1.Comparision of aripiprazole and risperidone in improving psychiatric symptoms among chronic schizophrenia patients
Jianfeng WANG ; Bangwen LIU ; Yanyan ZHANG ; Yanping XUE ; Liang GUO ; Yanhai WU
Sichuan Mental Health 2025;38(2):108-114
BackgroundAtypical antipsychotics have been widely used in patients with chronic schizophrenia, and aripiprazole and risperidone are the most commonly used drugs. The mechanism of action of the two is different, while previous studies have provided insufficient credible evidence from multiple perspectives to support the comparative efficacy of the two drugs in improving symptoms in patients with chronic schizophrenia. ObjectiveTo compare the efficacy of aripiprazole and risperidone on the improvement of symptoms, prepulse inhibition (PPI), cognitive functioning and neurotrophic factors in patients with chronic schizophrenia, so as to provide effective treatment regimens for these patients. MethodsA total of 86 patients with chronic schizophrenia attending the psychiatry department of the Third People's Hospital of Fuyang from March 2021 to March 2023 and fulfilling the diagnostic criteria of International Classification of Diseases, tenth edition (ICD-10) were enrolled and grouped using random number table method, each with 43 cases. Aripiprazole group was given oral aripiprazole once daily at an initial dose of 5 mg for one week and then gradually increased to a maximum dose of 25 mg. Risperidone group received oral risperidone twice daily at an initial dose of 0.5 mg for one week and then gradually increased to a maximum dose of 3 mg. Treatment in both groups lasted 3 months. Before treatment and 3 months after treatment, Patients were required to complete Positive and Negative Symptom Scale (PANSS), detection of both strong and weak PPIs in a startle modification passive attention paradigm, Wisconsin Card Sorting Test (WCST) and the measurement of neurotrophic factors at baseline and after treatment. The adverse reactions were recorded. Analysis of covariance was used to test the difference between the PANSS score, PPI, WCST and neurotrophic factor levels of the groups, with the pretest used as the covariate. Results3 months after treatment, no statistical difference was found in the scores of PANSS general psychopathology subscale, positive symptom subscale, negative symptom subscale and total score between two groups after treatment (F=0.621, 0.815, 0.743, 0.752, P>0.05). There were no statistically significant differences between the two groups in PPI inhibition rate, single intense stimulus amplitude, single intense stimulus latency, prepulse inhibition amplitude, or prepulse inhibition latency (F=0.174, 0.001, 0.183, 0.171, 0.001, P>0.05). There was no statistically significant difference in the total number of WCST tests between two groups (F=0.512, P>0.05), whereas aripiprazole group reported significantly larger total numbers of categories completed and correct responses as well as smaller total numbers of random errors and perseverative errors compared to risperidone group (F=3.737, 4.621, 4.892, 5.130, P<0.05). A significant increase in brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) along with a reduction in glial fibrillary acidic protein (GFAP) were documented in risperidone group when compared to risperidone group (F=4.414, 3.781, 6.319, P<0.05). No significant difference was demonstrated in the incidence of adverse reactions between the two groups (χ2=0.261, P>0.05). ConclusionAripiprazole may be more beneficial than risperidone in improving cognitive functioning and neurotrophic factor levels in patients with chronic schizophrenia. [Funded by Scientific Research Project of Fuyang Municipal Health Commission in 2021 (number, FY2021-147)]
2.Sampling inspection results of disinfection products in Shaanxi Province in 2020 - 2023
Yongbing CHENG ; Baobao CHEN ; Xiaoling ZHANG ; Jianfeng XUE ; Xiaofeng DONG ; Zhaowei MENG
Journal of Public Health and Preventive Medicine 2024;35(6):93-96
Objectives To understand the quality status of disinfection products in the market in Shaanxi Province, and to provide a basis for taking targeted management measures. Methods From 2020 to 2023, in accordance with the national disinfection product management regulations and standards, the physicochemical and microbial tests of disinfection products in Shaanxi Province were carried out through supervised sampling, and the test results were analyzed according to the active ingredients, illegal addition, stability, and bactericidal or bacteriostatic performance. Results The overall qualification rate of the active ingredient content of disinfectants sampled in Shaanxi Province was 90.48%, with the lowest qualification rate in 2023 (84.38%). The overall qualification rate of quantitative sterilization test of disinfectants was 90.12%, showing a decreasing trend year by year (P=0.272). The overall qualification rate of anti-bacterial products was 88.59%, and the bactericidal test results of 20 antibacterial products were all qualified. The overall qualification rate of bacteriostatic performance testing for bacteriostatic products was 86.17%, with the pass rate of bacteriostatic product germicidal efficacy testing of different components in descending order being quaternary ammonium salt/silver ion > guanidine > others > lysozyme, and there was statistically significant difference (P=0.004). The detection rate of illegal additives in antimicrobial products was 7.07%, with the main detection indicators being miconazole nitrate, clobetasol propionate, and dexamethasone acetate. Conclusion The qualified rate of disinfection products in Shaanxi Province is relatively high, but there is a downward trend. It is necessary to continue to strengthen the daily supervision and product testing of disinfection product manufacturers, and promote the continuous improvement of disinfection product quality.
