1.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
2.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
3.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
4.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
5.Practice guidelines for managing extrahepatic biliary tract cancers
Hyung Sun KIM ; Mee Joo KANG ; Jingu KANG ; Kyubo KIM ; Bohyun KIM ; Seong-Hun KIM ; Soo Jin KIM ; Yong-Il KIM ; Joo Young KIM ; Jin Sil KIM ; Haeryoung KIM ; Hyo Jung KIM ; Ji Hae NAHM ; Won Suk PARK ; Eunkyu PARK ; Joo Kyung PARK ; Jin Myung PARK ; Byeong Jun SONG ; Yong Chan SHIN ; Keun Soo AHN ; Sang Myung WOO ; Jeong Il YU ; Changhoon YOO ; Kyoungbun LEE ; Dong Ho LEE ; Myung Ah LEE ; Seung Eun LEE ; Ik Jae LEE ; Huisong LEE ; Jung Ho IM ; Kee-Taek JANG ; Hye Young JANG ; Sun-Young JUN ; Hong Jae CHON ; Min Kyu JUNG ; Yong Eun CHUNG ; Jae Uk CHONG ; Eunae CHO ; Eui Kyu CHIE ; Sae Byeol CHOI ; Seo-Yeon CHOI ; Seong Ji CHOI ; Joon Young CHOI ; Hye-Jeong CHOI ; Seung-Mo HONG ; Ji Hyung HONG ; Tae Ho HONG ; Shin Hye HWANG ; In Gyu HWANG ; Joon Seong PARK
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(2):161-202
Background:
s/Aims: Reported incidence of extrahepatic bile duct cancer is higher in Asians than in Western populations. Korea, in particular, is one of the countries with the highest incidence rates of extrahepatic bile duct cancer in the world. Although research and innovative therapeutic modalities for extrahepatic bile duct cancer are emerging, clinical guidelines are currently unavailable in Korea. The Korean Society of Hepato-Biliary-Pancreatic Surgery in collaboration with related societies (Korean Pancreatic and Biliary Surgery Society, Korean Society of Abdominal Radiology, Korean Society of Medical Oncology, Korean Society of Radiation Oncology, Korean Society of Pathologists, and Korean Society of Nuclear Medicine) decided to establish clinical guideline for extrahepatic bile duct cancer in June 2021.
Methods:
Contents of the guidelines were developed through subgroup meetings for each key question and a preliminary draft was finalized through a Clinical Guidelines Committee workshop.
Results:
In November 2021, the finalized draft was presented for public scrutiny during a formal hearing.
Conclusions
The extrahepatic guideline committee believed that this guideline could be helpful in the treatment of patients.
7.Posterior Approach and Inferior Capsulotomy in Bipolar Hemiarthroplasty for Femoral Neck Fractures: Comparison with Superior Capsulotomy
Young-Seung KO ; Jung-Wee PARK ; Jinwoo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Ki-Choul KIM ; Tae-Young KIM ; Young-Kyun LEE
Clinics in Orthopedic Surgery 2024;16(3):374-381
Background:
Hemiarthroplasty is frequently used to treat displaced femoral neck fractures in elderly patients, but it has a higher risk of postoperative dislocation. We introduced the posterior approach and inferior capsulotomy (PAICO) to enhance joint stability after bipolar hemiarthroplasty for femoral neck fracture. We evaluated whether the PAICO would have a lower dislocation rate than the conventional posterior approach with superior capsulotomy.
Methods:
From January 2021 to December 2021, we prospectively recruited 25 patients (25 hips) aged 50 years or older who underwent bipolar hemiarthroplasty for femoral neck fractures due to low-energy trauma as the PAICO group. We compared the PAICO group with a historical control group who had undergone hemiarthroplasty in 7 institutes between 2010 and 2020. The primary endpoint was dislocation within 1 year after the surgery. We compared data from the PAICO group with the data from the historical control group from the Korean Hip Fracture Registry which was carried out in South Korea.
Results:
A total of 25 patients (25 hips) were enrolled in the present study; 3,477 patients (3,571 hips) who underwent bipolar hemiarthroplasty were reviewed as the historical control group. In the PAICO group, we observed no dislocation, whereas the dislocation rate in the control group was 1.3%.
Conclusions
In patients with displaced femoral neck fractures, the PAICO approach demonstrated comparable results in operation time and complication rates when compared to bipolar hemiarthroplasty using superior capsulotomy. Notably, there were no observed cases of dislocation among patients who underwent the PAICO approach. We recommend this PAICO approach to surgeons using the posterior approach, hoping to prevent dislocation in bipolar hemiarthroplasty.
