1.Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews:A retrospective cohort study
Eun-Hack ANDREW CHOI ; Dasomi KIM ; Liu JING ; Hyung-Seog YU ; Sung-Hwan CHOI ; Jung-Yul CHA
The Korean Journal of Orthodontics 2025;55(3):167-175
Objective:
To assess the success rate and proximity of miniscrews to the root using surgical guides produced by integrating data obtained from conebeam computed tomography and intraoral scanned models.
Methods:
This retrospective study involved 113 patients (224 miniscrews) who underwent miniscrew placement as part of their orthodontic treatment. Two operators placed miniscrews between the buccal alveolar bone of each patient and assessed initial stability by measuring the Periotest value (PTV) and insertion torque (IT). Patients were divided into two groups based on the miniscrew insertion method: manual group (MG) and surgical guide group (SG). Root proximity was assessed using periapical radiography, and miniscrews that remained in place for over 6 months were considered successful.
Results:
There was a statistically significant difference in the Kaplan–Meier survival curves between the groups (P < 0.05). The success rates of the miniscrews were 79.1% and 90.5% for the MG and SG, respectively (P < 0.05). The root contact rate also differed significantly between the groups (MG, 17.5%; SG, 0.1%; P < 0.001). However, the PTV and IT did not show significant differences between the groups.
Conclusions
Proximity to the root and utilization of surgical guides have the most direct impact on the success rate of miniscrews. Root proximity can be effectively reduced using surgical guides. Therefore, the use of a miniscrew surgical guide is recommended to increase the success rate of miniscrews as stable anchorage devices, particularly in cases with narrow interradicular space.
2.Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews:A retrospective cohort study
Eun-Hack ANDREW CHOI ; Dasomi KIM ; Liu JING ; Hyung-Seog YU ; Sung-Hwan CHOI ; Jung-Yul CHA
The Korean Journal of Orthodontics 2025;55(3):167-175
Objective:
To assess the success rate and proximity of miniscrews to the root using surgical guides produced by integrating data obtained from conebeam computed tomography and intraoral scanned models.
Methods:
This retrospective study involved 113 patients (224 miniscrews) who underwent miniscrew placement as part of their orthodontic treatment. Two operators placed miniscrews between the buccal alveolar bone of each patient and assessed initial stability by measuring the Periotest value (PTV) and insertion torque (IT). Patients were divided into two groups based on the miniscrew insertion method: manual group (MG) and surgical guide group (SG). Root proximity was assessed using periapical radiography, and miniscrews that remained in place for over 6 months were considered successful.
Results:
There was a statistically significant difference in the Kaplan–Meier survival curves between the groups (P < 0.05). The success rates of the miniscrews were 79.1% and 90.5% for the MG and SG, respectively (P < 0.05). The root contact rate also differed significantly between the groups (MG, 17.5%; SG, 0.1%; P < 0.001). However, the PTV and IT did not show significant differences between the groups.
Conclusions
Proximity to the root and utilization of surgical guides have the most direct impact on the success rate of miniscrews. Root proximity can be effectively reduced using surgical guides. Therefore, the use of a miniscrew surgical guide is recommended to increase the success rate of miniscrews as stable anchorage devices, particularly in cases with narrow interradicular space.
3.Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews:A retrospective cohort study
Eun-Hack ANDREW CHOI ; Dasomi KIM ; Liu JING ; Hyung-Seog YU ; Sung-Hwan CHOI ; Jung-Yul CHA
The Korean Journal of Orthodontics 2025;55(3):167-175
Objective:
To assess the success rate and proximity of miniscrews to the root using surgical guides produced by integrating data obtained from conebeam computed tomography and intraoral scanned models.
Methods:
This retrospective study involved 113 patients (224 miniscrews) who underwent miniscrew placement as part of their orthodontic treatment. Two operators placed miniscrews between the buccal alveolar bone of each patient and assessed initial stability by measuring the Periotest value (PTV) and insertion torque (IT). Patients were divided into two groups based on the miniscrew insertion method: manual group (MG) and surgical guide group (SG). Root proximity was assessed using periapical radiography, and miniscrews that remained in place for over 6 months were considered successful.