3.Application of three dimensional printed personalized guide plate assisted arthroscopic ankle arthrodesis in the treatment of ankle arthritis
Guangyi LI ; Cheng WANG ; Jiazheng WANG ; Chenglin WU ; Jieyuan ZHANG ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Zhongmin SHI ; Xin MA
Chinese Journal of Surgery 2024;62(6):572-580
Objective:To compare the efficacy of conventional open ankle fusion and three dimensional(3D) printed guide plate assisted arthroscopic ankle fusion.Methods:A retrospective cohort study was performed on 256 patients with advanced traumatic ankle arthritis, who were admitted to the Department of Orthopaedics, Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from May 2018 to February 2023 and underwent ankle fusion procedures. The study cohort comprised 119 males and 137 females, with an age of (59.6±9.5) years (range: 37 to 83 years). Among them, 175 cases underwent internal fixation with plates and screws (58 cases through the combined medial and lateral approach, and 117 cases through the simple lateral approach), 48 cases underwent internal fixation with screws through the anterior approach (conventional open group), and 33 cases underwent minimally invasive arthroscopic ankle fusion assisted by 3D printed guide plate (3D printed guide plate arthroscopy group). Propensity score matching was employed to achieve a 1∶1 match(caliper value=0.02) between the baseline characteristics of patients in the 3D printed guide plate arthroscopy group and the conventional open group. Perioperative and follow-up data between the two groups were compared using the t-test, Mann-Whitney U test, Wilcoxon signed rank test, χ2 test or corrected χ2 test as appropriate. Results:Matching was successfully achieved with 20 cases in both the 3D printed guide plate arthroscopy group and the conventional open group, and there were no statistically significant differences in baseline characteristics between the two groups (all P>0.05). The operation time in the 3D printed guide plate arthroscopy group was significantly longer than that in the conventional open group ((88.9±5.6) minutes vs. (77.9±11.7) minutes; t=-2.392, P=0.022), while the frequency of intraoperative fluoroscopies ((1.7±0.8) times vs. (5.2±1.2) times; t=10.604, P<0.01) and length of hospitalization ((5.5±0.9) days vs. (6.4±1.5) days; t=2.480, P=0.018) were significantly lower in the 3D printed guide plate arthroscopy group compared to the conventional open group. The fusion rate was 95.0% (19/20) in the 3D printed guide plate arthroscopy group and 85.0% (17/20) in the conventional open group, with no statistically significant difference between the two groups ( χ2=0.278, P=0.598). The fusion time was (12.1±2.0) weeks in the conventional open group and (11.1±1.7) weeks in the 3D printed guide plate arthroscopy group, with no statistically significant difference between the two groups ( t=1.607, P=0.116). At the final follow-up, the American Orthopedic Foot and Ankle Society ankle hindfoot scale was (72.6±5.5)points in the 3D printed guide plate arthroscopy group and (70.5±5.8)points in the conventional open group, with no statistically significant difference between the two groups ( t=-1.003, P=0.322). The pain visual analogue score of the 3D printed guide plate arthroscopy group was ( M(IQR)) 1.50 (1.00) points, lower than that of the conventional open group by 3.00 (1.00) points, with statistically significant differences ( Z=-3.937, P<0.01). There was no significant difference in complication rate between the conventional open group and the 3D printed guide plate arthroscopy group (25.0%(5/20) vs. 5.0%(1/20), χ2=1.765, P=0.184). Conclusion:3D printed guide plate assisted arthroscopic ankle fusion exhibited several advantages, including reduced frequency of fluoroscopies, alleviation of postoperative pain, and decreased complications and length of hospitalization.