8.Immune Cells Are DifferentiallyAffected by SARS-CoV-2 Viral Loads in K18-hACE2 Mice
Jung Ah KIM ; Sung-Hee KIM ; Jeong Jin KIM ; Hyuna NOH ; Su-bin LEE ; Haengdueng JEONG ; Jiseon KIM ; Donghun JEON ; Jung Seon SEO ; Dain ON ; Suhyeon YOON ; Sang Gyu LEE ; Youn Woo LEE ; Hui Jeong JANG ; In Ho PARK ; Jooyeon OH ; Sang-Hyuk SEOK ; Yu Jin LEE ; Seung-Min HONG ; Se-Hee AN ; Joon-Yong BAE ; Jung-ah CHOI ; Seo Yeon KIM ; Young Been KIM ; Ji-Yeon HWANG ; Hyo-Jung LEE ; Hong Bin KIM ; Dae Gwin JEONG ; Daesub SONG ; Manki SONG ; Man-Seong PARK ; Kang-Seuk CHOI ; Jun Won PARK ; Jun-Won YUN ; Jeon-Soo SHIN ; Ho-Young LEE ; Ho-Keun KWON ; Jun-Young SEO ; Ki Taek NAM ; Heon Yung GEE ; Je Kyung SEONG
Immune Network 2024;24(2):e7-
Viral load and the duration of viral shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are important determinants of the transmission of coronavirus disease 2019.In this study, we examined the effects of viral doses on the lung and spleen of K18-hACE2 transgenic mice by temporal histological and transcriptional analyses. Approximately, 1×105 plaque-forming units (PFU) of SARS-CoV-2 induced strong host responses in the lungs from 2 days post inoculation (dpi) which did not recover until the mice died, whereas responses to the virus were obvious at 5 days, recovering to the basal state by 14 dpi at 1×102 PFU. Further, flow cytometry showed that number of CD8+ T cells continuously increased in 1×102 PFU-virusinfected lungs from 2 dpi, but not in 1×105 PFU-virus-infected lungs. In spleens, responses to the virus were prominent from 2 dpi, and number of B cells was significantly decreased at 1×105PFU; however, 1×102 PFU of virus induced very weak responses from 2 dpi which recovered by 10 dpi. Although the defense responses returned to normal and the mice survived, lung histology showed evidence of fibrosis, suggesting sequelae of SARS-CoV-2 infection. Our findings indicate that specific effectors of the immune response in the lung and spleen were either increased or depleted in response to doses of SARS-CoV-2. This study demonstrated that the response of local and systemic immune effectors to a viral infection varies with viral dose, which either exacerbates the severity of the infection or accelerates its elimination.
9.Impact of Collateral Circulation on Futile Endovascular Thrombectomy in Acute Anterior Circulation Ischemic Stroke
Yoo Sung JEON ; Hyun Jeong KIM ; Hong Gee ROH ; Taek-Jun LEE ; Jeong Jin PARK ; Sang Bong LEE ; Hyung Jin LEE ; Jin Tae KWAK ; Ji Sung LEE ; Hee Jong KI
Journal of Korean Neurosurgical Society 2024;67(1):31-41
Objective:
: Collateral circulation is associated with the differential treatment effect of endovascular thrombectomy (EVT) in acute ischemic stroke. We aimed to verify the ability of the collateral map to predict futile EVT in patients with acute anterior circulation ischemic stroke.
Methods:
: This secondary analysis of a prospective observational study included data from participants underwent EVT for acute ischemic stroke due to occlusion of the internal carotid artery and/or the middle cerebral artery within 8 hours of symptom onset. Multiple logistic regression analyses were conducted to identify independent predictors of futile recanalization (modified Rankin scale score at 90 days of 4–6 despite of successful reperfusion).
Results:
: In a total of 214 participants, older age (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.56 to 3.67; p<0.001), higher baseline National Institutes of Health Stroke Scale (NIHSS) scores (OR, 1.12; 95% CI, 1.04 to 1.21; p=0.004), very poor collateral perfusion grade (OR, 35.09; 95% CI, 3.50 to 351.33; p=0.002), longer door-to-puncture time (OR, 1.08; 95% CI, 1.02 to 1.14; p=0.009), and failed reperfusion (OR, 3.73; 95% CI, 1.30 to 10.76; p=0.015) were associated with unfavorable functional outcomes. In 184 participants who achieved successful reperfusion, older age (OR, 2.30; 95% CI, 1.44 to 3.67; p<0.001), higher baseline NIHSS scores (OR, 1.12; 95% CI, 1.03 to 1.22; p=0.006), very poor collateral perfusion grade (OR, 4.96; 95% CI, 1.42 to 17.37; p=0.012), and longer door-to-reperfusion time (OR, 1.09; 95% CI, 1.03 to 1.15; p=0.003) were associated with unfavorable functional outcomes.
Conclusion
: The assessment of collateral perfusion status using the collateral map can predict futile EVT, which may help select ineligible patients for EVT, thereby potentially reducing the rate of futile EVT.
10.Analysis of chest compression quality according to the metronome setting rate in metronome-assisted cardiopulmonary resuscitation
Hui Jin CHAE ; Jun Hwi CHO ; Joong Bum MOON ; Myeong Cheol SHIN ; Yoon Soo PARK ; Woong Chan AHN ; Taek Geun OHK
Journal of the Korean Society of Emergency Medicine 2024;35(1):23-30
Objective:
The 2020 Cardiopulmonary Resuscitation (CPR) guidelines recommend the use of feedback devices during CPR training and do not limit their use in actual CPR. Although there have been various studies on metronome-assisted CPR that use a metronome as a feedback device, there are no research results to determine a specific metronome setting rate. We analyzed the quality of CPR and the effectiveness of the metronome feedback according to the metronome setting rate within the recommended chest compression rate range.
Methods:
Fifty healthcare providers who had received CPR training or had performed CPR in the previous 2 years participated, and all of them performed CPR at three rates (100/min, 110/min, and 120/min). The CPR was performed for 2 minutes with only chest compressions. The smartphone metronome (Metronome version 13.0 Android, KHTSXR, Seoul, Korea) application was used for the rate setting, and Resusci Anne QCPR Mk II (Laerdal Medical, Stavanger, Norway) was used to measure the CPR quality. The difference in the CPR quality according to the setting rate was analyzed.
Results:
There was no significant difference in the “average compression depth (mm),” “adequate compression depth ratio (%),” and “adequate release ratio (%)” at the three set rates. The “adequate compression rate ratio (%)” was 98.48±5.27% at 110/min, which was higher than that at 120/min or 100/min, and this was a statistically significant difference (P=0.000). There was no significant difference in the “adequate compression site ratio (%).”
Conclusion
When performing metronome-assisted CPR, setting the rate to 110/min can more appropriately maintain the recommended chest compression rate range and can result in high-quality CPR.

Result Analysis
Print
Save
E-mail