1.Clinical application of Mimics software system to three-dimensional reconstruction to guide thoracoscopic anatomic pulmonary segmentectomy
Shuang LI ; Yijun SHI ; Guowen DING ; Yangyong SUN ; Benbo LÜ ; ; Jianchao LIU ; Jingfeng ZHU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(01):59-64
Objective To investigate the clinical effect of 3D computed tomography bronchial bronchography and angiography (3D-CTBA) and guidance of thoracoscopic anatomic pulmonary segmentectomy by Mimics software system. Methods A retrospective analysis was performed on patients who underwent thoracoscopic segmentectomy in the Department of Thoracic Surgery of Affiliated People's Hospital of Jiangsu University from June 2020 to December 2022. The patients who underwent preoperative 3D-CTBA using Materiaise's interactive medical image control system (Mimics) were selected as an observation group, and the patients who did not receive 3D-CTBA were selected as a control group. The relevant clinical indicators were compared between the two groups. Results A total of 59 patients were included, including 29 males and 30 females, aged 25-79 years. There were 37 patients in the observation group, and 22 patients in the control group. The operation time (163.0±48.7 min vs. 188.8±43.0 min, P=0.044), intraoperative blood loss [10.0 (10.0, 20.0) mL vs. 20.0 (20.0, 35.0) mL, P<0.001], and preoperative puncture localization rate (5.4% vs. 31.8%, P=0.019) in the observation group were better than those in the control group. There was no statistically significant difference in the thoracic tube placement time, thoracic fluid drainage volume, number of intraoperative closure nail bin, postoperative hospital stay, or postoperative air leakage incidence (P>0.05) between the two groups. Conclusion For patients who need to undergo anatomical pulmonary segmentectomy, using Mimics software to produce 3D-CTBA before surgery can help accurately identify pulmonary arteriovenous anatomy, reduce surgical time and intraoperative blood loss, help to determine the location of nodules and reduce invasive localization before surgery, and alleviate patients' pain, which is worthy of clinical promotion.
2.Establishment of a method for detecting propofol concentration in plasma and its application in patients with lymphedema
Jingfeng LI ; Zhengyuan SHI ; Mengjie ZHANG ; Lei GUAN ; Dechun JIANG
China Pharmacy 2024;35(4):476-480
OBJECTIVE To establish a method for the determination of propofol concentration in human plasma and apply it in patients with lymphedema. METHODS The concentration of propofol was determined by UPLC-MS/MS after protein precipitation of plasma samples using thymol as internal standard. The sample was eluted on a Kinetex C18 column with a mobile phase consisting of acetonitrile (A)-water (B) for gradient elution at the flow rate of 200 μL/min. The sample size was 5 μL, and the column temperature was set at 40 ℃. The sample chamber temperature was 15 ℃. Using multi-reaction monitoring mode, the ion pairs for quantitative analysis were m/z 177.0→161.2 (propofol) and m/z 149.0→133.1 (internal standard), respectively. The above method was used to determine the plasma concentration of propofol in 6 patients with lymphedema. RESULTS The linear range of propofol was 50-5 000 ng/mL (r=0.995 0). RSDs of within- and between-batch precision were not more than 8.08%; no endogenous interference, carryover effect, or dilution effect was observed in blank plasma. The extraction recovery ranged from 89.80% to 93.73%, and matrix effects were within the range of 97.93%-101.73%. RSDs of the stability test were all lower than 3.27%. During intraoperative TCI 2-30 min, the plasma concentration of propofol in 6 patients was maintained in the range of 1 865.3-6 056.2 ng/mL, and the propofol was almost excreted within 4-8 h after operation. CONCLUSIONS The established UPLC-MS/MS method in this study can achieve the determination of propofol and a simple and fast sample pretreatment process without derivatization; it is proved to be suitable for the concentration monitoring of propofol in plasma samples of patients with lymphedema.
3.Current situation of medical students'understanding and use of teaching informationization platform un-der the background of education informationization
Xinzhu SHI ; Rongmei LI ; Shu LI ; Guangmei YUAN ; Jingfeng LI ; Xiucong PEI
Journal of Shenyang Medical College 2024;26(2):213-216
Objective:To gain insights into the cognitive processes and utilization patterns of medical students regarding teaching information platforms and resources,and aims to provide valuable references for the implementation of modern medical information technology in educational reforms.Methods:A survey was conducted among all voluntary medical students of grade 2019 to grade 2022.Questionnaire surveys and semi-open interviews were used to investigate.Results:The findings indicated that medical students possess a comprehensive understanding of various teaching platforms,with a high frequency of accessing course materials through these platforms.However,the browsing rate for case analyses recommended by teachers on these platforms remains relatively low.Students demonstrated awareness and utilization of quality courses,particularly MOOCs and micro-courses,which were more frequently utilized compared to other courses.Conclusion:Medical students have a strong awareness of information technology and the ability to solve academic problems through multiple platforms and channels.The construction of teaching platform resources needs to further optimize and improve its simplicity and affinity,and teachers should selectively push high-quality teaching resources to realize the rational application of medical information technology in teaching.
