1.Imaging findings of papillary tumor of the pineal region and literature review
Xufei ZHANG ; Lining WANG ; Jie GAO ; Jianxin HU ; Chenyang LIANG ; Mingwang ZHU
Journal of Practical Radiology 2024;40(3):352-355
Objective To investigate the imaging features of papillary tumor of the pineal region(PTPR).Methods The ima-ging data of 10 patients with PTPR confirmed by operation and pathology were analyzed retrospectively.Results All lesions were located in the posterior commissure area of the posterior inferior wall of the third ventricle.All lesions were heterogeneously hyper-intensity on T1WI and hyperintensity on T2WI.Multiple small cysts or microcapsules signal intensity were observed within the tumor.Of all 10 lesions,there were 9 lesions with high signal intensity within or at the edge of the lesion on T1WI.All lesions showed restricted diffusion.All 10 cases showed uneven and obvious enhancement patterns.Midbrain tectum was compressed and moved backward in 5 cases,moved downward in 2 cases,moved forward and downward in 1 case,and was not clearly displayed in other 2 cases.One case was disseminated and 1 case was hyperperfusion.There were all 10 cases with obstructive hydrocephalus and equal or slightly high density on CT imaging,and 4 cases with calcification.Conclusion Imaging characteristics of PTPR included the lesions centered on the posterior commissure,compressed tectum with backward and downward,multiple small cysts or micro-capsules components within the tumor,hyperintensity on T1WI,and uneven and obvious enhancement patterns.
2.Application value of the deep learning-based image reconstruction algorithm in combined head and neck CT angiography with low radiation dose
Yangfei LI ; Weiping ZHU ; Yidi HOU ; Jianxin PANG ; Yicheng FANG ; Huayong ZHU
Chinese Journal of Radiological Medicine and Protection 2024;44(1):53-59
Objective:To explore the differences between the deep learning-based image reconstruction (DLIR) and the adaptive statistical iterative reconstruction V (ASiR-V) algorithms in the radiation dose and image quality of head and neck CT angiography (CTA).Methods:The data of 80 patients undergoing head and neck CTA due to vascular diseases in the head and neck were prospectively collected. These patients were randomly divided into groups A and B based on their examination sequence. The CTA images of group A were reconstructed based on ASiR-V 50%, with a tube voltage of 120 kV and a noise index of 11.0. In contrast, those of group B were reconstructed based on ASiR-V 50% (for group B1) and DLIR-H (for group B2), with a tube voltage of 80 kV and a noise index of 9.0. Then, the radiation doses and image quality of both groups were compared using the independent-sample t-test. The radiation doses, and both subjective and objective image quality of the two imaging method were compared through the Kruskal-Wallis test and the Wilcoxon rank-sum test. The independent- or paired-sample t-test was employed to measure inter-group vascular enhanced CT values, as well as signals and noise from regions of interest (ROIs), with signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) calculated. Results:The effective doses of groups A and B were (0.77±0.08) and (0.45±0.05) mSv, respectively, with a statistically significant difference ( t = 21.96, P < 0.001). The vascular enhanced CT values, SDs, SNRs, and CNRs in the arch of the aorta, the initial and bifurcation parts of the common carotid artery, and the M1 segment of the middle cerebral artery showed statistically significant differences among groups A, B1, and B2 ( F = 67.69, 68.50, 50.52, 74.10, 63.10, 91.22, 69.16, P < 0.001). Additionally, statistically significant differences were observed in the subjective scores of image quality among groups A, B1, and B2 ( Z = 71.06, P < 0.05). Conclusions:The DLIR algorithm can further reduce the radiation dose in head and neck CTA examination while significantly reducing image noise and ensuring image quality, thus demonstrating high clinical application value.