4.Application of three dimensional printed personalized guide plate assisted arthroscopic ankle arthrodesis in the treatment of ankle arthritis
Guangyi LI ; Cheng WANG ; Jiazheng WANG ; Chenglin WU ; Jieyuan ZHANG ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Zhongmin SHI ; Xin MA
Chinese Journal of Surgery 2024;62(6):572-580
Objective:To compare the efficacy of conventional open ankle fusion and three dimensional(3D) printed guide plate assisted arthroscopic ankle fusion.Methods:A retrospective cohort study was performed on 256 patients with advanced traumatic ankle arthritis, who were admitted to the Department of Orthopaedics, Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from May 2018 to February 2023 and underwent ankle fusion procedures. The study cohort comprised 119 males and 137 females, with an age of (59.6±9.5) years (range: 37 to 83 years). Among them, 175 cases underwent internal fixation with plates and screws (58 cases through the combined medial and lateral approach, and 117 cases through the simple lateral approach), 48 cases underwent internal fixation with screws through the anterior approach (conventional open group), and 33 cases underwent minimally invasive arthroscopic ankle fusion assisted by 3D printed guide plate (3D printed guide plate arthroscopy group). Propensity score matching was employed to achieve a 1∶1 match(caliper value=0.02) between the baseline characteristics of patients in the 3D printed guide plate arthroscopy group and the conventional open group. Perioperative and follow-up data between the two groups were compared using the t-test, Mann-Whitney U test, Wilcoxon signed rank test, χ2 test or corrected χ2 test as appropriate. Results:Matching was successfully achieved with 20 cases in both the 3D printed guide plate arthroscopy group and the conventional open group, and there were no statistically significant differences in baseline characteristics between the two groups (all P>0.05). The operation time in the 3D printed guide plate arthroscopy group was significantly longer than that in the conventional open group ((88.9±5.6) minutes vs. (77.9±11.7) minutes; t=-2.392, P=0.022), while the frequency of intraoperative fluoroscopies ((1.7±0.8) times vs. (5.2±1.2) times; t=10.604, P<0.01) and length of hospitalization ((5.5±0.9) days vs. (6.4±1.5) days; t=2.480, P=0.018) were significantly lower in the 3D printed guide plate arthroscopy group compared to the conventional open group. The fusion rate was 95.0% (19/20) in the 3D printed guide plate arthroscopy group and 85.0% (17/20) in the conventional open group, with no statistically significant difference between the two groups ( χ2=0.278, P=0.598). The fusion time was (12.1±2.0) weeks in the conventional open group and (11.1±1.7) weeks in the 3D printed guide plate arthroscopy group, with no statistically significant difference between the two groups ( t=1.607, P=0.116). At the final follow-up, the American Orthopedic Foot and Ankle Society ankle hindfoot scale was (72.6±5.5)points in the 3D printed guide plate arthroscopy group and (70.5±5.8)points in the conventional open group, with no statistically significant difference between the two groups ( t=-1.003, P=0.322). The pain visual analogue score of the 3D printed guide plate arthroscopy group was ( M(IQR)) 1.50 (1.00) points, lower than that of the conventional open group by 3.00 (1.00) points, with statistically significant differences ( Z=-3.937, P<0.01). There was no significant difference in complication rate between the conventional open group and the 3D printed guide plate arthroscopy group (25.0%(5/20) vs. 5.0%(1/20), χ2=1.765, P=0.184). Conclusion:3D printed guide plate assisted arthroscopic ankle fusion exhibited several advantages, including reduced frequency of fluoroscopies, alleviation of postoperative pain, and decreased complications and length of hospitalization.
5.Laparoscopic surgery contributes to a decrease in short-term complications in surgical ulcerative colitis patients during 2008–2017: a multicenter retrospective study in China
Zerong CAI ; Xiaosheng HE ; Jianfeng GONG ; Peng DU ; Wenjian MENG ; Wei ZHOU ; Jinbo JIANG ; Bin WU ; Weitang YUAN ; Qi XUE ; Lianwen YUAN ; Jinhai WANG ; Jiandong TAI ; Jie LIANG ; Weiming ZHU ; Ping LAN ; Xiaojian WU
Intestinal Research 2023;21(2):235-243
Background/Aims:
The aim of this study was to analyze the chronological changes in postoperative complications in surgical ulcerative colitis patients over the past decade in China and to investigate the potential parameters that contributed to the changes.
Methods:
Ulcerative colitis patients who underwent surgery during 2008–2017 were retrospectively enrolled from 13 hospitals in China. Postoperative complications were compared among different operation years. Risk factors for complications were identified by logistic regression analysis.
Results:
A total of 446 surgical ulcerative colitis patients were analyzed. Fewer short-term complications (24.8% vs. 41.0%, P=0.001) and more laparoscopic surgeries (66.4% vs. 25.0%, P<0.001) were found among patients who received surgery during 2014–2017 than 2008–2013. Logistic regression suggested that independent protective factors against short-term complications were a higher preoperative body mass index (odds ratio [OR], 0.870; 95% confidence interval [CI], 0.785–0.964; P=0.008), laparoscopic surgery (OR, 0.391; 95% CI, 0.217–0.705; P=0.002) and elective surgery (OR, 0.213; 95% CI, 0.067–0.675; P=0.009). The chronological decrease in short-term complications was associated with an increase in laparoscopic surgery.
