1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
4.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Identification of acute myocardial infarction and stroke events using the National Health Insurance Service database in Korea
Minsung CHO ; Hyeok-Hee LEE ; Jang-Hyun BAEK ; Kyu Sun YUM ; Min KIM ; Jang-Whan BAE ; Seung-Jun LEE ; Byeong-Keuk KIM ; Young Ah KIM ; JiHyun YANG ; Dong Wook KIM ; Young Dae KIM ; Haeyong PAK ; Kyung Won KIM ; Sohee PARK ; Seng Chan YOU ; Hokyou LEE ; Hyeon Chang KIM
Epidemiology and Health 2024;46(1):e2024001-
OBJECTIVES:
The escalating burden of cardiovascular disease (CVD) is a critical public health issue worldwide. CVD, especially acute myocardial infarction (AMI) and stroke, is the leading contributor to morbidity and mortality in Korea. We aimed to develop algorithms for identifying AMI and stroke events from the National Health Insurance Service (NHIS) database and validate these algorithms through medical record review.
METHODS:
We first established a concept and definition of “hospitalization episode,” taking into account the unique features of health claims-based NHIS database. We then developed first and recurrent event identification algorithms, separately for AMI and stroke, to determine whether each hospitalization episode represents a true incident case of AMI or stroke. Finally, we assessed our algorithms’ accuracy by calculating their positive predictive values (PPVs) based on medical records of algorithm- identified events.
RESULTS:
We developed identification algorithms for both AMI and stroke. To validate them, we conducted retrospective review of medical records for 3,140 algorithm-identified events (1,399 AMI and 1,741 stroke events) across 24 hospitals throughout Korea. The overall PPVs for the first and recurrent AMI events were around 92% and 78%, respectively, while those for the first and recurrent stroke events were around 88% and 81%, respectively.
CONCLUSIONS
We successfully developed algorithms for identifying AMI and stroke events. The algorithms demonstrated high accuracy, with PPVs of approximately 90% for first events and 80% for recurrent events. These findings indicate that our algorithms hold promise as an instrumental tool for the consistent and reliable production of national CVD statistics in Korea.
9.Incidence and case fatality of acute myocardial infarction in Korea, 2011-2020
Yeeun SEO ; Jenny MOON ; Hyeok-Hee LEE ; Hyeon Chang KIM ; Fumie KANEKO ; Sojung SHIN ; Eunji KIM ; Jang-Whan BAE ; Byeong-Keuk KIM ; Seung Jun LEE ; Min KIM ; Hokyou LEE
Epidemiology and Health 2024;46(1):e2024002-
OBJECTIVES:
Cardiovascular diseases are a leading cause of mortality worldwide, and acute myocardial infarction (AMI) is particularly fatal condition. We evaluated the incidence and case fatality rates of AMI in Korea from 2011 to 2020.
METHODS:
We utilized data from the National Health Insurance Services to calculate crude, age-standardized, and age-specific incidence rates, along with 30-day and 1-year case fatality rates, of AMI from 2011 to 2020. Age-standardized incidence rates were determined using direct standardization to the 2005 population.
RESULTS:
The crude incidence rate of AMI per 100,000 person-years consistently increased from 44.7 in 2011 to 68.3 in 2019, before decreasing slightly to 66.2 in 2020. The age-standardized incidence rate of AMI displayed a 19% rise from 2011 to 2019, followed by a slight decline in 2020. The increasing trend for AMI incidence was more pronounced in males than in females. Both 30-day and 1-year case fatality rates remained stable among younger individuals but showed a decrease among older individuals. There was a minor surge in case fatality in 2020, particularly among recurrent AMI cases.
CONCLUSIONS
Over the past decade, the AMI incidence rate in Korea has consistently increased, with a slight downturn in 2020. The case fatality rate has remained relatively stable except for a minor increase in 2020. This study provides data for continuous surveillance, the implementation of targeted interventions, and the advancement of research aimed at AMI in Korea.
10.Newly Developed Sex-Specific Z Score Model for Coronary Artery Diameter in a Pediatric Population
Jeong Jin YU ; Hee Joung CHOI ; Hwa Jin CHO ; Sung Hye KIM ; Eun Jung CHEON ; Gi Beom KIM ; Lucy Youngmin EUN ; Se Yong JUNG ; Hyun Ok JUN ; Hyang-Ok WOO ; Sin-Ae PARK ; Soyoung YOON ; Hoon KO ; Ji-Eun BAN ; Jong-Woon CHOI ; Min Seob SONG ; Ji Whan HAN
Journal of Korean Medical Science 2024;39(16):e144-
Background:
This study aimed to generate a Z score calculation model for coronary artery diameter of normal children and adolescents to be adopted as the standard calculation method with consensus in clinical practice.
Methods:
This study was a retrospective, multicenter study that collected data from multiple institutions across South Korea. Data were analyzed to determine the model that best fit the relationship between the diameter of coronary arteries and independent demographic parameters. Linear, power, logarithmic, exponential, and square root polynomial models were tested for best fit.
Results:
Data of 2,030 subjects were collected from 16 institutions. Separate calculation models for each sex were developed because the impact of demographic variables on the diameter of coronary arteries differs according to sex. The final model was the polynomial formula with an exponential relationship between the diameter of coronary arteries and body surface area using the DuBois formula.
Conclusion
A new coronary artery diameter Z score model was developed and is anticipated to be applicable in clinical practice. The new model will help establish a consensus-based Z score model.

Result Analysis
Print
Save