1.The clinical significance of lateral pelvic sentinel lymph node biopsy using indocyanine green fluorescence navigation in laparoscopic lateral pelvic lymph node dissection
Hao SU ; Zheng XU ; Mandula BAO ; Shou LUO ; Jianwei LIANG ; Wei PEI ; Xu GUAN ; Zheng LIU ; Zheng JIANG ; Mingguang ZHANG ; Zhixun ZHAO ; Weisen JIN ; Haitao ZHOU
Chinese Journal of Oncology 2024;46(2):140-145
Objectives:This study aims to explore the clinical significance of lateral pelvic sentinel lymph node biopsy (SLNB) using indocyanine green (ICG) fluorescence navigation in laparoscopic lateral pelvic lymph node dissection (LLND) and evaluate the accuracy and feasibility of this technique to predict the status of lateral pelvic lymph nodes (LPLNs).Methods:The clinical and pathological characteristics, surgical outcomes, lymph node findings and perioperative complications of 16 rectal cancer patients who underwent SLNB using ICG fluorescence navigation in laparoscopic LLND in the Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College during April 2017 and October 2022 were retrospectively collected and analyzed. The patients did not receive preoperative neoadjuvant radiotherapy and presented with LPLNs but without LPLN enlargement (MRI showed the maximum short axes of the LPLNs were ≥5 mm and <10 mm at first visit).Results:All 16 patients were successfully performed SLNB using ICG fluorescence navigation in laparoscopic LLND. Three patients underwent bilateral LLND and 13 patients underwent unilateral LLND. The lateral pelvic sentinel lymph nodes (SLNs) were clearly fluorescent before dissection in 14 patients and the detection rate of SLNs for these patients was 87.5%. Lateral pelvic SLN metastasis was diagnosed in 2 patients and negative results were found in 12 patients by frozen pathological examinations. Among the 14 patients in whom lateral pelvic SLNs were detected, the dissected lateral pelvic non-SLNs were all negative. All dissected LPLNs were negative in two patients without fluorescent lateral pelvic SLNs. The specificity, sensitivity, negative predictive value, and accuracy was 85.7%, 100%, 100%, and 100%, respectively.Conclusions:This study indicates that lateral pelvic SLNB using ICG fluorescence navigation shows promise as a safe and feasible procedure with good accuracy. This technique may replace preventive LLND for locally advanced lower rectal cancer.
2.Ethylene oxide residue detection method based on multi-component medical devices
Ruo-Jin LIU ; Zi-Meng WANG ; Hui LI ; Wen-Liang SHAO ; Bao-Yu LIU ; Yi FENG
Chinese Medical Equipment Journal 2024;45(1):56-61
Objective To establish a stable and reliable method for the determination of ethylene oxide residue,and to analyze ethylene oxide residue in multi components made of different materials involved in some medical devices,so as to provide references for sample selection and ethylene oxide residue detection of multi-component medical device kits.Methods A method for the determination of ethylene oxide residue of multi-component medical devices was developed using headspace-gas chromatography and DB-WAX column under the conditions of headspace extraction with equilibration at 80℃ for 20 min,and the weighing mass,linearity,limit of detection,limit of quantification,precision and recovery of the method were determined.Trials of the method were carried out on the items undergoing ethylene oxide sterilization,including disposable perineal care kit,disposable gynecological examination kit,disposable suture dressing kit,disposable debridement kit and the components contacting human body in the disposable dialysis kit,and the abilities of different materials of the components were analyzed in absorbing,retaining and releasing ethylene oxide.Results The method showed high linearity(r=0.999 8)in the range of ethylene oxide mass concentration from 0.4 to 16.0 μg/mL with a weighing mass of 1.00 g,which had the limit of detection being 0.11 μg/mL,the limit of quantification being 0.37 μg/mL and the relative standard deviations(RSDs)for the precision from 0.35%to 1.52%.The average recoveries of different spiked amounts of ethylene oxide in the three blank matrices ranged from 92.68%to 101.42%with the relative standard deviations(RSDs)from 2.46%to 7.59%,which all satisfied the detection requirements.The components made of rubber and acrylonitrile-butadiene-styrene copolymer(ABS)in multi-component medical device kits had the highest ethylene oxide residues,followed by the components made of wood,degreased cotton,polypropylene and polystyrene.Conclusion The method proposed gains advantages in easy operation and high specificity,quantification and reproducibility,which can be used for the determination of ethylene oxide residue in the multi-component medical device kit undergoing ethylene oxide sterilization.References are provided for sample selection of multi-component medical devices.[Chinese Medical Equipment Journal,2024,45(1):56-61]
