1.Nasal Nitric Oxide as an Objective Evaluation Tool for Treatment Response in Chronic Rhinitis
Sangeun LEE ; Su Mi SEONG ; Hyeop OH ; Jihun YOON ; Bo Hae KIM ; Joo Hyun PARK ; Yun-Sung LIM ; Chang Gun CHO ; Seok-Won PARK ; Jin Youp KIM
Journal of Rhinology 2025;32(1):40-47
Background and Objectives:
Inconsistencies in nasal nitric oxide (nNO) values, due to anatomical variations and comorbidities, challenge the accurate assessment of upper airway inflammation severity. We hypothesized that changes in nNO levels following treatment for chronic rhinitis would be consistent and provide relative value. This study aimed to evaluate the correlation between changes in nNO levels and symptomatic improvements following treatment for chronic rhinitis.
Methods:
This prospective observational study included 46 participants diagnosed with chronic rhinitis between December 2021 and November 2023. nNO measurements, evaluations of four nasal and two ocular symptoms, and quality of life questionnaires were conducted at baseline and after one month of treatment. Baseline laboratory tests included serum total immunoglobulin E levels, blood eosinophil percentages, and skin prick tests.
Results:
The Total Nasal Symptom Score (TNSS), TNSS with ocular symptoms (TNSS eye), and Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) scores significantly decreased following treatment (all p<0.001). nNO levels also decreased significantly after treatment (p=0.036). Moreover, changes in nNO were significantly correlated with changes in TNSS, TNSS eye, and RQLQ scores (p=0.047, r=0.294; p=0.021, r=0.340; and p=0.004, r=0.419, respectively).
Conclusion
In patients with chronic rhinitis, changes in TNSS, TNSS eye, and RQLQ scores were correlated with changes in nNO levels after treatment. nNO may serve as a potential objective evaluation tool for chronic rhinitis, particularly in patients who have difficulty reporting symptoms.
2.Nasal Nitric Oxide as an Objective Evaluation Tool for Treatment Response in Chronic Rhinitis
Sangeun LEE ; Su Mi SEONG ; Hyeop OH ; Jihun YOON ; Bo Hae KIM ; Joo Hyun PARK ; Yun-Sung LIM ; Chang Gun CHO ; Seok-Won PARK ; Jin Youp KIM
Journal of Rhinology 2025;32(1):40-47
Background and Objectives:
Inconsistencies in nasal nitric oxide (nNO) values, due to anatomical variations and comorbidities, challenge the accurate assessment of upper airway inflammation severity. We hypothesized that changes in nNO levels following treatment for chronic rhinitis would be consistent and provide relative value. This study aimed to evaluate the correlation between changes in nNO levels and symptomatic improvements following treatment for chronic rhinitis.
Methods:
This prospective observational study included 46 participants diagnosed with chronic rhinitis between December 2021 and November 2023. nNO measurements, evaluations of four nasal and two ocular symptoms, and quality of life questionnaires were conducted at baseline and after one month of treatment. Baseline laboratory tests included serum total immunoglobulin E levels, blood eosinophil percentages, and skin prick tests.
Results:
The Total Nasal Symptom Score (TNSS), TNSS with ocular symptoms (TNSS eye), and Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) scores significantly decreased following treatment (all p<0.001). nNO levels also decreased significantly after treatment (p=0.036). Moreover, changes in nNO were significantly correlated with changes in TNSS, TNSS eye, and RQLQ scores (p=0.047, r=0.294; p=0.021, r=0.340; and p=0.004, r=0.419, respectively).
Conclusion
In patients with chronic rhinitis, changes in TNSS, TNSS eye, and RQLQ scores were correlated with changes in nNO levels after treatment. nNO may serve as a potential objective evaluation tool for chronic rhinitis, particularly in patients who have difficulty reporting symptoms.
3.Nasal Nitric Oxide as an Objective Evaluation Tool for Treatment Response in Chronic Rhinitis
Sangeun LEE ; Su Mi SEONG ; Hyeop OH ; Jihun YOON ; Bo Hae KIM ; Joo Hyun PARK ; Yun-Sung LIM ; Chang Gun CHO ; Seok-Won PARK ; Jin Youp KIM
Journal of Rhinology 2025;32(1):40-47
Background and Objectives:
Inconsistencies in nasal nitric oxide (nNO) values, due to anatomical variations and comorbidities, challenge the accurate assessment of upper airway inflammation severity. We hypothesized that changes in nNO levels following treatment for chronic rhinitis would be consistent and provide relative value. This study aimed to evaluate the correlation between changes in nNO levels and symptomatic improvements following treatment for chronic rhinitis.
