1.The value of three-point localization method for four-chamber view acquisition in cardiac magnetic resonance imaging
Lihong CHEN ; Tingting QU ; Le CAO ; Yanan LI ; Ganglian FAN ; Bing LIU ; Zhijie JIAN ; Jianxin GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(3):491-496
Objective To evaluate the application value of the three-point localization method in improving the quality and efficiency of four-chamber view acquisition in cardiac magnetic resonance(CMR)imaging.Methods A total of 215 patients who underwent four-chamber view in CMR imaging from January 2022 to October 2023 were retrospectively enrolled and divided into two groups.The control group(n=109)received traditional localization method while the study group(n=106)received three-point localization method.The image quality of mitral valve,tricuspid valve and cruciform structure in four-chamber view images were assessed by two radiologists using a Likert 4-piont scale.The time-consumption from scout imaging to the finish of four-chamber view imaging was recorded.Constituent data and numeral data were compared by Chi-square test and two-sample t test,respectively.Kappa test was used to analyze the inter-observer consistency.Results There were no significant inter-group differences in gender,age,disease profile,or the radiographers'experience.The mean quality scores of the mitral valve,tricuspid valve and cruciform structure in the control group and the study group were 3.44±0.64 and 3.63±0.49(P=0.023),3.43±0.67 and 3.53±0.60(P=0.202),3.71±0.49 and 3.83±0.35(P=0.047),respectively.The image quality score was higher in the study group than in the control group,with the differences in mitral valve and cruciform structure reaching statistical significance.The time-consumption for obtaining four-chamber view for the control group and the study group was 11.67±3.49 minutes and 7.212±1.83 minutes,respectively,with statistically significant differences(P<0.001).Conclusion Compared with the traditional localization method,the three-point localization method provides better image quality in four-chamber view imaging with shortened imaging time.
2.Analysis of factors affecting the detection of urinary stone using virtual unenhanced images derived from dual-energy CTU
Yannan CHENG ; Yanan LI ; Jingtao SUN ; Qian TIAN ; Jian YANG ; Wei TONG ; Jian YANG ; Jianxin GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(4):535-541
Objective To evaluate the factors affecting urinary stone detection rate using virtual unenhanced(VUE)images obtained from triphasic dual-energy CT urography(DECTU)based on Logistic regression analysis.Methods For this study,150 patients who had suspected urinary stone and underwent triphasic DECTU were included.The true unenhanced(TUE)images were reconstructed as 120 kVp-like images,and VUE images at the portal venous phase[VUE(VP)]and excretory phase[VUE(EP)]were obtained using iodine removal technique from portal venous and excretory phase DECTU images,respectively.Two readers independently evaluated the above three types of images,and recorded the number of urinary stones,their anatomical locations,and whether there was residual iodine on the VUE images.Stone size and CT number were recorded only on the TUE images.Stone size,CT number,anatomical location,and iodine contrast agent were included in univariate and multivariate Logistic regression analyses to evaluate the factors affecting urinary stone detection rate using VUE images.Thresholds for detecting urinary stones on VUE images were determined using receiver operating characteristics(ROC)analysis.Results We detected 304 stones on TUE images,while the detection rates were 92.4%and 71.4%when using VUE(VP)and VUE(EP)images,respectively.Stone size and CT number were important factors influencing urinary stone detection rate using VUE(VP)and VUE(EP)images(P<0.01).The area under curve(AUC)of using stone size and CT number for detecting stones using the VUE(VP)images was up to 0.96,and as threshold values,stones with size larger than 3.52 mm and CT number greater than 469 HU were found to have high accuracy.However,the AUC decreased to 0.88 when we combined stone size,CT number and anatomical location using the VUE(EP)images.In addition,different contrast agents did not affect the detection rate of stones on the VUE(EP)images(P=0.57).The stone detection rate in the kidney was significantly lower than those on the VUE(EP)images(P<0.001).Conclusion VUE(VP)images provide better stone detection.Stone size and CT number have significant impacts on the stone detection rate using VUE images.The lower stone detection rate in the kidney on the VUE(EP)images is related to the residual iodine.