3.The clinical significance of lateral pelvic sentinel lymph node biopsy using indocyanine green fluorescence navigation in laparoscopic lateral pelvic lymph node dissection
Hao SU ; Zheng XU ; Mandula BAO ; Shou LUO ; Jianwei LIANG ; Wei PEI ; Xu GUAN ; Zheng LIU ; Zheng JIANG ; Mingguang ZHANG ; Zhixun ZHAO ; Weisen JIN ; Haitao ZHOU
Chinese Journal of Oncology 2024;46(2):140-145
Objectives:This study aims to explore the clinical significance of lateral pelvic sentinel lymph node biopsy (SLNB) using indocyanine green (ICG) fluorescence navigation in laparoscopic lateral pelvic lymph node dissection (LLND) and evaluate the accuracy and feasibility of this technique to predict the status of lateral pelvic lymph nodes (LPLNs).Methods:The clinical and pathological characteristics, surgical outcomes, lymph node findings and perioperative complications of 16 rectal cancer patients who underwent SLNB using ICG fluorescence navigation in laparoscopic LLND in the Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College during April 2017 and October 2022 were retrospectively collected and analyzed. The patients did not receive preoperative neoadjuvant radiotherapy and presented with LPLNs but without LPLN enlargement (MRI showed the maximum short axes of the LPLNs were ≥5 mm and <10 mm at first visit).Results:All 16 patients were successfully performed SLNB using ICG fluorescence navigation in laparoscopic LLND. Three patients underwent bilateral LLND and 13 patients underwent unilateral LLND. The lateral pelvic sentinel lymph nodes (SLNs) were clearly fluorescent before dissection in 14 patients and the detection rate of SLNs for these patients was 87.5%. Lateral pelvic SLN metastasis was diagnosed in 2 patients and negative results were found in 12 patients by frozen pathological examinations. Among the 14 patients in whom lateral pelvic SLNs were detected, the dissected lateral pelvic non-SLNs were all negative. All dissected LPLNs were negative in two patients without fluorescent lateral pelvic SLNs. The specificity, sensitivity, negative predictive value, and accuracy was 85.7%, 100%, 100%, and 100%, respectively.Conclusions:This study indicates that lateral pelvic SLNB using ICG fluorescence navigation shows promise as a safe and feasible procedure with good accuracy. This technique may replace preventive LLND for locally advanced lower rectal cancer.
4.Determination of 2-chloroethanol and ethylene glycol residues in disposable infusion sets
Ruo-Jin LIU ; Bao-Yu LIU ; Hui LI ; Yi FENG ; Wen-Liang SHAO
Chinese Medical Equipment Journal 2024;45(10):31-36
Objective To propose an effective method for the determination of 2-chloroethanol(ethylene chlorohydrin,ECH)and ethylene glycol(EG)residues in disposable infusion sets sterilized by ethylene oxide(EO).Methods Extraction with the ratio of the mass of the disposable infusion set to the volume of the medium being 0.4 g/mL was carried out with the 8890B gas chromatograph with liquid injection,DB-WAX column and ethanol extraction medium,and quantitative determination of ECH and EG in disposable infusion sets were implemented after extraction at 37℃for 10 h.Results The method proposely was highly specific,and showed high linearity in the range of 1.25-100.00 μg/mL for both ECH and EG.The limits of detection were 0.31 and 0.11 μg/mL for ECH and EG,respectively,and the relative standard deviations(RSD)of the precision of ECH was in the range of 0.24%-2.03%and those of EG was in the range of 0.16%-0.87%.The average recoveries were 95.02%-100.58%for ECH and 99.15%-99.98%for EG.Conclusion The method proposed for the determination of ECH and EG residues gains advantages in easy operation,specificity,detection accuracy and reproducibility,and meets the requirements for the determination of ECH and EG residues in EO-sterilized disposable infusion sets.[Chinese Medical Equipment Journal,2024,45(10):31-36]
5.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
6.Recent advance in neutrophil extracellular traps in ischemic stroke
Wenhu LIU ; Juan BAO ; Shaobo MA ; Zhaomeng WEN ; Yuwei SHI ; Jin LIANG
Chinese Journal of Neuromedicine 2023;22(11):1164-1168
Neutrophil extracellular traps (NETs) are compounds composed of depolymerized DNA fibers and antimicrobial peptides released by neutrophils. NETs formation not only plays a role in pathological process of non-infectious diseases such as cystic fibrosis, systemic lupus erythematosus, diabetes and cancer, but also is closely related to many central nervous system diseases. In recent years, a large number of studies have found the presence of neutrophils and NETs in perivascular space of the infarcted lesions in patients with ischemic stroke (IS) and corresponding animal models. This article provides a review on NETs formation and clearance process, characteristics of NETs changes after IS, pathological processes involved in NETs after IS, and effects of NETs on neurons, to provide some references for IS.
