1.Analyzing the result of half-mask respirator fit testing in workers exposed to organic solvents and its influencing factors
Qifan HUANG ; Yingyin ZHANG ; Zepeng LI ; Xi ZHONG ; Xi LUO ; Jiawei ZHU ; Shaojie FU ; Shibiao SU
China Occupational Medicine 2024;51(2):183-187
ObjectiveTo analyze the results of fit testing and its influencing factors on half-mask respirator among workers exposed to organic solvents. Methods A total of 84 workers exposed to organic solvents were selected as the research subjects using a convenience sampling method. The qualitative fit test apparatus of respiratory protection was tested after the workers had put on the half-mask respirats, and 11 facial indicators of the subjects were measured. Results The overall pass rate of the respirator fit testing was 71.4% (60/84). The lowest pass rate was 63.1% (53/84), which occurred during bending movements of workers. The head width, minimum forehead width, face length, nose length, nose depth, head circumference and head length were higher in workers who passed respirator fit testing, compared with those in the failing group (all P<0.05). The result of binary logistic regression analysis showed that gender and face width were influencing factors of the respirator fit testing (both P<0.05). Female workers had a lower pass rate of the fit testing than male workers, and workers with larger face width had a lower pass rate in the fit testing. Conclusion Drastic movement may lead to a decrease in the seal of half-mask respirator of workers exposed to organic solvents. When providing half-mask respirator to workers exposed to organic solvents, employers need to pay attention to the fit of respirators of female works and those with larger face width to ensure the effectiveness of respiratory protection for workers.
2.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
3.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
4.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Comparative Study of Two Common In Vitro Models for the Pancreatic Islet with MIN6
Xinxin CHAO ; Furong ZHAO ; Jiawei HU ; Yanrong YU ; Renjian XIE ; Jianing ZHONG ; Miao HUANG ; Tai ZENG ; Hui YANG ; Dan LUO ; Weijie PENG
Tissue Engineering and Regenerative Medicine 2023;20(1):127-141
BACKGROUND:
Islet transplantation is currently considered the most promising method for treating insulin-dependent diabetes. The two most-studied artificial islets are alginate-encapsulated b cells or b cell spheroids. As three-dimensional (3D) models, both artificial islets have better insulin secretory functions and transplantation efficiencies than cells in twodimensional (2D) monolayer culture. However, the effects of these two methods have not been compared yet. Therefore, in this study, cells from the mouse islet b cell line Min6 were constructed as scaffold-free spheroids or alginate-encapsulated dispersed cells.
METHODS:
MIN6 cell spheroids were prepared by using Agarose-base microwell arrays. The insulin secretion level was determined by mouse insulin ELISA kit, and the gene and protein expression status of the MIN6 were performed by Quantitative polymerase chain reaction and immunoblot, respectively.
RESULTS:
Both 3D cultures effectively promoted the proliferation and glucose-stimulated insulin release (GSIS) of MIN6 cells compared to 2D adherent cells. Furthermore, 1% alginate-encapsulated MIN6 cells demonstrated more significant effects than the spheroids. In general, three pancreatic genes were expressed at higher levels in response to the 3D culture than to the 2D culture, and pancreatic/duodenal homeobox-1 (PDX1) expression was higher in the cells encapsulated in 1% alginate than that in the spheroids. A western blot analysis showed that 1% alginate-encapsulated MIN6 cells activated the phosphoinositide 3-kinase (PI3K)/serine/threonine protein kinase (AKT)/forkhead transcription factor FKHR (FoxO1) pathway more than the spheroids, 0.5% alginate-, or 2% alginate-encapsulated cells did. The 3D MIN6 culture, therefore, showed improved effects compared to the 2D culture, and the 1% alginate-encapsulated MIN6 cells exhibited better effects than the spheroids. The upregulation of PDX1 expression through the activation of the PI3K/AKT/FoxO1 pathway may mediate the improved cell proliferation and GSIS in 1% alginate-encapsulated MIN6 cells.
CONCLUSION
This study may contribute to the construction of in vitro culture systems for pancreatic islets to meet clinical requirements.
8.Imaging study on the relationship between anterior and posterior occlusal planes and temporomandibular osteoarthrosis.
Jiawei ZHONG ; Peidi FAN ; Shoushan HU ; Xinlin GAO ; Yijun LI ; Jun WANG ; Xin XIONG
West China Journal of Stomatology 2023;41(3):297-304
OBJECTIVES:
The aim of this study was to compare the anterior and posterior occlusal plane characteristics of patients with different temporomandibular joint osseous statuses.
METHODS:
A total of 306 patients with initial cone beam CT (CBCT) and cephalograms were included. They were divided into three groups on the basis of their temporomandibular joint osseous status: bilateral normal (BN) group, indeterminate for osteoarthrosis (I) group, and osteoarthrosis (OA) group. The anterior and posterior occlusal planes (AOP and POP) of the different groups were compared. Then, the regression equation was established after adjusting for confounding factors, and a correlation analysis between the occlusion planes and other parameters was performed.
RESULTS:
SNA, SNB, FMA, SN-MP, Ar-Go, and S-Go were correlated with the occlusal planes. Relative to the BN and I groups, the FH-OP of the OA group increased by 1.67° on the average, FH-POP increased by 1.42° on the average, and FH-AOP increased by 2.05° on the average.
CONCLUSIONS
The occlusal planes were steeper in the patients with temporomandibular osteoarthrosis than in the patients without it, and the mandible rotated downward and backward. The height of the mandibular ramus, the mandibular body length, and the posterior face height were small. In clinical practice, attention should be given to the potential risk of temporomandibular joint osteoarthrosis in such patients. In addition, SNB, FMA, SN-MP, Ar-Go, S-Go, and occlusal planes had moderate correlations.
