1.Suspected adverse events following immunization of domestic bivalent human papillomavirus vaccine in primary and secondary school girls in Hebei Province
WANG Yihan, WANG Yafei, WANG Jinghui, HAO Ling, LI Jing, SUN Li, WANG Lina
Chinese Journal of School Health 2026;47(1):117-120
Objective:
To analyze adverse event following immunization(AEFI) with the domestic bivalent human papilloma virus (HPV) vaccine among female students in primary, junior, and senior high schools in Hebei Province from 2022 to 2024, aiming to provide evidence for the vaccination program.
Methods:
On May 14, 2025, AEFI case data and vaccination data for the domestic bivalent HPV vaccine among female students in primary, junior, and senior high schools in Hebei Province from 2022 to 2024 were collected from the China Disease Control and Prevention Information System and the Hebei Provincial Immunization Program Information Management System, respectively. Statistical analysis was performed by using descriptive and analytical epidemiological methods, with intergroup comparisons conducted by using the Chi square test or Fisher s exact probability test.
Results:
From 2022 to 2024, a total of 817 900 doses of the domestic bivalent HPV vaccine were administered to female students in primary, junior, and senior high schools in Hebei Province. A total of 68 AEFI cases were reported, comprising 57 common vaccine reactions, 7 rare vaccine reactions, 3 coincidental events, and 1 psychogenic reaction. The overall AEFI reporting rate was 8.31 per 100 000 doses, 4 cases (2.30/100 000 doses), 31 cases (8.73/100 000 doses), and 33 cases (11.41/100 000 doses) were reported in 2022, 2023, and 2024, respectively, with a statistically significant difference across years ( χ 2=10.97, P <0.01). The reporting rates for common and rare vaccine reactions were 6.97 per 100 000 doses and 0.86 per 100 000 doses, respectively. The AEFI reporting rates were 15.14 per 100 000 doses among primary school girls and 8.20 per 100 000 doses among secondary school girls, though the difference was not statistically significant (Fisher s exact test, P =0.30). The reporting rate was higher after the first dose (10.91/100 000 doses) than after the second dose (5.96/100 000 doses; χ 2=5.85, P =0.02).The second quarter recorded the highest AEFI reporting rate at 11.21 per 100 000 doses. The majority of AEFI cases (56 cases, 82.35%) occurred within 24 hours post vaccination.
Conclusion
The domestic bivalent HPV vaccine demonstrates a favorable safety profile among female students in Hebei Province, with a low overall AEFI reporting rate that consisted predominantly of general reactions and occasional cardiac related reactions.
2.New-onset conduction block after transcatheter aortic valve replacement: A retrospective analysis in a single center
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):372-376
Objective To investigate the new-onset conduction block after transcatheter aortic valve replacement (TAVR) and summarize the relevant experience. Methods The perioperative data of TAVR patients in the Second Hospital of Hebei Medical University from January 2016 to February 2023 were collected, and the new-onset incidence of conduction block after TAVR was analyzed retrospectively. Results Finally 352 patients were included, including 225 males and 127 females, with an average age of (67.2±5.1) years, among whom 256 patients were treated with Venus-A valves, 69 patients with Vita-Flow valves, and 27 patients with J-Valve valves. There were 38 (10.8%) patients of new-onset postoperative block. There were 6 (1.7%) patients of new-onset postoperative grade Ⅲ atrioventricular block, including 5 (2.0%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conduction function was restored in 2 patients within 14 days after surgery, and failed to be restored in 4 patients, who then received permanent pacemaker implantation in the Department of Cardiology. There were 27 (7.7%) patients of new left bundle branch block after surgery, including 22 (8.6%) patients of Venus-A, 4 (5.8%) patients of Vita-Flow and 1 (3.7%) patient of J-Valve; and conduction function was restored within 7 days after surgery in 23 patients, and 5 (1.4%) patients developed new right bundle branch blocks after surgery including 4 (1.5%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conclusion New-onset conduction block is a common complication after TAVR, and the new-onset rate of left bundle branch block is the highest, followed by the grade Ⅲ atrioventricular block. Mastering reasonable methods and applying appropriate strategies can effectively reduce the new-onset rate of postoperative conduction block and improve the overall success rate of TAVR surgery.
3.Evaluation of operation quality of measles surveillance system in Hebei Province in 2020 - 2023
Shiheng CUI ; Xiaomeng XU ; Li SUN ; Yafei WANG ; Wei WANG ; Yanli CONG ; Jinghui WANG
Journal of Public Health and Preventive Medicine 2025;36(2):26-29
Objective To analyze the operation of Measles Surveillance System (MSS) in Hebei Province, and to provide evidence for measles elimination. Methods Measles surveillance data was collected from the MSS from 2020 to 2023, and a modified weighted technology for order preference by similarity to an ideal solution (TOPSIS) method was used to evaluate the surveillance indexes of measles in Hebei Province. Results The operation quality of the measles surveillance system in Hebei Province was improved year by year, with the highest quality in 2023, and all the indicators reached the monitoring program standards. The quality of measles surveillance system was not balanced among cities, and the main influencing factor was the substandard sensitivity indicators. The quality of measles surveillance system was the highest in Baoding City and the lowest in Zhangjiakou City. Conclusion The measles surveillance system in Hebei province is running well, and the sensitivity of the surveillance system should be improved to keep the high-quality operation of the surveillance system.
