1.Anti-COVID-19 mechanism of Anoectochilus roxburghii liquid based on network pharmacology and molecular docking
Jin ZHU ; Yan-bin WU ; De-fu HUANG ; Bing-ke BAI ; Xu-hui HE ; Dan JIA ; Cheng-jian ZHENG
Acta Pharmaceutica Sinica 2024;59(3):633-642
italic>Anoectochilus roxburghii liquid (spray, a hospital preparation of Wu Mengchao Hepatobiliary Hospital of Fujian Medical University) has shown a good clinical treatment effect during the COVID-19 pandemic, but its material basis and mechanism of action are still unclear. In this study, network pharmacology and molecular docking methods were used to predict the molecular mechanism of
2.Simultaneous determination of 6 aconitum-type alkaloids in Xiaozhong ointment by ultra-high performance liquid chromatography triple quadrupole mass spectrometry
Tian-Li XIA ; De-Ping ZHAO ; Ao XUE ; Mei-Ling JIN ; Zi-Yue ZHU ; Qing LI ; Ning ZHANG ; Xia LEI
The Chinese Journal of Clinical Pharmacology 2024;40(9):1341-1344
Objective To establish a method for the simultaneous determination of aconitine,neoaconitine,hypaconitine,benzoyl aconitine,benzoyl mesaconine and benzoylhypacoitine in Xiaozhong ointment by UPLC-TQD-MS.Methods ACQUITY UPLC BEH C18 column(50 mm ×2.1 mm,1.7 μm),mobile phase 0.1%formic acid water(A)-acetonitrile(B),gradient elution,column temperature 40 ℃,flow rate 0.3 mL·min-1,injection volume 5 μL;electrospray ionization source(ESI+)and multiple reaction monitoring(MRM)were used for mass spectrometry analysis.Results The concentration of aconitine,new aconitine,hypaconitine,benzoyl aconitine,benzoyl new aconitine and benzoyl hypaconitine were 1.0-100.0 ng·mL-1,respectively,the average recovery were 98.62%-101.24%.The mass fractions of the six components were 0.18,0.33,0.38,0.43,0.28,0.06μg·g-1.Conclusion The method can be used to determine the content of 6 aconitine-type alkaloids in Xiaozhong ointment,and provide reference for the quality evaluation and clinical safe use of Xiaozhong ointment.
3.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
4.Localization and anatomical measurement of lateral compression Ⅱscrew guide needle insertion point for pelvic fracture
Yong-Zheng CHEN ; Zhen-Hua HU ; Shao-Juan LI ; Xia-Cun LIANG ; Li-Kang HOU ; Shu-Liang ZHU ; Xin-Ying BAI ; Jin-Jian HE ; De-Meng YANG ; Zhi-Guo CHEN
Acta Anatomica Sinica 2024;55(6):728-733
Objective To measure the distance between the lateral compression Ⅱ(LC-Ⅱ)screw guide needle and the surrounding important structures around the anterior inferior iliac spine in pelvic fractures and to locate the needle point,so as to provide anatomical reference for clinical nail placement.Methods Totally 40 adult gross specimens of embalming were implanted with LC-Ⅱ screw guide needle under the surveillance of C-arm machine,and the specimens were dissected.The shortest distance between the insertion point and the lateral femoral cutaneous nerve,femoral nerve,femoral artery,femoral vein,anterior superior iliac spine and inguinal ligament was measured.The triangle was constructed between the insertion point,anterior superior iliac spine and inguinal ligament,and the exact location of the entry point was calculated.Results The average distance between the insertion point of the male needle and the femoral vein was(50.67±7.29)mm>the anterior superior iliac spine(43.83±7.58)mm>the femoral artery(38.35±6.63)mm>the femoral nerve(31.17±1.67)mm=the inguinal ligament(28.69±6.59)mm>the lateral femoral cutaneous nerve(7.98±3.81)mm.The mean distance between the insertion point of the female needle and the anterior superior iliac spine was(45.28±7.07)mm=femoral vein(43.72±6.89)mm>femoral artery(33.76±6.33)mm>femoral nerve(25.66±6.46)mm=inguinal ligament(23.22±5.00)mm>lateral femoral cutaneous nerve(8.97±4.76)mm.The projection distance of the entry point was 31.77 mm for men and 38.41 mm for women.The Angle b was 42.81°for men and 31.71° for women.Conclusion The lateral femoral cutaneous nerve is most vulnerable to injury when LC-Ⅱ screw is inserted,and the risk of injury has nothing to do with sex.The insertion point positioning method a and b made LC-Ⅱ screw placement quickly,safely and accurately,and reduced fluoroscopy time and frequency.
