1.Guidelines for Establishing Animal Models of Rheumatoid Arthritis with Cold-dampness Obstruction Syndrome and Dampness-heat Obstruction Syndrome
Na LIN ; Yanqiong ZHANG ; Changhong XIAO ; Shenghao TU ; Jianning SUN ; Shijun XU ; Representation Preparation GROUP
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):47-54
Rheumatoid arthritis belongs to arthralgia syndrome in the theory of traditional Chinese medicine, and cold-dampness obstruction syndrome and dampness-heat obstruction syndrome are core syndromes and main syndrome differentiation types of this disease. Fine therapeutic effects have been obtained in the long-term clinical practice of many famous traditional Chinese medicine practitioners following the syndrome differentiation and treatment based on the guiding principles of cold and heat. To adapt to the clinical diagnosis practice of combining disease differentiation and syndrome differentiation, and to better carry out basic research on integrated Chinese and Western medicine and preclinical study on new traditional Chinese medicines, Guidelines for Establishing Animal Models of Rheumatoid Arthritis with Cold-Dampness Obstruction Syndrome and Dampness-Heat Obstruction Syndrome (hereinafter referred to as the Guidelines) were compiled by our research group, in cooperation with the renowned experts in research fields including traditional Chinese medicine, clinical medicine, zoology and evidence-based medicine, which provide a meaningful reference for scientific research, teaching and clinical applications. The compilation process of the Guidelines was guided by the theory of disease and syndrome integration and the principles of "evidence takes the main place, consensus plays an auxiliary role, and experience serves as the reference". Based on the comprehensive evaluation of pathogenesis homology, behavioral phenotypic consistency, and drug treatment predictability compared between animal models and human diseases, by the nominal group method, "recommendations" were formed for recommendations supported by evidence, and "consensus recommendations" were formed for recommendations not supported by evidence. Guidelines were formed involving content such as animal types, arthritis modeling methods, external stimulation conditions, and modeling assessment indicators during the establishment of the animal models of rheumatoid arthritis with cold-dampness obstruction syndrome and dampness-heat obstruction syndrome. The Guidelines are applicable for the disease and syndrome research on rheumatoid arthritis, investigation of therapeutic mechanisms, and development of new traditional Chinese medicine. The Guidelines also provide a reference for the establishment of guidelines on other types of diseases and syndromes combined with animal models to further promote the modernization of traditional Chinese medicine research and its integration with international academic development.
2.Editorial Explanation of Guidelines for Establishing Animal Models of Rheumatoid Arthritis with Cold-dampness Obstruction Syndrome and Dampness-heat Obstruction Syndrome
Na LIN ; Yanqiong ZHANG ; Changhong XIAO ; Shenghao TU ; Jianning SUN ; Shijun XU ; Xia MAO ; Representation Preparation GROUP
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):55-59
The Guidelines for Establishing Animal Models of Rheumatoid Arthritis with Cold-dampness Obstruction Syndrome and Dampness-heat Obstruction Syndrome (hereinafter referred to as the Guidelines) (No. T/CACM1567-2024) was published by Chinese Association of Chinese Medicine on January 11, 2024. To assist researchers and medical workers in understanding and applying the Guidelines more accurately, and also to provide reference and assistance for the establishment of guidelines on other types of diseases and syndromes combined with animal models, this paper made a declaration of the workflow, technological links, development references, promotion of its application and after-effect evaluation of the Guidelines that has been made according to the requirements of "Draft Group Standard of the Standardization Office of the Chinese Association of Traditional Chinese Medicine".