3.Level of serum lipoprotein a in patients with diffuse large B-cell lymphoma and its impact on prognosis
Ying ZHU ; Sihong LIU ; Xia WU ; Ming CHEN ; Xiaohui FAN ; Jianxin YAO
Journal of Leukemia & Lymphoma 2024;33(2):91-96
Objective:To investigate the level of serum lipoprotein a [Lp (a)] in patients with diffuse large B-cell lymphoma (DLBCL) and its clinical significance.Methods:A retrospective cohort study was performed. The clinical data of 87 patients with DLBCL who were treated at Changshu No.2 People's Hospital from January 2017 to June 2022 (the newly treated DLBCL group) were retrospectively analyzed, and 78 healthy physical examination subjects were selected as the control group. The level of Lp(a) in the two groups and the level of Lp(a) in DLBCL patients achieving different therapeutic effects after treatment were compared. The receiver operating characteristic (ROC) curve was used to analyze the efficacy of serum Lp(a) in predicting the therapeutic effect of DLBCL patients, and the area under the curve (AUC) was calculated to determine the optimal critical value. Based on the optimal critical value, patients with DLBCL were divided into low Lp(a) group and high Lp(a) group, and the clinicopathological characteristics of DLBCL patients with different Lp(a) levels were compared. Cox proportional hazards model was used to analyze the factors affecting the prognosis of DLBCL patients. Kaplan-Meier method was used to compare the relapse-free survival (RFS) and overall survival (OS) of DLBCL patients with different Lp(a) levels.Results:The level of Lp (a) in the newly treated DLBCL group was higher than that in the control group[ (0.24±0.09) g/L vs. (0.09±0.06) g/L], and the difference was statistically significant ( t = 3.61, P = 0.019). Among 87 patients, 54 achieved complete remission (CR), 23 achieved partial remission (PR), and 10 achieved progression of the disease (PD). The Lp (a) levels of patients achieving CR, PR, and PD were (0.09±0.09) g/L, (0.12±0.08) g/L, and (0.25±0.15) g/L, respectively. The Lp (a) levels in patients achieving CR and PR were lower than those in the newly treated DLBCL patients [(0.24±0.09) g/L], and the differences were statistically significant (all P < 0.05). There was no statistically significant difference in the Lp (a) levels between patients achieving PD and the newly treated DLBCL patients ( P > 0.05). The ROC curve results showed that the optimal critical value of serum Lp (a) in predicting the efficacy of DLBCL patients was 0.25 g/L, AUC was 0.776 (95% CI: 0.676-0.876, P < 0.05), and its sensitivity and specificity was 66.67%, 82.76%, respectively. According to the optimal critical value of Lp (a) (0.25 g/L), patients were divided into the low Lp (a) group (≤ 0.25 g/L) (57 cases) and the high Lp (a) group (>0.25 g/L) (30 cases). The proportion of patients with lactate dehydrogenase level >227 U/L, Ann Arbor stage Ⅲ-Ⅳ, and extranodal organ involvement >1 in the high Lp (a) group was higher than that in the low Lp (a) group, and the differences were statistically significant (all P < 0.05). Cox multivariate analysis results showed that Ann Arbor stage Ⅲ-Ⅳ, international prognostic index (IPI) score 3-5, and Lp (a)>0.25 g/L were independent risk factors for OS in DLBCL patients (all P < 0.05); Ann Arbor stage Ⅲ-Ⅳ and IPI score 3-5 were independent risk factors for RFS in DLBCL patients (all P < 0.05). The median OS in the low Lp (a) group was not reached; the median OS of the high Lp (a) group was 21 months, and there was a statistically significant difference in OS between the two groups ( P = 0.001). The median RFS time was not reached in the low Lp (a) group and the high Lp (a) group; and there was no statistically significant difference in RFS between the two groups ( P = 0.102) . Conclusions:Lp(a) level of DLBCL patients is increased, and Lp(a) could be a factor influencing the prognosis of DLBCL.