4.Research on Locating Device for the Entry Point of Intramedullary Nail Based on Inertial Navigation
Chu GUO ; Bobin MI ; Junwen WANG ; Jing JIAO ; Shilei WU ; Tian XIA ; Jingfeng LI ; Guohui LIU ; Mengxing LIU
Chinese Journal of Medical Instrumentation 2024;48(2):179-183
Objective To introduce a locating device for the entry point of intramedullary nail based on the inertial navigation technology,which utilizes multi-dimensional angle information to assist in rapid and accurate positioning of the ideal direction of femoral anterograde intramedullary nails'entry point,and to verify its clinical value through clinical tests.Methods After matching the locating module with the developing board,which are the two components of the locating device,they were placed on the skin surface of the proximal femur of the affected side.Anteroposterior fluoroscopy was performed.The developing angle corresponding to the ideal direction of entry point was selected based on the X-ray image,and then the yaw angle of the locating module was reset to zero.After resetting,the locating module was combined with the surgical instrument to guide the insertion angle of the guide wire.The ideal direction of entry point was accurately located based on the angle guidance.By setting up an experimental group and a control group for clinical surgical operations,the number of guide wire insertion times,surgical time,fluoroscopy frequency,and intraoperative blood loss with or without the locating device was recorded.Results Compared to the control group,the experimental group showed significant improvement in the number of guide wire insertion times,surgical time,fluoroscopy frequency,and intraoperative blood loss,with a statistically significant difference(P<0.01).Conclusion The locating device can assist doctors in quickly locating the entry point of intramedullary nail,effectively reducing the fluoroscopy frequency and surgical time by improving the success rate of the guide wire insertion with one shot,improving surgical efficiency,and possessing certain clinical value.
5.The factors affecting the prognosis of complex intracranial aneurysms treated with pipeline flow-direction device and the construction of a nomogram prediction model
Ziyin ZHANG ; Dong QIU ; Ping ZHENG ; Yang AN ; Tao ZHANG ; Xuesong TANG ; Zhixing YAN ; Suwen LI ; Liping YIN ; Yongji JIANG ; Ligang HU ; Jingfeng TANG
Journal of Interventional Radiology 2024;33(9):944-949
Objective To investigate the factors influencing the prognosis of complex intracranial aneurysms treated with pipeline flow-directed device(PED)and to develop a nomogram prediction model.Methods The clinical data of a total of 98 patients with complex intracranial aneurysm,who were admitted to the Anyue County People's Hospital or the Second Affiliated Hospital of Guilin Medical College of China from January 2021 to April 2023 to receive PED treatment,were retrospectively analyzed.The influencing factors that might affect the prognosis of patients with complex intracranial aneurysm were collected.According to the modified Rankin Scale(mRS)score,the patients were divided into good prognosis group(being defined as mRS ≤2 points)and poor prognosis group(being defined as mRS>2 points).The clinical data were compared between the two groups,and a nomogram model was established and validated.Results In the 98 patients,poor prognosis was seen in 10(10.20%).The differences in age,history of hypertension,history of diabetes mellitus,clopidogrel resistance,Fisher classification,repeated aneurysm rupture,aneurysm location,aneurysm size,aneurysm neck,multiple lesions,and Hunt-Hess grade on admission between good prognosis group and poor prognosis group were statistically significant(all P<0.05).Multivariate analysis revealed that history of hypertension,clopidogrel resistance,repeated aneurysm rupture,aneurysm location,multiple lesions,and Hunt-Hess grade were the independent factors influencing the prognosis of patients with complex intracranial aneurysm after receiving PED treatment.The AUC of the nomogram model in predicting the prognosis of PED for complex intracranial aneurysms was 0.849(95%CI=0.758-0.939).The predicted curves of the model group and validation group were basically fitted to the standard curves.The results of the decision curve analysis showed that the net benefit to patients was greater than 0 when the probability threshold of the nomogram model for predicting a poor prognosis of PED for complex intracranial aneurysms was 0.10-0.90.Conclusion The factors causing poor prognosis of PED for complex intracranial aneurysms mainly include history of hypertension,clopidogrel resistance,repeated aneurysm rupture,etc.The nomogram model established in this study can predict the risk of poor prognosis in patients with complicated intracranial aneurysm after receiving PED treatment.
