1.Radiologic evolution of biopsy-proven acute interstitial nephritis: a multimodal imaging case report
Euljo JEONG ; Bong Soo PARK ; Il Hwan KIM ; Jung Hee SON ; Kyung Han NAM ; Yoon Ho LEE ; Yoo Jin LEE
Kosin Medical Journal 2025;40(1):72-79
This report presents radiologic changes after clinical improvement in a patient with acute interstitial nephritis (AIN). A 45-year-old female patient was referred for decreased renal function. Eight months prior, she had undergone hysterectomy and received chemotherapy. At the start of chemotherapy, her baseline creatinine level was 0.55 mg/dL, which rose to 1.46 mg/dL. Multiple imaging modalities performed when decreased renal function was observed revealed bilateral renal enlargement with increased cortical attenuation on computed tomography (CT), cortical hyperechogenicity on ultrasonography, and diffusion restriction in the renal cortices on magnetic resonance imaging. A renal biopsy was performed, and AIN was diagnosed. Follow-up laboratory tests showed that kidney function had improved to normal levels, and CT at that time showed a reduction in the size of both kidneys. Radiologic changes can serve as clues for the diagnosis of AIN. This is the first report to confirm radiological changes after the clinical improvement of AIN, thereby providing novel information about the course of AIN.
2.A Nationwide Survey on Infection Prevention and Control in Acute Care Hospitals of Korea
Sun Hee NA ; Yubin SEO ; Hye Jin SHI ; In Sun HWANG ; Kyong A SHIN ; Kwang Yul SON ; Sung Ran KIM ; Myoungjin SHIN ; Hee-jung SON ; Ji Youn CHOI ; Heekyung CHUN ; Sook-Kyung PARK ; Jeongsuk SONG ; Namyi KIM ; Jacob LEE ; Joong Sik EOM
Journal of Korean Medical Science 2025;40(4):e41-
Background:
Healthcare-associated infections impose a significant burden on antibiotic usage, healthcare expenditures, and morbidity. Therefore, it is crucial to revise policies to minimize such losses. This nationwide survey aimed to evaluate infection prevention and control (IPC) components in healthcare facilities and encourage improvements in acute care hospitals with inadequate infection prevention settings. This study aims to enhance the infection control capabilities of healthcare facilities.
Methods:
From December 27, 2021, to May 13, 2022, we conducted a survey of 1,767 acute care hospitals in the Republic of Korea. A survey was conducted to evaluate the infection control components in 1,767 acute care hospitals. Infection control officers provided direct responses to a systematically developed questionnaire. Subsequently, 10% of the respondents were randomly selected for the site investigation.
Results:
Overall, 1,197 (67.7%) hospitals responded to the online survey. On-site investigations were conducted at 125 hospitals. Hospitals with ≥ 150 beds are advised to have an IPC team under Article 3 of the Medical Service Act; however, only 87.0% (598/687) of hospitals with ≥ 100 beds had one. Conversely, 22.7% (116/510) of hospitals with < 100 beds had an IPC team. Regulations for hand hygiene, waste management, healthcare worker protection and safety, environmental cleaning, standard precautions, and prevention of the transmission of multidrug-resistant pathogens were present in 84.2%, 80.1%, 77.4%, 76.2%, 75.8%, and 63.5% of the hospitals, respectively. Hospitals with < 100 beds had low availability of all categories of standard operating procedures.
Conclusion
This study is the first national survey of acute care hospitals in the Republic of Korea. The data presented in the current study will improve the understanding of IPC status and will help establish a survey system. Our survey provides a basis for improving policies related to IPC in healthcare facilities.