4.Death characteristics and trend analysis of malignant tumors in Danjiangkou City in 2015 - 2022
Jianxin WANG ; Yaxue ZHU ; Jing ZHU ; Zhe ZHANG ; Yiran JI ; Yanyan CHEN
Journal of Public Health and Preventive Medicine 2024;35(6):55-58
Objective To investigate the epidemiological characteristics and changing trend of malignant tumor death in Danjiangkou City, the water source area along the middle route of South-to-North Water Diversion Project. Methods The surveillance data of cancer death cases in Danjiangkou City from 2015 to 2022 were collected, and the mortality rate, gender mortality rate, age-specific mortality rate and the rank of cancer cause of death were calculated. Joinpoint regression model was used to analyze the trend of malignant tumor mortality and standardized mortality. Annual percentage change (APC) and average annual percentage change (AAPC) were calculated to analyze the trend changes. Results From 2015 to 2022, a total of 6 254 deaths from malignant tumors were reported in Danjiangkou City, with a crude mortality rate of 178.57/100 000 and a standardized mortality rate of 152.77/100 000. There were 4 366 male deaths, and the crude mortality and standardized mortality were 244.70/100 000 and 212.87/100 000 , respectively. There were 1 888 female deaths, and the crude mortality rate and the standardized mortality rate were 109.89/100 000 and 92.69/100 000, respectively. The crude death rate of malignant tumors in the whole population in Danjiangkou City showed an increasing trend from 2015 to 2022, and the difference was statistically significant (AAPC=5.18%, t=4.07, P<0.05). The crude mortality rates of malignant tumors in both men and women showed an upward trend, and the differences were statistically significant (AAPC =5.56% and 4.35%, both P<0.05). The standardized mortality rates of malignant tumors in the whole population, women and men remained stable, and the differences were not statistically significant (AAPC=0.68, 1.59 and -0.74, all P>0.05). The trend analysis of age-specific mortality of malignant tumors showed that the age-specific mortality of malignant tumors in the whole population, men and women showed an increasing trend with age, and the differences were statistically significant (AAPC =9.22%, 9.40% and 8.53%, P<0.05). The mortality rate of malignant tumors in 0-, 1-, 10-, 45- and 70- age groups decreased year by year (AAPC =-79.62%, -7.19%, -65.99%, -8.88%, and -5.83%, all P<0.05). The mortality rate in the age group of over 75 years old showed an increasing trend (AAPC =12.24%, P<0.05), and the differences were statistically significant. The top 10 malignant tumor deaths in the whole population were lung cancer, gastric cancer, liver cancer, esophageal cancer, colorectal cancer , leukemia , pancreatic cancer , breast cancer , brain malignant tumor and cervical cancer, accounting for 88.49% of all malignant tumor deaths. Mortality rates in lung cancer (AAPC =6.75%), esophageal cancer (AAPC=11.24%), colorectal cancer (AAPC =12.95%), leukemia (AAPC=8.10%), pancreatic cancer (AAPC=15.11%), breast cancer (AAPC=13.11%) and brain malignancies (AAPC=11.16%) showed an increasing trend, and the differences were statistical significant (P<0.05). Conclusion Malignant tumor is the main cause of death in Danjiangkou City. The death rate increases year by year and increases with age. Lung cancer, stomach cancer and liver cancer are the main causes of death. Men and the elderly are high-risk groups of malignant tumors. Early detection and treatment of malignant tumors should be strengthened to reduce the incidence and death.