3.The value of abdominal aorta combined with routine one-stop TRO-CTA examination in the management of patients with acute chest pain
Tingting QU ; Le CAO ; Yanan LI ; Lihong CHEN ; Ganglian FAN ; Yannan CHENG ; Yinxia GUO ; Jianxin GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(4):542-546
Objective To investigate the value of abdominal aortic combined with routine one-stop triple rule-out computed tomography angiography(TRO-CTA)in the examination of patients with acute chest pain.Methods A total of 1 482 patients with nontraumatic chest pain were included in this retrospective study.Of them 414 patients underwent the conventional TRO-CTA scanning while 1 068 patients underwent TRO-CTA that included the abdominal aorta(TRO-CTAwAA)under the request of clinicians.All scanning parameters were the same,except the scanning range for the third phase in TRO-CTA:conventional TRO-CTA covered only the thoracic aorta,while TRO-CTAwAA extended to the entire aorta.Patient etiology was investigated and the detection rates of major vessel abnormalities(aortic dissection,aneurysm,penetrating ulcer,intramural hematoma,vascular occlusion,and thrombosis)between the two groups was compared using chi square tests.The radiation dose(CTDIvol and DLP)and scanning time between the two groups were compared using analysis of variance(ANOVA).Results The TRO-CTAwAA had significantly higher detection rate of major artery abnormalities than the TRO-CTA group(35.1%vs.4.8%,P<0.001).In the TRO-CTAwAA group,26.5%of the vascular anomalies were detected in both the thoracic and abdominal aortas,and another 8.6%were seen only in the abdominal aorta.With regard to the radiation dose between the two groups,the total DLP was significantly higher in the TRO-CTAwAA group than in the conventional TRO-CTA group(P<0.001).The two groups did not significantly differ in scanning time(P=0.410).Conclusion TRO-CTA with scan range including the abdominal aorta significantly improves the detection rate for major vessel abnormalities in patients with chest pain without increasing the examination process.
4.Correlation between the pericoronary fat attenuation index and the CT image reconstruction parameters
Lihong CHEN ; Gongting CHEN ; Ganglian FAN ; Yanan LI ; Tingting QU ; Le CAO ; Zhijie JIAN ; Jianxin GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(4):547-551
Objective To evaluate the relationship between the pericoronary fat attenuation index(FAI)and the image reconstruction parameters of computed tomography(CT)coronary angiography,including reconstruction kernel,iterative reconstruction algorithm and image thickness.Methods Forty-four CT coronary angiography scans were prospectively enrolled.All scans were reconstructed by three means as follows:① Four different kernels(Soft_AA,Soft_BA,Soft_CA,and Soft_DA,sharpness from low to high)as the iterative reconstruction algorithm(KARL5)and image thickness(0.5 mm)remained unchanged.② Filtered back projection(FBP)and iterative reconstruction kernel(KARL5)as the kernel and image thickness(0.5 mm)remained unchanged.③ Different image thickness(0.5 mm and 1 mm)as the kernel(Soft_AA)and iterative reconstruction algorithm(KARL5)remained unchanged.The FAI of left anterior descending artery(LAD),left circumflex artery(LCX),and right coronary artery(RCA)was calculated using a dedicated software.Paired t-test and analysis of variance were used for statistical analysis.Results For LAD,LCX and RCA:① The differences of FAI among different reconstruction kernels reached statistical significance(P<0.001),and FAI decreased as the sharper kernel was used.③ Compared with FBP,the FAI of KARL5-reconstructed images significantly increased(P<0.001).③ Compared with 0.5 mm,the FAI of images with 1.0 mm thickness significantly decreased(P<0.001).Conclusion The kernel,iterative reconstruction algorithms,and image thickness all have a significant impact on the FAI of each coronary artery.When using FAI for clinical diagnosis,the effect of CT reconstruction parameters should be taken into account.
