1.Bioequivalence study of pyrazinamide tablets in Chinese healthy subjects
Li-Bing YE ; Chong YAO ; Ying-Rong CHEN ; Lu-Yuan TONG ; Tao YANG ; Xiao LU ; Min XU ; Qiu-Yue JIN ; Shui-Xin YANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2236-2240
		                        		
		                        			
		                        			Objective To evaluate the bioequivalence and safety of two pyrazinamide tablets in healthy Chinese subjects.Methods An open,randomized,single-dose,two-sequence,two-cycle,double-cross trial design was used.All 48 healthy subjects(24 in fasting and 24 in fed trial)were randomized to receive a single oral dose of a 0.5 g pyrazinamide tablet(test or reference)per cycle.The plasma concentration of the drug was determined by liquid chromatography coupled to tandem mass spectrometry method.The pharmacokinetic parameters were calculated by WinNonlin v8.2,and the bioequivalence was evaluated by SAS 9.4.Results In the fasting group,the Cmax of the test and reference preparation of pyrazinamide tablets were(13.28±2.82)and(12.88±4.49)μg·mL-1,the AUC0-t were(139.17±26.58)and(138.63±28.92)h·μg·mL-1,the AUC0-∞ were(148.96±33.65)and(148.71±36.97)h·μg·mL-1 respectively.In the fed group,the Cmax of the test and reference preparation of pyrazinamide tablets were(11.89±1.96)and(11.99±1.92)μg·mL-1,the AUC0-t were(138.22±37.21)and(141.68±25.80)h·μg·mL-1,the AUC0-∞ were(152.20±32.41)and(151.04±28.05)h·μg·mL-,respectively.The 90%confidence intervals of Cmax,AUC0-t and AUC0-∞ geometric mean ratios of the test and reference preparation were all within 80.00%to 125.00%.The incidence of adverse events was 16.70%for both the test and reference preparation in the fasting group and 8.30%for both the test and reference preparation in the fed group,all of which were mild in severity.Conclusion The test and reference preparation of pyrazinamide tablets were bioequivalent,safe and well tolerated in healthy Chinese subjects under fasting and fed conditions.
		                        		
		                        		
		                        		
		                        	
2.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
		                        		
		                        			
		                        			Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
		                        		
		                        		
		                        		
		                        			Pregnancy
		                        			;
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Glycated Hemoglobin
		                        			;
		                        		
		                        			Cohort Studies
		                        			;
		                        		
		                        			Diabetes Mellitus/diagnosis*
		                        			;
		                        		
		                        			Sensitivity and Specificity
		                        			;
		                        		
		                        			ROC Curve
		                        			
		                        		
		                        	
3.Clinical application of serum Golgi protein 73 in patients with chronic liver diseases.
Yan Na LIU ; Ming Jie YAO ; Su Jun ZHENG ; Xiang Mei CHEN ; Xiang Yi LIU ; Peng HU ; Qi Shui OU ; Xiao Guang DOU ; Hong Song CHEN ; Zhong Ping DUAN ; Jin Lin HOU ; Yue Min NAN ; Zhi Liang GAO ; Xiao Yuan XU ; Hui ZHUANG ; Feng Min LU
Chinese Journal of Hepatology 2022;30(1):4-8
		                        		
		                        			
		                        			Golgi protein 73 (GP73) is a transmembrane protein on the Golgi apparatus and can be cut and released into the blood. In recent years, an increasing number of clinical studies have shown that the elevated serum GP73 level is closely related to liver diseases. And thus GP73 is expected to be used as a new serum marker for assessing progress of chronic liver diseases. Herein, the clinical application of serum GP73 in chronic hepatitis, liver fibrosis, liver cirrhosis and hepatocellular carcinoma with different etiologies was reviewed based on available literatures; and a research outlook in this field is made.
		                        		