Methods:
This prospective observational study included 46 participants diagnosed with chronic rhinitis between December 2021 and November 2023. nNO measurements, evaluations of four nasal and two ocular symptoms, and quality of life questionnaires were conducted at baseline and after one month of treatment. Baseline laboratory tests included serum total immunoglobulin E levels, blood eosinophil percentages, and skin prick tests.
Results:
The Total Nasal Symptom Score (TNSS), TNSS with ocular symptoms (TNSS eye), and Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) scores significantly decreased following treatment (all p<0.001). nNO levels also decreased significantly after treatment (p=0.036). Moreover, changes in nNO were significantly correlated with changes in TNSS, TNSS eye, and RQLQ scores (p=0.047, r=0.294; p=0.021, r=0.340; and p=0.004, r=0.419, respectively).
Conclusion
In patients with chronic rhinitis, changes in TNSS, TNSS eye, and RQLQ scores were correlated with changes in nNO levels after treatment. nNO may serve as a potential objective evaluation tool for chronic rhinitis, particularly in patients who have difficulty reporting symptoms.
4.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
5.Deep learning-based surgical phase recognition in laparoscopic cholecystectomy
Hye Yeon YANG ; Seung Soo HONG ; Jihun YOON ; Bokyung PARK ; Youngno YOON ; Dai Hoon HAN ; Gi Hong CHOI ; Min-Kook CHOI ; Sung Hyun KIM
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(4):466-473
Background:
s/Aims: Artificial intelligence (AI) technology has been used to assess surgery quality, educate, and evaluate surgical performance using video recordings in the minimally invasive surgery era. Much attention has been paid to automating surgical workflow analysis from surgical videos for an effective evaluation to achieve the assessment and evaluation. This study aimed to design a deep learning model to automatically identify surgical phases using laparoscopic cholecystectomy videos and automatically assess the accuracy of recognizing surgical phases.
Methods:
One hundred and twenty cholecystectomy videos from a public dataset (Cholec80) and 40 laparoscopic cholecystectomy videos recorded between July 2022 and December 2022 at a single institution were collected. These datasets were split into training and testing datasets for the AI model at a 2:1 ratio. Test scenarios were constructed according to structural characteristics of the trained model. No pre- or post-processing of input data or inference output was performed to accurately analyze the effect of the label on model training.
Results:
A total of 98,234 frames were extracted from 40 cases as test data. The overall accuracy of the model was 91.2%. The most accurate phase was Calot’s triangle dissection (F1 score: 0.9421), whereas the least accurate phase was clipping and cutting (F1 score:0.7761).
Conclusions
Our AI model identified phases of laparoscopic cholecystectomy with a high accuracy.
6.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
7.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
8.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
9.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
10.Evaluation of Factors Influencing Maxillary Sinus Floor Augmentation for Implant Placement: A Retrospective Study
Jihun CHA ; Jaeyoung RYU ; Seunggon JUNG ; Hong-Ju PARK ; Hee-Kyun OH ; Min-Suk KOOK
Journal of implantology and applied sciences 2024;28(2):77-87
Purpose:
This retrospective study compared the maxillary sinus floor augmentation techniques (lateral and transcrestal approaches) to assess the impact of bone grafting, graft materials, and initial residual bone height (RBH). Materials and Methods: Fifty patients who underwent maxillary sinus floor augmentation for posterior maxillary implant placement were included. Panoramic radiographs were obtained before surgery (T0), immediately after surgery (T1), and 6-10 months post-surgery (T2). Length measurements on panoramic radiographs were performed using a digital caliper at T1 and T2. Statistical validation included one-way ANOVA, t-tests, Mann-Whitney U tests, and correlation analyses. Multivariate linear regression was used to assess associations after adjusting for confounding factors.
Results:
Of the 50 patients, 35 underwent a transcrestal approach and 15 underwent a lateral approach. The results showed significant endosinus bone gain (ESBG) differences between allogeneic and xenogeneic grafts and no grafts (p < .001). Osteotomy sinus floor elevation without grafting yielded 3.24 ± 1.42 of ESBG. When divided into three groups based on initial RBH, RBH 1 had 27 patients, RBH 2 had 12 patients, and RBH 3 had 11 patients. Within the RBH group 1 (RBH under 4), the lateral approach had significantly greater ESBG than the transcrestal approach (p < .001). Multivariate linear regression analysis confirmed statistically significant associations between the studied variables after adjusting for confounding factors.
Conclusion
When the RBH is < 4 mm, lateral-approach sinus augmentation and bone grafting should be performed to attain significant ESBG. The RBH, bone graft materials, and sinus elevation techniques vary considerably in ESBG.

Result Analysis
Print