Conclusions
Our data revealed a downward trend of short-term postoperative complications among surgical ulcerative colitis patients in China during the past decade, which may be due to the promotion of minimally invasive techniques among Chinese surgeons.
6.Efficacy of osteochondral fragment fixation using bioabsorbable pins for Hepple Ⅱ osteochondral lesions of the talus in adolescents
Cheng WANG ; Xueqian LI ; Shaoling FU ; Chenglin WU ; Jiazheng WANG ; Jieyuan ZHANG ; Guangyi LI ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Guoxun SONG ; Wenqi GU ; Zhongmin SHI
International Journal of Surgery 2023;50(7):473-480,C2-C3
Objective:To investigate the efficacy of osteochondral fragment fixation using bioabsorbable pins for Hepple Ⅱ osteochondral lesions of the talus (OLT) in adolescents.Methods:Retrospective case analysis was used. The clinical data and follow-up results of 13 adolescent patients (13 feet) with Hepple Ⅱ OLT were all treated with osteochondral fragment fixation using bioabsorbable pins admitted to Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from January 2017 to December 2021 were retrospectively analyzed. There were 7 males and 6 females, with 13 right feet. The age was (14.85±2.23) years old, ranged from 12 to 18 years old. According to the American orthopedic foot and ankle society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) and SF-36 score before operation and at the last follow-up were used to evaluate the efficacy and function of the patients. Measurement data with normal distribution were represented as mean ± standard deviation( ± s), and the comparison between groups was conducted using the t-test; The mearsurement data with skewness distribution were expressed by M( Q1, Q3), and rank-sum test was used for inter-group comparison. Results:Thirteen adolescent patients (13 feet) with Hepple Ⅱ OLT underwent surgery successfully and were followed up for (25.54±9.95) months. All wounds healed by first intention, and no complications such as wound infection and delayed healing occurred. Preoperative AOFAS ankle-posterior foot score, VAS and SF-36 score were 58.62±3.55, 7.00 (6.50, 8.00) and 68.38±4.81, respectively. At the last follow-up, the scores were 97.38±2.73, 1.00 (0.00, 1.00), 91.15±4.28, respectively, and the results were significantly improved at the last follow-up, with the difference between the two groups statistically significant( P<0.05). Conclusion:Osteochondral fragment fixation using bioabsorbable pins which can promote cartilage repair, significantly improve symptoms, and achieve better clinical satisfaction with fewer complications, is a safe and effective surgical treatment option for Hepple Ⅱ OLT in adolescents with satisfactory short-term clinical outcomes.
7.Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment
Yong ZHOU ; Zeying JIANG ; Baofeng SU ; Jianfeng ZHOU ; Qian WANG ; Anting WANG ; Jingxian LIU ; Yan XUE ; Huiyi FENG ; Xiaoliang WU ; Mingxing XIAO ; Wenyong TAN
Cancer Research on Prevention and Treatment 2023;50(11):1097-1102
Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT. Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement. Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (
8.The full process operating procedure for the using of multi -center retrospective electronic medical record data
Xue ZHONG ; Dongfang QIAN ; Zixuan ZHANG ; Siyuan TAN ; Jianfeng LIU ; Xueyan CUI ; Ruifang NIE ; Ting LI ; Qian WANG ; Qi GUO ; Qiushuang LIU ; Yan LIANG ; Lin HUANG ; Lizong LI ; Yufei FENG
China Pharmacy 2022;33(19):2314-2320
With the gradual improvement of medical informatization and the vigorous development of medical and health big data,the exploration and practice of real -world research are becoming more and more mature ,and real -world data have become an important source of evidence for post marketing re -evaluation of drugs . As an important high -quality real -world medical data , electronic medical record data is an indispensable data source for post marketing re -evaluation of drugs . Most of the existing guidelines and norms of real -world research are designed from the perspective of prospective research ,and do not propose specific measures and methods in the implementation of retrospective research ,especially for the operation suggestions on the technical level of using conventionally collected electronic medical record data . In combination with the operational process framework formulated by the existing guidelines and norms ,this paper creatively adds the operating procedures for dataE- validation,data integration ,data verification ,and throughout quality control ,data management and storage of retrospectiveelectronic medical record data ,and describes the data analysis methods and key points involved in carrying out multi -center retrospective real -world research using electronic medical record data ,taking the post marketing safety research of drugs as an example. Finally,the full process operation procedure applicable to the use of multi -center retrospective electronic medical record data is established .
