1.Tocilizumab for Patients with Severe Fever with Thrombocytopenia Syndrome: Tocilizumab Observational SFTS Study-1
Jeong Rae YOO ; Misun KIM ; Myeong Jin KANG ; Sora KIM ; Keun Hwa LEE ; Sang Taek HEO
Yonsei Medical Journal 2025;66(5):321-327
There is no established treatment for severe fever with thrombocytopenia syndrome (SFTS). However, the potential role of tocilizumab (TCZ) in cytokine storm modulation warrants further investigation. In this study, we aimed to investigate the therapeutic potential of TCZ in adult patients with SFTS and provide valuable insights into the development of effective treatment strategies for this challenging infectious disease by assessing the impact of TCZ on cytokine dynamics and patient outcomes. This prospective longitudinal observational study included adult patients with SFTS at a teaching hospital in Korea between April 2013 and December 2023. Patients with SFTS and interleukin (IL)-6 levels ≥30 ng/mL received TCZ. The 14- and 28-day mortality rates were compared between the TCZ and therapeutic plasma exchange (TPE) groups during the study period. Among the total of 97 patients, the clinical characteristics showed no significant differences between the TCZ (n=10) and TPE groups (n=30). Compared with TPE, TCZ treatment showed a trend towards lower mortality rate (14-day mortality rate: 10.0% vs. 16.7%, p=0.608; 28-day mortality rate:10.0% vs. 20.0%, p=0.480). Both treatments showed the potential to reduce the viral load and IL-6 levels, indicating their efficacy in managing the disease course. TCZ is a potential therapeutic option for SFTS as it modulates IL-6 levels and improves clinical outcomes.
2.Tocilizumab for Patients with Severe Fever with Thrombocytopenia Syndrome: Tocilizumab Observational SFTS Study-1
Jeong Rae YOO ; Misun KIM ; Myeong Jin KANG ; Sora KIM ; Keun Hwa LEE ; Sang Taek HEO
Yonsei Medical Journal 2025;66(5):321-327
There is no established treatment for severe fever with thrombocytopenia syndrome (SFTS). However, the potential role of tocilizumab (TCZ) in cytokine storm modulation warrants further investigation. In this study, we aimed to investigate the therapeutic potential of TCZ in adult patients with SFTS and provide valuable insights into the development of effective treatment strategies for this challenging infectious disease by assessing the impact of TCZ on cytokine dynamics and patient outcomes. This prospective longitudinal observational study included adult patients with SFTS at a teaching hospital in Korea between April 2013 and December 2023. Patients with SFTS and interleukin (IL)-6 levels ≥30 ng/mL received TCZ. The 14- and 28-day mortality rates were compared between the TCZ and therapeutic plasma exchange (TPE) groups during the study period. Among the total of 97 patients, the clinical characteristics showed no significant differences between the TCZ (n=10) and TPE groups (n=30). Compared with TPE, TCZ treatment showed a trend towards lower mortality rate (14-day mortality rate: 10.0% vs. 16.7%, p=0.608; 28-day mortality rate:10.0% vs. 20.0%, p=0.480). Both treatments showed the potential to reduce the viral load and IL-6 levels, indicating their efficacy in managing the disease course. TCZ is a potential therapeutic option for SFTS as it modulates IL-6 levels and improves clinical outcomes.
3.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
4.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
5.Tocilizumab for Patients with Severe Fever with Thrombocytopenia Syndrome: Tocilizumab Observational SFTS Study-1
Jeong Rae YOO ; Misun KIM ; Myeong Jin KANG ; Sora KIM ; Keun Hwa LEE ; Sang Taek HEO
Yonsei Medical Journal 2025;66(5):321-327
There is no established treatment for severe fever with thrombocytopenia syndrome (SFTS). However, the potential role of tocilizumab (TCZ) in cytokine storm modulation warrants further investigation. In this study, we aimed to investigate the therapeutic potential of TCZ in adult patients with SFTS and provide valuable insights into the development of effective treatment strategies for this challenging infectious disease by assessing the impact of TCZ on cytokine dynamics and patient outcomes. This prospective longitudinal observational study included adult patients with SFTS at a teaching hospital in Korea between April 2013 and December 2023. Patients with SFTS and interleukin (IL)-6 levels ≥30 ng/mL received TCZ. The 14- and 28-day mortality rates were compared between the TCZ and therapeutic plasma exchange (TPE) groups during the study period. Among the total of 97 patients, the clinical characteristics showed no significant differences between the TCZ (n=10) and TPE groups (n=30). Compared with TPE, TCZ treatment showed a trend towards lower mortality rate (14-day mortality rate: 10.0% vs. 16.7%, p=0.608; 28-day mortality rate:10.0% vs. 20.0%, p=0.480). Both treatments showed the potential to reduce the viral load and IL-6 levels, indicating their efficacy in managing the disease course. TCZ is a potential therapeutic option for SFTS as it modulates IL-6 levels and improves clinical outcomes.
6.Clinical practice guidelines for cervical cancer: an update of the Korean Society of Gynecologic Oncology Guidelines
Ji Geun YOO ; Sung Jong LEE ; Eun Ji NAM ; Jae Hong NO ; Jeong Yeol PARK ; Jae Yun SONG ; So-Jin SHIN ; Bo Seong YUN ; Sung Taek PARK ; San-Hui LEE ; Dong Hoon SUH ; Yong Beom KIM ; Keun Ho LEE
Journal of Gynecologic Oncology 2025;36(1):e70-
We describe the updated Korean Society of Gynecologic Oncology (KSGO) practice guideline for the management of cervical cancer, version 5.1. The KSGO announced the fifth version of its clinical practice guidelines for the management of cervical cancer in March 2024. The selection of the key questions and the systematic reviews were based on data available up to December 2022. Between 2023 and 2024, substantial findings from large-scale clinical trials and new advancements in cervical cancer research remarkably emerged. Therefore, based on the existing version 5.0, we updated the guidelines with newly accumulated clinical data and added 4 new key questions reflecting the latest insights in the field of cervical cancer. For each question, recommendation was formulated with corresponding level of evidence and grade of recommendation, all established through expert consensus.
7.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.

Result Analysis
Print
Save
E-mail