5.Treatment status of tyrosine kinase inhibitor for newly-diagnosed chronic myeloid leukemia: a domestic multi-centre retrospective real-world study
Xiaoshuai ZHANG ; Bingcheng LIU ; Xin DU ; Yanli ZHANG ; Na XU ; Xiaoli LIU ; Weiming LI ; Hai LIN ; Rong LIANG ; Chunyan CHEN ; Jian HUANG ; Yunfan YANG ; Huanling ZHU ; Ling PAN ; Xiaodong WANG ; Guohui LI ; Zhuogang LIU ; Yanqing ZHANG ; Zhenfang LIU ; Jianda HU ; Chunshui LIU ; Fei LI ; Wei YANG ; Li MENG ; Yanqiu HAN ; Li'e LIN ; Zhenyu ZHAO ; Chuanqing TU ; Caifeng ZHENG ; Yanliang BAI ; Zeping ZHOU ; Suning CHEN ; Huiying QIU ; Lijie YANG ; Xiuli SUN ; Hui SUN ; Li ZHOU ; Zelin LIU ; Danyu WANG ; Jianxin GUO ; Liping PANG ; Qingshu ZENG ; Xiaohui SUO ; Weihua ZHANG ; Yuanjun ZHENG ; Qian JIANG
Chinese Journal of Hematology 2024;45(3):215-224
Objective:To retrospectively analyze the treatment status of tyrosine kinase inhibitors (TKI) in newly diagnosed patients with chronic myeloid leukemia (CML) in China.Methods:Data of chronic phase (CP) and accelerated phase (AP) CML patients diagnosed from January 2006 to December 2022 from 77 centers, ≥18 years old, and receiving initial imatinib, nilotinib, dasatinib or flumatinib-therapy within 6 months after diagnosis in China with complete data were retrospectively interrogated. The choice of initial TKI, current TKI medications, treatment switch and reasons, treatment responses and outcomes as well as the variables associated with them were analyzed.Results:6 893 patients in CP ( n=6 453, 93.6%) or AP ( n=440, 6.4%) receiving initial imatinib ( n=4 906, 71.2%), nilotinib ( n=1 157, 16.8%), dasatinib ( n=298, 4.3%) or flumatinib ( n=532, 7.2%) -therapy. With the median follow-up of 43 ( IQR 22-75) months, 1 581 (22.9%) patients switched TKI due to resistance ( n=1 055, 15.3%), intolerance ( n=248, 3.6%), pursuit of better efficacy ( n=168, 2.4%), economic or other reasons ( n=110, 1.6%). The frequency of switching TKI in AP patients was significantly-higher than that in CP patients (44.1% vs 21.5%, P<0.001), and more AP patients switched TKI due to resistance than CP patients (75.3% vs 66.1%, P=0.011). Multi-variable analyses showed that male, lower HGB concentration and ELTS intermediate/high-risk cohort were associated with lower cytogenetic and molecular responses rate and poor outcomes in CP patients; higher WBC count and initial the second-generation TKI treatment, the higher response rates; Ph + ACA at diagnosis, poor PFS. However, Sokal intermediate/high-risk cohort was only significantly-associated with lower CCyR and MMR rates and the poor PFS. Lower HGB concentration and larger spleen size were significantly-associated with the lower cytogenetic and molecular response rates in AP patients; initial the second-generation TKI treatment, the higher treatment response rates; lower PLT count, higher blasts and Ph + ACA, poorer TFS; Ph + ACA, poorer OS. Conclusion:At present, the vast majority of newly-diagnosed CML-CP or AP patients could benefit from TKI treatment in the long term with the good treatment responses and survival outcomes.
6.Case report on Niemann-Pick disease type C with diffuse interstitial lung disease as the initial manifestation due to NPC1 gene mutation
Siyuan GUO ; Jun LIU ; Jianxin HE ; Baoping XU
Chinese Journal of Applied Clinical Pediatrics 2024;39(12):940-942
The clinical data of a case of Niemann-Pick disease type C diagnosed at Beijing Children′s Hospital, Capital Medical University on December 22, 2017 were retrospectively analyzed.The patient, male, 1 year and 28 days old, was admitted to the hospital primarily due to intermittent fever, cough and dyspnea for 8 months, and hepatosplenomegaly for 20 days.The patient initially presented with cough, expectoration, and wheezing, followed by hypotonia and delayed motor development.At the age of 1 year, the child developed hepatosplenomegaly and diffuse interstitial changes in both lungs.At the age of 3 years, the child had obvious vertical supranuclear gaze palsy and gelastic cataplexy, followed by dysarthria and dysphagia.The foam cells were found by bone marrow cytology, while sphingomyelinase and glucocerebrosidase were normal, so Niemann-Pick disease type A/B and Gaucher disease were excluded.Finally, genetic testing revealed two pathogenic mutations in the NPC1 gene, so Niemann-Pick disease type C was confirmed.Miglustat treatment began when the child was 3 years old, and vertical supranuclear gaze palsy and gelastic cataplexy improved for a while, but then the neurological symptoms worsened again, with dysphagia and dyspnea gradually increasing, and finally he died at the age of 4 years and 11 months.
