1.Correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis
Yunxiao YANG ; Chenglan HUANG ; Yutong HOU ; Yuan YAO ; Yu ZHAO ; Yuanjing XU ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3879-3884
BACKGROUND:Patients with degenerative cervical spondylosis often suffer from changed varicosity of the cervical spine,unbalanced neck-shoulder muscular strength,and descending power. OBJECTIVE:To probe into the correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis. METHODS:Totally 50 patients with degenerative cervical spondylosis received treatment at the 3D Printed Outpatient Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2022 to March 2023 were included in the study.After excluding the 10 patients of cervical lateral projection that failed to meet the measurement conditions,the cervical lateral projections were shot to measure the following iconography parameters:Borden value and C2-7 Cobb angle as well as pain thresholds on the midpoint of the superior trapezius muscle in bilateral bundles and at 1 cm beside the C5-6 interspike.The correlation between sagittal curvature parameters and pain threshold of neck-shoulder muscles in degenerative cervical spondylosis was analyzed. RESULTS AND CONCLUSION:(1)The Borden value of sagittal curvature showed a moderately positive correlation with the bundle pain threshold in the left upper trapezius muscle,the bundle pain threshold in the right upper trapezius muscle,and the pain threshold at the 1 cm of the left side beside the C5-6 interspike(r=0.498,P<0.01;r=0.448,P<0.05;r=0.405,P<0.05)and a weak positive correlation with the pain threshold at the 1 cm of the right side beside the C5-6 interspike(r=0.322,P<0.05).(2)The C2-7 Cobb angle showed a weak positive correlation with the left squared myalgia threshold(r=0.355,P<0.05),and there was no correlation with the pain threshold of the left trapezius muscle and the pain threshold at the 1 cm of both sides beside the C5-6 interspike.(3)There was a correlation between the pain threshold of the neck-shoulder muscles,and a high correlation between the pain threshold of the left and right muscles and the pain threshold within the left and right side muscles,indicating that the neck-shoulder muscles are consistent and may be related to the coordination of the neck-shoulder movements.
2.3D printed personalized cervical orthopedic brace can alleviate and treat early cervical spondylosis
Yunxiao YANG ; Yu ZHAO ; Minghai WANG ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(29):4639-4644
BACKGROUND:Short-term wearing of cervical brace combined with shoulder and neck muscle exercise can significantly improve the symptoms of early cervical spondylosis.After stopping wearing cervical brace,patients'symptoms are easy to recur,which may be due to the lack of cervical curvature correction function. OBJECTIVE:To analyze the effect of 3D printed personalized cervical orthopedic brace for adjusting cervical curvature in the treatment of early cervical spondylosis. METHODS:From January 2021 to January 2023,30 patients with early cervical spondylosis in the Shanghai Fifth People's Hospital,Fudan University were studied,including 11 males and 19 females,with a mean age of(31.7±6.6)years old.All patients customized and wore 3D printed personalized cervical orthopedic braces for 3 hours a day for continuous 12 weeks.Borden value of cervical curvature,pain threshold of shoulder and neck muscles,cervical dysfunction index,and visual analog scale score in 30 patients were recorded before and 4 and 8 weeks after treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,the difference of Borden value of cervical curvature,right trapezius tenderness threshold,and cervical dysfunction index was not significant in 30 patients after 4 weeks of treatment(P>0.05).Visual analog scale score,left trapezius tenderness threshold,left and right C5C6 tenderness threshold were significantly improved(P<0.05).(2)Compared with before treatment,the cervical curvature Borden value,left and right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold,and cervical dysfunction index of 30 patients were significantly improved after 12 weeks of treatment(P<0.05).(3)Compared with 4 weeks after treatment,the Borden value of cervical curvature,right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold and cervical dysfunction index of 30 patients after 12 weeks of treatment were significantly improved(P<0.05).(4)The results show that short-term wearing of 3D printed personalized cervical orthopedic brace can improve the pain of patients with early cervical spondylosis,while long-term application has certain effect on the recovery of cervical curvature.