5.Application value of Nectin-4 targeting radiotracer 68Ga-N188 in the diagnosis of pancreatic cancer
Jianxin WANG ; Yongsu MA ; Weikang LIU ; Xueqi CHEN ; Yiran CHEN ; Yu ZHU ; Jixin ZHANG ; Jianhua ZHANG ; Xing YANG ; Xiaodong TIAN ; Yinmo YANG
Chinese Journal of Digestive Surgery 2024;23(5):746-753
Objective:To investigate the application value of nectin-4 targeting radiotracer 68Ga-N188 in the diagnosis of pancreatic cancer. Methods:The prospective study was conducted. The clinicopathologic data of 16 patients diagnosed as pancreatic cancer on enhanced computed tomography (CT) who were admitted to the Peking University First Hospital from August to December 2022 were collected. There were 9 males and 7 females, aged (62±8)years. All patients underwent 18F-flurodeoxyglucose ( 18F-FDG) and 68Ga-N188 positron emission tomography (PET)/CT examination. Observation indicators: (1) distribution of 68Ga-N188 in different tissues and tumor primary lesion of patients; (2) expression of Nectin-4 and uptake of 68Ga-N188 in pancreatic cancer; (3) comparison of examination results between 68Ga-N188 and 18F-FDG PET/CT. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the independent sample t test. Count data were described as absolute numbers or percentages. Results:(1) Distribution of 68Ga-N188 in different tissues and tumor primary lesion of patients. Results of PET/CT examination showed that in 1 hour after injection, the maximum standard uptake value (SUVmax) and mean standard uptake value (SUVmean) of 68Ga-N188 in fat, muscle, skin, and brain tissues of 16 patients were 0.40±0.16 and 0.25±0.09, 0.68±0.20 and 0.44±0.12, 0.39±0.14 and 0.28±0.11, 0.09±0.04 and 0.05±0.02, respectively. In the tissues of the esophagus, liver, spleen, and pancreas, the above indicators were 1.53±0.48 and 1.16±0.31, 1.49±0.45 and 0.91±0.30, 1.40±0.30 and 1.02±0.24, 1.24±0.31 and 0.96±0.25, respectively. In tumor primary lesion, the above indicators were 3.28±1.02 and 2.14±0.62, respectively, showing significant differences in SUVmax and SUVmean compared with pancreatic tissue ( t=8.03, 6.75, P<0.05). The tumor background ratio in tumor primary lesion based on SUVmax was 1.82±0.58. (2) Expression of Nectin-4 and uptake of 68Ga-N188 in pancreatic cancer. Results of immunohistochemical staining in 16 patients showed that there were 7 patients with high Nectin-4 expression and 9 patients with low Nectin-4 expression. Results of PET/CT examination showed that the SUVmax of 68Ga-N188 in tumor primary lesion of the 7 patients with high Nectin-4 expression and 9 patients with low Nectin-4 expression were 3.77±1.10 and 2.64±0.68, showing a significant difference between them ( t=2.64, P<0.05). The SUVmax of 18F-FDG in tumor primary lesion of the 7 patients with high Nectin-4 expression and 9 patients with low Nectin-4 expression were 6.73±3.24 and 6.43±3.45, showing no significant difference between them ( t=0.17, P>0.05). (3) Comparison of examination results between 68Ga-N188 and 18F-FDG PET/CT. Of the 16 patients, cases with positive results of tumor primary lesion on 68Ga-N188 and 18F-FDG PET/CT were 14 and 11, respectively, for the 14 pancreatic cancer patients diagnosed by postoperative histopathology. Among them, cases with positive results of tumor primary lesion on 68Ga-N188 and 18F-FDG PET/CT were 3 and 1 for the 3 pancreatic cancer patients receiving evaluation for chemotherapy. The SUVmax of 18F-FDG in tumor primary lesion of the 3 patients with chemotherapy and the 11 patients without chemotherapy were 2.80±0.69 and 6.97±2.11, showing a significant difference between them ( t=3.29, P<0.05). The SUVmax of 68Ga-N188 in tumor primary lesion of the 3 patients with chemotherapy and the 11 patients without chemotherapy were 3.38±1.12 and 2.93±0.50, showing no significant difference between them ( t=0.66, P>0.05). Cases with positive results of lymph node metastases in 68Ga-N188 and 18F-FDG PET/CT were 6 and 4, respectively, for the 6 pancreatic cancer patients diagnosed with lymph node metastases by postoperative histopathology, and the SUVmax of 68Ga-N188 and 18F-FDG in lymph node metastases were 2.25±1.12 and 4.02±1.27. Conclusion:68Ga-N188 PET/CT can be used for imaging diagnosis of tumor primary lesion and lymph node metastases of pancreatic cancer.
6.Treatment status of tyrosine kinase inhibitor for newly-diagnosed chronic myeloid leukemia: a domestic multi-centre retrospective real-world study
Xiaoshuai ZHANG ; Bingcheng LIU ; Xin DU ; Yanli ZHANG ; Na XU ; Xiaoli LIU ; Weiming LI ; Hai LIN ; Rong LIANG ; Chunyan CHEN ; Jian HUANG ; Yunfan YANG ; Huanling ZHU ; Ling PAN ; Xiaodong WANG ; Guohui LI ; Zhuogang LIU ; Yanqing ZHANG ; Zhenfang LIU ; Jianda HU ; Chunshui LIU ; Fei LI ; Wei YANG ; Li MENG ; Yanqiu HAN ; Li'e LIN ; Zhenyu ZHAO ; Chuanqing TU ; Caifeng ZHENG ; Yanliang BAI ; Zeping ZHOU ; Suning CHEN ; Huiying QIU ; Lijie YANG ; Xiuli SUN ; Hui SUN ; Li ZHOU ; Zelin LIU ; Danyu WANG ; Jianxin GUO ; Liping PANG ; Qingshu ZENG ; Xiaohui SUO ; Weihua ZHANG ; Yuanjun ZHENG ; Qian JIANG
Chinese Journal of Hematology 2024;45(3):215-224
Objective:To retrospectively analyze the treatment status of tyrosine kinase inhibitors (TKI) in newly diagnosed patients with chronic myeloid leukemia (CML) in China.Methods:Data of chronic phase (CP) and accelerated phase (AP) CML patients diagnosed from January 2006 to December 2022 from 77 centers, ≥18 years old, and receiving initial imatinib, nilotinib, dasatinib or flumatinib-therapy within 6 months after diagnosis in China with complete data were retrospectively interrogated. The choice of initial TKI, current TKI medications, treatment switch and reasons, treatment responses and outcomes as well as the variables associated with them were analyzed.Results:6 893 patients in CP ( n=6 453, 93.6%) or AP ( n=440, 6.4%) receiving initial imatinib ( n=4 906, 71.2%), nilotinib ( n=1 157, 16.8%), dasatinib ( n=298, 4.3%) or flumatinib ( n=532, 7.2%) -therapy. With the median follow-up of 43 ( IQR 22-75) months, 1 581 (22.9%) patients switched TKI due to resistance ( n=1 055, 15.3%), intolerance ( n=248, 3.6%), pursuit of better efficacy ( n=168, 2.4%), economic or other reasons ( n=110, 1.6%). The frequency of switching TKI in AP patients was significantly-higher than that in CP patients (44.1% vs 21.5%, P<0.001), and more AP patients switched TKI due to resistance than CP patients (75.3% vs 66.1%, P=0.011). Multi-variable analyses showed that male, lower HGB concentration and ELTS intermediate/high-risk cohort were associated with lower cytogenetic and molecular responses rate and poor outcomes in CP patients; higher WBC count and initial the second-generation TKI treatment, the higher response rates; Ph + ACA at diagnosis, poor PFS. However, Sokal intermediate/high-risk cohort was only significantly-associated with lower CCyR and MMR rates and the poor PFS. Lower HGB concentration and larger spleen size were significantly-associated with the lower cytogenetic and molecular response rates in AP patients; initial the second-generation TKI treatment, the higher treatment response rates; lower PLT count, higher blasts and Ph + ACA, poorer TFS; Ph + ACA, poorer OS. Conclusion:At present, the vast majority of newly-diagnosed CML-CP or AP patients could benefit from TKI treatment in the long term with the good treatment responses and survival outcomes.
