1.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
2.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
3.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
4.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Therapeutic effect and mechanism of hordenine on ovalbumin-induced allergic rhinitis in rats
Junyan LI ; Tao LIU ; Fang SUN ; Jiahui HUANG ; Shuzhen MAO ; Jing YAO
Journal of China Pharmaceutical University 2025;56(1):80-90
To investigate the therapeutic effect and related mechanisms of hordenine on ovalbumin (OVA)-induced allergic rhinitis (AR) in rats, HE and AB-PAS staining were used to detect the improvement of pathological damage to the nasal mucosa induced by hordenine. ELISA was employed to detect the effect of hordenine on OVA-sIgE in serum and IL-4 in the nasal mucosa supernatant of rats. IHC and Western blot experiments were undertaken to examine the effect of hordenine on Th1/Th2 cell balance. Bioinformatics analysis was performed to predict pathways, which were verified by in vivo and in vitro experiments. The experimental results showed that hordenine could alleviate the behavioral manifestations of OVA-induced AR rats, alleviate nasal mucosal pathological damage caused by AR, and reduce the secretion of OVA-sIgE and IL-4. In addition, hordenine could regulate the Th1/Th2 balance. Bioinformatics analysis results showed that the potential pathway of action of hordenine on AR was the phosphoinositide 3 kinase (PI3K)/protein kinase B (Akt) signaling pathway. The in vivo experimental results showed that the expression of PI3K and p-Akt proteins in the nasal mucosa of the model group rats was significantly increased (P < 0.01), and that the protein expression level was significantly decreased after the administration of hordenine, which was also confirmed by an in vitro experiment. This study suggests that hordenine may regulate Th1/Th2 cell balance through the PI3K/Akt signaling pathway, thereby exerting an alleviating effect on OVA-induced AR.
7.Impact of rigid container material type and loading volume on the sterilization of thoracoscopic instruments
Xue'e FANG ; Yanjun MAO ; Qiuping ZHU ; Yanni CAI ; Jing SHU ; Guifen ZHANG ; Yichun JIN ; Minye TANG ; Ying TAO ; Huiting HU
Shanghai Journal of Preventive Medicine 2025;37(8):697-699
ObjectiveTo explore the impacts of material type and loading volume of rigid containers on the hydrogen peroxide low temperature plasma sterilization of thoracoscopic instruments, to identify the best rigid containers and loading volume of thoracoscopic instruments. MethodsThoracoscopic instruments sterilized by STERRAD® 100NX hydrogen peroxide low temperature plasma in Shanghai Pulmonary Hospital affiliated to Tongji University from August to September 2024 were selected as the research items. According to the material of rigid containers, the instruments were divided into polyethylene case group (A), stainless steel case group (B) and silicone resin case group (C). In terms of the loading volume, the rigid containers were divided into (loading capacity <80%) groups of 8, 10 and 12 instruments. The results of physical monitoring, the first type of chemical indicator card monitoring, and the five types of card luminal chemical process challenge device (PCD) monitoring of the 9 groups of A8, A10, A12, B8, B10, B12, C8, C10 and C12 were compared and evaluated. ResultsCompared to A8, A10 A12, C8, C10 or C12 groups, the thoracoscope instruments in the stainless steel containers in B8, B10 or B12 group had higher hydrogen peroxide concentrations and shorter elapsed time in the pressure check phases 1 and phases 2, with the differences statistically significant (P<0.05), followed by the silicone resin case group and the polyethylene case group. The nine groups of physical parameter monitoring, the first type of chemical indicator monitoring, and the five types of chemical PCD monitoring for lumen sterilization achieved 100% qualification rates, and there were no significant differences in the qualified rates of sterilization among the 9 groups (P>0.05). ConclusionWhen using hydrogen peroxide low temperature plasma to sterilize thoracoscopic instruments, it is recommended to use stainless steel or silicone resin rigid containers with a controlled loading capacity (≤12) to ensure optimal sterilization quality.
8.Application of Pentacam TNP in calculating the intraocular lens power after corneal refractive surgery
Xinyi ZANG ; Shilan MAO ; Jin XIE ; Xiaomin LIU ; Dewei LI ; Jing YUAN ; Yunhai DAI
International Eye Science 2024;24(4):646-650
AIM: To assess the accuracy of predicting intraocular lens(IOL)power after myopic refractive surgery using the Pentacam system's true net power(TNP)in the 3 mm zone combined with the SRK/T formula [i.e. TNP 3 mm(SRK/T)].METHODS: Retrospective study. This study enrolled 35 cases(50 eyes)of patients undergoing cataract surgery after laser assisted in situ keratomileusis(LASIK)or photorefractive keratectomy(PRK)from July 2019 to December 2021. Preoperatively, IOL power of 50 eyes, 34 eyes and 41 eyes was calculated by TNP 3 mm(SRK/T), Barrett True-K and Olsen 2 formulas, respectively, with at least 2 formulas used to calculate IOL power for each patient. The actual diopter was recorded 3 mo postoperatively. Prediction errors(PE)of IOL power were compared among the three calculation methods, and the proportion of eyes with PE within ±0.5 D and ±1.0 D was analyzed.RESULTS: The PE at 3 mo postoperatively for TNP 3 mm(SRK/T), Barrett True-K, and Olsen 2 was -0.02±0.63, -0.54±0.80, and 0.25±0.80 D, respectively(P<0.001). The proportions of PE within ±0.5 D were 66%(33/50), 44%(15/34)and 37%(15/41), respectively(P<0.05); the proportions of PE within ±1.0 D were 88%(44/50), 71%(24/34)and 80%(33/41), respectively(P>0.05).CONCLUSION: The Pentacam TNP 3 mm(SRK/T)method is simple to operate and provides accurate calculation of IOL power after corneal refractive surgery.