3.NAD+ Ameliorates Endothelial Dysfunction in Hypertension via Activation of SIRT3/IDH2 Signal Pathway
Yumin QIU ; Xi CHEN ; Jianning ZHANG ; Zhangchi LIU ; Qiuxia ZHU ; Meixin ZHANG ; Jun TAO ; Xing WU
Journal of Sun Yat-sen University(Medical Sciences) 2025;46(1):70-80
ObjectiveTo investigate the effect of nicotinamide adenine dinucleotide on vascular endothelial injury in hypertension and its molecular mechanism. MethodsC57BL/6J mice were randomly divided into saline group (Saline) and hypertension group (Ang Ⅱ, which were infused with Ang Ⅱ via subcutaneously implanted osmotic pumps), and supplemented daily with nicotinamide mononucleotide (300 mg/kg), a precursor of NAD+. Blood pressure, endothelial relaxation function and pulse wave velocity were measured after 4 weeks. Wound healing assay and adhesion assay were used to evaluate the function of endothelial cells in vitro. mtROS levels were detected by immunofluorescence staining. RT-PCR was used to detect the mRNA expression of mtDNA, SIRT3 and isocitrate dehydrogenase 2 (IDH2). 8-hydroxy-2'-deoxyguanosine levels were detected by enzyme-linked immunosorbent assay. The protein expression levels of p-eNOS, eNOS, SIRT3 and IDH2 were detected by Western blot. ResultsNMN supplementation reduced blood pressure (P<0.001) and improved endothelial function and arterial stiffness (P<0.001) in hypertensive mice. In vitro, NMN improved endothelial function in AngII-stimulated endothelial cells (P<0.05) and attenuated mitochondrial oxidative stress levels (P<0.001). Mechanistically, NMN elevated SIRT3 activity (P<0.001), which subsequently enhanced IDH activity (P<0.001) and reduced oxidative stress levels in endothelial cells. Conversely, knockdown of IDH2 would reverse the effect of SIRT3 in improving endothelial function (P<0.001). ConclusionNAD+ lowers blood pressure and enhances vascular function in hypertension by reducing the level of oxidative stress in endothelial cells through activation of the SIRT3/IDH2 signal pathway.
4.Biomechanical analysis of calcaneal sustentaculum tail sustentacular screw in treatment of Sanders type Ⅱ fractures
Guangsheng TANG ; Qi WANG ; Yao XU ; Bing WANG ; Jianning SUN ; Deguang WANG
International Journal of Biomedical Engineering 2024;47(5):449-456
Objective:To construct a finite element analysis model for the application of sustentaculum tail sustentacular screw in the treatment of calcaneal fracture of Sanders type Ⅱ. The finite element analysis method was used to study the effectiveness of the simulation treatment of Sanders type Ⅱ calcaneal fracture.Methods:A complete adult calcaneal specimen that was not affecting the normal quality of bone after teaching in the Department of Human Anatomy, Kangda College of Nanjing Medical University from 2021 to 2022 second semester was selected. A micro CT scan was performed to obtain data. The three-dimensional model of the calcaneus was reconstructed by the software of Mimics and Geomagic Wrap. The internal fixation and fracutre model were drawn using SolidWorks software. The obtained data were imported into the finite element analysis software for material assignment and meshing to obtain a three-dimensional finite element model. The load and boundary constraints were applied to each model to perform finite element analysis and calculation, and the stress and displacement of the model were extracted. Finally, the experimental screw placement of the calcaneus loading process was verified.Results:The three-dimensional model of calcaneal fracture had a high degree of appearance simulation, complete morphological structure, no defect, and was consistent with the size of the solid calcaneus. After surgical treatment, the anatomical reduction of each fracture model was good, the steel plate fit to the bone surface, and the screw did not protrude outside the model. There was no deformation or damage to the whole internal fixation, the grid division was clear, and the number was relatively uniform and consistent. The maximum stress in each type of calcaneal fracture model was in the internal fixation, and the overall stress was uniformly distributed in each component. The maximum displacement distance of each type of calcaneal fracture was less than 0.13 mm, and the angles and lengths of nails were accurate. The tip of the Kirschner wires was located in the sustentaculum tail. There was no rupture of the sustentaculum tali and no protrusion of the Kirschner wires.Conclusions:The internal fixation is an effective method to treat the Sanders type Ⅱ calcaneal fractures by using sustentaculum tail sustentacular screws.