7.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
8.Study on deep learning reconstruction algorithm to improve image quality in low dose abdominal and pelvic CT angiography
Tingting QU ; Le CAO ; Yannan CHENG ; Lihong CHEN ; Yanan LI ; Yinxia GUO ; Jianying LI ; Jian YANG ; Jianxin GUO
Chinese Journal of Radiology 2024;58(6):647-652
Objective:To investigate the practicality of TrueFidelity deep learning reconstruction algorithm in low-dose abdominal and pelvic CT angiography (CTA).Methods:The patients who required abdominal and pelvic CTA were prospectively included at the First Affiliated Hospital of Xi′an Jiaotong University from June 2020 to March 2021. All patients underwent low-dose CTA with a tube voltage of 80 kV and smart tube current modulation (100-720 mA). Images were reconstructed using the traditional FBP, adaptive statistical iterative reconstruction with a strength of 50% (ASIR-V 50%), TrueFidelity with medium (TF-M) and high (TF-H) strength. The CT value and standard deviation (SD value) of the abdominal aorta, psoas major muscle and subcutaneous fat in the same layer were measured, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated. We also introduced the measurement of skewness of CT value in psoas major muscle with uniform density. The above indexes of the four groups of reconstructed images were compared. A 5-point scoring method was used to evaluate the granularity, fuzziness and beam-hardening artifacts of all images. Objective measurement indicators, such as CT values, were tested by repeated measure ANOVA with the Bonferroni post hoc test.Results:There were forty-six patients in the study. The volume CT dose index of the scan was low at (1.09±0.31)mGy. There was no significant difference in CT values of vessels and muscles between the four groups ( P>0.05), but there was a significant difference in SD value( P<0.001). The SD value of the FBP group was the largest and that of the TF-H group was the smallest. The difference between SNR and CNR was statistically significant ( P<0.001), and the overall trend was opposite to that of the SD value. There was no significant difference in the skewness between the four groups. The granularity score of the FBP group was the largest, that of the TF-H group was the smallest, and there was a significant difference among the four groups. The score of fuzziness in the TF-H group was slightly higher than that in the other three groups, but there was no significant difference. The beam-hardening artifact score of FBP and ASIR-V 50% group was the worst, and the TF-H group was the best ( P<0.001). Conclusions:Compared with FBP and ASIR-V, TrueFidelity reconstruction algorithm provides better image quality (comprehensively considering image noise, fuzziness, uniformity, and hardening artifacts) in low-dose CT scanning of abdominal and pelvic vessels, and TF-H has the best image quality.