9.Mid-term effects of surgery for sub-acute injury to distal tibiofibular syndesmosis associated with ankle fracture
Cheng CHEN ; Xueqian LI ; Shaoling FU ; Cheng WANG ; Guohua MEI ; Yan SU ; Jianfeng XUE ; Jian ZOU ; Wenqi GU ; Guoxun SONG ; Zhongmin SHI
Chinese Journal of Orthopaedic Trauma 2022;24(1):10-18
Objective:To evaluate the mid-term efficacy of surgery for sub-acute injury to distal tibiofibular syndesmosis associated with ankle fracture.Methods:From July 2014 to October 2019, 14 patients were treated at Foot & Ankle Section, Department of Orthopaedics, Shanghai Sixth People’s Hospital for sub-acute injury to distal tibiofibular syndesmosis associated with ankle fracture.There were 11 males and 3 females, aged from 17 to 61 years (mean, 35.9 years).According to Danis-Weber classification, 6 cases were type B and 8 type C; according to Lauge-Hansen classification, 7 cases belonged to supination-external rotation, one to pronation-abduction, and 6 to pronation-external rotation (Maisonneuve fracture in 4).The syndesmosis injury was treated by fixation with distal tibiofibular screws in 11 cases, by Tightrope elastic fixation in one, by hybrid fixation with distal tibiofibular screws and Tightrope in one, and by distal tibiofibular fusion in one.Postoperative complications were recorded.Their visual analogue scale (VAS) and American Orthopaedic Foot and Ankle Society ankle-hindfoot scores (AOFAS-AH) were compared between preoperation and the last follow-up.Results:The 14 patients were followed up for 24 to 85 months (mean, 46.8 months). Of the 9 patients whose distal tibiofibular screws had been removed (including one with hybrid fixation), wound infection occurred in one after removal of all the internal fixation, distal tibiofibular widening in 2, ankle degeneration in 5 and fibular nonunion in one. Of the other 3 patients whose distal tibiofibular screws had not been removed, screw breakage happened in 2, screw loosening in one and distal tibiofibular widening in one. The VAS scores were significantly improved from preoperative 6.8±0.9 to 1.4±1.3 at the last follow-up; the AOFAS-AH scores were increased significantly from preoperative 35.3±6.3 to 86.8±11.7 at the last follow-up (both P<0.001). According to AOFAS-AH scores, 8 cases were excellent, 4 good and 2 moderate. Conclusion:Surgery for sub-acute injury to distal tibiofibular syndesmosis associated with ankle fracture can restabilize the distal tibiofibular syndesmosis and ankle joint, reduce pain and improve ankle function, leading to fine mid-term efficacy.
10.Morphology of dorsal medial talar neck osteophyte and its clinical significance: based on three-dimensional computed tomography
Cheng CHEN ; Shaoling FU ; Xueqian LI ; Cheng WANG ; Lin YANG ; Guohua MEI ; Yan SU ; Jianfeng XUE ; Jian ZOU ; Wenqi GU ; Guoxun SONG ; Zhongmin SHI
Chinese Journal of Orthopaedic Trauma 2022;24(4):299-304
Objective:To study the morphology of dorsal medial talar neck osteophyte (DMTNO) and its association with anteromedial ankle impingement syndrome (AAIS) using CT 3D reconstruction images.Methods:The present retrospective study included 23 patients with AAIS due to DMTNO (case group) and 23 patients with DMTNO but without AAIS (control group) who had been admitted from February 2019 to June 2021. Multi-slice CT data (DICOM) of DMTNO in both groups were collected and imported into Arigin 3D Pro 3D reconstruction software to reconstruct and observe the 3D morphology of DMTNO. The dorsal convex distance, medial convex distance and anterior convex distance of DMTNO were measured to find their association with AAIS.Results:In the case group, DMTNO clearly showed a flat polyhedral shape with a large base and a small top; in the control group, DMTNO showed various shapes that were different mainly in an irregular top but similar in a large, long and narrow base. The dorsal convex distance [(8.07±2.30) mm] and medial convex distance [(6.70±2.62) mm] in the case group were significantly larger than those in the control group [(3.59±1.10) mm and (1.98±0.93) mm] ( P<0.05), but there was no significant difference between the 2 groups in the anterior convex distance ( P>0.05). Conclusions:The DMTNO leading to AAIS shows a flat polyhedral shape with a large base and a small top. No correlation is found between the anterior convex and AAIS whereas the dorsal convex and medial convex of DMTNO may be closely associated with AAIS.


Result Analysis
Print
Save
E-mail