3.Multi-criteria decision model in treatment of adolescent scoliosis with three-dimensional printed scoliosis orthosis
Hongsheng ZHANG ; Hanwei HUANG ; Jinwu WANG ; Junwei ZHENG ; Rixin LIU ; Zijie LIAO ; Peng WANG ; Yuanjing XU ; Zanbo WANG ; Keming WAN
Chinese Journal of Tissue Engineering Research 2024;28(30):4806-4811
BACKGROUND:Traditional scoliosis orthosis has some disadvantages,such as complex manufacturing process,long processing cycle,poor fit and so on.Three-dimensional printed scoliosis orthosis has the advantages of high manufacturing precision and personalization. OBJECTIVE:To evaluate the efficacy of three-dimensional printed scoliosis orthosis for scoliosis based on multi-criteria decision model. METHODS:Clinical data of 72 patients with scoliosis admitted to Chen Xinghai Hospital of Integrated Traditional Chinese and Western Medicine from January 2019 to October 2022 were retrospectively collected and divided into two groups according to the treatment of orthosis.Study group(n=23)received three-dimensional printed scoliosis orthosis.Traditional group(n=49)received the traditional polypropylene spine brace treatment.The clinical efficacy and complications were compared between the two groups.A multi-criteria decision model for the treatment of scoliosis with three-dimensional printed scoliosis orthosis was established,and the stability of the benefit value,risk value and decision model of the two groups were evaluated. RESULTS AND CONCLUSION:(1)Compared with the traditional group,there were significant differences in the top vertebral offset distance,Cobb angle,top vertebral rotation,Functional Movement Screen score,visual analog scale score and total effective rate in the study group at 6 months after surgery(P<0.05).(2)Among the benefit indexes,Cobb angle had the greatest impact on the condition of patients,while the risk indexes had the greatest impact on dyspnea.(3)The benefit values of the study group and the traditional group for scoliosis were 79 and 64,and the risk values were 74 and 57,respectively.The combined benefit and risk values found that the benefit-risk value of the study group was 16 higher than that of the traditional group.(4)In the range of 0-100%relative risk weight,the benefit-risk value of the study group was always higher than that of the traditional group,which proved that the multi-criteria decision-making model had good stability.(5)It is indicated that three-dimensional printed scoliosis orthosis can better restore the physiological curvature of scoliosis and improve the efficiency of treatment.
4.Effect of photon cervical vertebra massage instrument on improving neck pain and related functions in patients with chronic neck pain
Yuan YAO ; Shizhen ZHANG ; Lei JIN ; Yunxiao YANG ; Wenqiang YU ; Yuanjing XU ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4876-4880
BACKGROUND:Red light therapy has the non-invasive and cost-effective characteristics,and is widely used in various acute and chronic pains in clinic.However,currently,the phototherapy equipment used in clinic is expensive and has certain site limitations,so it is necessary to explore more convenient and economical phototherapy applications. OBJECTIVE:To observe the clinical efficacy of a self-developed photon cervical vertebra massage instrument for chronic neck pain. METHODS:From November 2022 to February 2023,24 patients with chronic neck pain were recruited from the Department of Rehabilitation Medicine,Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine,including 18 females and 6 males,with a mean age of(29.67±6.40)years.The body mass index was(21.39±3.52)kg/m2.Photon cervical vertebra massage instrument was used twice a day for 20 minutes each time for four weeks.The changes in visual analog scale score,pressure pain threshold,neck active activity,neck disability index,and Pittsburgh sleep quality index were observed before,after 2 and 4 weeks of treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,after four weeks of treatment,visual analog scale score,pressure pain threshold,neck disability index,and Pittsburgh sleep quality index were all improved(P<0.05),while some cervical motion(extension,left and right rotation)improved(P<0.05)after 4 weeks of treatment.(2)Bilateral visual analog scale scores,left trapezius muscle pressure pain threshold,C5C6 pressure pain threshold,and neck disability index improved after 2 weeks of treatment(P<0.05).(3)It is indicated that the application of photon cervical vertebra massage instrument can improve the pain score,muscle tenderness,sleep quality,functional level,and partial active activity of patients with chronic neck pain in a short period,and is a convenient,effective,and safe treatment method.
5.Correlation between lumbar spine and pelvic parameters in Lenke type 5 adolescent idiopathic scoliosis
Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Ya LI ; Peiwu GUO ; Wenqiang YU ; Yu ZHAO ; Zanbo WANG ; Hong ZENG ; Zhenjiang MA ; Dezhi LU ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5753-5758
BACKGROUND:The study of the lumbar spine and pelvis in patients with Lenke type 5 lordosis is limited to the coronal and sagittal planes,and the three-dimensional relationship between the scoliosis and the pelvis has not yet been clarified. OBJECTIVE:To analyze the effect of lumbar scoliosis on the pelvis in patients with Lenke type 5 lordosis and to study the correlation between the lumbar spine and the three-dimensional spatial position of the pelvis. METHODS:Imaging data of 60 patients with Lenke type 5 lordosis scoliosis admitted to the 3D Printing Reception Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2019 to September 2023 were retrospectively analyzed,including Cobb angle,coronal pelvic tilt,lumbar lordosis,left and right pelvic hip width ratio(sacroiliac-anterior superior iliac spine),spinal rotation angle,pelvic tilt,sacral slope,pelvic incidence,coronal deformity angular ratio,sagittal deformity angular ratio,C7 plumb line-center sacral vertical line,apical vertebral translation,and coronal sacral inclination.The information was summarized as a database.SPSS 22.0 software was used to analyze the data related to the lumbar spine and pelvis of the patients with Lenke type 5 primary lumbar curvature adolescent idiopathic scoliosis using Spearman's correlation analysis and linear regression. RESULTS AND CONCLUSION:(1)Cobb angle was highly positively correlated with coronal deformity angular ratio,apical vertebral translation,and spinal rotation angle(r=0.91,r=0.841,r=0.736).(2)Coronal deformity angular ratio was highly positively correlated with apical vertebral translation(r=0.737),moderately positively correlated with C7 plumb line-center sacral vertical line(r=0.514),and moderately negatively correlated with sagittal deformity angular ratio(r=-0.595).(3)There was a high positive correlation between lumbar lordosis and sagittal deformity angular ratio(r=0.942)and a moderate negative correlation with coronal deformity angular ratio(r=-0.554).(4)There was a moderate positive correlation between Cobb angle with coronal pelvic tilt and coronal sacral inclination(r=0.522,r=0.534)and a moderate positive correlation between C7 plumb line-center sacral vertical line and coronal pelvic tilt(r=0.507).Apical vertebral translation with coronal pelvic tilt and coronal sacral inclination showed a moderate positive correlation(r=0.507,r=0.506).Lumbar lordosis with sacral slope and pelvic incidence showed a moderate positive correlation(r=0.512,r=0.538).Sagittal deformity angular ratio was moderately positively correlated with sacral slope and pelvic incidence(r=0.614,r=0.621).(5)Studies have found that the relative position of the lumbar spine and the pelvis is closely related in the horizontal,sagittal and coronal planes.When the lumbar spine affects scoliosis and is rotated,the relative position of the pelvis will also change to compensate,which indicates that while correcting scoliosis,the correction of the pelvis cannot be ignored.
6.Printing Process Quality Control of Bioprinting Medical Devices
Neng XIE ; Qixin CAO ; Jinwu WANG ; Yuanjing XU ; Changru ZHANG ; Ya WANG ; Zitong WANG
Chinese Journal of Medical Instrumentation 2024;48(3):245-250
Objective This study analyzes the risk points in the quality control of bioink and the main processes of bioprinting,clarifies and explores the quality control and supervision model for bioprinting medical devices,and provides theoretical and practical guidance to ensure the safety and effectiveness of bioprinting medical devices.Methods The quality control risk points throughout the bioprinting process were comprehensively analyzed,with a particular focus on bioprinting materials and key processes.The regulatory model and methods for bioprinting medical devices were examined.This research concentrated on critical technologies such as extrusion,laser-assisted,and in situ bioprinting,assessing their potential for clinical applications and regulatory challenges.Results Bioink from different sources should meet regulatory requirements.It is essential to ensure aseptic handling of raw materials and to validate sterilization under"worst-case"conditions.Conclusion As bioprinting technology advances rapidly,corresponding research into materials,processes,and quality risk control should be conducted to ensure the concurrent development of the regulatory system.This will continuously contribute to the orderly progression of the entire industry and human health.
7.Overview of Key Technologies in Surgical Robots and Optimization Discussions
Xunjun MA ; Jun YU ; Haitao LIU ; Ya LI ; Hao WU ; Yanbo HUANG ; Bide XU ; Li LIN ; Jinwu WANG
Chinese Journal of Medical Instrumentation 2024;48(5):505-511
Surgical robot is the national strategic diagnostic and therapeutic equipment research focus,get a number of scientific research institutes,colleges and universities and enterprises pay extensive attention to the design and development of a variety of surgical robots,and registration declaration.This article explores the critical technologies of surgical robots and key areas for optimizing their performance,including kinematic positioning errors,pose errors,feedback model errors,image recognition positioning errors,path planning,and safety aspects.The findings not only provide a scientific basis for future standardization research on surgical robots but also offer significant theoretical and practical references for the research,manufacturing,and registration processes in the medical robotics industry.
8.Application of fluoroscopic stereophotogrammetric analysis in the detection of aseptic loosening of prostheses
Han YANG ; Hao LEI ; Bide XU ; Hao WU ; Xunjun MA ; Yanbo HUANG ; Yuanqing MAO ; Jingwei ZHANG ; Jinwu WANG
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(9):1061-1068
Objective·To verify the accuracy and clinical feasibility of fluoroscopic stereophotogrammetric analysis(FSA)technology based on two dimension(2D)-three dimension(3D)registration for early migration detection of aseptic loosening of joint prostheses.Methods·2D-3D registration algorithms centering on the light source and projected object respectively in FSA technology were verified under various working conditions through image synthesis experiments,and the feasibility of clinical application was verified through real model experiments.The image synthesis experiment established a perspective projection environment with the same parameters as the real environment in a virtual environment,the 2D perspective images of the 3D model(bone or prosthesis)during the six degrees of freedom transformation were recorded,and the six degrees of freedom transformation of the 3D model was restored by using different 2D-3D registration algorithms.The error of each registration algorithm was calculated.For real model validation,the migration between bone and prosthesis after joint replacement surgery was simulated with a high precision bone prosthesis migration simulator.The 3D model of the bone or prosthesis was reconstructed by using computed tomograph(CT)images and optical scanning,and the 2D perspective images before and after prosthesis migration were captured by using a fluoroscopy device.The migration of the prosthesis was restored by using FSA technology based on 2D-3D registration,and the error of FSA technology was calculated.Results·The accuracy of the 2D-3D registration algorithm centering on the light source was higher than that of the algorithm centering on the projected object under different working conditions.When the initial registration conditions were favorable,the algorithm centering on the light source reduced the rotation error compared to the algorithm centering on the projected object,with a statistical difference(P=0.021),and the displacement error decreases,with a significant statistical difference(P=0.000).Moreover,algorithms centering on the light sources required lower similarity and fewer registration times to meet clinical application requirements.Conclusion·The accuracy of FSA technology based on 2D-3D registration in early migration detection of artificial joint prostheses meets clinical application requirements.This technology can warn of late aseptic loosening of prostheses by detecting early migration of prostheses after joint replacement surgery,and is expected to be applied to clinical practice through further research.
9.Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly (version 2023)
Yan HU ; Dongliang WANG ; Xiao CHEN ; Zhongmin SHI ; Fengjin ZHOU ; Jianzheng ZHANG ; Yanxi CHEN ; Liehu CAO ; Sicheng WANG ; Jianfei WANG ; Hongliang WANG ; Yong FENG ; Zhimin YING ; Chengdong HU ; Qinglin HAN ; Ming LI ; Xiaotao CHEN ; Zhengrong GU ; Biaotong HUANG ; Liming XIONG ; Yunfei ZHANG ; Zhiwei WANG ; Baoqing YU ; Yong WANG ; Lei ZHANG ; Lei YANG ; Peijian TONG ; Ximing LIU ; Qiang ZHOU ; Feng NIU ; Weiguo YANG ; Wencai ZHANG ; Shijie CHEN ; Jinpeng JIA ; Qiang YANG ; Tao SHEN ; Bin YU ; Peng ZHANG ; Yong ZHANG ; Jun MIAO ; Kuo SUN ; Haodong LIN ; Yinxian YU ; Jinwu WANG ; Kun TAO ; Daqian WAN ; Lei WANG ; Xin MA ; Chengqing YI ; Hongjian LIU ; Kun ZHANG ; Guohui LIU ; Dianying ZHANG ; Zhiyong HOU ; Xisheng WENG ; Yingze ZHANG ; Jiacan SU
Chinese Journal of Trauma 2023;39(4):289-298
Periarticular fracture of the shoulder is a common type of fractures in the elderly. Postoperative adverse events such as internal fixation failure, humeral head ischemic necrosis and upper limb dysfunction occur frequently, which seriously endangers the exercise and health of the elderly. Compared with the fracture with normal bone mass, the osteoporotic periarticular fracture of the shoulder is complicated with slow healing and poor rehabilitation, so the clinical management becomes more difficult. At present, there is no targeted guideline or consensus for this type of fracture in China. In such context, experts from Youth Osteoporosis Group of Chinese Orthopedic Association, Orthopedic Expert Committee of Geriatrics Branch of Chinese Association of Gerontology and Geriatrics, Osteoporosis Group of Youth Committee of Chinese Association of Orthopedic Surgeons and Osteoporosis Committee of Shanghai Association of Chinese Integrative Medicine developed the Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly ( version 2023). Nine recommendations were put forward from the aspects of diagnosis, treatment strategies and rehabilitation of osteoporotic periarticular fracture of the shoulder, hoping to promote the standardized, systematic and personalized diagnosis and treatment concept and improve functional outcomes and quality of life in elderly patients with osteoporotic periarticular fracture of the shoulder.
10.Corrective effect of 3D printed scoliosis orthoses
Wenqiang YU ; Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Dezhi LU ; Caiping WANG ; Jinwu WANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(4):390-395
ObjectiveTo investigate the in-brace and short-term correction of 3D-printed scoliosis orthoses. MethodsFrom July to December 2021, 36 patients with adolescent idiopathic scoliosis from Ninth People's Hospital, Shanghai Jiaotong University School of Medicine were selected to complete full-length radiographs of the spine before and immediately after wearing the orthosis. They wore the orthosis more than 20 hours a day, and took radiographs six months later. Cobb angle was calculated. They were assessed with Chinese version of the Scoliosis Research Society's outcomes instrument 22 (SRS-22) before wearing and six months follow-up. ResultsThe mean Cobb angle was (22.10±6.29)° before wearing, and it was (7.85±10.90)° immediately after wearing (t = 4.775, P < 0.01) and (14.33±0.74)° six months follow-up (t = 4.189, P < 0.01). The score of functional status of SRS-22 increased six months follow-up (Z = -2.676, P < 0.01). The Cobb angle immediately after wearing correlated with the Cobb angle six months follow-up (r = 0.826, P < 0.05). Conclusion3D-printed scoliosis orthoses can correct the scoliosis satisfactorily, in-brace and in short-term.

Result Analysis