		                        		
		                        		
		                        			Biomarkers
		                        			;
		                        		
		                        			Carcinoma, Hepatocellular
		                        			;
		                        		
		                        			Golgi Apparatus
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Liver Cirrhosis
		                        			;
		                        		
		                        			Liver Neoplasms
		                        			
		                        		
		                        	
4.Comparison between charged aerosol detector and evaporative light scattering detector for analysis of sugar in Zhusheyong Yiqi Fumai and study on accuracy of methods.
Ying WANG ; Yuan-Xi LIU ; Hong-Shui YUE ; Xu WEI-YI ; Jian-Ming CAO ; Hong-Yu JIN ; Ma SHUANG-CHENG
China Journal of Chinese Materia Medica 2020;45(22):5511-5517
		                        		
		                        			
		                        			Evaporative light scattering detector(ELSD) and charged aerosol detector(CAD) methods were established in this study for the content determination of four kinds of sugars in Zhusheyong Yiqi Fumai(YQFM), and the factors affecting the accuracy of CAD methods were discussed. HPLC-ELSD chromatographic separation was performed on a Shodex Asahipak NH2 P-50 column with acetonitrile-water(75∶25)as the mobile phase, with a flow rate of 0.8 mL·min~(-1), drift tube temperature of 80 ℃. The analysis by HPLC-CAD was performed on the same column with acetonitrile-water as mobile phase for gradient elution, with a flow rate of 0.8 mL·min~(-1), a neb temperature of 45 ℃, and power function(PF) of 1.3. The samples of YQFM were detected by ELSD and CAD respectively. It was found that YQFM was composed of fructose, glucose, sucrose and maltose. The linear relationship of the two methods was good, and the recoveries, reproducibility and stability of these four kinds of sugars measured by the two methods satisfied the requirements of methodology. Both CAD and ELSD detectors were accurate and reliable in detecting saccharides components in YQFM. In addition, it was revealed in this study for the first time that the PF parameter of CAD had an important influence on the accuracy of sugar determination and acted as the key parameter of CAD method. It was also found that for CAD, a non-linear detector, there was no significant difference between the results of linear regression and logarithmic regression.
		                        		
		                        		
		                        		
		                        			Aerosols
		                        			;
		                        		
		                        			Carbohydrates
		                        			;
		                        		
		                        			Chromatography, High Pressure Liquid
		                        			;
		                        		
		                        			Light
		                        			;
		                        		
		                        			Reproducibility of Results
		                        			;
		                        		
		                        			Scattering, Radiation
		                        			;
		                        		
		                        			Sugars
		                        			
		                        		
		                        	
5.Effect of bevacizumab in treatment of children with optic pathway glioma.
Wan-Shui WU ; Jing-Jing LIU ; Yan-Ling SUN ; Shu-Xu DU ; Chun-De LI ; Miao LI ; Si-Qi REN ; Jin ZHANG ; Xiao-Jun GONG ; Li-Ming SUN
Chinese Journal of Contemporary Pediatrics 2019;21(12):1193-1197
		                        		
		                        			OBJECTIVE:
		                        			To investigate the effect of bevacizumab in the treatment of children with optic pathway glioma (OPG).
		                        		
		                        			METHODS:
		                        			A retrospective analysis was performed for the clinical data of 30 children with OPG who underwent chemotherapy. According to whether bevacizumab was used, they were divided into conventional chemotherapy (carboplatin, vincristine and etoposide) group with 12 children and combined chemotherapy (bevacizumab, carboplatin, vincristine and etoposide) group with 18 children. The children were followed up to 6 months after chemotherapy, and the two groups were compared in terms of visual acuity and tumor size before and after chemotherapy and adverse reactions during chemotherapy.
		                        		
		                        			RESULTS:
		                        			The combined chemotherapy group had a significantly higher proportion of children achieving tumor regression than the conventional chemotherapy group (P<0.05), while there were no significant differences between the two groups in the proportion of children with improved visual acuity or adverse reactions (P>0.05). No chemotherapy-related death was observed in either group.
		                        		
		                        			CONCLUSIONS
		                        			Bevacizumab combined with conventional chemotherapy can effectively reduce tumor size. Compared with conventional chemotherapy, such combination does not increase adverse reactions and can thus become a new direction for the treatment of OPG in children.
		                        		
