1.Long-term results of synovectomy in total knee arthroplasty: a prospective, randomized controlled trial.
Weinan ZENG ; Zeping YU ; Simeng WANG ; Anjing CHEN ; Yiping ZENG ; Qingjun YANG ; Yujuan LI ; Qi LI ; Zongke ZHOU
Chinese Medical Journal 2023;136(1):73-81
BACKGROUND:
Synovectomy has been introduced into total knee arthroplasty (TKA) with the aim of relieving pain and inflammation of the synovium. However, there are no long-term, comparative data to evaluate the effect of synovectomy in TKA. This study was aimed at assessing pain, function, and complications in patients undergoing synovectomy during TKA for osteoarthritis (OA) at long-term follow-up.
METHODS:
This was a prospective randomized controlled trial of 42 consecutive patients who underwent staged bilateral TKA. Patients undergoing the first-side TKA were allocated to receive TKA with or without synovectomy followed by a 3-month washout period and crossover to the other strategy for the opposite-side TKA. The overall efficacy of both strategies was evaluated by determination of blood loss, the Knee Society score (KSS), and knee inflammation conditions during a 3-month postoperative period. The postoperative pain, range of motion (ROM), and complications were sequentially evaluated to compare the two groups until 10 years after surgery.
RESULTS:
At the 10-year follow-up, both groups had a similarly significantly improved ROM (114.88 ± 9.84° vs. 114.02 ± 9.43°, t = 0.221, P = 0.815) and pain relief with no differences between the two groups (1.0 [1.0] vs. 1.0 [1.5], U = 789.500, P = 0.613). Similar changes in total blood loss, KSS, and knee inflammation were found in both groups during 3 months postoperatively ( P > 0.05). Additionally, there was no significant difference regarding complications and satisfaction between the two groups ( P > 0.05).
CONCLUSIONS:
Synovectomy in conjunction with TKA for primary OA does not seem to provide any benefit regarding postoperative pain, ROM, and satisfaction during a 10-year follow-up. In addition, it may not result in more blood loss and increased incidence of long-term complications. Based on our long-term findings, it should not be performed routinely.
TRIAL REGISTRATION
Chinese Clinical Trial Registry, ChiCTR-INR-16008245; https://www.chictr.org.cn/showproj.aspx?proj=13334 .
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Synovectomy/methods*
;
Osteoarthritis, Knee/surgery*
;
Prospective Studies
;
Pain, Postoperative
;
Inflammation/etiology*
;
Range of Motion, Articular
;
Knee Joint/surgery*
;
Treatment Outcome
;
Knee Prosthesis/adverse effects*
2.Coronal curvature of tibial leads to malalignment of tibial prosthesis after total knee arthroplasty.
Peng WU ; Jun-Zhe LANG ; Cong-Cong WU ; Lei CHEN ; Li-Li HE
China Journal of Orthopaedics and Traumatology 2022;35(1):54-58
OBJECTIVE:
To investigate the effect of tibial coronal curvature on the alignment of tibial prosthesis in patients undergoing total knee arthroplasty (TKA).
METHODS:
From July 2019 to April 2021, 100 patients with knee osteoarthritis were treated with total knee arthroplasty. Before operation, the full-length films of lower limbs were taken and the tibial bowing angle(TBA) was measured. TBA more than 2° was tibial bending, which was divided into tibial bending group and non bending group. There were 40 cases in tibial bending group, 9 males and 31 females, aged 56 to 84 years old with an average of (69.22±7.10) years. There were 60 cases in the non bending group, 19 males and 41 females, aged from 51 to 87 years old with an average of (70.80±7.21) years. The preoperative tibial length (TL) and medial proximal tibial angle (MPTA) were measured and compared between the two groups. The full-length X-rays of the lower limbs were taken again 3 days to 1 week after operation. The medial angle of the tibial component coronal aligement angle (TCCA) and the outilier rate of force line of the tibial prosthesis were measured and compared between the two groups. Pearson method was used to analyze the correlation between TCCA and age, TCCA and height, TCCA and weight, TCCA and BMI, TCCA and TBA, TCCA and TL, TCCA and MPTA; Spearman method was used to analyze the correlation between TCCA and gender, TCCA and Kellgren-Lawrence(K-L) grade.
RESULTS:
All 100 patients successfully completed the operation and obtained satisfactory full-length X-rays in standing position. There was no significant difference in TL, MPTA and TCCA between bending group and non bending group(P>0.05). The outilier rate of force line in tibial bending group was 22.5%, and that in non bending group was 6.67%, the difference was statistically significant(P<0.05). The correlation study found that TCCA was strongly correlated with TBA(r=-0.702, P<0.01), weakly correlated with MPTA(r=0.311, P<0.01), and had no correlation with other parameters(P>0.05).