6.ICD-10 coding of pelvic organ prolapse
Wenshan YANG ; Jingfeng YIN ; Jie WANG ; Chenlu LI
Modern Hospital 2024;24(9):1388-1390
Objective To accurately encode pelvic organ prolapse and ensure data accuracy.Methods ICD-10 coding analysis was performed in combination with the professional knowledge of the International Classification of Diseases(ICD-10)and specific clinical cases of pelvic organ prolapse.Results Vaginal anterior wall prolapse,regardless of severity,was encoded as N81.1;vaginal posterior wall prolapse,regardless of severity,as N81.6;uterine prolapse grade Ⅰ and Ⅱ,regardless of the presence or absence of vaginal anterior and posterior wall prolapse,as N81.2;uterine prolapse grade Ⅲ,whether the prolapse of the anterior and posterior vaginal walls is combined,or what level of the severity of the prolapse,as N81.3;cervical prolapse staging,regardless of severity or presence of vaginal anterior and posterior wall prolapse,as N81.2.In addition,the N81.-code does not include genital prolapse complicating pregnancy(O34.5),prolapse and hernia of ovary and fallopian tube(N83.4),vaginal fornix prolapse after hysterectomy(N99.3).Conclusion To ensure accurate coding,the composite coding rules must be cross-checked with volume one.ICD-10 failed to reflect the severity of vaginal prolapse in clinical practice.To consider the severity,coding should be extended in the N81.-segment.It is essential for coders to actively acquire clinical knowledge,rein-force professional knowledge,and enhance their responsibility to improve their coding proficiency and ensure data accuracy.
7.Application and prospects of robot-assisted pancreatic surgery
Chinese Journal of Digestive Surgery 2024;23(4):566-572
Pancreatic surgery is a high-risk and highly complex procedure, and there are a series of challenges and limitations associated with minimally invasive pancreatic surgery. With the development of robotic technology, robot-assisted pancreatic surgery has gradually become an effec-tive means, and has become an important approach in pancreatic surgeries. The authors summarize the technical characteristics, clinical applications, operation outcomes, and advantages and limita-tions of robot-assisted pancreatic surgery, aiming to explore the application of robot-assisted pan-creatic surgery in modern medicine and to provide an outlook on its future development.
8.The Effect of heparin solution sealing with different tube volumes on coagulation function in patients undergoing continuous renal replacement therapy
Ying MA ; Li FU ; Yingying LI ; Jin LIN ; Jingfeng LIU
Chinese Journal of Practical Nursing 2024;40(21):1628-1634
Objective:To investigate the influence of various volumes of heparinized saline seal on coagulation function in patients undergoing Continuous Renal Replacement Therapy (CRRT) with non-tunneled hemodialysis catheters.Methods:A randomized controlled trial was conducted on patients requiring catheter sealing during CRRT in the Department of intensive care unit, Beijing Friendship Hospital Affiliated to Capital Medical University from March 2021 to December 2022. Patients were randomly assigned to either the experimental group or the control group, The control group used 100% catheter volume of heparinized solution, while the experimental group used 80% catheter volume of heparinized solution. Compare the activated partial thromboplastin time (APTT), prothrombin time (PT), prothrombin activity (PTA), fibrinogen (Fbg), hemoglobin, platelets, and poor prognosis events (mainly including clotting, bleeding, bleeding inclination) between two groups of patients.Results:A total of 121 patients were included in the study, with 59 in the experimental group and 62 in the control group. In the control group, there were 39 males and 23 females, with an average age of (66.6 ± 18.2) years, while in the experimental group, there were 29 males and 30 females, with an average age of (65.2 ± 17.5) years. After catheter sealing, APTT and PT in the experimental group were (41.2 ± 7.6) s and (14.0 ± 0.8) s, respectively, both lower than the corresponding values in the control group [(48.1 ± 14.7) s and (16.2 ± 4.0) s], with statistically significant differences ( t=4.32, 4.08, both P<0.05). In the experimental group, PTA, fibrinogen levels, and platelet were (77.9 ± 12.5) s, (90.3 ± 10.1) g/L, and (151.3 ± 89.4) × 10 9/L, respectively, higher than the corresponding values in the control group (65.3 ± 17.2) s, (85.2 ± 5.2) g/L, and (110.0 ± 21.6) ×10 9/L, with statistically significant differences ( t=-4.59, -5.03, -5.59, all P<0.05). After the closure of the tube, the bleeding incidence rate in the experimental group was 1.7% (1/59), which was significantly lower than that in the control group at 12.9% (8/62), with statistically significant differences ( χ2=0.12, P<0.05). Conclusions:Heparin solution sealing with 80% lumen capacity improves coagulation function, reduces bleeding risk, and does not increase the incidence of catheter blockage.