7.Clinical efficacy and safety of non-submucosal injection in endoscopic submucosal excavation for small gastric muscularis propria tumors
Yixin JIA ; Liang HUANG ; Lina MENG ; Bin LYU ; Haibiao BAO ; Haifeng JIN
Chinese Journal of Digestive Endoscopy 2023;40(8):616-622
Objective:To evaluate the efficacy and safety of non-submucosal injection in endoscopic submucosal excavation (ESE) for small submucosal tumors originating in the muscularis propria of the stomach.Methods:A total of 138 patients diagnosed as having small gastric muscularis propria tumors (≤2 cm) at Digestive Endoscopy Center of Zhejiang Provincial Hospital of Chinese Medical from November 2018 to October 2020 were randomly divided into the observation group with non-submucosal injection of ESE and the control group with submucosal injection of ESE for a randomized controlled trial. The exposure time, tumor removal time, operation cost, hospitalization period, numbers of metal clips and complications of the two groups were analyzed and compared.Results:A total of 138 patients were enrolled, including 76 patients in the observation group and 62 patients in the control group. All lesions were successfully and completely removed. Compared with the control group, the observation group had shorter median tumor exposure time [2.00 min VS 3.30 min, Z=-2.426, P =0.045], shorter median tumor removal time [16.8 min VS 34.4 min, Z=-4.324, P<0.001], less median surgical cost [2 903 yuan VS 3 178 yuan, Z=-5.112, P<0.001], and fewer metal clips used (4.0±0.6 VS 5.1±1.3, t=1.452, P=0.003). The incidence of postoperative abdominal distension of the observation group was lower [9.2% (7/76) VS 22.6% (14/62), χ2=2.512, P=0.049], the incidence of postoperative abdominal pain of this group was lower too [11.8% (9/76) VS 32.3% (20/62), χ2=4.242, P=0.014], but there was no significant difference in the period of hospitalization, incidence of postoperative fever or perforation ( P>0.05). Conclusion:Non-submucosal injection of ESE is safe and effective for submucosal tumors smaller than 2.0 cm originating from the muscularis propria of the stomach , which might be more advantageous than traditional ESE.
8.Performance and applicability evaluation of pressure infusion cuff and blood warmer under severe cold environments in the field
Yin-Tu MA ; Li CHEN ; Xiao-Fei CHEN ; Yi-Man ZHAO ; Jin-Bao WANG ; Liang WANG ; Li-Hua LI
Chinese Medical Equipment Journal 2023;44(11):117-120
Objective To test the performances and applicability of the pressure infusion cuff and blood warmer under severe cold environments in the field.Methods Under the severe cold conditions in the field,the simulated hemorrhagic shock patient was placed on a stretcher and transported to a transfer vehicle 2 km away,a pressure infusion cuff and blood warmer was used to perform fluid resuscitation and heating and pressurization blood transfusion during the transport,and the effect of heating and pressurization of the device during the transport was evaluated;two healthy adult male pigs were selected to construct animal models of hemorrhagic shock from war wounds,of which one pig was used as an experimental animal to be treated by blood transfusion with a pressure infusion cuff and blood warmer and the other pig was recognized as a control animal to be treated by blood transfusion using commercially available inflatable pressurized bags and thermostats,and comparison analysis was carried out on the changes in vital signs of animals before and after treatment by the 2 methods of warming and pressurization and the effects of warming and pressurization transfusion.Results The pressure infusion cuff and blood warmer gained advantages in convenience,efficiency and applicability during patient transport;the experimental animal behaved better than the control animal in vital signs such as blood volume,pressure and respiration,transfusion speed and fluid warming.Conclusion The pressure infusion cuff and blood warmer has high efficiency and is applicable under severe cold conditions in the field.[Chinese Medical Equipment Journal,2023,44(11):117-120]
9.An acute meningitisand encephalitis syndrome surveillance program for Japanese encephalitis in Baoji city,Shaanxi Province,China