5.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
6. JTE-013 mediates RhoA/ROCKl/Drpl signaling axis regulating mitochondrial damage and apoptosis to alleviate allergic rhinitis
Jiao CHEN ; Long-Zhu DAI ; Mu CHEN ; Yi-Lan SONG ; Guang-Hai YAN ; Chong-Yang WANG ; Yong-De JIN ; Jiao CHEN ; Mu CHEN ; Yong-De JIN ; Long-Zhu DAI ; Yi-Lan SONG ; Guang-Hai YAN ; Chong-Yang WANG
Chinese Pharmacological Bulletin 2023;39(9):1638-1647
Aim To investigate the protective effect and mechanism of JTE-013 on allergic rhinitis (AR) by regulating mitochondrial injury and apoptosis through RhoA/ROCKl/Drpl pathway. Methods AR model was established by ovalbumin (OVA) in mice. Nasal tissue sections were then stained with HE, TUNEL and DHE. Western blot assay. In vitro, human nasal epithelial cells (HNEpCs) were stimulated with human recombinant interleukin-13 (IL-13), and the effects of JTE-013 and Y27632-related protein expression were detected by Western blot. Immunofluorescence was used to observe the effects of JTE-013 and Y 27632 on total ROS, mitochondrial membrane potential and mitochondrial ROS generation, Drpl translocation and Cyt-c expression in cells. Results JTE-013 reduced the frequency of nose rubbing and sneezing, reduced nasal mucosal thickening and decreased eosinophil infiltration in AR mice. TUNEL and DHE staining results suggested that JTE-013 could inhibit apoptosis and reduce ROS expression in mouse nasal epithelial cells. Western blot showed that both JTE-013 and Y 27632 could significantly reduce RhoA, ROCK1, Drpl and p-Drpl(616), inhibit the expression of apoptotic proteins Bax, cleaved-caspase-3, Cyt-c, cleavedcaspase-9 and up-regulate the expression of p-Drpl (637) and Bcl-2. Immunofluorescence showed that inhibitors of JTE-013 or ROCK1 almost blocked IL-13mediated increase in ROS and mtROS production, inhibited decrease in mitochondrial membrane potential, and blocked Cyt-c expression and Drpl translocation in nasal mucosal epithelial cells. Conclusion JTE-013 can regulate the morphology and function of mitochondria by inhibiting RhoA/ROCKl/Drpl signaling axis, thereby alleviating nasal epithelial cell inflammation in mice with allergic rhinitis.
7.Comparison on anti-inflammatory activity of Gynostemma pentaphyllum processed with different methods.
Shu-Yang XU ; Zi-Qing YANG ; Fei TENG ; Xun-Jiang WANG ; Qin HUANG ; De-Zhen JIN ; Min LI ; Shou-Jin LIU ; Zheng-Tao WANG ; Li-Li DING ; Jing-Jing ZHU
China Journal of Chinese Materia Medica 2023;48(19):5235-5243
The aim of this study is to investigate the effects of Gynostemma pentaphyllum dried with two different methods(air drying and heating) on inflammation in acute lung injury(ALI) mice in vivo and in vitro. Lipopolysaccharide(LPS) was sprayed into the airway of wild type C57BL/6J male mice to establish the model, and the drug was injected into the tail vein 24 h after modeling. Lung function, lung tissue wet/dry weight(W/D) ratio, the total protein concentration, interleukin 6(IL-6), IL-1β, and tumor necrosis factor-α(TNF-α) in the bronchoalveolar lavage fluid(BALF), and pathological changes of the lung tissue were used to evaluate the effects of different gypenosides on ALI mice. The results showed that total gypenosides(YGGPs) and the gypenosides substituted with one or two glycosyl(GPs_(1-2)) in the air-dried sample improved the lung function, significantly lowered the levels of IL-1β and TNF-α in BALF, and alleviated the lung inflammation of ALI mice. Moreover, GPs_(1-2) had a more significant effect on inhibiting NO release in RAW264.7 cells. This study showed that different drying methods affected the anti-inflammatory activity of G. pentaphyllum, and the rare saponins in the air-dried sample without heating had better anti-inflammatory activity.