9.Clinical application of domestic multi-port robot-assisted surgery system in distal pancreatectomy: a prospective, single-center, single-arm exploratory study
Jingfeng LI ; Zhiwei XU ; Xiaxing DENG ; Chenghong PENG ; Baiyong SHEN ; Yusheng SHI
Chinese Journal of Hepatobiliary Surgery 2024;30(5):325-329
Objective:To explore the safety and efficacy of Tumai domestic multi-port robot-assisted surgery system in the clinical application of distal pancreatectomy in pancreatic tumor patients.Methods:A prospective, single-center, single-arm exploratory study was conducted. A total of 20 patients who underwent robot-assisted pancreatic body-tail resection in Ruijin Hospital, Shanghai Jiao Tong University School of Medicine from March 2023 to November 2023 were enrolled, including 13 males and 7 females, aged (57.9±11.2) years. All the patients underwent robot-assisted distal pancreatectomy with Tumai multi-port surgical robot. Clinical data of complications, intraoperative blood loss, operative time, postoperative drainage tube retention time, and postoperative pathology were collected and statistically analyzed.Results:All the 20 patients underwent surgery successfully. Only 1 patient (5.0%) was diagnosed with pancreatic neuroendocrine tumor (G1 stage), and the rest were benign pancreatic tumors, including serous cystadenoma and mucinous cystadenoma. No instrument-related organ or blood vessel injury occurred, no intraoperative complications occurred. Of 7 patients (35.0%) had postoperative complications, including 3 infections, 3 abdominal effusion, and 1 hypokalemia. According to the Clavien-Dindo grading, all the cases were grade Ⅰ except 1 case with grade Ⅱ abdominal effusion. No serious complications above grade Ⅲ occurred. The intraoperative blood loss of the 20 patients was 100(20, 200) ml, the operative time was (125.7±76.9) min, and the postoperative retention time of drainage tube was (7.9±3.4) d.Conclusion:Tumai domestic multi-port robot-assisted surgery system has acceptable safety and efficacy in the clinical application of distal pancreatectomy.
10.Association of cumulative pulse pressure levels with the risk of metabolic syndrome
Peimeng ZHU ; Jingfeng CHEN ; Su YAN ; Youxiang WANG ; Haoshuang LIU ; Jiaoyan LI ; Suying DING
Chinese Journal of Endocrinology and Metabolism 2024;40(10):858-866
Objective:To explore the potential correlation between cumulative pulse pressure (cumPP) level and metabolic syndrome (MetS), and to provide insights for MetS management.Methods:A total of 3 968 subjects who underwent health checkup were selected to form a research cohort, and the data were categorized into three groups based on the tertiles of cumPP levels. Cox proportional hazards regression model was employed to analyze the association between different cumPP levels and the incidence of new-onset MetS. Results:The risk of MetS increased with the increased tiers of the cumPP levels (2.5%, 4.3%, and 4.6%, Ptrend<0.001) during the median follow-up period of 2.16 years. Spearman rank correlation analysis showed that cumPP was positively correlated with waist circumference, systolic blood pressure, diastolic blood pressure and fasting plasma glucose (all P<0.05). The Cox proportional hazards regression adjusted model showed that the risk of MetS in Q2 and Q3 was higher than that in Q1 in the total population, and the same results were observed in males (all P<0.05), while there was no statistical significance in females. Model 3 of the total population adjusted for a variety of confounding factors displayed a higher risk of MetS in Q3 compared with that in Q1[1.654 (95% CI 1.272-2.151) ]. When stratified by sex, and the risk of MetS in Q3 was 1.665 times higher than that in Q1 (95% CI 1.245-2.227), while there was no statistically significant risk in female. According to the visual nomogram of independent risk factors screened by multivariate analysis based on Cox proportional hazards regression model, the incidence of MetS at 1 year, 2 years, and 3 years was 0.18%, 3.97% and 7.39%, respectively. In addition, the dose-response curve was plotted according to cumPP, suggesting that the risk of MetS gradually increased with the increase of cumPP in the total population. Subgroup analyses based on baseline systolic blood pressure levels showed that higher cumPP levels were associated with a higher risk of developing MetS, regardless of whether systolic blood pressure was abnormal. Conclusions:Elevated cumPP levels is significantly related to the incidence of new-onset MetS. Maintaining pulse pressure within an appropriate range over long term is crucial for the management of MetS.

Result Analysis
Print
Save
E-mail