Humans
;
Dental Occlusion
;
Cephalometry
;
Mandible
;
Temporomandibular Joint Disorders/diagnostic imaging*
;
Temporomandibular Joint/diagnostic imaging*
;
Osteoarthritis/diagnostic imaging*
;
Mandibular Condyle
9.Practice of two methods in occupational health risk grading and classification management in petroleum refining enterprises
Qifan HUANG ; Jiawei ZHU ; Xi ZHONG ; Rongzong LI ; Zhiheng PENG ; Shibiao SU
Journal of Environmental and Occupational Medicine 2023;40(6):648-654
Background Most of the studies on grading and classification of occupational health compre-hensive risks for specific employers still remain in the establishment and description of methodology, and practical application studies are rarely reported. Objective To explore the application of an occupational disease hazards comprehensive risk assessment method issued by the National Disease Control and Prevention Bureau in conjunction with the National Health Commission and a self-developed occupational health grading and classification method in petroleum refining enterprises, and to provide practical experience for the implementation of differentiated law enforcement by relevant regulatory authorities. Methods Two occupational health grading and classification methods were practiced in three petroleum refining enterprises in Guangdong Province. The occupational hazards comprehensive risk assessment method was provided by the Notice on Carrying out Pilot Work of Occupational Health Classification Supervision and Law Enforcement of the National Disease Control and Prevention Bureau and the National Health Commission. The principle was to derive the occupational health risk level according to nature of occupational hazards, exposure level, and number of workers exposed to them in an employer, and then to classify them into Class A, Class B, and Class C by combining with local occupational health management status level. The occupational health grading and classification method was self-developed according to available domestic and foreign occupational health risk assessment methods. Its principle was to calculate the risk level of each workstation in an employer based on published carcinogenicity classification or LD50/LC50 of chemical toxicants, level of noise, exposure parameters such as exposure level and exposure frequency, estimate the comprehensive risk Ro of the target employer by the Romanian comprehensive risk calculation method, and then calculate a comprehensive risk Ro' weighted by the occupational health management index of the target employer and classify it into class A, class B, and class C. Finally, assessment results, scope of application, inquired indicators, advantages,disadvantages and professional competence requirements of the two grading and classification methods were compared. Results The occupational hazards that were evaluated in three enterprises in this study were benzene, toluene, xylene, gasoline, hydrogen sulfide, and noise. The exposure levels of benzene, toluene, xylene, and gasoline were all below 10% OEL (occupational exposure limit), and hydrogen sulfide and noise were disqualified. Occupational hazards such as benzene and hydrogen sulfide were serious occupational hazards in the three enterprises, and the number of workers exposed was 461, 912, and 224, respectively; the HRs (hazard ratings) of benzene, toluene, xylene, gasoline, hydrogen sulfide, and noise were level 5, 3, 2, 3, 5, and 3 respectively. The occupational health management status of the three enterprises was graded as B, A, and B, respectively by the occupational disease hazards comprehensive risk assessment method. The occupational health management index of the three enterprises was graded as B, A, and A, respectively by the occupational health grading and classification method. The comprehensive risk assessment results showed that two enterprises classified into as the highest class C and one into class B by the occupational disease hazards comprehensive risk assessment method, while all three enterprises were classified into class B by the occupational health grading and classification method. Conclusion The two grading and classification methods are not consistent in the evaluation results of petroleum refining enterprises, and there are differences in the evaluation scope, indicators to be collected, and professionalism. It is recommended that occupational health regulators should fully consider the advantages and disadvantages of the two methods and choose the appropriate assessment method according to the actual regulatory purpose.
10.Research on the protective effect of hearing protective device for workers exposed to noise in a motor manufacturing enterprise
Xi ZHONG ; Shaojie FU ; Jiawei ZHU ; Xiang LI ; Bin SHI ; Shibiao SU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(11):814-818
Objective:To understand the current situation of noise hazard in a motor manufacturing enterprise, and to explore the protective effect of workers wearing hearing protective device and its possible influencing factors.Methods:In November 2021, a total of 179 noise workers wearing hearing protective devices in a motor manufacturing company in a city were selected as research objects. Personal attenuation rating (PAR) of workers wearing hearing protective devices was measured. Baseline PAR was analyzed for different subgroups of basic demographic information, noise exposure, and the use of hearing protective devices to evaluate the effect of the intervention. Baseline PAR was compared using nonparametric tests.Results:There were 179 workers from 35 positions in 4 types of work, and the over-standard noise rate was 51.2% (42/82), among which the noise exposure intensity of motor equipment debugging workers was the highest [94.4 dB (A) ]. Compared the baseline PAR of different characteristics, it was found that the baseline PAR of male workers, workers whose daily noise exposure time were <8 h, workers who had used the hearing protective devices for 10 to 14 years, and workers who thought the hearing protective devices were comfortable were all higher, and the differences were statistically significant ( P<0.05). Baseline PAR passing rate was 43.0% (77/179), and PAR of 102 workers who did not pass baseline test increased from 0 (0, 3) dB before intervention to 14 (12, 16) dB after intervention, with statistical significance ( P<0.05) . Conclusion:The noise hazard in this motor manufacturing enterprise is serious, and the protective effect of workers wearing hearing protective devices is not good. Gender, daily noise exposure time, years and comfort of wearing hearing protective device are the possible influencing factors of poor protective effect.

Result Analysis
Print
Save
E-mail