1.AI-ECG Supported Decision-Making for Coronary Angiography in Acute Chest Pain: The QCG-AID Study
Jiesuck PARK ; Joonghee KIM ; Soyeon AHN ; Youngjin CHO ; Yeonyee E. YOON
Journal of Korean Medical Science 2025;40(12):e105-
		                        		
		                        			
		                        			 This pilot study evaluates an artificial intelligence (AI)-assisted electrocardiography (ECG) analysis system, QCG, to enhance urgent coronary angiography (CAG) decision-making for acute chest pain in the emergency department (ED). We retrospectively analyzed 300 ED cases, categorized as non-coronary chest pain (Group 1), acute coronary syndrome (ACS) without occlusive coronary artery disease (CAD) (Group 2), and ACS with occlusive CAD (Group 3). Six clinicians made urgent CAG decision using a conventional approach (clinical data and ECG) and a QCG-assisted approach (including QCG scores). The QCG-assisted approach improved correct CAG decisions in Group 2 (36.0% vs. 45.3%, P = 0.003) and Group 3 (85.3% vs. 90.0%, P = 0.017), with minimal impact in Group 1 (92.7% vs. 95.0%, P = 0.125). Diagnostic accuracy for ACS improved from 77% to 81% with QCG assistance and reached 82% with QCG alone, supporting AI's potential to enhance urgent CAG decisionmaking for ED chest pain cases. 
		                        		
		                        		
		                        		
		                        	
2.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
		                        		
		                        			 Purpose:
		                        			Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS. 
		                        		
		                        			Materials and Methods:
		                        			Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05. 
		                        		
		                        			Results:
		                        			Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS. 
		                        		
		                        			Conclusion
		                        			A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS. 
		                        		
		                        		
		                        		
		                        	
3.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
		                        		
		                        			 Purpose:
		                        			Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS. 
		                        		
		                        			Materials and Methods:
		                        			Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05. 
		                        		
		                        			Results:
		                        			Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS. 
		                        		
		                        			Conclusion
		                        			A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS. 
		                        		
		                        		
		                        		
		                        	
4.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
		                        		
		                        			 Purpose:
		                        			Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS. 
		                        		
		                        			Materials and Methods:
		                        			Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05. 
		                        		
		                        			Results:
		                        			Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS. 
		                        		
		                        			Conclusion
		                        			A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS. 
		                        		
		                        		
		                        		
		                        	
5.AI-ECG Supported Decision-Making for Coronary Angiography in Acute Chest Pain: The QCG-AID Study
Jiesuck PARK ; Joonghee KIM ; Soyeon AHN ; Youngjin CHO ; Yeonyee E. YOON
Journal of Korean Medical Science 2025;40(12):e105-
		                        		
		                        			
		                        			 This pilot study evaluates an artificial intelligence (AI)-assisted electrocardiography (ECG) analysis system, QCG, to enhance urgent coronary angiography (CAG) decision-making for acute chest pain in the emergency department (ED). We retrospectively analyzed 300 ED cases, categorized as non-coronary chest pain (Group 1), acute coronary syndrome (ACS) without occlusive coronary artery disease (CAD) (Group 2), and ACS with occlusive CAD (Group 3). Six clinicians made urgent CAG decision using a conventional approach (clinical data and ECG) and a QCG-assisted approach (including QCG scores). The QCG-assisted approach improved correct CAG decisions in Group 2 (36.0% vs. 45.3%, P = 0.003) and Group 3 (85.3% vs. 90.0%, P = 0.017), with minimal impact in Group 1 (92.7% vs. 95.0%, P = 0.125). Diagnostic accuracy for ACS improved from 77% to 81% with QCG assistance and reached 82% with QCG alone, supporting AI's potential to enhance urgent CAG decisionmaking for ED chest pain cases. 
		                        		
		                        		
		                        		
		                        	
6.AI-ECG Supported Decision-Making for Coronary Angiography in Acute Chest Pain: The QCG-AID Study
Jiesuck PARK ; Joonghee KIM ; Soyeon AHN ; Youngjin CHO ; Yeonyee E. YOON
Journal of Korean Medical Science 2025;40(12):e105-
		                        		
		                        			
		                        			 This pilot study evaluates an artificial intelligence (AI)-assisted electrocardiography (ECG) analysis system, QCG, to enhance urgent coronary angiography (CAG) decision-making for acute chest pain in the emergency department (ED). We retrospectively analyzed 300 ED cases, categorized as non-coronary chest pain (Group 1), acute coronary syndrome (ACS) without occlusive coronary artery disease (CAD) (Group 2), and ACS with occlusive CAD (Group 3). Six clinicians made urgent CAG decision using a conventional approach (clinical data and ECG) and a QCG-assisted approach (including QCG scores). The QCG-assisted approach improved correct CAG decisions in Group 2 (36.0% vs. 45.3%, P = 0.003) and Group 3 (85.3% vs. 90.0%, P = 0.017), with minimal impact in Group 1 (92.7% vs. 95.0%, P = 0.125). Diagnostic accuracy for ACS improved from 77% to 81% with QCG assistance and reached 82% with QCG alone, supporting AI's potential to enhance urgent CAG decisionmaking for ED chest pain cases. 
		                        		
		                        		
		                        		
		                        	
7.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
		                        		
		                        			 Purpose:
		                        			Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS. 
		                        		
		                        			Materials and Methods:
		                        			Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05. 
		                        		
		                        			Results:
		                        			Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS. 
		                        		
		                        			Conclusion
		                        			A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS. 
		                        		
		                        		
		                        		
		                        	
8.AI-ECG Supported Decision-Making for Coronary Angiography in Acute Chest Pain: The QCG-AID Study
Jiesuck PARK ; Joonghee KIM ; Soyeon AHN ; Youngjin CHO ; Yeonyee E. YOON
Journal of Korean Medical Science 2025;40(12):e105-
		                        		
		                        			
		                        			 This pilot study evaluates an artificial intelligence (AI)-assisted electrocardiography (ECG) analysis system, QCG, to enhance urgent coronary angiography (CAG) decision-making for acute chest pain in the emergency department (ED). We retrospectively analyzed 300 ED cases, categorized as non-coronary chest pain (Group 1), acute coronary syndrome (ACS) without occlusive coronary artery disease (CAD) (Group 2), and ACS with occlusive CAD (Group 3). Six clinicians made urgent CAG decision using a conventional approach (clinical data and ECG) and a QCG-assisted approach (including QCG scores). The QCG-assisted approach improved correct CAG decisions in Group 2 (36.0% vs. 45.3%, P = 0.003) and Group 3 (85.3% vs. 90.0%, P = 0.017), with minimal impact in Group 1 (92.7% vs. 95.0%, P = 0.125). Diagnostic accuracy for ACS improved from 77% to 81% with QCG assistance and reached 82% with QCG alone, supporting AI's potential to enhance urgent CAG decisionmaking for ED chest pain cases. 
		                        		
		                        		
		                        		
		                        	
9.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
		                        		
		                        			 Purpose:
		                        			Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS. 
		                        		
		                        			Materials and Methods:
		                        			Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05. 
		                        		
		                        			Results:
		                        			Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS. 
		                        		
		                        			Conclusion
		                        			A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS. 
		                        		
		                        		
		                        		
		                        	
10.Hyperkalemia Detection in Emergency Departments Using Initial ECGs:A Smartphone AI ECG Analyzer vs. Board-Certified Physicians
Donghoon KIM ; Joo JEONG ; Joonghee KIM ; Youngjin CHO ; Inwon PARK ; Sang-Min LEE ; Young Taeck OH ; Sumin BAEK ; Dongin KANG ; Eunkyoung LEE ; Bumi JEONG
Journal of Korean Medical Science 2023;38(45):e322-
		                        		
		                        			 Background:
		                        			Hyperkalemia is a potentially fatal condition that mandates rapid identification in emergency departments (EDs). Although a 12-lead electrocardiogram (ECG) can indicate hyperkalemia, subtle changes in the ECG often pose detection challenges. An artificial intelligence application that accurately assesses hyperkalemia risk from ECGs could revolutionize patient screening and treatment. We aimed to evaluate the efficacy and reliability of a smartphone application, which utilizes camera-captured ECG images, in quantifying hyperkalemia risk compared to human experts. 
		                        		
		                        			Methods:
		                        			We performed a retrospective analysis of ED hyperkalemic patients (serum potassium ≥ 6 mmol/L) and their age- and sex-matched non-hyperkalemic controls. The application was tested by five users and its performance was compared to five board-certified emergency physicians (EPs). 
		                        		
		                        			Results:
		                        			Our study included 125 patients. The area under the curve (AUC)-receiver operating characteristic of the application’s output was nearly identical among the users, ranging from 0.898 to 0.904 (median: 0.902), indicating almost perfect interrater agreement (Fleiss’ kappa 0.948). The application demonstrated high sensitivity (0.797), specificity (0.934), negative predictive value (NPV) (0.815), and positive predictive value (PPV) (0.927). In contrast, the EPs showed moderate interrater agreement (Fleiss’ kappa 0.551), and their consensus score had a significantly lower AUC of 0.662. The physicians’ consensus demonstrated a sensitivity of 0.203, specificity of 0.934, NPV of 0.527, and PPV of 0.765. Notably, this performance difference remained significant regardless of patients’ sex and age (P < 0.001 for both). 
		                        		
		                        			Conclusion
		                        			Our findings suggest that a smartphone application can accurately and reliably quantify hyperkalemia risk using initial ECGs in the ED. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail