1.Hepatitis E virus infection among blood donors in Hangzhou
Ziyun DU ; Wenjun DENG ; Danxiao WU ; Jinhui LIU ; Jie DONG
Chinese Journal of Blood Transfusion 2025;38(1):19-25
[Objective] To investigate the infection and characteristics of hepatitis E virus among blood donors in Hangzhou. [Methods] A total of 5 075 blood samples of blood donors from Zhejiang Provincial Blood Center from September to November 2023 were collected, including 5 037 samples with normal ALT and 38 samples with elevated ALT (>50 U/L). Enzyme-linked immunosorbent assay (ELISA) was used to detect anti-HEV IgM, anti-HEV IgG and HEV-Ag. The Fisher test and Chi-square test were used to evaluate the difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among different levels of ALT. The distribution characteristics of HEV screening in blood donors were analyzed. Univariate and multivariate logistic regression were used to analyze the susceptibility factors of anti-HEV IgM and anti-HEV IgG seropositivity, and the anti-HEV IgM-reactive blood donors were followed up by telephone. [Results] The reactivity rates of anti-HEV IgM, anti-HEV IgG and HEV-Ag in 5 075 blood samples were 0.45%, 22.98% and 0%, respectively. There was no difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among different levels of ALT (P>0.05), and the results of univariate and multivariate logistic regression analysis showed that age was a risk factor for anti-HEV IgM and anti-HEV IgG reactivity in blood donors (P<0.05), while no difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among blood donors was noticed in gender, occupation and education level (P>0.05). [Conclusion] There is a potential risk of transfusion-transmitted HEV (TT-HEV) in Hangzhou, and a cost-effective HEV screening strategy needs to be established to continue regular HEV surveillance in Hangzhou to assess the risk of infection.
2.STAR Guideline Terminology (I): Planning and Launching
Zhewei LI ; Qianling SHI ; Hui LIU ; Xufei LUO ; Zijun WANG ; Jinhui TIAN ; Long GE ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(1):216-223
To develop a guideline terminology system and promote its standardization, thereby enhancing medical staff's accurate understanding and correct application of guidelines. A systematic search was conducted for guideline development manuals and method ological literature (as of October 25, 2024). After screening, relevant terms from the guideline planning and launching stages were extracted and standardized. The term list and definitions were finalized through discussion and evaluation at a consensus conference. A total of 36 guideline manuals and 14 method ological articles were included, and 27 core terms were identified. The standardization of guideline terminology is essential for improving guideline quality, facilitating interdisciplinary communication, and enhancing other related aspects. It is recommended that efforts to advance the standardization and continuous updating of the terminology system should be prioritized in the future to support the high-quality development of guidelines.
3.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
4.Influence evaluation of pharmaceutical quality control on medication therapy management services by the ECHO model
Kun LIU ; Huanhuan JIANG ; Yushuang LI ; Yan HUANG ; Qianying ZHANG ; Dong CHEN ; Xiulin GU ; Jinhui FENG ; Zijian WANG ; Yunfei CHEN ; Yajuan QI ; Yanlei GE ; Aishuang FU
China Pharmacy 2025;36(9):1123-1128
OBJECTIVE To evaluate the influence of pharmaceutical quality control on the efficiency and outcomes of standardized medication therapy management (MTM) services for patients with coronary heart disease by using Economic, Clinical and Humanistic Outcomes (ECHO) model. METHODS This study collected case data of coronary heart disease patients who received MTM services during January-March 2023 (pre-quality control implementation group, n=96) and June-August 2023 (post-quality control implementation group, n=164). Using propensity score matching analysis, 80 patients were selected from each group. The study subsequently compared the economic, clinical, and humanistic outcome indicators of pharmaceutical services between the two matched groups. RESULTS There were no statistically significant differences in baseline data between the two groups after matching (P>0.05). Compared with pre-quality control implementation group, the daily treatment cost (16.26 yuan vs. 24.40 yuan, P<0.001), cost-effectiveness ratio [23.12 yuan/quality-adjusted life year (QALY) vs. 32.32 yuan/QALY, P<0.001], and the incidence of general adverse drug reactions (2.50% vs. 10.00%, P=0.049) of post-quality control implementation group were decreased significantly; the utility value of the EuroQol Five-Dimensional Questionnaire (0.74± 0.06 vs. 0.71±0.07, P=0.003), the reduction in the number of medication related problems (1.0 vs. 0.5, P<0.001), the medication adherence score ([ 6.32±0.48) points vs. (6.10±0.37) points, P=0.001], and the satisfaction score ([ 92.56±1.52) points vs. (91.95±1.56) points, P=0.013] all showed significant improvements. Neither group experienced serious adverse drug reactions. There was no statistically significant difference in the incidence of new adverse reactions between the two groups (1.25% vs. 3.75%, P=0.310). CONCLUSIONS Pharmaceutical quality control can improve the quality of pharmaceutical care, and the ECHO model can quantitatively evaluate the effect of MTM services, making pharmaceutical care better priced and more adaptable to social needs, thus being worthy of promotion.
5.Application,research hotspots,and shortcomings of degradable zinc-based alloys in bone defect repair and reconstruction
Haoyang LIU ; Qiang XIE ; Mengran SHEN ; Yansong REN ; Jinhui MA ; Bailiang WANG ; Debo YUE ; Weiguo WANG
Chinese Journal of Tissue Engineering Research 2025;29(4):839-845
BACKGROUND:Zinc-based alloy medical implant materials have excellent mechanical properties,complete degradability and good biocompatibility,and are mainly used in orthopedic implants,cardiovascular stents,bile duct stents,tracheal stents,nerve catheters,etc. OBJECTIVE:To review the research progress of biodegradable zinc-based alloys in bone defect repair and prospect the promising research direction and achievements of zinc-based materials. METHODS:After searching PubMed,Web of Science,WanFang Data,and CNKI databases from the establishment of the database to June 2023,various relevant articles on biodegradable zinc-based alloys for bone implant material research were collected.The basic characteristics of biodegradable zinc based alloys were summarized,and the role of zinc-based alloys in promoting bone tissue repair was sorted and summarized.The current research hotspots and shortcomings were discussed. RESULTS AND CONCLUSION:(1)Zinc-based alloys have good biocompatibility.Using zinc-based alloys as the matrix material,with the help of scaffold structure construction technology and coating optimization process,the bone conductivity of zinc-based alloys will be effectively improved,and their degradation products will have efficient bone induction to regulate the gene expression of osteoblasts and osteoclasts,thereby promoting the repair and reconstruction of bone defects.(2)However,in the research on optimizing zinc-based alloys,the coating process is relatively insufficient,and additive loading technology is still lacking.(3)Zinc-based alloys have excellent mechanical and biological properties.Through special processes,their bone conductivity and osteoinductivity can be increased to effectively improve their ability to promote bone repair and reconstruction,and it is expected to further achieve the development of personalized transplant materials.Further research and development are needed to optimize the integration of coating and additive loading technologies into zinc-based alloys.
6.STAR Guideline Terminology(Ⅱ): Clinical Question Formulation, Evidence Retrieval and Appraisal, and Recommendation Development
Di ZHU ; Haodong LI ; Zijun WANG ; Qianling SHI ; Hui LIU ; Yishan QIN ; Yuanyuan YAO ; Zhewei LI ; Hongfeng HE ; Jinhui TIAN ; Long GE ; Yaolong CHEN ;
Medical Journal of Peking Union Medical College Hospital 2025;16(3):756-764
To introduce and analyze guideline terminology related to clinical question formulation, evidence retrieval and appraisal, and recommendation development. A systematic search was conducted in guideline development manuals and relevant methodological literature, covering publications up to October 25, 2024. Terminology related to the three aforementioned stages of related to guideline development was extracted from the included literature, standardized, and refined through consensus meetings to finalize a comprehensive terminology list and definitions. A total of 30 guideline development manuals and 15 methodological articles were included, and 23 core terms were identified. It is recommended to develop a standardized and scientifically sound guideline terminology system with unified naming, clear definitions, and alignment with the linguistic environment and usage habits in China. At the same time, it is essential to strengthen terminology training for both guideline developers and users based on this system, in order to deepen their correct understanding and proper application of guideline terminology.
7.Predictive value of ultrasound radiomics models for benign and malignant BI-RADS 4 breast lesions
Qiao ZOU ; Jinhui LIU ; Xiaoling LENG ; Tuerhong ZUMURETI ; Xiwen FAN
Chinese Journal of Radiological Health 2025;34(2):179-185
Objective To evaluate the efficiency of intra-tumor and peri-tumor ultrasound radiomics models based on machine learning algorithms for predicting benign and malignant Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions, and provide insights into early diagnosis of breast cancer. Methods A retrospective analysis was conducted based on the medical records of 450 female patients who underwent breast ultrasound examination in the Affiliated Cancer Hospital of Xinjiang Medical University from June 2020 to April 2022. The patients were divided into the benign (n = 199) and malignant (n = 195) groups according to pathological examination, and randomized into the training (n = 275) and validation (n = 119) sets at a ratio of 7∶3. Radiomics features were extracted and screened. Intra-tumor, peri-tumor, and intra-tumor + peri-tumor ultrasound radiomics models were constructed based on three machine learning algorithms, including logistic regression (LR), support vector machine (SVM), and multi-layer perceptron (MLP). Receiver operating characteristics (ROC) curves, calibration curves, and decision curves were plotted to evaluate the efficacy of the radiomics models for prediction of benign and malignant breast lesions. Results A total of 17 intra-tumor, 16 peri-tumor, and 17 intra-tumor + peri-tumor radiomics features were selected for model construction. Based on LR, MLP, and SVM algorithms, the intra-tumor + peri-tumor radiomics models showed higher predictive efficacy than intra-tumor and peri-tumor radiomics models. The predictive efficacy of intra-tumor, peri-tumor, and intra-tumor + peri-tumor radiomics models were higher based on the SVM algorithm than based on LR and MLP algorithms. For the intra-tumor radiomics model based on the SVM algorithm, the area under the ROC curve (AUC), accuracy, sensitivity, and a specificity were 0.909, 0.851, 0.860, and 0.842, respectively, in the training set and 0.866, 0.832, 0.847, and 0.817, respectively, in the validation set. For the peri-tumor radiomics model based on the SVM algorithm, these values were 0.899, 0.855, 0.882, and 0.827, respectively, in the training set and 0.844, 0.815, 0.847, and 0.783, respectively, in the validation set. For the intra-tumor + peri-tumor radiomics model based on the SVM algorithm, these values were 0.943, 0.876, 0.860, and 0.892, respectively, in the training set and 0.881, 0.849, 0.915, and 0.783, respectively, in the validation set. Conclusion The intra-tumor and peri-tumor ultrasound radiomics models based on machine learning algorithms are highly valuable for prediction of benign and malignant BI-RADS 4 breast lesions. The intra-tumor + peri-tumor ultrasound radiomics model based on the SVM algorithm has the optimal efficacy for prediction of benign and malignant BI-RADS 4 breast lesions.
8.Enhancing Disciplinary Development Through Journal Columns: Taking the "Clinical Practice Guidelines"Column in Medical Journal of Peking Union Medical College Hospital as an Example
Meihua WU ; Hui LIU ; Qi ZHOU ; Qianling SHI ; Na LI ; Yule LI ; Xiaoqing LIU ; Kehu YANG ; Jinhui TIAN ; Long GE ; Bin MA ; Xiuxia LI ; Xuping SONG ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1315-1324
To explore the role of the "Clinical Practice Guidelines" column and others in the We collected papers published by the Lanzhou University Evidence-Based Medicine Center team in the "Clinical Practice Guidelines" column and others from 2018 to 2025. These publications were analyzed across multiple dimensions, including authorship and institutional affiliations, citation metrics, and research themes and content. A total of 59 papers were included in the analysis, with authors representing 70 domestie and international research institutions. The cumulative citation count was 639, with the highest single-paper citation frequency reaching 101. The average citation per paper was 10.8, and total downloads exceeded 30 000. The content focused on key themes such as guideline terminology, development methodology, guideline evaluation, and dissemination and implementation. The evolution of research topics progressed from critiques of common misconceptions and hot topies in the field to multidimensional evaluations of thecurrent state of Chinese guidelines, culminating in the fommulation of industry standards for guidelines. These contributions have provided critical references for translating guideline theory into practice in China and have garnered widespread attention and discussion among scholars in the field. The "Clinical Practice Guidelines" column and others in the
9.Single Kocher-Langenbeck approach combined with anterograde channel screw technique in treatment of acetabular transverse and posterior wall fractures.
Xuepeng XU ; Jinhui LIU ; Lincong FEI ; Junwu YE
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):35-39
OBJECTIVE:
To assess the effectiveness of the single Kocher-Langenbeck approach combined with anterograde channel screw technique for the treatment of acetabular transverse and posterior wall fractures.
METHODS:
Between March 2020 and October 2022, 17 cases of acetabular transverse and posterior wall fractures were treated with the single Kocher-Langenbeck approach combined with anterograde channel screw technique. There were 11 males and 6 females, with an average age of 53.6 years (range, 42-64 years). Causes of injury included traffic accident in 12 cases, and falling from height in 5 cases. The time from injury to operation ranged from 4 to 16 days with an average of 8.8 days. The operation time, intraoperative blood loss, and fluoroscopy frequency were recorded; X-ray films were reviewed regularly after operation to observe the fracture healing, and postoperative complications were recorded. At last follow-up, Matta score was used to evaluate the reduction of fracture, Harris score and modified Merle D'Aubigné-Postel scores system were used to evaluate the hip joint function.
RESULTS:
The operation time was 150-230 minutes (mean, 185.9 minutes), the intraoperative blood loss was 385-520 mL (mean, 446.2 mL), and the fluoroscopy frequency was 18-34 times (mean, 27.5 times). Postoperative fat liquefaction occurred in 1 case and the other incisions healed by first intention; 3 cases had limb numbness after operation, and the symptoms disappeared after active symptomatic treatment; no urogenital system and intestinal injury occurred. All patients were followed up 12-28 months (mean, 19.9 months). Bone union was achieved in all cases with an average healing time of 10.8 weeks (range, 8-14 weeks). There was no complication such as loosening and breakage of internal fixators. At last follow-up, according to Matta score, 12 cases achieved anatomic reduction, 3 satisfactory reduction, and 2 fair reduction, the satisfactory rate was 88.2%; according to Harris hip function score, 12 cases were excellent, 3 good, and 2 fair, the excellent and good rate was 88.2%; according to the modified Merle D'Aubign Aubigné-Postel scoring system, the results were excellent in 11 cases, good in 3 cases, and fair in 3 cases, with an excellent and good rate of 82.4%.
CONCLUSION
The single Kocher-Langenbeck approach combined with anterograde channel screw technique is a minimally invasive method for the treatment of acetabular transverse and posterior wall fractures with less complications, simple operation, and satisfactory effectiveness.
Male
;
Female
;
Humans
;
Middle Aged
;
Blood Loss, Surgical
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Acetabulum/injuries*
;
Bone Screws
;
Hip Fractures/surgery*
;
Retrospective Studies
10.The moderating role of estradiol in the relationship between parenting styles and preschool children s behavioral problems
XIA Moyan, YAN Chao, DONG Suhua, TANG Jinhui, LIU Ying, SONG Xingxing, TAO Lan, YAO Rongying
Chinese Journal of School Health 2024;45(1):95-98
Objective:
To explore the moderating role of estradiol in the relationship between parenting styles and preschool children's behavioral problems, so as to provide a theoretical basis for improving the development of human s emotional health development in early life stage.
Methods:
During September to November in 2022, 354 children aged 3-6 years and their parents from two kindergartens in Bengbu City were chosen by using stratified cluster sampling method for the questionnaire survey. The Parenting Style Scale and the Child Behavior Checklist (CBCL) were used to collect information on parenting style and child behavioral problems. Salivary estradiol of children was collected and tested. Independent samples t test was applied to compare the scores of the scale for parental up bringing and children s behavioral problems, and Pearson correlation analysis was conducted to explore the relationship among parental upbringing, estradiol and children s behavioral problems.
Results:
Parents doting, laissez faire, autocratic, and inconsistent parenting styles were positive associated with child behavior problems( r =0.14-0.70); fathers democratic parenting style was negatively associated with child behavior problems( r =-0.14,-0.22,-0.21,-0.17,-0.27,-0.20); mothers democratic parenting styles was negatively correlated with scores on all five dimensions of child behavior problems except the withdrawal dimension ( r =-0.14,-0.12,-0.13,-0.21,-0.12)( P <0.05). Estradiol levels had significant moderating effects on maternal doting parenting style and children s withdrawal ( β =0.68) as well as social problems ( β =-1.00), also moderating laissez faire parenting styles and children s withdrawal problems ( β =0.75)( P <0.05). For children with low levels of estradiol, withdrawal problem scores were negatively associated with mother s doting parenting style and positively associated with laissez faire parenting style, and socialization problem scores were associated with mother s doting parenting style; for children with high levels of estradiol, withdrawal problem scores were positively associated with mother s doting parenting style, and socialization problem scores were associated with mother s doting parenting style ( t=2.84, 6.24, 3.16 , 2.37, 4.49, P <0.05).
Conclusions
Parenting styles are strongly associated with child behavioral problems; estradiol levels play a moderating role in mothers doting, laissez faire parenting styles and children s withdrawal problems and social problems.Parents should adopt more positive parenting styles and focus on the role of estradiol levels in maternal education to reduce the occurrence of behavioral problems in children.


Result Analysis
Print
Save
E-mail