9.Latest research progress in airway stenosis after lung transplantation
Yujie ZUO ; Menggen LIU ; Jiaxin WAN ; Yuxuan CHEN ; Wenlong HU ; Junjie ZHANG ; Yuyang MAO ; Jing CHEN ; Ailing ZHONG ; Lingzhi SHI ; Bo WU ; Chunrong JU ; Dong TIAN
Organ Transplantation 2024;15(3):474-478
With the optimization of surgical technologies and postoperative management regimens, the number of lung transplantation has been significantly increased, which has become an important treatment for patients with end-stage lung disease. However, due to the impact of comprehensive factors, such as bronchial ischemia and immunosuppression, the incidence of airway stenosis after lung transplantation is relatively high, which severely affects postoperative survival and quality of life of lung transplant recipients. In recent years, with the improvement of perioperative management, organ preservation and surgical technologies, the incidence of airway stenosis after lung transplantation has been declined, but it remains at a high level. Early diagnosis and timely intervention play a significant role in enhancing clinical prognosis of patients with airway stenosis. In this article, the general conditions, diagnosis, treatment and prevention of airway stenosis after lung transplantation were reviewed, aiming to provide reference for comprehensive management of airway stenosis after lung transplantation and improving clinical prognosis of lung transplant recipients.
10.Soft and hard tissue changes of hyperdivergent class Ⅱ patients before and after orthodontic extraction treatment
Bochun MAO ; Yajing TIAN ; Xuedong WANG ; Jing LI ; Yanheng ZHOU
Journal of Peking University(Health Sciences) 2024;56(1):111-119
Objective:To investigate the hard and soft tissue changing trend and contributing factors of skeletal class Ⅱ hyperdivergent patients before and after orthodontic camouflage treatment by analyzing the cephalogram and the three dimensional(3D)facial scan data.Methods:Eighteen skeletal class Ⅱhyperdivergent adult female patients who finished camouflage orthodontic treatment were selected.Skele-tal and dental measurements were carried out with the cephalometric analysis before and after the treat-ment.3D facial data before and after orthodontic treatment were acquired and the anatomical landmarks were set after the repositioning and superimposition process.Hard tissue measurement included 17 mea-surement indicators(sella-nasion-subspinale angle,sella-nasion-supramental angle,subspinale-nasion-supramental angle,facial angle,angle of convexity,Frankfort horizontal plane-mandibular plane angle(FH-MP),Y axis angle,sella-nasion plane-mandibular plane angle(MP-SN),pogonion-nasion-supra-mental distance,upper incisor-nasion-subspinale distance,upper incisor to sella-nasion,lower incisor-nasion-supramental distance,lower incisor-nasion-supramental angle,upper incisor to lower incisor,up-per incisor to sella-nasion,lower incisor-mandibular plane angle,and Z angle),and the changes before and after treatment were measured for 11 of them.Twenty soft tissue landmarks(left/right cheekbone,left/right chelion,left/right crista philtra,soft tissue gnathion,left/right gonion,glabella,labrale infe-rius,labrale superius,soft tissue menton,left/right mid-mandibular border,soft tissue pogonion,stomi-on superius,sublabial,subnasale,and supralabial)and 9 soft tissue indicators(lower lip height,facial convexity,lower vermilion height,mandibular contour,nasolabial angle,philtral length,philtral width,upper lip height,and upper vermilion height)were measured and recorded for treatment changes.Linear-regression analysis and correlation analysis were carried out for analyzing the relationship between hard and soft tissue changes before and after the treatment.Results:Significant differences were noticed for 18 out of the 20 cephalometric measurements and facial measurements before and after the treatment(P<0.05),which mainly represented the sagittal retraction of lip area after the treatment.Significant vertical displacements were revealed for soft tissue menton after treatment[(1.88±2.61)mm,P<0.05].Significant sagittal displacements were revealed for left/right cheilion[(-2.95±1.9)mm,(-2.90±1.92)mm],labrale inferius[(-4.94±1.95)mm],labrale superius[(-3.25±1.44)mm],sublabial[(-3.10±3.5)mm],and subnasale[(-1.23±1.06)mm]after treatment(P<0.05).An average of 4.10°±2.57° increasement was noticed for Z angle after treatment.High correla-tion(r>0.7)was noticed for the displacement of menton after treatment with FH-MP,with the rate of-0.183:1,and MP-SN,with the rate of-0.157:1.Moderate correlations(0.7≥r>0.4)were no-ticed for the other measurements with correlations(P<0.05).Conclusion:A certain extent of facial improvements could be achieved with orthodontic camouflage treatment for skeletal class Ⅱ hyperdiver-gent patients,which were mostly represented by the improvement of sagittal relationship of nose,lips,and chin.Certain correlations were noticed for the hard and soft tissue changes.

Result Analysis
Print
Save
E-mail