		                        		
		                        		
		                        			Antineoplastic Combined Chemotherapy Protocols
		                        			;
		                        		
		                        			Bevacizumab
		                        			;
		                        		
		                        			Carboplatin
		                        			;
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Optic Nerve Glioma
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Vincristine
		                        			
		                        		
		                        	
6.Identification of Tiletamine, Zolazepam and Their Metabolites in Drug Facilitated Sexual Assault by GC-QTOF-MS.
Si Yang HE ; Fei Jun GONG ; Ru LIAN ; Zhen Hai SHENG ; Jin Lun XU ; Wen Juan SUN ; Shui Qing ZHENG
Journal of Forensic Medicine 2019;35(5):581-585
		                        		
		                        			
		                        			Objective To identify tiletamine, zolazepam and their metabolites in samples from drug facilitated sexual assault by gas chromatography-quadrupole time of flight mass spectrometry (GC-QTOF-MS). Methods Urine samples of victims were collected, and detected by GC-QTOF-MS after liquid-liquid extraction and concentration. The molecular formula of fragments ions was identified by determination of accurate mass numbers, to detect related substances. Results Tiletamine, zolazepam, three metabolites of tiletamine and two metabolites of zolazepam were identified in urine samples from actual cases. Conclusion GC-QTOF-MS provides abundant and accurate information of fragment ions mass numbers, which can be used for qualitative identification of tiletamine, zolazepam and their metabolites in drug facilitated sexual assault.
		                        		
		                        		
		                        		
		                        			Chromatography, High Pressure Liquid/methods*
		                        			;
		                        		
		                        			Forensic Toxicology/methods*
		                        			;
		                        		
		                        			Gas Chromatography-Mass Spectrometry/methods*
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Sex Offenses
		                        			;
		                        		
		                        			Tandem Mass Spectrometry/methods*
		                        			;
		                        		
		                        			Tiletamine/blood*
		                        			;
		                        		
		                        			Zolazepam/blood*
		                        			
		                        		
		                        	
7.Stems and leaves of Aconitum carmichaelii Debx. as potential herbal resources for treating rheumatoid arthritis: Chemical analysis, toxicity and activity evaluation.
Ya-Nan HE ; Shui-Ping OU ; Xi XIONG ; Yuan PAN ; Jin PEI ; Run-Chun XU ; Fu-Neng GENG ; Li HAN ; Ding-Kun ZHANG ; Ming YANG
Chinese Journal of Natural Medicines (English Ed.) 2018;16(9):644-652
		                        		
		                        			
		                        			According to folk usage of Aconitum carmichaelii Debx., the present study was designed to determine the feasibility of the stems and leaves of Aconitum carmichaelii Debx. as a new medicinal resource. Fourteen alkaloids in mother roots, fibrous roots, stems, and leaves of Aconitum carmichaelii Debx. were measured by HPLC-MS/MS. And multivariate analysis methods, such as clustering analysis and principal component analysis, were applied to analyze the difference among various parts. In addition, the acute toxicity, analgesia, and anti-inflammatory tests were carried out. The results suggested that the contents of alkaloids in mother roots and fibrous roots were approximate, but those of leaves and stems were different from mother roots and fibrous roots. The results of the acute toxicity testing demonstrated the toxicity of fibrous root was strongest, and mother roots were slightly less toxic than fibrous roots. The stems and leaves were far less toxic than mother and fibrous roots. In addition, the analgesia and inflammatory tests showed the effects of the various tissues had no difference each other. These results provided a basis for developing new complementary and alternative treatments for rheumatoid arthritis patients. Simultaneously, the approach may also turn wastes into treasure and promote the development of circular economy.
		                        		
		                        		
		                        		
		                        			Aconitum
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			Alkaloids
		                        			;
		                        		
		                        			administration & dosage
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			toxicity
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Anti-Inflammatory Agents
		                        			;
		                        		
		                        			administration & dosage
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			toxicity
		                        			;
		                        		
		                        			Arthritis, Rheumatoid
		                        			;
		                        		
		                        			drug therapy
		                        			;
		                        		
		                        			Chromatography, High Pressure Liquid
		                        			;
		                        		
		                        			Drug Evaluation, Preclinical
		                        			;
		                        		
		                        			Drugs, Chinese Herbal
		                        			;
		                        		