Results:
There was a statistically significant difference in the Kaplan–Meier survival curves between the groups (P < 0.05). The success rates of the miniscrews were 79.1% and 90.5% for the MG and SG, respectively (P < 0.05). The root contact rate also differed significantly between the groups (MG, 17.5%; SG, 0.1%; P < 0.001). However, the PTV and IT did not show significant differences between the groups.
Conclusions
Proximity to the root and utilization of surgical guides have the most direct impact on the success rate of miniscrews. Root proximity can be effectively reduced using surgical guides. Therefore, the use of a miniscrew surgical guide is recommended to increase the success rate of miniscrews as stable anchorage devices, particularly in cases with narrow interradicular space.
4.Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews:A retrospective cohort study
Eun-Hack ANDREW CHOI ; Dasomi KIM ; Liu JING ; Hyung-Seog YU ; Sung-Hwan CHOI ; Jung-Yul CHA
The Korean Journal of Orthodontics 2025;55(3):167-175
Objective:
To assess the success rate and proximity of miniscrews to the root using surgical guides produced by integrating data obtained from conebeam computed tomography and intraoral scanned models.
Methods:
This retrospective study involved 113 patients (224 miniscrews) who underwent miniscrew placement as part of their orthodontic treatment. Two operators placed miniscrews between the buccal alveolar bone of each patient and assessed initial stability by measuring the Periotest value (PTV) and insertion torque (IT). Patients were divided into two groups based on the miniscrew insertion method: manual group (MG) and surgical guide group (SG). Root proximity was assessed using periapical radiography, and miniscrews that remained in place for over 6 months were considered successful.
Results:
There was a statistically significant difference in the Kaplan–Meier survival curves between the groups (P < 0.05). The success rates of the miniscrews were 79.1% and 90.5% for the MG and SG, respectively (P < 0.05). The root contact rate also differed significantly between the groups (MG, 17.5%; SG, 0.1%; P < 0.001). However, the PTV and IT did not show significant differences between the groups.
Conclusions
Proximity to the root and utilization of surgical guides have the most direct impact on the success rate of miniscrews. Root proximity can be effectively reduced using surgical guides. Therefore, the use of a miniscrew surgical guide is recommended to increase the success rate of miniscrews as stable anchorage devices, particularly in cases with narrow interradicular space.
5.Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews:A retrospective cohort study
Eun-Hack ANDREW CHOI ; Dasomi KIM ; Liu JING ; Hyung-Seog YU ; Sung-Hwan CHOI ; Jung-Yul CHA
The Korean Journal of Orthodontics 2025;55(3):167-175
Objective:
To assess the success rate and proximity of miniscrews to the root using surgical guides produced by integrating data obtained from conebeam computed tomography and intraoral scanned models.
Methods:
This retrospective study involved 113 patients (224 miniscrews) who underwent miniscrew placement as part of their orthodontic treatment. Two operators placed miniscrews between the buccal alveolar bone of each patient and assessed initial stability by measuring the Periotest value (PTV) and insertion torque (IT). Patients were divided into two groups based on the miniscrew insertion method: manual group (MG) and surgical guide group (SG). Root proximity was assessed using periapical radiography, and miniscrews that remained in place for over 6 months were considered successful.
Results:
There was a statistically significant difference in the Kaplan–Meier survival curves between the groups (P < 0.05). The success rates of the miniscrews were 79.1% and 90.5% for the MG and SG, respectively (P < 0.05). The root contact rate also differed significantly between the groups (MG, 17.5%; SG, 0.1%; P < 0.001). However, the PTV and IT did not show significant differences between the groups.
Conclusions
Proximity to the root and utilization of surgical guides have the most direct impact on the success rate of miniscrews. Root proximity can be effectively reduced using surgical guides. Therefore, the use of a miniscrew surgical guide is recommended to increase the success rate of miniscrews as stable anchorage devices, particularly in cases with narrow interradicular space.
