1.Study on Impedance of Implantable Cardiac Pacemaker in Unipolar/Bipolar Pacing Mode by in Vitro Experiment.
Ding DING ; Kai-Bin LIN ; Dong HUANG ; Xin-Wei GUO ; Yan-Peng WANG ; Shuai LI ; Jing-Bo LI ; Jin-Hai NIU
Chinese Journal of Medical Instrumentation 2022;46(3):237-241
The unipolar/bipolar pacing mode of pacemaker is related to its circuit impedance, which affects the battery life. In this study, the in vitro experiment scheme of pacemaker circuit impedance test was constructed. The human blood environment was simulated by NaCl solution, and the experimental environment temperature was controlled by water bath. The results of in vitro experiments showed that under the experimental conditions similar to clinical human parameters, the difference between the circuit impedance of bipolar mode and unipolar mode is 120~200 Ω. The results of the in vitro experiment confirmed that the circuit impedance of bipolar circuit was larger than that of unipolar mode, which was found in clinical practice. The results of this study have reference value to the optimization of pacing mode and the reduction of pacemaker power consumption.
Cardiac Pacing, Artificial/methods*
;
Electric Impedance
;
Humans
;
Pacemaker, Artificial
;
Prostheses and Implants
2.Result analysis of percutaneous core needle biopsy for bone tumors in upper limbs with pathological fracture.
Zhi-Ping DENG ; Hai-Tao ZHAO ; Yang SUN ; Tao JIN ; Yi DING ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2021;34(6):527-530
OBJECTIVE:
To analyze the results of percutaneous core needle biopsy for bone tumors in upper limbs with pathologic fracture and to find the possible factors that could impact the results.
METHODS:
The including criteria for this study was the patients who had received percutaneous core needle biopsy and definitive surgery, whose tumor was located at upper limb with pathologic fracture. From January 2015 to December 2019, seventy-seven patients were enrolled. There were 55 males and 22 females. The median age was 27 years old (range:5 to 88 years old). The tumor located at humerus in 67 cases, radius in 8 cases and ulna in 2 cases. If the pathologic diagnosis of core needle biopsy was the same with the definitive surgery, it was defined as "correct". If the pathologic diagnosis of biopsy for benign or malignant was right but the exact diagnostic name was not the same with definitive surgery, it was defined as "supportive". If the pathologic diagnosis of biopsy for benign or malignant was not correct, it was defined as "wrong". We retrospectively analyzed the accuracy and impact factors for core needle biopsy.
RESULTS:
The result was "correct" in 63 cases(81.8%), "supportive" in 14 cases(18.2%), and "wrong" in 0 cases. We analyzed the gender, age, location, fracture displacement, the destroyed type for bone tumor, soft tissue mass, fluid area in the tumor as the factors. The results showed the rate for "correct" was significantly higher when the tumor had soft tissue mass (
CONCLUSION
The accuracy of percutaneous core needle biopsy for upper limb bone tumor with pathologic is high and acceptable. The biopsy chosen the soft tissue mass area can increase the accuracy.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Biopsy, Large-Core Needle
;
Bone Neoplasms
;
Child
;
Child, Preschool
;
Female
;
Fractures, Spontaneous
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Soft Tissue Neoplasms
;
Upper Extremity
;
Young Adult
3.Regulation of Hypnotic Active Components of Cnidii Fructus on Melatonin Synthesis Rate-limiting Enzyme AANAT in Rats with PCPA-induced Insomnia
Jin-liang GUO ; Qi-ming ZHONG ; Hai-jie JI ; Qian YANG ; Mei-qing SONG ; Li-li JIA ; Li-guo TONG ; Yan-yan NIU ; Ma-li FENG
Chinese Journal of Experimental Traditional Medical Formulae 2021;27(14):47-52
Objective:To observe the effects of Cnidii Fructus hypnotic active components (CHC) on the behaviors of rats with p-chlorophenylalanine (PCPA)-induced insomnia and melatonin (MT) synthesis rate-limiting enzyme arylalkylamine
4.Clinical Characteristics of Autoimmune Disease with Dual Seropositive Antibodies of Leucine-rich Glioma Inactivated 1 and Contactin-associated Protein 2.