CONCLUSION
In patients with knee osteoarthritis undergoing total knee arthroplasty, tibial bending will lead to poor force line of tibial prosthesis. During operation, attention should be paid to osteotomy of proximal tibial vertical tibial mechanical axis and correct installation of prosthesis to avoid poor alignment of prosthesis.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Female
;
Humans
;
Knee Joint/surgery*
;
Knee Prosthesis/adverse effects*
;
Male
;
Middle Aged
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Tibia/surgery*
3.Research progress on the revision of Metal-on-Metal hip arthroplasty due to adverse reactions to metal debris.
Xin WANG ; Mei-Ping YANG ; Hong-Liang LIU ; Ze-Xin HUANG ; Shu-Chai XU
China Journal of Orthopaedics and Traumatology 2022;35(1):95-98
The choice of friction interface has always been a controversial topic in hip arthroplasty. Although the metal-on-metal (MoM) interface has gradually faded out of our vision, its revision is a clinical difficulty. Adverse reactions to metal debris (ARMD) is the most common indication for MoM hip arthroplasty revision, and the clinical results of hip arthroplasty due to ARMD are not satisfactory. At present, the indications and suggestions for revision of ARMD are not uniform. In this article, the clinical diagnosis, indications of revision, risk factors of prognosis, intraoperative suggestions and reasons for revision of ARMD were summarized. This article briefly introduces the diagnosis and treatment strategies and precautions of hip arthroplasty due to ARMD, in order to provide reference for such patients in clinical practice.
Arthroplasty, Replacement, Hip/adverse effects*
;
Hip Prosthesis/adverse effects*
;
Humans
;
Metal-on-Metal Joint Prostheses/adverse effects*
;
Prosthesis Design
;
Prosthesis Failure
;
Reoperation
4.The instability of wrist joint and total wrist replacement.
Chinese Journal of Traumatology 2016;19(1):49-51
Total wrist arthroplasty are not used as widely as total knee and hip replacement. The functional hands are requiring surgeons to design a durable and functional satisfying prosthesis. This article will list the main reasons that cause the failure of the prosthesis. Some remarkable and representative prostheses are listed to show the devolvement of total wrist prosthesis and their individual special innovations to fix the problems. And the second part we will discuss the part that biomechanical elements act in the total wrist replacement (TWA). Summarize and find out what the real problem is and how we can find a way to fix it.
Arthroplasty, Replacement
;
adverse effects
;
methods
;
Biomechanical Phenomena
;
Humans
;
Joint Instability
;
therapy
;
Joint Prosthesis
;
adverse effects
;
Wrist Joint
;
surgery
5.Angiosarcoma around Hip Joint Prosthesis.
Wei ZHU ; Bin FENG ; Qi MA ; Yu-Long LI ; Xi-Tao SONG ; Xi-Sheng WENG
Chinese Medical Journal 2016;129(21):2642-2643
6.Clinics in diagnostic imaging (167). Total shoulder arthroplasty glenoid component loosening with secondary rotator cuff failure.
Tien Jin TAN ; Ahmad Mohammad ALJEFRI ; Marc Bruce ELLIOTT ; Savvas NICOLAOU
Singapore medical journal 2016;57(4):172-quiz 177
A 59-year-old woman who had previously undergone an anatomic left total shoulder arthroplasty presented with increasing left shoulder pain and significant reduction in motion of the left shoulder joint. No evidence of prosthetic loosening or periprosthetic fracture was detected on the radiographs or fluoroscopic arthrogram images. Dual-energy computed tomography (DECT) images revealed evidence of loosening of the glenoid component and secondary rotator cuff failure. This case illustrates how a combination of detailed clinical history, careful physical examination and DECT arthrogram evaluation may be used to identify complications of an anatomic total shoulder arthroplasty.
Arthroplasty, Replacement, Shoulder
;
adverse effects
;
Diagnostic Imaging
;
Female
;
Humans
;
Middle Aged
;
Osteoarthritis
;
diagnosis
;
surgery
;
Prosthesis Design
;
Prosthesis Failure
;
Range of Motion, Articular
;
Reoperation
;
Rotator Cuff
;
diagnostic imaging
;
Shoulder Joint
;
diagnostic imaging
;
physiopathology
;
surgery
7.Clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
Peng CHEN ; Min ZENG ; Jie XIE ; Long WANG ; Weiping SU ; Yihe HU
Journal of Central South University(Medical Sciences) 2016;41(9):955-961
OBJECTIVE:
To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
METHODS:
A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect.
RESULTS:
Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (P<0.05). The clinical and function KSS scores showed that the improvement rate was 80%.
CONCLUSION
Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis combined with mild to moderate valgus knee deformity. The correction of deformity and improvement of joint function can be achieved significantly. The clinical result is satisfactory and patients' quality of life is improved.