9.Dosimetric and radiobiological differences in three radiotherapy techniques of whole breast irradiation with simultaneous integrated boost
Jiming YANG ; Hang CHENG ; Rui HU ; Xuhao DAI ; Yong WU ; Pengrong LOU ; Jianliang ZHOU ; Jianxin GUO ; Jiangping REN
Chinese Journal of Radiological Medicine and Protection 2024;44(9):764-770
Objective:To identify the dosimetric and radiobiological differences of three radiotherapy techniques of whole breast irradiation with simultaneous integrated boost (WBI-SIB) following breast-conserving surgery for early breast cancer (EBC).Methods:The data of 20 patients with early left-sided breast cancer who received radiotherapy following breast-conserving surgery were retrospectively analyzed. Three radiotherapy techniques, namely hybrid intensity-modulated radiotherapy (HIMRT), intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT), were redesigned with the same prescription dose and target conditions. Then, doses to target volume (TV) and organs at risk (OAR), along with the normal tissue complication probability (NTCP) and secondary cancer risk (SCR) for specific organs, were compared.Results:Compared to HIMRT and IMRT, VMAT led to significant decreases in various dosimetric indices of the affected lung and heart and increases in the Dmean doses to the healthy lung and healthy breast and V5 Gy doses to the healthy breast, with the differences being significantly different ( P < 0.05). The average NTCP values of cardiac death, radiation pneumonitis, and pulmonary fibrosis induced by VMAT were 0.41%, 1.62%, and 23.59%, respectively, significantly lower than those caused by other two techniques ( P < 0.05). No statistical differences were found in 10 dosimetric indices of OAR between IMRT and HIMRT, while the NTCP analysis suggested that the risks of cardiac death ( t = 2.70, P < 0.05) and pulmonary fibrosis ( t =4.11, P < 0.05) induced by IMRT were slightly lower than those caused by HIMRT. In addition, the excess absolute risk (EAR) to the healthy lung posed by VMAT was 1.65 and 1.83 times those induced by HIMRT and IMRT, respectively ( z = -3.92, t = -6.43, P < 0.05). In contrast, the EAR to the healthy breast induced by VMAT was 2.79 and 2.65 times those posed by HIMRT and IMRT, respectively ( z = -3.21, -3.70, P < 0.05). Conclusions:Among three intensive-modulated radiotherapy techniques of WBI-SIB for EBC, VMAT provides the optimal protection for the heart and affected lung but leads to the highest SCR to the healthy lung and breast. When VMAT is employed for young EBC patients or those with normal cardiopulmonary function, special attention should be paid to reducing low-dose irradiations to the healthy breast and thereby minimizing SCR. In contrast, VMAT might be more favorable for patients with pronounced cardiopulmonary risks or aged patients.
10.Effectiveness and safety of laparoscopic-assisted liposuction for treatment of gynaecomastia
Zhiqiang MA ; Jianxin HE ; Ruonan WANG ; Wei GUO ; Mengyuan CHEN ; Hai LU ; Bingshuai SHI
Chinese Journal of Medical Aesthetics and Cosmetology 2024;30(5):501-505
Objective:To explore the effectiveness and safety of laparoscopic-assisted liposuction in the treatment of gynecomastia.Methods:A retrospective study was conducted on 115 male breast development patients from January 2021 to May 2023 at the First Affiliated Hospital of Henan University and Shaoguan Hospital of Southern Medical University. The patients were divided into two groups based on surgical methods: the laparoscopic combined liposuction technique group (observation group) and the traditional areola incision group (control group). The control group consisted of 59 cases, aged between 18 and 52 years (26.2±5.2); There were 56 cases in the observation group, aged between 18 and 55 years (26.5±5.2). The differences in surgical time, intraoperative blood loss, drainage tube removal time, incidence of surgical complications, postoperative drainage volume, pain visual analog scale (VAS), and patient satisfaction were compared between two groups of patients.Results:The intraoperative bleeding volume, drainage tube removal time, and postoperative drainage volume in the observation group were 12.25±2.23, 2.85±0.53, and 80.52±7.53, respectively, all of which were lower than those in the control group (26.53±2.35, 4.22±0.59, 81.25±8.54, respectively), and the differences were statistically significant (all P<0.05).The incidence of sensory abnormalities in the nipple areola area of the observation group was 1.8% (1/56), which was lower than the 10.2% (6/59) of the control group, and the difference was statistically significant ( P<0.05).The postoperative breast shape, nipple shape, and incision score of the observation group were 81.15±18.52, 77.85±22.15, and 72.58±10.56 points, respectively, all higher than the control group's 69.34±18.48, 78.12±21.75, and 60.35±9.35 points, and the differences were statistically significant (all P<0.05). Conclusions:Laparoscopic combined with liposuction technology for the treatment of gynecomastia can reduce intraoperative bleeding and postoperative drainage volume and shorten the time for removing drainage tubes with better safety.

Result Analysis
Print
Save
E-mail