3.Ectopic Mediastinal Thyroid Successfully Removed by Surgical Excision via Transcervical Approach
Seung Yup SON ; Se Hyeon JIN ; Jong Hwan LEE ; Su Il KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(4):168-171
Ectopic thyroid is thyroid tissue found in places other than the anterolateral aspect of the second to fourth tracheal ring. Mediastinal ectopic thyroid is rare and only few cases have been reported. The authors experienced a case of 41-year-old female patient with an anterior neck mass. The patient had mild chest discomfort when breathing with no other symptoms. Imaging studies suggested tumor of thymic tissue origin and surgical excision was done. The mass was successfully removed and histopathologically determined to be thyroid tissue. We hereby report with a review of literature a case of ectopic thyroid found in the mediastinum, which was successfully removed by transcervical incision.
4.Radiologic evolution of biopsy-proven acute interstitial nephritis: a multimodal imaging case report
Euljo JEONG ; Bong Soo PARK ; Il Hwan KIM ; Jung Hee SON ; Kyung Han NAM ; Yoon Ho LEE ; Yoo Jin LEE
Kosin Medical Journal 2025;40(1):72-79
This report presents radiologic changes after clinical improvement in a patient with acute interstitial nephritis (AIN). A 45-year-old female patient was referred for decreased renal function. Eight months prior, she had undergone hysterectomy and received chemotherapy. At the start of chemotherapy, her baseline creatinine level was 0.55 mg/dL, which rose to 1.46 mg/dL. Multiple imaging modalities performed when decreased renal function was observed revealed bilateral renal enlargement with increased cortical attenuation on computed tomography (CT), cortical hyperechogenicity on ultrasonography, and diffusion restriction in the renal cortices on magnetic resonance imaging. A renal biopsy was performed, and AIN was diagnosed. Follow-up laboratory tests showed that kidney function had improved to normal levels, and CT at that time showed a reduction in the size of both kidneys. Radiologic changes can serve as clues for the diagnosis of AIN. This is the first report to confirm radiological changes after the clinical improvement of AIN, thereby providing novel information about the course of AIN.
5.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
6.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
7.Pathogenesis of systemic sclerosis: an integrative review of recent advances
Journal of Rheumatic Diseases 2025;32(2):89-104
Systemic sclerosis (SSc), or scleroderma, is a complex autoimmune connective tissue disease characterized by autoimmunity, vasculopathy, and progressive organ fibrosis, leading to severe organ dysfunction. The disease begins with a vascular injury triggered by autoimmune responses and environmental factors against a backdrop of genetic predisposition. This injury impairs angiogenesis and vasculogenesis, resulting in capillary loss and arteriolar constriction, which promotes immune cell infiltration and sustained inflammation within affected tissues. These vascular anomalies cause severe complications, including pulmonary artery hypertension, scleroderma renal crisis, and skin ulcers. Chronic inflammation fosters persistent fibroblast activation, resulting in extensive fibrosis that defines SSc. This review synthesizes the latest research on pathogenesis of SSc, highlighting the shift from fundamental research to a precision therapeutic approach. It explores the potential of technologies like flow cytometry and singlecell RNA sequencing to investigate pathogenic cell subtypes. These platforms integrate transcriptomic, genomic, proteomic, and epigenomic data to uncover insights into the underlying mechanisms of SSc pathogenesis. This review advocates for a multidisciplinary, patient-centric approach that harnesses recent scientific advances, directing future SSc research toward personalized and precise interventions.
8.Ectopic Mediastinal Thyroid Successfully Removed by Surgical Excision via Transcervical Approach
Seung Yup SON ; Se Hyeon JIN ; Jong Hwan LEE ; Su Il KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(4):168-171
Ectopic thyroid is thyroid tissue found in places other than the anterolateral aspect of the second to fourth tracheal ring. Mediastinal ectopic thyroid is rare and only few cases have been reported. The authors experienced a case of 41-year-old female patient with an anterior neck mass. The patient had mild chest discomfort when breathing with no other symptoms. Imaging studies suggested tumor of thymic tissue origin and surgical excision was done. The mass was successfully removed and histopathologically determined to be thyroid tissue. We hereby report with a review of literature a case of ectopic thyroid found in the mediastinum, which was successfully removed by transcervical incision.
9.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
10.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.

Result Analysis
Print
Save
E-mail