1.The correlation between the degree of devascularization of peripheral arteriovenous malformations and clinical outcomes after interventional embolization and sclerotherapy
Xueqiang FAN ; Bo MA ; Qiangqiang NIE ; Yisen DENG ; Xixi GUO ; Yuguang YANG ; Jianbin ZHANG ; Xia ZHENG ; Peng LIU ; Zhidong YE
Chinese Journal of General Surgery 2024;39(11):861-864
Objective:To explore the relationship between the degree of devascularization and clinical outcomes after interventional embolization and sclerotherapy for peripheral arteriovenous malformations.Method:A retrospective analysis was conducted on the data of 37 patients with peripheral arteriovenous malformations admitted at Department of Cardiovascular Surgery, China-Japan Friendship Hospital from July 2021 to June 2023. All patients received the treatment of "nidus" and/or outflow veins embolization combined with sclerotherapy injection. Two experienced physicians evaluated the degree of devascularization before and after treatment, and conducted a correlation study with clinical outcomes after follow-up.Result:All 37 patients were symptomatic. Swelling and pain accounted for 75.7% of all the cases. Twenty-six patients received only one procedure, 3 patients received re-interventional treatments. The average follow-up time was(13.3±5.0)months. Clinical symptoms were completely relieved in 14 patients, and partial relief in 22 patients. The overall effective rate was 97%. There were 6 patients with degree of de vascularization<50% during procedure, 16 patients with degree of 50%-75%, and 5 patients with degree of 75%-90%, 10 cases with degree over 90%. Patients with devascularization degrees less than 60% can not achieve clinical symptom relief.Conclusions:There is a positive correlation between the degree of devascularization and clinical outcomes in the interventional embolization and sclerotherapy of peripheral arteriovenous malformations, and 60% of the degree of devascularization can serve as the "threshold" for effectiveness of treatment.
2.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
3.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
4.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Paclitaxel drug-coated balloons combined with bare metal stents vs. bare metal stents for the treatment of superficial femoral atherosclerosis obliterans
Qijian ZHAO ; Jianbin ZHANG ; Hao ZHAO ; Bin HE ; Xuming WANG ; Bo MA ; Jie CHEN ; Chong CHEN ; Zhidong YE
Chinese Journal of General Surgery 2023;38(7):500-505
Objective:To compare the efficacy and safety of drug-coated balloons (DCB) combined with bare metal stents (BMS) and BMS only for superficial femoral atherosclerosis obliterans.Methods:The clinical and follow-up data of 80 patients (82 limbs) who received combined treatment or BMS implantation at Cardiovascular Surgery Department of China Japan Friendship Hospital from Jan 2017 to Aug 2022 were retrospectively analyzed.Results:43 patients (43 limbs) were included in combined treatment group. 37 patients (39 limbs) were in BMS only. The average lesion length of combined group was longer than BMS group (19.54±7.04 cm vs. 16.25±6.43 cm, P=0.031). The primary patency rate of combined group at 36 months was not statistically different with BMS only group (56.9% vs. 38.5%, P=0.171). The subgroup analysis of superficial femoral artery TASC C/D (Trans-Atlantic Inter-Society Consensus) and CTO (chronic total occlusion) lesions indicated that efficacy of the combined group was superior to BMS only group. The patency rates of the combined group compared with the BMS group at 36 months were 57.6% vs. 23.8%, P=0.046, 60.2% vs. 31.4%, P=0.028, respectively. There was no significant difference in the FCD-TLR (free from clinical driven target lesion revascularization) between the two groups at 36 months (72.6% vs. 66.5%, P=0.706). There was no significant difference in major adverse events between the two groups ( P>0.05). Conclusion:Paclitaxel drug-coated balloon combined with bare metal stent is a safe and effective treatment for superficial femoral atherosclerosis obliterans, which is superior to bare metal stent, especially in TASC C/D and chronic total occlusive lesions.
8.Prediction of 1p/19q codeletion status in diffuse lower-grade glioma using multimodal MRI radiomics.
Mingjun LU ; Yaoming QU ; Andong MA ; Jianbin ZHU ; Xue ZOU ; Gengyun LIN ; Yuxin LI ; Xinzi LIU ; Zhibo WEN
Journal of Southern Medical University 2023;43(6):1023-1028
OBJECTIVE:
To develop a noninvasive method for prediction of 1p/19q codeletion in diffuse lower-grade glioma (DLGG) based on multimodal magnetic resonance imaging (MRI) radiomics.
METHODS:
We collected MRI data from 104 patients with pathologically confirmed DLGG between October, 2015 and September, 2022. A total of 535 radiomics features were extracted from T2WI, T1WI, FLAIR, CE-T1WI and DWI, including 70 morphological features, 90 first order features, and 375 texture features. We constructed logistic regression (LR), logistic regression least absolute shrinkage and selection operator (LRlasso), support vector machine (SVM) and Linear Discriminant Analysis (LDA) radiomics models and compared their predictive performance after 10-fold cross validation. The MRI images were reviewed by two radiologists independently for predicting the 1p/19q status. Receiver operating characteristic curves were used to evaluate classification performance of the radiomics models and the radiologists.