Xiao-Yu ZHANG ; Hong-Zhong DU ; Jin-Bao ZHANG ; Wan-Liang REN
Chinese Journal of Zoonoses 2023;39(11):1112-1116
We analyzed the clinical and biochemical characteristics of Japanese encephalitis(JE),based on acute meningeal and encephalitis syndrome(AMES)surveillancein Baoji from 2013 to 2021.We established the AMES program in Baoji and de-veloped surveillance according to the case definition.JE virus IgM antibody tests were conducted.Positive cases were divided in-to a probable JE and non-probable JE group according to the initial diagnosis.Clinical manifestations and biochemical character-istics of cerebrospinal fluid were compared between groups.The difference in JE incidence in the Baoji area and Shaanxiprovince before and after the AMES program was compared.Among 2 636 AMES cases reported during 2013-2021,the positive rate of JE virus IgM antibody was 5.99%,of which 86 cases(54.43%)lacked an initial JE diagnosis.The proportion of patients with fever,perturbed consciousness,neck rigidity,or meningeal irritation was significantly higher in the group with than without an initial JE diagnosis(P<0.05).Biochemical tests indicated that the differences in cerebrospinal fluid color,white blood cell count,and chloride and glucose levels in the two groups were not statistically significant(P>0.05).Cases of JE in Baoji from 2005 to 2012 accounted for 10.65%(134/1258)vs 16.58%(161/971).This study indicated that the AMES surveillance pro-gram increased the detection of JE and has aided in JE diagnosis.Thus,AMES surveillance should be enhanced.
10.Study on the preventive effect of schisandrin on neural tube defects in mice and its mechanism
Yi RU ; Liang-Qi XIE ; Xin-Liang WANG ; Bao-Guo XIAO ; Xiao-Ming JIN ; Cun-Gen MA ; Zhi CHAI ; Hui-Jie FAN
Medical Journal of Chinese People's Liberation Army 2023;48(12):1370-1377
Objective To investigate the preventive effect of schisandrin(SCH)on fetal neural tube defects(NTDs)of mice and its mechanism.Methods C57BL/6 mice were mated with female and male at a ratio of 2:1.Pregnant female mice with vaginal plug after mating were randomly divided into control group,model group,SCH group,and folic acid group,with 9 mice in each group.The NTDs fetal mice model was induced by intraperitoneal injection of all-trans retinoic acid(atRA)(7.5 mg/kg)on embryonic day 7.5(E 7.5 d).During E 0.5 d-E 11.5 d,pregnant rats in folic acid group were given folic acid[61.0 μg/(kg·d)]by gavage once a day,and pregnant rats in SCH group were given SCH[8.0 mg/(kg·d)]by gavage once a day.Fetal mice were removed by cesarean section on E 11.5 d.PC12 cells were divided into control group,model group and SCH group.PC12 cells were treated with atRA(20 μmol/L)for 12 hours to establish cell damage model in model group,and treated with SCH(2.5 μmol/L)for 24 hours in SCH group.Fetuses were identified NTDs by stereoscopic microscopy.HE staining was used to observe the closure of the neural tube.The expression levels of p-PI3K,Akt and p-Akt molecules in PI3K/Akt signaling pathway were detected by Western Blotting.Results Compared with control group,the incidence of NTDs was significantly increased in mice of model group(P<0.01);compared with model group,the incidence of NTDs was decreased in folic acid group and SCH group(P<0.01);compared with folic acid group,SCH group had a lower incidence of NTDs(P<0.01).Western Blotting results showed that compared with control group,the expression of p-PI3K and p-Akt protein in fetal tissues of model group was significantly decreased(P<0.01,P<0.05);compared with model group,there was no significant difference in expression of p-PI3K and p-Akt in fetal tissues of folic acid group(P>0.05),while the expression of p-PI3K and p-Akt protein in SCH group was significantly higher(P<0.05).Compared with control group,PC12 cells in model group showed lower expression levels of p-PI3K and p-Akt(P<0.05);compared with model group,PC12 cells in SCH group showed higher expression levels of p-PI3K and p-Akt(P<0.05).Conclusions SCH can reduce the incidence of atRA-induced NTDs in fetal mice,and its preventive effect is better than folic acid,which may be related to the activation of the PI3K/Akt signaling pathway.

Result Analysis
Print
Save
E-mail