscopy experiments performed on live pigs, 5 physicians each were in the beginner and advanced groups. Each operator operated RDES and traditional endoscope (2 weeks interval) to perform porcine gastroscopy 6 times, comparing the examination time. In the experiment of endoscopic circle drawing on the inner wall of the simulated stomach model, each operator in the two groups operated RDES 1∶1 motion scaling, 5∶1 motion scaling and ordinary endoscope to complete endoscopic circle drawing 6 times, comparing the completion time, accuracy (i.e. trajectory deviation) and workload.Results:RDES was operated normally with good force feedback function. All porcine in vivo gastroscopies were successful, without mucosal injury, bleeding or perforation. In beginner and advanced groups, the examination time of both RDES and ordinary endoscopy tended to decrease as the number of operations increased, but the decrease in time was greater for operating RDES than for operating ordinary endoscope (beginner group P=0.033; advanced group P=0.023). In the beginner group, the operators operating RDES with 1∶1 motion scaling or 5∶1 motion scaling to complete endoscopic circle drawing had shorter completion time [1.68 (1.40, 2.17) min, 1.73 (1.47, 2.37) min VS 4.13 (2.27, 5.16) min, H=32.506, P<0.001], better trajectory deviation (0.50±0.11 mm, 0.46±0.11 mm VS 0.82±0.26 mm, F=38.999, P<0.001], and less workload [42.00 (30.00, 50.33) points, 43.33 (35.33, 54.00) points VS 52.67 (48.67, 63.33) points, H=20.056, P<0.001] than operating ordinary endoscope. In the advanced group, the operators operating RDES with 1∶1 or 5∶1 motion scaling to complete endoscopic circle drawing had longer completion time than operating ordinary endoscope [1.72 (1.37, 2.53) min, 1.57 (1.25, 2.58) min VS 1.15 (0.86, 1.58) min, H=13.233, P=0.001], but trajectory deviation [0.47 (0.13, 0.57) mm, 0.44 (0.39, 0.58) mm VS 0.52 (0.42, 0.59) mm, H=3.202, P=0.202] and workload (44.62±21.77 points, 41.24±12.57 points VS 44.71±17.92 points, F=0.369, P=0.693) were not different from those of the ordinary endoscope. Conclusion:The RDES enables remote control, greatly reducing the endoscopists' workload. Additionally, it gives full play to the cooperative motion function of the large and small endoscopic knobs, making the control more flexible. Finally, it increases motion scaling switching function to make the control of endoscope more flexible and more accurate. It is also easy for beginners to learn and master, and can shorten the training period. So it can provide the possibility of remote endoscopic control and fully automated robotic endoscope.
7.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
8.Pharmacokinetics of wogonin-aloperine cocrystal in rats
Zhong-shui XIE ; Chun-xue JIA ; Yu-lu LIANG ; Xiao-jun ZHAO ; Bin-ran LI ; Jing-zhong HAN ; Hong-juan WANG ; Jian-mei HUANG
Acta Pharmaceutica Sinica 2024;59(9):2606-2611
Pharmaceutical cocrystals is an advanced technology to improve the physicochemical and biological properties of drugs. However, there are few studies on the
9.Design of automatic urine volume detection and collection device
Yan CHEN ; De-Zhao ZHAI ; Xiao-Quan ZHANG ; Fu-Long LIU ; Xiao-Tao ZHANG ; Yong-Mei ZHANG ; Wei CEHN ; Fang ZHANG ; Guo-Hui WU ; Jun DENG ; Dan LI
Chinese Medical Equipment Journal 2024;45(4):66-69
Objective To develop an automatic urine volume detection and collection device to solve the problems of routine urine test.Methods An automatic urine volume detection and collection device was developed with the components of a main control system,a detection system,a prompting system and a grasping and moving system.The main control system consisted of two STM32 microcontrollers and a reset switch;the detection system was made up of a weighing module,an infrared module and indicator lights,which had its urine volume automatic detection algorithm developed based on the Keil5 platform;the prompting system realized voice broadcasting through the voice module fixed on the back panel of the box;the grasping and moving system was composed of a rail drive motor(86CM stepper motor),a photoelectric switch and a motorized gripper.Results The device developed tested urine samples with an accuracy of 99.44%,and could collect qualified samples automatically and quickly.Conclusion The device developed detects urine volume and collects samples automatically,and enhances the accuracy and efficiency of urine examination.[Chinese Medical Equipment Journal,2024,45(4):66-69]
10.On-site rapid detection of multiple pesticide residues in tea leaves by lateral flow immunoassay
Gao JUNXIA ; Zhang TIANYI ; Fang YIHUA ; Zhao YING ; Yang MEI ; Zhao LI ; Li YE ; Huang JUN ; Zhu GUONIAN ; Guo YIRONG
Journal of Pharmaceutical Analysis 2024;14(2):276-283
The application of pesticides(mostly insecticides and fungicides)during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea.Thus,it is necessary to ascertain whether pesticide residues in tea products exceed the maximum residue limits.However,the complex matrices present in tea samples comprise a major challenge in the analytical detection of pesticide residues.In this study,nine types of lateral flow immunochromatographic strips(LFICSs)were developed to detect the pesticides of interest(fenpropathrin,chlorpyrifos,imidacloprid,thiamethoxam,acet-amiprid,carbendazim,chlorothalonil,pyraclostrobin,and iprodione).To reduce the interference of tea substrates on the assay sensitivity,the pretreatment conditions for tea samples,including the extraction solvent,extraction time,and purification agent,were optimized for the simultaneous detection of these pesticides.The entire testing procedure(including pretreatment and detection)could be completed within 30 min.The detected results of authentic tea samples were confirmed by ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS),which suggest that the LFICS coupled with sample rapid pretreatment can be used for on-site rapid screening of the target pesticide in tea products prior to their market release.

Result Analysis
Print
Save
E-mail