7.Feasibility study of reducing radiation dose of enhanced abdominal examination in 320-row CT using 80 kV tube voltage combined with Karl iterative reconstruction
Jianxin CAO ; Zhuo ZHU ; Wei XU ; Jiashuai LI ; Qing ZHANG
Journal of Practical Radiology 2024;40(7):1170-1174
Objective To explore the feasibility of decreasing radiation dose of enhanced abdominal examination in 320-row CT using 80 kV tube voltage combined with Karl iterative reconstruction.Methods One hundred patients with body mass index(BMI)<25.0 kg/m2 who underwent enhanced abdominal examination in 320-row CT were divided into group A and group B(50 patients for each group).120 kV tube voltage and filtered back projection(FBP)reconstruction were used for group A,while 80 kV tube voltage,FBP recon-struction and Karl iterative reconstruction were used for group B.Radiation dose and image quality between the two groups were evaluated.Results The effective dose(ED)were(11.0±1.7)mSv in group A and(5.6±0.7)mSv in group B for single scan(P<0.01).Compared with group A,the ED in group B was decreased by 49.1%.The noise on the Karl images in group B was significantly decreased compared with the FBP images in group B(P<0.01),and there was no significant difference in noise of liver between the FBP ima-ges in group A and the Karl images in group B(P>0.05).Compared with the FBP images in group A,the noise of abdominal aorta and portal vein on the Karl images in group B was slightly increased(P<0.05),while the signal-to-noise ratio(SNR)and the con-trast-to-noise ratio(CNR)of abdominal aorta and portal vein on the Karl images in group B were significantly increased(P<0.01).Image quality scores for liver,spleen,pancreas,kidney,gastrointestinal tract,abdominal aorta and portal vein on the Karl images in group B were significantly higher than those on the FBP images in group B(P<0.01),and there was no significant difference in the image quality scores for liver,spleen,pancreas,kidney,gastrointestinal tract,and abdominal aorta between the FBP images in group A and the Karl images in group B(P>0.05),while the image quality score for portal vein on the Karl images in group B was higher than that on the FBP images in group A(P<0.05).Conclusion Radiation dose can be decreased obviously in 320-row CT enhanced abdominal examination using 80 kV tube voltage combined with Karl iterative reconstruction for the patients with BMI<25.0 kg/m2,while image quality can be maintained for diagnosis.
8.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
9.Key elements in establishing fetal growth standards representative of the Chinese population
Jianxin ZHAO ; Yanping WANG ; Luming SUN ; Jun ZHU
Chinese Journal of Perinatal Medicine 2024;27(9):705-709
As a commonly used tool in obstetrics, fetal growth curves play an important role in screening for small for gestational age infants and predicting fetal growth restriction. However, a high-quality fetal growth standard curve based on the Chinese population has not yet been established. Compared to fetal growth reference values, fetal growth standards have higher requirements. This article discusses several key elements in establishing fetal growth standards in China, including the selection of research sites, the inclusion of low-risk pregnant women, the implementation of longitudinal study, the determination of sample size, the standardization of measurements, and quality control, aiming to ensure the scientific validity and accuracy of the fetal growth standards.
10.Application of one-beat acquisition with wide detector CT in coronary artery CT angiography of patients with atrial fibrillation
Shumeng ZHU ; Xing LI ; Xiaoqian JIA ; Qian TIAN ; Zhefan SONG ; Tingting QU ; Le CAO ; Jianxin GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2023;44(6):977-982
【Objective】 To evaluate the effect of one-beat acquisition with wide detector CT on the image quality and diagnostic efficiency of coronary CT angiography (CCTA) in patients with atrial fibrillation. 【Methods】 A total of 52 consecutive patients with atrial fibrillation, including 31 males, (67.32±11.45) years old, who underwent CCTA from July 2022 to February 2023, were analyzed retrospectively. All patients underwent one-beat acquisition CCTA. The subjective and objective image quality of the coronary arteries was evaluated, and using invasive coronary catheter angiography as the gold standard, the diagnostic efficacy of stenosis degrees above moderate and severe degrees was calculated, respectively. 【Results】 Subjective evaluation results: 92.31% (384/416) of the vascular segments were rated as excellent or good, and the diagnosable rate reached 98.08% (408/416, subjective score ≥3 points). Objective evaluation results: The CT value of the right coronary artery, anterior descending branch, and circumflex branch was (433.41±95.17)HU, (422.69±92.81)HU and (420.27±95.43)HU, respectively; the contrast-to-noise ratio was 38.46±7.54, 32.46±13.78 and 37.74±8.89, respectively. The total diagnostic accuracy, sensitivity, and specificity was 94.71%, 87.9% and 96.62%, respectively, for moderate stenosis and 96.15%, 83.64% and 98.06% for severe stenosis. 【Conclusion】 One-beat acquisition with wide detector CT can obtain high-quality coronary artery images and high diagnostic accuracy for patients with atrial fibrillation without radiation dose increase to patients. It has good clinical application value for patients with atrial fibrillation.


Result Analysis
Print
Save
E-mail