Li Ling DONG ; Hong Zhi GUAN ; Yan HUANG ; Hong Lin HAO ; Jing Wen NIU ; Qing LIU ; Qiang LU ; Dan XU ; Jun Yi ZHANG ; Li Xin ZHOU ; Li Ri JIN ; Hai Tao REN ; Yi Cheng ZHU ; Bin PENG ; Li Ying CUI ; Xiang Qin ZHOU
Acta Academiae Medicinae Sinicae 2019;41(3):344-350
Objective To explore the clinical characteristics of autoimmune disease with dual seropositive antibodies of leucine-rich glioma inactivated 1(LGI1)and contactin-associated protein 2(Caspr2).Methods The clinical data of seven patients with dual seropositive LGI1 and Caspr2 antibodies who were admitted to the Neurology Department of Peking Union Medical College Hospital from July 2014 to December 2017 were retrospectively analyzed.Results Central,peripheral and autonomic nervous systems were all involved in the seven cases;100%(7/7)presented with insomnia,myokymia,neuropahic pain and hyperhydrosis;71%(5/7)showed memory decline or psychiatric and behavioral symptoms;57%(4/7)had urinary hesitation or constipation;and 43%(3/7)had seizure.Electromyography showed 100%(6/6) of the patients had prolonged afterdischarges following normal M waves and/or abnormal spontaneous firing.Electroencephalography revealed slow waves or basic rhythm slowing in 71%(5/7)of patients.Electrocardiography showed sinus tachycardia,axis deviation,and prolonged QT intervals in 71%(5/7)of patients.One patient died from arrhythmia before immunotherapy.One died from pulmonary infection after immunotherapy.Improvement with immunotherapy was documented in the other five cases.No relapse was noted during the 1-2-year follow-up.Conclusions Autoimmune disease with dual seropositive antibodies of LGI1 and Caspr2 can diffusely affect the central,peripheral,and autonomic nervous systems.The possibility of this disease should be considered in patients with acute and subacute onset of neuropsychiatric symptoms,especially in patients with accompanying insomnia,myokymia,and hyperhydrosis.
Autoantibodies
;
blood
;
Autoimmune Diseases
;
immunology
;
Humans
;
Membrane Proteins
;
immunology
;
Nerve Tissue Proteins
;
immunology
;
Proteins
;
immunology
;
Retrospective Studies
5. Characterization analysis and overexpressed vector construction of the circular RNA hsa_circ_0082626 derived from the antiviral gene ZC 3HAV 1
Jin-hui PAN ; Wen-xia YAO ; Hai LIN ; Qiu-ling NIU ; Yuan-wei LUO ; Min LIANG ; Xin-ke ZHOU
Journal of Medical Postgraduates 2019;32(5):495-500
Objective Circular RNA is a research hotspot of non-coding RNAs. The purpose of this study was to investigate the basic characteristics and expression effect of the overexpression vectors of circular RNA hsa_circ_0082626 transcribed from antiviral gene
6.External Quality Analysis of Quality Indicators on Specimen Acceptability
Yuan-Yuan YE ; Wei WANG ; Hai-Jian ZHAO ; Feng-Feng KANG ; Wei-Xing LI ; Zhi-Ming LU ; Wei-Min ZOU ; Yu-Qi JIN ; Wen-Fang HUANG ; Bin XU ; Fa-Lin CHEN ; Qing-Tao WANG ; Hua NIU ; Bin-Guo MA ; Jian-Hong ZHAO ; Xiang-Yang ZHOU ; Zuo-Jun SHEN ; Wei-Ping ZHU ; Yue-Feng L(U) ; Liang-Jun LIU ; Lin ZHANG ; Li-Qiang WEI ; Xiao-Mei GUI ; Yan-Qiu HAN ; Jian XU ; Lian-Hua WEI ; Pu LIAO ; Xiang-Ren A ; Hua-Liang WANG ; Zhao-Xia ZHANG ; Hao-Yu WU ; Sheng-Miao FU ; Wen-Hua PU ; Lin PENG ; Zhi-Guo WANG
Journal of Modern Laboratory Medicine 2018;33(2):134-138,142
Objective To analyze the status of quality indicators(QI) on specimen acceptability and establish preliminary qual ity specification.Methods Web based External Quality Assessment system was used to collect data of laboratories partici pated in "Medical quality control indicators in clinical laboratory" from 2015 to 2017,including once in 2015 and 2017 and twice in 2016.Rate and sigma scales were used to evaluate incorrect sample type,incorrect sample container,incorrect fill level and anticoagulant sample clotted.The 25th percentile (P25) and 75th percentile (P75) of the distribution of each QI were employed to establish the high,medium and low specification.Results 5 346,7 593,5 950 and 6 874 laboratories sub mitted the survey results respectively.The P50 of biochemistry (except incorrect fill level),immunology and microbiology reach to 6σ.The P50 of clinical laboratory is 4 to 6σ except for incorrect sample container.There is no significant change of the continuous survey results.Based on results in 2017 to establish the quality specification,the P25 and P75 of the four QIs is 0 and 0.084 4 %,0 and 0.047 6 %,0 and 0.114 2 %,0 and 0.078 4 %,respectively.Conclusion According to the results of the survey,most laboratories had a faire performance in biochemistry,immunology and microbiology,and clinical laboratory needs to be strengthened.Laboratories should strengthen the laboratory information system construction to ensure the actual and reliable data collection,and make a long time monitoring to achieve a better quality.