6.Validation of three-dimensional digital model superimpositions based on palatal structures in patients with maximum anterior tooth retraction following premolar extraction
Jing LIU ; Kyong-Min KOH ; Sung-Hwan CHOI ; Ji-Hoi KIM ; Jung-Yul CHA
The Korean Journal of Orthodontics 2022;52(4):258-267
Objective:
This study aimed to evaluate the superimposition accuracy of digital modes for measuring tooth movement in patients requiring anterior retraction after premolar extraction based on the proposed reference regions.
Methods:
Forty patients treated with bilateral maxillary first premolar extraction were divided into two groups: moderate retraction (< 7.0 mm) and maximum retraction (≥ 7.0 mm). Central incisor displacement was measured using cephalometric superimpositions and three-dimensional (3D) digital superimpositions with the 3rd or 4th ruga as the reference point. The Wilcoxon signed-rank test and linear regression analyses were performed to test the significance of the differences and relationships between the two measurement techniques.
Results:
In the moderate retraction group, the central incisor anteroposterior displacement values did not differ significantly between 3D digital and cephalometric superimpositions. However, in the maximum-retraction group, significant differences were observed between the anteroposterior displacement evaluated by the 3rd ruga superimposition and cephalometric methods (p < 0.05).
Conclusions
This study demonstrated that 3D digital superimpositions were clinically as reliable as cephalometric superimpositions in assessing tooth movements in patients requiring moderate retraction. However, the reference point should be carefully examined in patients who require maximum retraction.
7.Applying the OMOP Common Data Model to Facilitate Benefit-Risk Assessments of Medicinal Products Using Real-World Data from Singapore and South Korea
Hui Xing TAN ; Desmond Chun Hwee TEO ; Dongyun LEE ; Chungsoo KIM ; Jing Wei NEO ; Cynthia SUNG ; Haroun CHAHED ; Pei San ANG ; Doreen Su Yin TAN ; Rae Woong PARK ; Sreemanee Raaj DORAJOO
Healthcare Informatics Research 2022;28(2):112-122
Objectives:
The aim of this study was to characterize the benefits of converting Electronic Medical Records (EMRs) to a common data model (CDM) and to assess the potential of CDM-converted data to rapidly generate insights for benefit-risk assessments in post-market regulatory evaluation and decisions.
Methods:
EMRs from January 2013 to December 2016 were mapped onto the Observational Medical Outcomes Partnership-CDM (OMOP-CDM) schema. Vocabulary mappings were applied to convert source data values into OMOP-CDM-endorsed terminologies. Existing analytic codes used in a prior OMOP-CDM drug utilization study were modified to conduct an illustrative analysis of oral anticoagulants used for atrial fibrillation in Singapore and South Korea, resembling a typical benefit-risk assessment. A novel visualization is proposed to represent the comparative effectiveness, safety and utilization of the drugs.
Results:
Over 90% of records were mapped onto the OMOP-CDM. The CDM data structures and analytic code templates simplified the querying of data for the analysis. In total, 2,419 patients from Singapore and South Korea fulfilled the study criteria, the majority of whom were warfarin users. After 3 months of follow-up, differences in cumulative incidence of bleeding and thromboembolic events were observable via the proposed visualization, surfacing insights as to the agent of preference in a given clinical setting, which may meaningfully inform regulatory decision-making.
Conclusions
While the structure of the OMOP-CDM and its accessory tools facilitate real-world data analysis, extending them to fulfil regulatory analytic purposes in the post-market setting, such as benefit-risk assessments, may require layering on additional analytic tools and visualization techniques.
8.Perspectives of East Asian patients and physicians on complementary and alternative medicine use for inflammatory bowel disease: results of a cross-sectional, multinational study
Eun Soo KIM ; Chung Hyun TAE ; Sung-Ae JUNG ; Dong Il PARK ; Jong Pil IM ; Chang Soo EUN ; Hyuk YOON ; Byung Ik JANG ; Haruhiko OGATA ; Kayoko FUKUHARA ; Fumihito HIRAI ; Kazuo OHTSUKA ; Jing LIU ; Qian CAO ;
Intestinal Research 2022;20(2):192-202
Background/Aims:
Complementary and alternative medicine (CAM) is prevalent in East Asia. However, information on CAM in East Asian patients with inflammatory bowel disease (IBD) is scarce. We aimed to profile the prevalence and pattern of CAM use among East Asian IBD patients and to identify factors associated with CAM use. We also compared physicians’ perspectives on CAM.
Methods:
Patients with IBD from China, Japan, and South Korea were invited to complete questionnaires on CAM use. Patient demographic and clinical data were collected. Logistic regression analysis was applied for predictors of CAM use. Physicians from each country were asked about their opinion on CAM services or products.
Results:
Overall, 905 patients with IBD participated in this study (China 232, Japan 255, and South Korea 418). Approximately 8.6% of patients with IBD used CAM services for their disease, while 29.7% of patients sought at least 1 kind of CAM product. Current active disease and Chinese or South Korean nationality over Japanese were independent predictors of CAM use. Chinese doctors were more likely to consider CAM helpful for patients with IBD than were Japanese and South Korean doctors.
Conclusions
In 8.6% and 29.7% of East Asian patients with IBD used CAM services and products, respectively, which does not differ from the prevalence in their Western counterparts. There is a significant gap regarding CAM usage among different Asian countries, not only from the patients’ perspective but also from the physicians’ point of view.
9.Neuronal Signatures of Negative and Positive Schemas towards the Self and Others in Patients with Early Stage Schizophrenia
Jie SHEN ; Guangfan SHEN ; Woo-Sung KIM ; Uyanga TSOGT ; Congcong LIU ; Jing SUI ; Young-Chul CHUNG
Psychiatry Investigation 2021;18(4):284-294
Objective:
The present study investigated the functional neuroanatomy underlying negative and positive schemas towards the self and others in patients with early stage schizophrenia spectrum disorders (SSDs) using a task-based fMRI procedure.
Methods:
This study included 50 patients with SSDs and 52 controls. The schema-evoking task consisted of four active conditions and neutral condition. Differences in brain activation were compared between the two groups. Correlation analysis was performed between task-related activation and psychopathology.
Results:
The SSD patients exhibited higher activity of the left middle and inferior frontal gyri under the negative-others minus neutral contrast as well as greater activation of the left superior and middle frontal gyri and right medial superior frontal gyrus under the positive- self minus neutral and positive-others minus neutral contrasts. Under the positive-others minus neutral contrast, negative correlation was observed between activity of the right inferior parietal gyrus and right angular and total score of the Positive and Negative Syndrome Scale (PANSS), whereas positive correlation between activity of the left middle cingulate gyrus and left/right precuneus and positive-others score of the Brief Core Schema Scales (BCSS).
Conclusion
The present findings suggest that the frontal brain regions of SSD patients are more sensitive to negative and positive schemas towards the self and/or others compared to those of controls.
10.Neuronal Signatures of Negative and Positive Schemas towards the Self and Others in Patients with Early Stage Schizophrenia
Jie SHEN ; Guangfan SHEN ; Woo-Sung KIM ; Uyanga TSOGT ; Congcong LIU ; Jing SUI ; Young-Chul CHUNG
Psychiatry Investigation 2021;18(4):284-294
Objective:
The present study investigated the functional neuroanatomy underlying negative and positive schemas towards the self and others in patients with early stage schizophrenia spectrum disorders (SSDs) using a task-based fMRI procedure.
Methods:
This study included 50 patients with SSDs and 52 controls. The schema-evoking task consisted of four active conditions and neutral condition. Differences in brain activation were compared between the two groups. Correlation analysis was performed between task-related activation and psychopathology.
Results:
The SSD patients exhibited higher activity of the left middle and inferior frontal gyri under the negative-others minus neutral contrast as well as greater activation of the left superior and middle frontal gyri and right medial superior frontal gyrus under the positive- self minus neutral and positive-others minus neutral contrasts. Under the positive-others minus neutral contrast, negative correlation was observed between activity of the right inferior parietal gyrus and right angular and total score of the Positive and Negative Syndrome Scale (PANSS), whereas positive correlation between activity of the left middle cingulate gyrus and left/right precuneus and positive-others score of the Brief Core Schema Scales (BCSS).
Conclusion
The present findings suggest that the frontal brain regions of SSD patients are more sensitive to negative and positive schemas towards the self and/or others compared to those of controls.

Result Analysis
Print
Save
E-mail