RESULTS:
The 4 radiomics models (LR, LRlasso, SVM and LDA) achieved similar area under the curve (AUC) in the validation dataset (0.833, 0.819, 0.824 and 0.819, respectively; P>0.1), and their predictive performance was all superior to that of resident physicians of radiology (AUC=0.645, P=0.011, 0.022, 0.016, 0.030, respectively) and similar to that of attending physicians of radiology (AUC=0.838, P>0.05).
CONCLUSION
Multiparametric MRI radiomics models show good performance for noninvasive prediction of 1p/19q codeletion status in patients with in diffuse lower-grade glioma.
Humans
;
Magnetic Resonance Imaging
;
Chromosome Aberrations
;
Area Under Curve
;
Glioma/genetics*
;
ROC Curve
9.Progress on application of artificial intelligence technology in orthodontic diagnosis and treatment
MA Jianbin ; XUE Chaoran ; BAI Ding
Journal of Prevention and Treatment for Stomatological Diseases 2022;30(4):278-282
In recent years, artificial intelligence technology has developed rapidly and has been gradually applied to the fields of clinical image data processing, auxiliary diagnosis and prognosis evaluation. Research has shown that it can simplify doctors’ clinical tasks, quickly provide analysis and processing results, and has high accuracy. In terms of orthodontic diagnosis and treatment, artificial intelligence can assist in the rapid fixation of two-dimensional and three-dimensional cephalometric measurements. In addition, it is also widely used in the efficient processing and analysis of three-dimensional dental molds data, and shows considerable advantages in determining deciding whether orthodontic treatment needs tooth extraction, thus assisting in judging the stage of growth and development, orthodontic prognosis and aesthetic evaluation. Although the application of artificial intelligence technology is limited by the quantity and quality of training data, combining it with orthodontic clinical diagnosis and treatment can provide faster and more effective analysis and diagnosis and support more accurate diagnosis and treatment decisions. This paper reviews the current application of artificial intelligence technology in orthodontic diagnosis and treatment in the hope that orthodontists can rationally treat and use artificial intelligence technology in the clinic, and make artificial intelligence better serve orthodontic clinical diagnosis and treatment, so as to promote the further development of intelligent orthodontic diagnosis and treatment processes.
10.Effect of Notch on femoral periprosthetic fractures after primary total knee arthroplasty
Pengfei WEN ; Yakang WANG ; Binfei ZHANG ; Linjie HAO ; Jianbin GUO ; Jun WANG ; Tao MA ; Siqing QIN ; Ying YAO ; Yumin ZHANG
Chinese Journal of Orthopaedics 2022;42(3):141-148
Objective:To investigate the effect of Notch on periprosthetic fracture (PPF) of the femoral prosthesis after primary total knee arthroplasty.Methods:A total of 34 patients diagnosed with femoral PPF at Xi'an Honghui Hospital were retrospectively collected from January 2013 to December 2020. There were 4 males and 30 females with a mean age of 69.2±7.2 years (range, 55-84 years). A total of 102 patients without PPF were matched by gender and age as the control group in a ratio of 1∶3. There were 12 males and 90 females with a mean age of 69.2±7.2 years (range, 55-84 years). The main observation indexes included patients' general information and factors such as coronal alignment, prosthesis design and Notch conditions. Then, subgroup analysis was performed with the depth and Tayside classification of Notch to analyze their effects on PPF.Results:The PPF and control groups were comparable in terms of baseline information such as gender, age, body mass index (BMI), and surgical side. There was no significant difference between the two groups in coronal alignment (χ 2=1.019, P=0.601) and prosthesis design (χ 2=1.545, P=0.214). There was no statistical difference in Notch between the PPF and control groups (χ 2=3.548, P=0.060). The mean length of Notch in the PPF group was 4.5±2.7 mm, compared with 4.9±2.8 mm in the control group, with no significant difference between the two groups ( t=0.732, P=0.465). Further subgroup analysis using a Notch depth of 3 mm as a cut-off and Tayside classification revealed a statistical difference between the two groups (χ 2=11.262, P=0.004; χ 2=14.601, P=0.003). Compared with patients without Notch, the risk of PPF was higher when the depth of Notch exceeded 3 mm, with an odds ratio ( OR) of 4.88 (95% CI: 1.76, 13.51). The incidence of PPF was higher when Notch depth reached Tayside grade 3 or 4. Compared with patients without Notch, the risk of PPF would be 6.99-fold (95% CI: 1.85, 26.32) higher when Notch depth reached grade 3. In female patients, there was a significant difference in Notch status between the PPF and control groups (χ 2=3.956, P=0.047), with a higher risk of PPF in female patients with Notch, OR 2.33 (95% CI: 1.01, 5.43). In patients who underwent right-sided TKA, the risk of PPF was higher in patients with Notch compared to those without Notch (χ 2=5.502, P=0.019), with an OR of 3.58 (95% CI: 1.19, 10.75). Conclusion:The Notch has no significant effect on the femoral PPF after primary total knee arthroplasty. However, the risk of PPF will increase significantly when the Notch depth exceeds 3 mm or is above Tayside grade 3.


Result Analysis
Print
Save
E-mail