4.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
5.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
6.Coronary artery stenosis associated with right ventricular dysfunction in acute pulmonary embolism: A case-control study.
Yuejiao MA ; Jieling MA ; Dan LU ; Yinjian YANG ; Chao LIU ; Liting WANG ; Xijie ZHU ; Xianmei LI ; Chunyan CHENG ; Sijin ZHANG ; Jiayong QIU ; Jinghui LI ; Mengyi LIU ; Kai SUN ; Xin JIANG ; Xiqi XU ; Zhi-Cheng JING
Chinese Medical Journal 2025;138(16):2028-2036
BACKGROUND:
The potential impact of pre-existing coronary artery stenosis (CAS) on right ventricular (RV) function during acute pulmonary embolism (PE) episodes remains underexplored. This study aimed to investigate the association between pre-existing CAS and RV dysfunction in patients with acute PE.
METHODS:
In this multicenter, case-control study, 89 cases and 176 controls matched for age were enrolled at three study centers (Peking Union Medical College Hospital, Fuwai Hospital, and the Second Affiliated Hospital of Harbin Medical University) from January 2016 to December 2020. The cases were patients with acute PE with CAS, and the controls were patients with acute PE without CAS. Coronary artery assessment was performed using coronary computed tomographic angiography. CAS was defined as ≥50% stenosis of the lumen diameter in any coronary vessel >2.0 mm in diameter. Conditional logistic regression analysis was used to evaluate the association between CAS and RV dysfunction.
RESULTS:
The percentages of RV dysfunction (19.1% [17/89] vs. 44.6% [78/176], P <0.001) and elevated systolic pulmonary artery pressure (sPAP) (19.3% [17/89] vs. 39.5% [68/176], P = 0.001) were significantly lower in the case group than those in the control group. In the multivariable logistic regression model, CAS was independently and negatively associated with RV dysfunction (adjusted odds ratio [OR]: 0.367; 95% confidence interval [CI]: 0.185-0.728; P = 0.004), and elevated sPAP (OR: 0.490; 95% CI: 0.252-0.980; P = 0.035), respectively.
CONCLUSIONS
Pre-existing CAS was significantly and negatively associated with RV dysfunction and elevated sPAP in patients with acute PE. This finding provides new insights into RV dysfunction in patients with acute PE with pre-existing CAS.
Humans
;
Pulmonary Embolism/complications*
;
Case-Control Studies
;
Male
;
Ventricular Dysfunction, Right/physiopathology*
;
Female
;
Middle Aged
;
Aged
;
Coronary Stenosis/complications*
;
Logistic Models
;
Adult
7.FOXO3-engineered human mesenchymal stem cells efficiently enhance post-ischemic stroke functional rehabilitation.
Fangshuo ZHENG ; Jinghui LEI ; Zan HE ; Taixin NING ; Shuhui SUN ; Yusheng CAI ; Qian ZHAO ; Shuai MA ; Weiqi ZHANG ; Jing QU ; Guang-Hui LIU ; Si WANG
Protein & Cell 2025;16(5):365-373
8.Single-nucleus transcriptomics decodes the link between aging and lumbar disc herniation.
Min WANG ; Zan HE ; Anqi WANG ; Shuhui SUN ; Jiaming LI ; Feifei LIU ; Chunde LI ; Chengxian YANG ; Jinghui LEI ; Yan YU ; Shuai MA ; Si WANG ; Weiqi ZHANG ; Zhengrong YU ; Guang-Hui LIU ; Jing QU
Protein & Cell 2025;16(8):667-684
Lumbar disc (LD) herniation and aging are prevalent conditions that can result in substantial morbidity. This study aimed to clarify the mechanisms connecting the LD aging and herniation, particularly focusing on cellular senescence and molecular alterations in the nucleus pulposus (NP). We performed a detailed analysis of NP samples from a diverse cohort, including individuals of varying ages and those with diagnosed LD herniation. Our methodology combined histological assessments with single-nucleus RNA sequencing to identify phenotypic and molecular changes related to NP aging and herniation. We discovered that cellular senescence and a decrease in nucleus pulposus progenitor cells (NPPCs) are central to both processes. Additionally, we found an age-related increase in NFAT1 expression that promotes NPPC senescence and contributes to both aging and herniation of LD. This research offers fresh insights into LD aging and its associated pathologies, potentially guiding the development of new therapeutic strategies to target the root causes of LD herniation and aging.