		                        			administration & dosage
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			toxicity
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Plant Leaves
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			Plant Roots
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			Plant Stems
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			Tandem Mass Spectrometry
		                        			
		                        		
		                        	
8.The development of an evaluation index system on health information on the internet using Delphi method
Yu-Sui ZHAO ; Yan XU ; Qing-Qing WU ; Shui-Yang XU ; Jin-Hang XU
Journal of Preventive Medicine 2018;30(2):121-124
		                        		
		                        			
		                        			Objective To develop an evaluation index system on health information on the internet using Delphi method. Methods The index system on health information on the internet was drown up and then two rounds of 11 experts' questionnaire consultation were conducted using Delphi method to determine the index system. Results Of 11 experts, the mean age was 48.55±6.79, and 91.67% of experts had high professional titles and had been working for average (23.64±10.10) years. The altive coefficient for the first and the second hound consultation was 91.67% and 100.00% respectively. The average coefficient of specialists authority was 0.75. After two round consultations, Kendalf's concordance coefficients were 0.39 (P<0.01) and 0.51 (P <0.01) , respectively. After two rounds of Delphi, the index system includes 3 from first-level indicators and 15 from secondary-level indicators. Conclusion Experts' representativeness, enthusiasm and professionalism brought to a consensus in developing an evaluation index system to be used in monitoring health information on the internet.
		                        		
		                        		
		                        		
		                        	
9.Effect of Reproducibility of Nano-liquid Chromatography-Mass Spectrometry on Analysis of Urinary Peptidomics
Yong WANG ; Li WU ; Ling Jin XU ; Ming Shui LI ; Ning LIU ; Liang JIANG
Chinese Journal of Analytical Chemistry 2017;45(10):1475-1481
		                        		
		                        			
		                        			As an extension of proteomics, peptidomics has been widely used in medical and biological researches. However, the effect of reproducibility of identification method on peptidomics is not yet clear. In this work, the urine sample of a healthy people was analyzed for seven times in parallel by nano-liquid chromatography-high-resolution tandem mass spectrometry. To illustrate the variability and stability among these experiments, the number of spectra, the utilization of total spectra, the number of identified peptides, the number of proteins, and the ionic strength and retention time of peptides were counted and compared. The average number of peptides was 208 and the standard deviation was 38. 7. After all of data were combined, 426 peptides belonging to 114 proteins were obtained, while only 109 peptides coming from 35 proteins were identified in each experiment, indicating that there were both an randomness and a relative stability for LC-MS analysis. Increasing the number of parallel experiments would expand the data set of peptidomics, but the rate of increase would decrease over 3 or more measurements. Compared with peptides, the results of peptidomics were more stable at protein level, indicating that proteins were more robustly peptidomics biomarker than the peptides.
		                        		
		                        		
		                        		
		                        	
10.Alterations of Whole Brain Networks Degree Centrality in Patients with Primary Insomnia after Acupuncture Therapy:A Voxel-based Resting-state fMRI Research
Xiaoyue XU ; Shui WANG ; Ru LU ; Xiaofen MA ; Guihua JIANG ; Shishun FU ; Wenfeng ZHAN ; Jin FANG
Journal of Sun Yat-sen University(Medical Sciences) 2017;38(2):296-300
		                        		
		                        			
		                        			[Objective]To investigate the value of degree centrality(DC),a novel resting-state fMRI parameter,in voxel-wise whole-brain functional networks analysis in primary insomnia(PI)after acupuncture therapy.[Methods]The resting state fMRI were performed in 29 PI patients and 22 age,education,and sex-matched normal healthy subjects. Analysis of DC map changes between the two patient groups and the control group were performed by two sample t test.(threshold at P<0.05).[Results]Compared with the control group,patients with PI showed significantly reduced DC value in middle temporal gyrus(MTG. R);hippocampus(HIP. B);parahippocampal gyrus(PHG. R);putamen(PUT. R);cuneus(CUN. L).[Conclusions]Changes of DC value occurred in some region of brain in the PI patient groups when compared with the control group. It was indicated that DC ,as a novel resting-state fMRI parameter in the voxel-wise whole-brain functional networks ,might be an appealing alternative approach for further study on pathologic and neuropsychological states of PI.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail