1.Risk factors of primary Sj?gren's syndrome combined with osteoporosis
Wuxinrui HUANG ; Jing TIAN ; Jieyu HE
Journal of Central South University(Medical Sciences) 2024;49(2):312-318
Primary Sj?gren's syndrome(pSS)is a systemic autoimmune disease that is prevalent in middle-aged and elderly women,characterized by dry mouth,dry eyes,fatigue,and joint pain.Nearly one-third pSS patients have been suffering with osteoporosis(OP),displaying symptoms of lumbago,back pain,and even fracture,all of which severely affect their life quality.Common risk factors for pSS and OP include gender and age,persistent state of inflammation,immune disorders,intestinal flora imbalance,vitamin D deficiency,dyslipidemia and sarcopenia.Meanwhile,the comorbidities of pSS,such as renal tubular acidosis,primary biliary cholangitis,autoimmune thyroid diseases,and drugs(glucocorticoids,methotrexate,and cyclophosphamide)are unique risk factors for pSS complicated with OP.Education,guidance of healthy lifestyle,and OP screening are recommended for bone management of pSS patients.Early detection and intervention are crucial for keeping bone health and life quality in pSS patients.
2.Benchmark dose estimation based on Bayesian model averaging and its application to evaluation of cadmium exposure of population in Baiyin
Nana HE ; Jinfang SUN ; Jieyu HE ; Xiaojin YU
Journal of Environmental and Occupational Medicine 2022;39(9):1004-1010
Background The optimal model method for estimation of benchmark dose (BMD) does not consider the uncertainty of model selection. There is a lack of studies on using Bayesian model averaging (BMA) to estimate BMD. Objective To apply BMA to the exposure assessment of cadmium pollution in China, discuss the role of BMA in estimating BMD based on dose-response models, and to provide methodological support for health risk assessment of hazardous substances. Methods The parameters of five dose-response models (Gamma, Log-logistic, Log-probit, Two-stage, and Weibull models) estimated from the data from a cadmium-contaminated area in Baiyin City of Gansu Province and the urinary cadmium ranges in five cadmium-contaminated areas in China were used to simulate the data of varied correct models with different numbers of dosage groups (5 and 8) and different sample sizes (50, 100, and 200), then the performance of BMA and traditional optimal model were compared. The case analysis used the cadmium exposure data in Baiyin, Gansu Province. All analyses set urinary cadmium as the indicator of cadmium exposure, the abnormal rate of β2-microglobulin as the effect indicator, and the benchmark response to 10%. The correct model (the model used when simulating data), optimal model [the model with smallest Akaike information criterion (AIC)], and BMA were used to estimate BMD and lower confidence limit of benchmark dose (BMDL); the BMDs, BMDLs, and relative deviations from different methods were compared. Results In the simulation study, with increasing sample size or the number of dosage groups, the intervals of the 5th percentile and the 90th percentile of BMD tended to be narrower; when the correct model was a single model, the relative deviation of BMD estimation by BMA was greater than that of the traditional optimal model; when the correct model was an equal weight mixed model, the relative deviation of BMD estimation by BMA was less than that by the traditional optimal model. For the data of cadmium-contaminated areas, the optimal model was a Log-probit model (AIC=1814.46), followed by a Log-logistic model (AIC=1814.57); the BMDs (BMDLs) estimated by the Log-probit model, the Log-logistic model, and BMA were 3.46 (2.68), 3.16 (2.33), and 2.92 (2.07) μg·g−1, respectively. Conclusion The traditional optimal model is still recommended when the correct model is known. However, when the dose-response relationship of a hazardous substance is uncertain or with different sources or exposure grouping, compared with the traditional optimal model, BMA theoretically provides more stable estimation of BMD and BMDL by considering multiple possible alternative models.
3.Expression of EGFR mutation-specific antibody and its significance in lung adenocarcinoma
Xia GU ; Jieyu WU ; Xinming HE ; Yunen LIN ; Ping HE ; Qinian WU ; Guangqiu LI
Chinese Journal of Clinical and Experimental Pathology 2015;(6):652-656
Purpose To investigate the expression and significance of epiderma1 growth factor receptor( EGFR)mutation-specific anti-bodies in 1ung adenocarcinoma. Methods Immunohistochemica1( IHC)technique was used to detect the expression of EGFR muta-tion-specific antibodies(EGFR-19,EGFR-21)and EGFR tota1 protein antibody(EGFR-P)in 171 cases of 1ung adenocarcinoma with resected specimens,and EGFR gene mutation was a1so performed by amp1ification refractory mutation aystem-PCR( ARMS-PCR). The expression of EGFR-19,EGFR-21 and EGFR-P mutant proteins was compared with EGFR gene mutation and their re1ationship with histo1ogica1 c1assification and c1inica1 characteristics were ana1yzed. Results The expression of EGFR mutant protein was corre1ated with the poor differentiation group inc1uding micropapi11ary and so1id predominant types( P=0. 021 ). EGFR-21 high expression was re1ated to p1eura1 invasion(P=0. 005). The coherence of IHC(with EGFR-19/21 antibodies)and ARMS-PCR was existed(Kappa>0. 4 ). Taking ARMS-PCR as a standard,the sensitivity and specificity of EGFR-19 and EGFR-21 were 65. 0% and 89. 4%, 70. 0% and 97. 6%,respective1y. Conclusions Expression of EGFR mutation-specific antibodies is associated with poor differentia-tion and p1eura1 invasion. It suggests a worse prognosis indicator in 1ung adenocarcinoma. Because of the coherence with ARMS-PCR, using IHC with mutation-specific antibodies to detect the mutant proteins of EGFR-19/21 may act as a pre1iminary screening method of EGFR gene mutation.
4.Feasibility of Low Tube Voltage Combined with Low Contrast Dose in 64-slice Spiral CT Cerebral and Carotid Arteriography
Jieyu WANG ; Wei QIAO ; Qiuju LI ; Hongbin SUN ; He SUN ; Jie ZOU
Chinese Journal of Medical Imaging 2015;(7):481-485
PurposeTo evaluate the feasibility of a low-dose contrast medium protocol for 64-slice spiral CT angiography (CTA) of cerebral and carotid using a low-tube-voltage setting, and to compare the display effect of cerebral and carotid arteries by low-tube-voltage low-dose contrast medium and routine-tube-voltage routine-dose contrast medium scanning, and to assess the effect on radiation dose.Materials and MethodsEighty consecutive patients were prospectively selected to perform cerebral and carotid CTA inspection. The patients were randomly divided into control group and low dose group with 40 people in each group. The voltage in control group was 120 kV and the contrast agent was 80 ml; those in low dose group were 80 kV and 50 ml, respectively. The artery image quality was evaluated and venous interference was scored. The CT value, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose in both groups were statistically analyzed.Results The consistency of uniform in artery image quality score and venous interference score was rather high according to the assessment of two physicians (Kappa=0.782 and 0.867). There was no statistical difference in artery image quality score, venous interference score, SNR and CNR between the two groups (Z=-0.864--0.032,P>0.05). The CT value in low dose group was higher than that in control group (differences with statistical significance,t=-8.789-1.715,P<0.05). The CT dose index of volume, dose-length product and effective dose in low dose group were all signiifcantly lower than those in control group (Z=-8.888,t=78.092 and 78.350, respectively,P<0.05).Conclusion The use of low tube voltage and low contrast dose in cerebral and carotid CTA examination can result in high quality images which meets the diagnostic needs and obviously reduce radiation dosage.
5.Repair of radial and digital nerve defect with human acellular nerve allograft:6 cases report
Juyu TANG ; Fang YU ; Panfeng WU ; Zhen HUANG ; Jieyu LIANG ; Bo HE ; Xiaolin LIU
Chinese Journal of Microsurgery 2014;37(5):449-452
Objective To explore the safety and clinical effect of the human acellular nerve allograft (hANG) for repairing peripheral nerve defects.Methods During November,2009 to October,2010,6 patients with 3 digital nerve defects and 3 radial nerve defects were repaired with hANG.During postoperation period,safety was evaluated by local wound response and laboratory testing,while the efficacy was evaluated by British Medical Research Council sensory function assessment standards,static 2-point discrimination (2PD) and Semmes-Weinstein monofilament testing.Results Three patients with 6 digital nerve defects received hANG transplant.The length of nerve graft was 20-50 mm(mean 30.8 mm).After followed up for 31-40 months,the excellent rate of 2PD was 66.7%.Two of 3 patients rahabilited as well as the normal.Three patients with radial nerve defects,whose length of nerve graft was 35-60 mm(mean 48.3 mm).The strength of extensor carpiradialis longus muscle had restored Ⅲ in 1 case,and other 2 cases had no restoration.Conclusion hANG is safe and effective for repairing peripheral nerve defects,especially for digital nerve defects.
6.Progress of MRI in neonatal hypoxia ischemic encephalopathy
International Journal of Pediatrics 2012;39(1):23-26
Hypoxia ischemic encephalopathy(HIE) is the brain hypoxia ischemic damage resulted from perinatal hypoxia.MRI can reflect not only the anatomical and pathological changes of neonatal HIE,but also the molecular and metabolical changes in early stage,and evaluate the property and degree of HIE without radioactive damage,which is considered as an ideal imaging examination method for neonatal HIE.This review will summarize progresses in application of MRI to neonatal HIE diagnosis and prognosis.
7.Transplantation of perforator flaps: Systematic review of 108 case series
Juyu TANG ; Kanghua LI ; Qiande LIAO ; Hongbo HE ; Zhangyuan LIN ; Jieyu LIANG ; Lin LUO ; Panfeng WU ; Dajiang SONG
Chinese Journal of Microsurgery 2010;33(3):186-189,后插1
Objective To explore the clinical outcome of perforator flaps for reconstruction of limb soft tissue defects. Methods In this case series, from 2007 July to 2009 May, 108 cases of perforator flap to reconstruct the defects of the extremities were performed, of these, 98 were free perforator flaps, 10 were pedicled flaps. The perforator flaps included deep inferior epigastric artery perforator flap, anterolateral thigh perforator flap, thoracodorsal artery perforator flap, lateral thigh perforator flap, posterior interosseous artery perforator flap, collateral radial artery perforator flap, medial sural artery perforator flap, posterior tibial artery perforator flap, deep circumflex iliac artery perforator flap and peroneal artery perforator flap. The maximum size of the perforator flap was 44 cmx 9 cm, the minimum size of the perforator flap was 4 em x 2 cm.The donor defect was closed directly. Results Venous congestion occurred in 5 flaps, in 1 case venous congestion was overcomed after released the dressing, 4 flaps requiring reexploration for venous insufficiency,2 had a successful outcome, the other 2 flaps failed . The other 103 flaps were successful. The wounds healed without any infection complications. The follow-up ranges from 6-24 months( 10 months on average). The flaps were of good appearance and not bulky; there were only linear scars on the donor sites, the cosmesis and function of the donor sites were satisfying. Conclusion The muscle, deep fascia and motor nerve are not contained in the flap, the advantages of this type of flap is reducing morbidity of the donor site and its reliable blood supply and suitable thickness for resurfacing, no secondary debuiking is necessary. The perforator flaps can be chosen as the first option to deal with superficial extremity wounds.
8.Anatomic data of the proximal femur and its clinical significance.
Jieyu LIANG ; Kanghua LI ; Qiande LIAO ; Guanghua LEI ; Yihe HU ; Yong ZHU ; Ailan HE
Journal of Central South University(Medical Sciences) 2009;34(8):811-814
OBJECTIVE:
To measure the anatomic data of the proximal femur and to design an internal fixation instrument aiming at subtrochanteric fracture.
METHODS:
We measured the anatomic data of 56 pairs of the matching proximal femur specimens: the diameter of femoral head (HD), the axis length of femoral head (HAL), 135 degree femoral head-neck axis length (HNAL), 135 degree femoral head-neck axis upper length (HNAUL), 135 degree femoral head-neck axis underside length (HNADL), the anterior-posterior axis diameter of femoral neck (NAPD), the upper-underside diameter of femoral neck (NUUD), femoral neck-shaft angle (NFA), femoral shaft lateral cortex-greater trochanter angle (SLGA), the medial-lateral diameter of lesser trochanter level's femoral shaft (LSMLD), the anterior-posterior diameter of lesser trochanter level's femoral shaft (LSAPD), the medial-lateral diameter of 5 cm below lesser trochanter femoral shaft (5 cm MLD), and the anterior-posterior diameter of 5 cm below lesser trochanter femoral shaft (5 cm APD). Part of the data was analyzed and compared.
RESULTS:
HD was (46.69+/-3.73) mm, HAL was (39.22+/-4.17) mm, HNAL was (95.45+/-8.16) mm, HNAUL was (84.02+/-7.11) mm, HNADL was (99.95+/-9.34) mm, NAPD was (26.27+/-3.15) mm, NUUD was (32.24+/-3.31) mm, NFA was 126.21 degree+/-7.13 degree, SLGA was 16.38 degree+/-4.04 degree, LSMLD was (31.05+/-3.57) mm, LSAPD was (27.63+/-2.96) mm, 5 cm MLD was (26.36+/-3.22) mm, and 5 cm APD was (25.59+/-2.75) mm. NFA was positively correlated with SLGA (r=0.396, P=0.003).
CONCLUSION
It is necessary to design internal fixator to fit the anatomical feature of Chinese femur for the treatment of subtrochanteric fracture, and we should thoroughly consider the angle of the SLGA.
Anthropometry
;
Cadaver
;
Equipment Design
;
Femur Head
;
anatomy & histology
;
Femur Neck
;
anatomy & histology
;
Fracture Fixation, Internal
;
instrumentation
;
Hip Fractures
;
surgery
;
Humans

Result Analysis
Print
Save
E-mail