Intervertebral Disc Displacement/metabolism*
;
Humans
;
Aging/pathology*
;
Nucleus Pulposus/pathology*
;
Male
;
Female
;
Transcriptome
;
Middle Aged
;
Lumbar Vertebrae/pathology*
;
Adult
;
Cellular Senescence
;
Stem Cells/pathology*
;
Aged
;
Intervertebral Disc Degeneration/metabolism*
9.Short-term clinical efficacy of one-stop TAVR+PCI in the treatment of patients with aortic valve disease and coronary heart disease
Huajun WANG ; Hang ZHANG ; Tong SU ; Hongjuan LIAO ; Ziying CHEN ; Fengwu SHI ; Qianli MA ; Su LIU ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):848-852
Objective To analyze the short-term clinical efficacy and prognosis of one-stop transcatheter aortic valve replacement (TAVR)+percutaneous coronary intervention (PCI) in the treatment of aortic valve disease with coronary heart disease. Methods The clinical data of patients with aortic valve disease complicated with coronary heart disease who underwent one-stop TAVR+PCI treatment at the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University from January 2018 to June 2023 were retrospective analyzed. The preoperative and postoperative clinical data were compared, and 1-month follow-up results were recorded. Results A total of 37 patients were enrolled, including 22 males and 15 females, with an average age of 69.14±6.47 years. Thirty-six patients recovered and were discharged after the surgery, and 1 (2.7%) patient died during the surgery. Self-expanding TAVR valves were implanted through the femoral artery in all patients. One coronary artery was opened by PCI in 35 (94.6%) patients, and two coronary arteries were opened by PCI in 2 (5.4%) patients. All PCI opened arteries had a stenosis>70%. During the postoperative hospitalization, the complications included pulmonary infection in 11 (30.6%) patients, severe pneumonia in 10 (27.8%) patients, liver function injury in 14 (38.9%) patients, renal function injury in 5 (13.9%) patients, cerebral infarction in 1 (2.8%) patient, atrial fibrillation in 1 (2.8%) patient, ventricular premature beats in 2 (5.6%) patients, atrioventricular block in 2 (5.6%) patients, and complete left bundle branch block in 5 (13.9%) patients. The median postoperative ventilation assistance time was 12.0 (0.0, 17.0) h, the ICU monitoring time was 1.0 (0.0, 2.0) d, and the postoperative hospitalization time was 5.0 (4.0, 7.0) d. There was a significant improvement in the New York Heart Association cardiac function grading after surgery (P<0.001). After surgery, there were 21 (58.3%) patients had minor perivalve leakage, 6 (16.7%) patients had minor to moderate perivalve leakage, and no moderate or above degree of perivalve leakage. After one month of postoperative follow-up, 36 patients showed significant improvement in heart function. There were no patients with recurrent acute coronary syndrome, re-PCI, or cardiovascular system disease related re-hospitalization. Conclusion The one-stop TAVR+PCI treatment for patients with aortic valve disease and coronary heart disease can obtain satisfactory short-term clinical efficacy, which is worth further trying and studying.
10.Epidemiological characteristics and spatiotemporal clustering analysis on foodborne infection of Vibrio parahaemolyticus in Ningbo, 2014-2022
Danjie JIANG ; Yang YANG ; Yan ZHANG ; Yanbo GUO ; Jinghui WANG ; Hua GAO ; Qinghai GONG ; Jia HONG ; Feng TONG
Chinese Journal of Epidemiology 2024;45(9):1204-1208
Objective:To explore the epidemiological characteristics and spatiotemporal clustering of foodborne infection of Vibrio ( V.) parahaemolyticus in Ningbo, Zhejiang Province, from 2014 to 2022, and provide reference and evidence for the prevention and control of related diseases. Methods:The incidence data on of foodborne infection of V. parahaemolyticus in Ningbo from 2014 to 2022 were collected from Ningbo Foodborne Disease Surveillance System, and the case counts and the positive rates in different districts (counties, cities) were calculated. Spatial autocorrelation analysis and spatiotemporal scanning analysis were conducted to analyze the spatiotemporal clustering of the diseases. Results:A total of 1 822 cases of foodborne infection of V. parahaemolyticus were reported in Ningbo from 2014 to 2022, with an overall positive rate of 3.78%. Spatial autocorrelation analysis showed that the positive rate of foodborne infection of V. parahaemolyticus in Ningbo was unevenly distributed from 2014 to 2022, Ninghai was a high-high clustering area, while Zhenhai was a high-low clustering area, and Jiangbei was a low-low clustering area. The annual incidence was high during July-September. Spatiotemporal scanning analysis found one class Ⅰ spatiotemporal clustering area and three class Ⅱ spatiotemporal clustering areas, with the class Ⅰ spatiotemporal clustering area being observed in Jiangbei and Zhenhai from 2019 to 2022. Conclusions:Spatiotemporal clustering of foodborne infection of V. parahaemolyticus existed in Ningbo from 2014 to 2022, with an annual high incidence period from July to September. The key areas for the prevention and control of foodborne infection of V. parahaemolyticus are coastal districts (counties, cities) in Ningbo.


Result Analysis
Print
Save
E-mail