Arthroplasty, Replacement, Knee
;
adverse effects
;
methods
;
Blood Loss, Surgical
;
Humans
;
Knee Joint
;
abnormalities
;
Knee Prosthesis
;
Operative Time
;
Osteoarthritis, Knee
;
surgery
;
Osteophyte
;
surgery
;
Osteotomy
;
Pain, Postoperative
;
therapy
;
Patella
;
surgery
;
Quality of Life
;
Tibia
;
Treatment Outcome
8.The impingement of sciatic nerve by acetabular prosthesis after revision hip arthroplasty: a case report.
Wei-jie XU ; Dong-song LI ; Xing-yu ZHAO ; Wei FENG ; Jian-guo LIU
China Journal of Orthopaedics and Traumatology 2015;28(1):52-54
Aged
;
Aged, 80 and over
;
Arthroplasty
;
methods
;
Hip Joint
;
surgery
;
Hip Prosthesis
;
adverse effects
;
Humans
;
Male
;
Nerve Compression Syndromes
;
etiology
;
Sciatic Neuropathy
;
etiology
9.The Parameters Affecting the Success of Irrigation and Debridement with Component Retention in the Treatment of Acutely Infected Total Knee Arthroplasty.
Jae Gyoon KIM ; Ji Hoon BAE ; Seung Yup LEE ; Won Tae CHO ; Hong Chul LIM
Clinics in Orthopedic Surgery 2015;7(1):69-76
BACKGROUND: The aims of our study were to evaluate the success rate of irrigation and debridement with component retention (IDCR) for acutely infected total knee arthroplasty (TKA) (< 4 weeks of symptom duration) and to analyze the factors affecting prognosis of IDCR. METHODS: We retrospectively reviewed 28 knees treated by IDCR for acutely infected TKA from 2003 to 2012. We evaluated the success rate of IDCR. All variables were compared between the success and failure groups. Multivariable logistic regression analysis was also used to examine the relative contribution of these parameters to the success of IDCR. RESULTS: Seventeen knees (60.7%) were successfully treated. Between the success and failure groups, there were significant differences in the time from primary TKA to IDCR (p = 0.021), the preoperative erythrocyte sedimentation rate (ESR; p = 0.021), microorganism (p = 0.006), and polyethylene liner exchange (p = 0.017). Multivariable logistic regression analysis of parameters affecting the success of IDCR demonstrated that preoperative ESR (odds ratio [OR], 1.02; p = 0.041), microorganism (OR, 12.4; p = 0.006), and polyethylene liner exchange (OR, 0.07; p = 0.021) were significant parameters. CONCLUSIONS: The results show that 60.7% of the cases were successfully treated by IDCR for acutely infected TKA. The preoperative ESR, microorganism, and polyethylene liner exchange were factors that affected the success of IDCR in acutely infected TKA.
Adult
;
Aged
;
Aged, 80 and over
;
Anti-Bacterial Agents/therapeutic use
;
Arthroplasty, Replacement, Knee/*adverse effects
;
Arthroscopy
;
Debridement
;
Female
;
Humans
;
Joint Diseases/microbiology/surgery/therapy
;
Knee Joint/microbiology/*surgery
;
Knee Prosthesis/microbiology
;
Male
;
Middle Aged
;
Prosthesis-Related Infections/etiology/microbiology/*therapy
;
Retrospective Studies
;
Therapeutic Irrigation
;
Treatment Outcome
10.The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner.
Hong Suk KWAK ; Jeong Joon YOO ; Young Kyun LEE ; Kyung Hoi KOO ; Kang Sup YOON ; Hee Joong KIM
Clinics in Orthopedic Surgery 2015;7(1):46-53
BACKGROUND: Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. METHODS: Twenty-three hips of 23 patients were identified because they showed metallosis during revision total hip arthroplasties performed in Seoul National University Hospital between January 1996 and August 2004. They were followed for at least 6.5 years after the index revision total hip arthroplasty. The clinical and radiological results of revision total hip arthroplasties in these patients were evaluated. RESULTS: The median Harris hip score increased from 60 points before revision total hip arthroplasties to 90 points at the final follow-up. Osteolysis was detected at an average of 9.3 years after revision total hip arthroplasties in 13 hips and acetabular cup loosening at average 9.8 years after revision total hip arthroplasties in 9 hips. With radiographic evidence of osteolysis and loosening as the end points, the 15-year survival rates were 28.2% and 56.0%, respectively. CONCLUSIONS: The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.
Adolescent
;
Adult
;
*Arthroplasty, Replacement, Hip
;
Biocompatible Materials
;
Female
;
Hip Joint/radiography/surgery
;
Hip Prosthesis/*adverse effects
;
Humans
;
Joint Diseases/radiography/*surgery
;
Male
;
Metals/adverse effects
;
Metals, Heavy/*poisoning
;
Middle Aged
;
Osteolysis/etiology/surgery
;
Poisoning/etiology/*surgery
;
Polyethylene/adverse effects
;
Prosthesis Design
;
*Prosthesis Failure/etiology
;
Reoperation
;
Young Adult

Result Analysis
Print
Save
E-mail