7.Biomechanical Properties of Synthetic Mesh Reconstructed Glenohumeral Joint Capsule.
Tao JIN ; Wei-Feng LIU ; Hai-Rong XU ; Yuan LI ; Xiao-Hui NIU
Chinese Medical Journal 2017;130(14):1743-1744
8.Magnetic Resonance Imaging for the Assessment of Long Bone Tumors.
Tao JIN ; Zhi-Ping DENG ; Wei-Feng LIU ; Hai-Rong XU ; Yuan LI ; Xiao-Hui NIU
Chinese Medical Journal 2017;130(21):2547-2550
BACKGROUNDWide resection margins of osseous tumors are associated with a low incidence of local recurrence, making accurate measurement of the intraosseous extent of primary malignant long bone tumors is crucial. We compared the intraosseous tumor extent assessed by magnetic resonance imaging (MRI) with the gross specimen to evaluate the accuracy of MRI.
METHODSA total of 255 patients with primary malignant tumors in the long bones were included. Using MRI, we defined the length of tumor as the distance from the articular surface to the boundary between abnormal and normal marrow signal. The extent of the abnormal intraosseous signal was measured on unenhanced T1-weighted (T1WI) magnetic resonance images after chemotherapy. All gross surgical specimens were sectioned, and tumor extent was measured. Wilcoxon signed-rank test was used to test the differences between MRI and gross specimen findings. Spearman's correlation analysis was used to test the correlation between groups.
RESULTSMedian tumor length by gross specimen (112 mm; range, 45-300 mm) was longer than that by MRI (108 mm; range, 45-304 mm; Z = -6.916, P < 0.001). Of 255 images, tumor length was accurately represented on 27 T1WI magnetic resonance images, overestimated on 79 images, and underestimated on 149 images. The median difference between imaging and gross specimen measurements was 2.0 mm (range: 1.0-15.0 mm) for the 79 cases where tumor length was overestimated, and 5.0 mm (range: 1.0-18.0 mm) for the 149 cases where tumor length was underestimated. The Spearman correlation demonstrated a high correlation of tumor length on gross specimen with the tumor length on MRI (R = 0.99, P < 0.01).
CONCLUSIONSWe conclude that preoperative MRI could be a useful method in determining intramedullary malignant bone tumor boundaries and may serve as an accepted assessment method of long bone tumors before limb-sparing surgery.
9.Endoscope-assisted Transoral Approach for Parapharyngeal Space Tumor Resection.
Jian WANG ; Wu-Yi LI ; Da-Hai YANG ; Xiao-Feng JIN ; Yan-Yan NIU
Chinese Medical Journal 2017;130(18):2267-2268
10.Magnetic Resonance Imaging for the Assessment of Long Bone Tumors
Jin TAO ; Deng ZHI?PING ; Liu WEI?FENG ; Xu HAI?RONG ; Li YUAN ; Niu XIAO?HUI
Chinese Medical Journal 2017;(21):2547-2550
Background: Wide resection margins of osseous tumors are associated with a low incidence of local recurrence, making accurate measurement of the intraosseous extent of primary malignant long bone tumors is crucial. We compared the intraosseous tumor extent assessed by magnetic resonance imaging (MRI) with the gross specimen to evaluate the accuracy of MRI. Methods: A total of 255 patients with primary malignant tumors in the long bones were included. Using MRI, we defined the length of tumor as the distance from the articular surface to the boundary between abnormal and normal marrow signal. The extent of the abnormal intraosseous signal was measured on unenhanced T1?weighted (T1WI) magnetic resonance images after chemotherapy. All gross surgical specimens were sectioned, and tumor extent was measured. Wilcoxon signed?rank test was used to test the differences between MRI and gross specimen findings. Spearman's correlation analysis was used to test the correlation between groups. Results: Median tumor length by gross specimen (112 mm; range, 45–300 mm) was longer than that by MRI (108 mm; range, 45–304 mm;Z = ?6.916, P < 0.001). Of 255 images, tumor length was accurately represented on 27 T1WI magnetic resonance images, overestimated on 79 images, and underestimated on 149 images. The median difference between imaging and gross specimen measurements was 2.0 mm (range: 1.0–15.0 mm) for the 79 cases where tumor length was overestimated, and 5.0 mm (range: 1.0–18.0 mm) for the 149 cases where tumor length was underestimated. The Spearman correlation demonstrated a high correlation of tumor length on gross specimen with the tumor length on MRI (R = 0.99, P < 0.01). Conclusions: We conclude that preoperative MRI could be a useful method in determining intramedullary malignant bone tumor boundaries and may serve as an accepted assessment method of long bone tumors before limb?sparing surgery.

Result Analysis
Print
Save
E-mail