5.Proximal tibial lateral locking plate with rafting screws combined with Jail screws in the treatment of collapse fracture of the lateral tibial plateau
Xiangru KONG ; Chun YANG ; Yuzhou SHAN ; Jianning SUN ; Wei JIANG ; Taiming YANG ; Yucheng ZHU
Chinese Journal of Trauma 2022;38(6):510-516
Objective:To explore the efficacy of the proximal tibial lateral locking plate with rafting screws combined with Jail screws in the treatment of collapse fracture of the lateral tibial plateau.Methods:A retrospective case series study was performed on clinical data of 36 patients with collapse fracture of the lateral tibial plateau admitted to Suqian Hospital of Nanjing Drum Tower Hospital Group from January 2016 to January 2020, including 19 males and 17 females, aged 34-68 years [(48.6±5.8)years]. Schatzker classification was type II in 28 patients and type III in 8 patients. All patients were treated using the proximal tibial lateral locking plate with raft screws combined with Jail screws. The operation time, intraoperative blood loss and fracture healing were detected. The distance of articular surface collapse of the tibial plateau, posterior inclination angle (PSA) of the tibial plateau, tibial plateau varus angle (TPVA) and Rasmussen anatomical score were compared before operation and at day 2 and 1 year after operation. The Hospital for Special Surgery (HSS) score was used to evaluate knee function at day 2 and 1 year after operation. Complications were also recorded.Results:All patients were followed up for 12-32 months [(19.5±3.1)months]. The operation time was 56-82 minutes [(68.5±9.1)minutes]. The intraoperative blood loss was 40-100 ml [(75.6±10.2)ml]. The fracture was clinically healed by first-stage, with the healing time of 8 to 15 weeks [(12.5±1.3)weeks]. The distance of articular surface collapse of the tibial plateau was improved from (15.5±4.2)mm before operation to (0.7±0.3)mm at day 2 after operation and (1.0±0.2)mm at 1 year after operation (all P<0.01). The PSA was improved from (21.2±2.1)° before operation to (8.9±0.8)° at day 2 after operation and (9.2±0.6)° at 1 year after operation (all P<0.01). The TPA was improved from (100.2±3.7)° before operation to (88.9±1.8)° at day 2 after operation and (87.2±1.6)° at 1 year after operation (all P<0.05). The Rasmussen anatomical score changed from (7.8±1.8)points before operation to (17.1±0.9)points at day 2 after operation and (16.3±0.7)points at 1 year after operation (all P<0.01). There were no significant difference in the distance of articular surface collapse of the tibial plateau, PSA, TPVA and Rasmussen anatomical score at day 2 and 1 year after operation (all P>0.05). The HSS score was (92.8±3.2)points at 1 year after operation, significantly higher than (74.8±3.5) points at day 2 after operation ( P<0.01). Two patients sustained superficial wound infection after operation, which healed after debridement and dressing change. No deep infection occurred. Conclusion:For patients with collapse fracture of the lateral tibial plateau, the proximal tibial lateral locking plate with rafting screws combined with Jail screws can effectively prevent secondary collapse of the articular surface and obtain satisfactory anatomical reduction, good functional recovery and few postoperative complications.
6.Effects of polydopamine-coated porous titanium alloy scaffolds loaded with zoledronic acid-gelatin nanoparticles for topical sustained drug release on osteoclasts: an in vitro study
Xiaojiang YANG ; Guojing SUN ; Weidi YAN ; Zhenfang WU ; Yunfan TI ; Jingwei LU ; Jianning ZHAO
Chinese Journal of Orthopaedic Trauma 2022;24(7):617-623
Objective:To analyze the effects of a novel type of polydopamine (PDA)-coated porous titanium alloy scaffolds loaded with zoledronic acid-gelatin nanoparticles (ZOL-GNPs) for topical sustained drug release on osteoclasts in vitro. Methods:After porous titanium alloy scaffolds were fabricated using electron beam melting technique and ZOL-GNPs with different ZOL concentrations (0, 1, 10, 50, 100, 500 μmol/L) were prepared by desolvation method, PDA-coated porous titanium alloy scaffolds loaded with ZOL-GNPs were constructed by combining the two. The characteristics of the scaffolds were analyzed. The biomechanics of 3 different scaffolds (bare porous titanium alloy scaffolds, PDA-coated porous titanium alloy scaffolds, and PDA-coated porous titanium alloy scaffolds loaded with ZOL-GNPs) were investigated. Drug release detection was carried out by high performance liquid chromatography on the 1st, 4th, 7th, 14th, 21st, and 28th days respectively. The osteoclasts were inoculated into the novel scaffolds with different ZOL concentrations. The expression of osteoclast-related genes was detected by real-time quantitative (RT)-polymerase chain reaction (PCR); the expression of osteoclast-related proteins was detected by Western-blot.Results:The PDA-coated porous titanium alloy scaffolds loaded with ZOL-GNPs were successfully constructed. Electron microscope scanning showed that the GNPs were well spheroidized, smooth in surface, and uniformly dispersed, with a particle size of (243.6±63.4) nm. The ZOL-GNPs were uniformly compounded on the surface and in the pores of the scaffolds, and the spheres were regular in shape with no adhesion. The biomechanical experiments showed that the elastic moduli of the porous titanium alloy scaffolds under 3 different conditions were (1.81±0.12) GPa, (1.80±0.23) GPa and (1.81±0.15) GPa, showing no significant difference ( P> 0.05). The drug release percentage in the porous titanium alloy scaffolds was obviously high on the first day, and increased gradually and slowly in the subsequent 27 days. In the scaffolds with a low concentration ZOL, more osteoclasts adhered and proliferated; in the 50 μmol/L scaffolds, spheroid cells appeared; the spheroid cells increased and even apoptosis occurred with an increase in the ZOL concentration. RT-PCR showed that the expression of Ctsk gene and TRAP gene increased with the increased ZOL concentration, peaked in the 50 μmol/L scaffolds, and then decreased with the increased concentration, showing statistically significant differences ( P < 0.05). Western-blot showed that the expression pattern of Ctsk and TRAP was similar to that of their related genes. Conclusions:The novel PDA-coated porous titanium alloy scaffolds loaded with ZOL-GNPs demonstrate good mechanical properties and an anti-osteoporosis effect via their topical sustained drug release. The scaffolds with a ZOL concentration of 50 μmol/L may exert the best effect on inhibition of osteoclasts.
7.An applied research on precise sustentacular screw placement based on anatomical division of the anterior lateral wall of calcaneus and the sustentaculum tali
Bing WANG ; Aixiang ZHU ; Ce SHI ; Jianning SUN ; Fenglei QIAO ; Wei JIANG ; Wei LI ; Jingjing ZHOU ; Guangsheng TANG ; Deguang WANG
Chinese Journal of Orthopaedic Trauma 2022;24(10):848-855
Objective:To evaluate our novel path based on anatomical division of the anterior lateral wall of calcaneus and the sustentaculum tali for precise sustentacular screw placement in the surgical treatment of calcaneal fractures of Sanders types Ⅱ and Ⅲ.Methods:The anterior lateral wall of the calcaneus was divided into the anterior-superior zone S 1, the anterior-inferior zone S 2, the posterior-superior zone S 3 and the posterior-inferior zone S 4 for demarcation of the screw insertion points by our method of Four Zones, and into the front, middle and rear sections by our method of Three Sections for demarcation of the screw target points. The specimens were scanned by CT and modeled by Mimics. On the 3D virtual model of the calcaneus, one screw was placed from each zone of the anterior lateral wall of the calcaneus to the sustentaculum tali body. The screw placement target for S 1 and S 2 was the medial intersection point P 1 of the front and middle sections of the sustentaculum tali, and that for S 3 and S 4 was the medial intersection point P 2 of the middle and rear sections of the sustentaculum tali. It was observed whether the screws were placed in the bone channel. A total of 72 patients were included who had been admitted to Department of Orthopaedics, Suqian Hospital Affiliated to Xuzhou Medical University for calcaneal fractures of Sanders types Ⅱ and Ⅲ from January 2017 to January 2021. They were divided into an anatomical division group and a 3D printing group according to their screw placement method for the sustentaculum tali. In the anatomical division group of 32 patients subjected to screw placement based on our anatomical division, there were 25 males and 7 females, aged from 24 to 60 years; in the 3D printing group of 40 patients subjected to screw placement assisted by 3D printing, there were 31 males and 9 females, aged from 25 to 58 years. The disparities between the parameters of sustentacular screw placement and the actual values were compared in the anatomical division group, and the total number of screws, screws on average, distribution of screws, and accuracy of screw placement were compared between the 2 groups. Results:All the screws which were virtually placed in the specimens of the calcaneus from S 1 and S 2 to P 1 and from S 3 and S 4 to P 2 passed through the bony channel, with no perforation into the tarsal sinus. There was no significant difference in the general date between the anatomical division group and the 3D printing group, showing they were comparable ( P > 0.05). In the anatomical division group, a total of 52 screws were placed to the sustentaculum tali with an average of (1.63 ± 0.48) screws per patient, and 2 screws were placed in 20 patients, yielding an accuracy rate of screw placement of 92.3% (48/52). There were no statistically significant differences between the parameters and the actual values of screw placement in the anatomical division group ( P > 0.05). In the 3D printing group, a total of 63 screws were placed to the sustentaculum tali with an average of (1.58 ± 0.49) screws per patient, and 2 screws were placed in 23 patients, yielding an accuracy rate of screw placement of 93.7% (59/63). There were no significant differences in the above comparisons between the anatomical division group and the 3D printing group ( P > 0.05). Conclusion:In the surgical treatment of calcaneal fractures of Sanders types Ⅱ and Ⅲ, the sustentacular screw placement based on our anatomical division of the anterior lateral wall of the calcaneus and the sustentaculum tali can lead to similar clinical accuracy as 3D printing-assisted screw placement does.
8.Comparison of minimally invasive reduction through a bone tunnel combined with Jail screwing and posterolateral locking plating for simple posterolateral tibial plateau fractures
Xiangru KONG ; Yuzhou SHAN ; Chun YANG ; Jianning SUN ; Xu LIU ; Wei JIANG ; Yu QIAN ; Taiming YANG ; Yucheng ZHU
Chinese Journal of Orthopaedic Trauma 2022;24(11):935-942
Objective:To compare the clinical effects of minimally invasive reduction through a bone tunnel combined with Jail screwing and those of posterolateral locking plating in the treatment of simple posterolateral tibial plateau fractures.Methods:A retrospective analysis was conducted of the data of 48 patients who had been operatively treated and completely followed up at Department of Orthopedics, Suqian Hospital of Nanjing Drum Tower Hospital Group for simple posterolateral tibial plateau fractures from October 2016 to October 2020. There were 26 males and 22 females, aged from 35 to 68 years. They were divided into a minimally invasive group (25 cases subjected to minimally invasive reduction through a bone tunnel combined with Jail screwing) and an incision group (23 cases subjected to posterolateral locking plating) according to their surgical methods. The operation time, incision length, intraoperative blood loss, fracture healing time, cumulative fluoroscopy time, hospital stay and posterior inclination angles of the tibial plateau and Hospital for Special Surgery (HSS) knee function scores at 1, 3, 6, 9, and 12 months after operation were compared between the 2 groups. Complications in the 2 groups of patients were recorded.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The 48 patients were followed up for 12 to 36 months (average 16.5 months). The minimally invasive group was significantly better than the incision group in operation time [(42.6±9.1) min versus (65.7±11.5) min], incision length [(4.0±0.4) cm versus (15.0±1.5) cm], intraoperative blood loss[(22.6±5.8) mL versus (31.5±8.8) mL], hospital stay [(7.6±1.4) d versus (11.1±2.4) d], and HSS score one month after operation [(84.8±1.9) points versus (72.9±4.1) points], but the cumulative fluoroscopy time in the incision group [(4.1±1.4) s]was significantly less than that in the minimally invasive group [(22.3±4.2) s] ( P<0.05). There were no significant differences in fracture healing time, HSS scores at 3, 6, 9, or 12 months after operation, or posterior inclination angle of the tibial plateau between the 2 groups ( P>0.05). There were no such complications as wound infection, vascular injury, internal fixation failure, nonunion or malunion of fractures in either of the 2 groups. Two cases in the incision group presented with symptoms of common peroneal nerve injury but recovered 3 months after operation. Conclusions:Although both minimally invasive reduction through a bone tunnel combined with Jail screwing and posterolateral locking plating can achieve satisfactory outcomes in the treatment of simple posterolateral tibial plateau fractures, the minimally invasive technique is preferable because it shows the advantages of a smaller incision, less bleeding, shorter operation time, a lower operation risk, quicker postoperative recovery and shorter hospital stay.
9.Advances in Treatment of Brain Metastasis from Lung Cancer
Junzhao SUN ; Gang CHENG ; Jianning ZHANG
Cancer Research on Prevention and Treatment 2022;49(6):522-527
Lung cancer is the malignant tumor with the highest incidence and mortality in China, and is prone to brain metastasis in the process of disease development, which seriously affects the quality of life and survival of patients. The treatment methods for brain metastasis of lung cancer include surgery, chemotherapy, whole brain radiotherapy, stereotactic radiosurgery, molecular targeted therapy, immunotherapy, anti-angiogenesis therapy, etc. It's one of the research hotspots to choose reasonable and effective treatment schemes for different patients. This paper reviews the research progress in the treatment of brain metastasis from lung cancer, to provide reference for selecting more reasonable clinical treatment for the patients.
10.Effect of Maiqi-Jiangtang pill on the glycolipid level in type 2 diabetic ob/ob mice
Fang FANG ; Xiaoye TIAN ; Na?Wuken SHA ; Xiaoli TANG ; Jinying WU ; Zhiwen QIAO ; Xiaoxue CHEN ; Xiaohong CHEN ; Jianning SUN
International Journal of Traditional Chinese Medicine 2019;41(1):39-43
Objective To investigate the effects of Maiqi-Jiangtang pill on the glycolipid level in type 2 diabetic ob/ob mice.Methods The 8-week old male ob/ob mice were randomly divided into Maiqi-Jiangtang pill high- (8 g/kg), medium- (4 g/kg), low- (2 g/kg) dose groups. All the mice orally adiministered with the drugs once a day for 10 weeks. The same week age normal C57BL/6J control mice and ob/ob model group mice were orally administered with the equal volume solvent. The body weight per week were recorded. The fasting blood-glucose (FBG) was measured by glycemic instrument. The content of TG, TC, HDL-C, LDL-C in serum, and TG and TC content in liver were determined by biochemical method. The liver index was calculated.Results Compared with ob/ob model group, there was no significant change in body weight of mice administered with Maiqi-Jiangtang pill for 10 weeks. Compared with the model group, the low-, medium- dose Maiqi-Jiangtang pill could significantly decrease the FBG (7.43 ± 1.71 mmol/L,7.84 ± 1.09 mmol/L vs.8.95 ± 0.96mmol/L), the high- dose Maiqi-Jiangtang pill could significantly reduce the TG (0.93 ± 0.16 mmol/L vs.1.18 ± 0.26 mmol/L) and LDL-C (2.10 ± 0.51 mmol/L vs.2.56 ± 0.44 mmol/L) content in serum of ob/ob mice (P<0.05), increase the HDL-C/LDL-C ratio (2.40 ± 0.39vs.1.96 ± 0.24) in serum (P<0.01), decrease the liver weight (3.52 ± 0.26 gvs. 3.98 ± 0.35 g) and the liver index (0.063 ± 0.004vs. 0.071 ± 0.006) (P<0.05). Compared with the model group, the low dose Maiqi-Jiangtang pill could also significantly decrease the TG level (0.63 ± 0.25 mmol/gvs. 1.05 ± 0.67 mmol/g) in liver and significantly increase the HDL-C/LDL-C ratio (2.30 ± 0.44vs. 1.96 ± 0.24) in serum (P<0.05).Conclusions The Maiqi-Jiangtang pill can reduce lipid in serum and liver of ob/ob mice while it can decrease the blood glucose, which need to further study its mechanism.

Result Analysis
Print
Save
E-mail