1.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
4.Newly designed flared-end covered versus uncovered self-expandable metallic stents for palliation of malignant colorectal obstruction: a randomized, prospective study
Soo Jung PARK ; Yehyun PARK ; Hyun Jung LEE ; Jae Jun PARK ; Jae Hee CHEON ; Won Ho KIM ; Tae Il KIM
Intestinal Research 2025;23(2):202-212
Background/Aims:
Self-expandable metallic stents (SEMSs) are widely used as palliative or bridge to surgery treatments in patients with malignant colorectal obstruction (MCO). Stent occlusion is more common with uncovered stents, but stent migration is more common with covered stents. Our purpose was to compare the efficacy and safety of a newly designed covered SEMS with an uncovered proximal flared end (CSEMS-UPF) with that of the conventional uncovered SEMS (UCSEMS) in the treatment of MCO.
Methods:
This prospective randomized trial was conducted at a tertiary-care academic hospital. We enrolled 87 patients with stage 4 cancer and MCO: colorectal cancer in 60 patients and extracolonic cancer in 27 patients. Insertion of UCSEMS was randomly assigned to 43 patients, and 44 patients received the CSEMS-UPF. The primary outcome was the duration of stent patency after successful placement. The secondary outcomes were the number of patients with technical and clinical success and early and late complications from the stent insertion.
Results:
The median patency of the stent did not differ between the UCSEMS and CSEMS-UPF groups (484 [231–737] days vs. 216 [66–366] days, P= 0.242). The technical and clinical success rates did not differ significantly between the groups, either (100.0% vs. 93.2%, respectively, P= 0.241; 100.0% vs. 92.7%, respectively, P= 0.112), nor did the early (n = 2 [4.7%] vs. n = 4 [9.8%], P> 0.999) or late (n = 12 [27.9%] vs. n = 15 [36.6%], P> 0.999) stent complication rates differ between the groups.
Conclusions
The UCSEMS and newly developed CSEMS-UPF are similarly effective treatments for MCO, with no differences in the stent migration or occlusion rates (Clinical trial registration number: NCT02640781).
5.Generate Quantitative Computed Tomography-Equivalent Computed Tomography Image Interpretation Reports in Patients with Spinal Deformities
Hyunbin KIM ; Hyeon Su KIM ; Shinjune KIM ; Jun-Il YOO
Journal of Bone Metabolism 2025;32(1):31-37
Background:
Quantitative computed tomography (QCT) is essential for assessing osteoporosis and monitoring spinal deformities. “Clari-QCT,” a software that uses artificial intelligence to analyze conventional computed tomography (CT) scans and produce QCTequivalent reports. This study aims to evaluate the effectiveness of Clari-QCT by comparing its results with traditional QCT, with the goal of validating new diagnostic tools for spinal deformities.
Methods:
The study analyzed dual energy X-ray absorptiometry, CT, and QCT data from 18 patients at Inha University Hospital. Clari-QCT software was evaluated for its ability to generate QCT-equivalent reports from CT images. The software processes abdomen CT images, calculates bone density in designated slices, and provides bone mineral density (BMD), T-score, and Z-score values. Patients were classified into normal, mild, and severe spinal deformity groups. Intraclass correlation coefficient (ICC) analysis was used to measure the agreement between actual and predicted BMD values.
Results:
The study included participants with an average age of 64 and a mean body mass index of 24.88. The average BMD was 94.7 g/cm³ by QCT and 122.5 g/cm³ by Clari- QCT, with individual differences ranging from 4.9 to 61.8. T-score discrepancies ranged from 0.16 to 6.86. ICC analysis showed moderate to high agreement between methods, with ICC1 values of 0.597, ICC2 of 0.64, ICC3 of 0.81, and ICC1k, ICC2k, ICC3k values ranging from 0.748 to 0.895.
Conclusions
Clari-QCT demonstrates good agreement with actual QCT measurements in normal and severe spinal deformity groups but shows reduced accuracy in patients with mild deformities. If the limitations are addressed, it could become a useful tool for monitoring bone health in patients with spinal deformities.
6.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
7.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
8.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
9.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
10.Elevated Circulating Sclerostin Levels in Frail Older Adults: Implications beyond Bone Health
Ji Yeon BAEK ; Seong Hee AHN ; Il-Young JANG ; Hee-Won JUNG ; Eunhye JI ; So Jeong PARK ; Yunju JO ; Eunju LEE ; Dongryeol RYU ; Seongbin HONG ; Beom-Jun KIM
Endocrinology and Metabolism 2025;40(1):73-81
Background:
Sclerostin, initially recognized for its pivotal role in bone metabolism, has gained attention for its multifaceted impact on overall human health. However, its influence on frailty—a condition that best reflects biological age—has not been thoroughly investigated.
Methods:
We collected blood samples from 244 older adults who underwent comprehensive geriatric assessments. Sclerostin levels were quantified using an enzyme-linked immunosorbent assay. Frailty was assessed using two validated approaches: the phenotypic model by Fried and the deficit accumulation frailty index (FI) by Rockwood.
Results:
After controlling for sex, age, and body mass index, we found that serum sclerostin levels were significantly elevated in frail individuals compared to their robust counterparts (P<0.001). There was a positive correlation between serum sclerostin concentrations and the FI (P<0.001). Each standard deviation increase in serum sclerostin was associated with an odds ratio of 1.87 for frailty (P=0.003). Moreover, participants in the highest quartile of sclerostin levels had a significantly higher FI and a 9.91-fold increased odds of frailty compared to those in the lowest quartile (P=0.003 and P=0.039, respectively).
Conclusion
These findings, which for the first time explore the association between circulating sclerostin levels and frailty, have significant clinical implications, positioning sclerostin as one of potential blood-based biomarkers for frailty that captures the comprehensive physical, mental, and social aspects of the elderly, extending beyond its traditional role in bone metabolism.

Result Analysis
Print
Save
E-mail