Male
;
Mice
;
Animals
;
Tumor Necrosis Factor-alpha/metabolism*
;
Gynostemma
;
Mice, Inbred C57BL
;
Lung
;
Anti-Inflammatory Agents/metabolism*
;
Interleukin-6/metabolism*
;
Interleukin-1beta/metabolism*
;
Lipopolysaccharides/pharmacology*
8.The mechanism research of Xiaoyan Lidan formula for the intervention of chronic intrahepatic cholestasis based on metabolomics combined with molecular docking analysis
Si-min CHEN ; Jin-hao HUANG ; De-qin WANG ; Yu-ying XIA ; Mei-qi WANG ; Run-feng SHI ; Fang-le LIU ; Chen-chen ZHU ; Chao-zhan LIN
Acta Pharmaceutica Sinica 2023;58(11):3408-3420
In this study, the mechanism of Xiaoyan Lidan formula (XYLDF) against 3,5-diethoxycarbonyl-1,4-dihydro-2,4,6-collidine (DDC)-induced chronic intrahepatic cholestasis (CIHC) in mice was investigated based on metabolomics, molecular docking and pharmacological methods. In the pharmacodynamics study, a dosage of 5 g·kg-1 (clinical equivalent) XYLDF was administered in DDC-induced mice, then the effect of XYLDF against CIHC was evaluated by measuring the levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (AKP) as well as total bilirubin (TBIL) in serum and observing liver histopathological changes. All experiments were approved by the Ethical Committee Experimental Animal Center of Guangzhou University of Chinese Medicine (ZYD-2021-001). The serum metabolites of mice in each group were detected and identified based on ultra-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry, and the relevant biological pathways and molecular key targets were further enriched. Molecular docking technology was used to further evaluate the binding activity of the main active ingredients of XYLDF with potential targets. Subsequently, the
9.Comparison of next-generation flow cytometry and next-generation sequencing in the assessment of minimal residual disease in multiple myeloma.
Qing Qing WANG ; Li YAO ; Ming Qing ZHU ; Ling Zhi YAN ; Song JIN ; Jing Jing SHANG ; Xiao Lan SHI ; Ying Ying ZHAI ; Shuang YAN ; Wei Qin YAO ; Hong Ying YOU ; De Pei WU ; Cheng Cheng FU
Chinese Journal of Hematology 2023;44(4):328-332
10.Efficacy and safefy of Polymyxin B treatment for neutropenic patients suffering from refractory Gram-negative bacterial bloodstream infection.
Meng ZHOU ; Hui Zhu KANG ; Cheng Yuan GU ; Yue Jun LIU ; Ying WANG ; Miao MIAO ; Jian Hong FU ; Xiao Wen TANG ; Hui Ying QIU ; Cheng Cheng FU ; Zheng Ming JIN ; Cai Xia LI ; Su Ning CHEN ; Ai Ning SUN ; De Pei WU ; Yue HAN
Chinese Journal of Hematology 2023;44(6):484-489
Objective: To assess the efficacy and safety of polymyxin B in neutropenic patients with hematologic disorders who had refractory gram-negative bacterial bloodstream infection. Methods: From August 2021 to July 2022, we retrospectively analyzed neutropenic patients with refractory gram-negative bacterial bloodstream infection who were treated with polymyxin B in the Department of Hematology of the First Affiliated Hospital of the Soochow University between August 2021 to July 2022. The cumulative response rate was then computed. Results: The study included 27 neutropenic patients with refractory gram-negative bacterial bloodstream infections. Polymyxin B therapy was effective in 22 of 27 patients. The median time between the onset of fever and the delivery of polymyxin B was 3 days [interquartile range (IQR) : 2-5]. The median duration of polymyxin B treatment was 7 days (IQR: 5-11). Polymyxin B therapy had a median antipyretic time of 37 h (IQR: 32-70). The incidence of acute renal dysfunction was 14.8% (four out of 27 cases), all classified as "injury" according to RIFLE criteria. The incidence of hyperpigmentation was 59.3%. Conclusion: Polymyxin B is a viable treatment option for granulocytopenia patients with refractory gram-negative bacterial bloodstream infections.
Humans
;
Polymyxin B/adverse effects*
;
Retrospective Studies
;
Gram-Negative Bacterial Infections/complications*
;
Fever/drug therapy*
;
Sepsis/drug therapy*
;
Anti-Bacterial Agents/therapeutic use*
;
Bacteremia/complications*

Result Analysis
Print
Save
E-mail