1.Principles, technical specifications, and clinical application of lung watershed topography map 2.0: A thoracic surgery expert consensus (2024 version)
Wenzhao ZHONG ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Wei JIANG ; Deping ZHAO ; Hecheng LI ; Xiaolong YAN ; Lijie TAN ; Junqiang FAN ; Guibin QIAO ; Qiang NIE ; Mingqiang KANG ; Weibing WU ; Hao ZHANG ; Zhigang LI ; Zihao CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):141-152
With the widespread adoption of low-dose CT screening and the extensive application of high-resolution CT, the detection rate of sub-centimeter lung nodules has significantly increased. How to scientifically manage these nodules while avoiding overtreatment and diagnostic delays has become an important clinical issue. Among them, lung nodules with a consolidation tumor ratio less than 0.25, dominated by ground-glass shadows, are particularly worthy of attention. The therapeutic challenge for this group is how to achieve precise and complete resection of nodules during surgery while maximizing the preservation of the patient's lung function. The "watershed topography map" is a new technology based on big data and artificial intelligence algorithms. This method uses Dicom data from conventional dose CT scans, combined with microscopic (22-24 levels) capillary network anatomical watershed features, to generate high-precision simulated natural segmentation planes of lung sub-segments through specific textures and forms. This technology forms fluorescent watershed boundaries on the lung surface, which highly fit the actual lung anatomical structure. By analyzing the adjacent relationship between the nodule and the watershed boundary, real-time, visually accurate positioning of the nodule can be achieved. This innovative technology provides a new solution for the intraoperative positioning and resection of lung nodules. This consensus was led by four major domestic societies, jointly with expert teams in related fields, oriented to clinical practical needs, referring to domestic and foreign guidelines and consensus, and finally formed after multiple rounds of consultation, discussion, and voting. The main content covers the theoretical basis of the "watershed topography map" technology, indications, operation procedures, surgical planning details, and postoperative evaluation standards, aiming to provide scientific guidance and exploration directions for clinical peers who are currently or plan to carry out lung nodule resection using the fluorescent microscope watershed analysis method.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Construction of Chinese Herbal Medicine Traceability System Based on Influencing Factors of Chinese Herbal Medicine Quality
Kunyang LAI ; Jiancai XIAO ; Binbin YAN ; Xiufu WAN ; Jian YANG ; Guangxing MENG ; Chuanzhi KANG ; Kai SUN ; Yan ZHANG ; Lanping GUO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):215-224
As a Chinese saying goes, "good Chinese medicinal material makes good medicine", the quality of Chinese herbal medicines is related to the development prospect of Chinese medicine industry in China. With the rapid development of new technologies such as traceability methods and monitoring instruments, it is imperative to integrate and innovate traditional Chinese herbal medicines with new-generation information technology in view of the quality problems existing in the current production and circulation of Chinese herbal medicines, and it is of great significance for the construction of traceability system to ensure the quality and safety of Chinese herbal medicines and to promote the industry of Chinese herbal medicines to move towards high-quality development. This paper reviews the development history of the traceability system of Chinese herbal medicines in China, takes the influencing factors of the quality of Chinese herbal medicines as the entry point, and proposes that the construction of the traceability system should satisfy the traceability requirements of the characteristics of Chinese herbal medicines and their traditional medication experience. By analyzing the influencing factors of the quality of Chinese herbal medicines, it is pointed out that focusing on the influencing factors to build a traceability system is of great significance for targeting the problematic links at a later stage and exploring the interrelationship between environmental factors and the quality of Chinese herbal medicines. Based on the previous explorations, the author summarizes the system framework, functional modules and practical applications of the traceability system of Chinese herbal medicines, and looks forward to the development of a traceability system with risk early warning function and expert decision-making function in its functional development. Finally, based on the factors affecting the quality of Chinese herbal medicines, the author puts forward several thoughts on construction of the traceability system, and makes an in-depth analysis and puts forward a solution for the current situation that a unified, standardized and universal traceability system has not yet been built, with a view to providing ideas and references for the construction of traceability system of Chinese herbal medicines.
8.Relationship between zinc finger protein A20, CTGF and FibroScan and fibrosis in chronic hepatitis B patients
Song ZHANG ; Zilong ZHAO ; Qian HU ; Jian LI ; Xiaojing WANG ; Huijie GENG ; Haiyan KANG ; Dianxing SUN ; Zhengrong GUO
Journal of Public Health and Preventive Medicine 2024;35(3):133-136
Objective Studies on the expression and location of zinc finger protein A20 (A20) and connective tissue growth factor (CTGF) in liver tissues of patients with chronic hepatitis B were conducted, and the relationship between them and liver fibrosis was determined by FibroScan. Methods Studies on A20 and CTGF in liver tissues of 160 patients with chronic hepatitis B were conducted in accordance with the stage of pathological fibrosis and inflammation of the liver, and quantitative immunohistochemistry test was conducted, and statistical analysis was conducted by FibroScan. Results The expressions of A20 and CTGF in liver tissues increased with the aggravation of liver pathological fibrosis and inflammation, and there were significant differences between each stage and the control group (P<0.05), and there were significant differences between adjacent groups (P<0.05). Studies have shown that FibroScan increases along with pathological fibrosis and inflammation in the liver. There are significant differences between the stage and the control group (P<0.05), and no significant differences between the adjacent groups (P>0.05). There was positive correlation between liver A20 and CTGF, r=0.796 (P<0.05). Conclusions In patients with chronic hepatitis B, A20, CTGF and FibroScan are positively correlated with the degree of liver fibrosis, and A20 and CTGF are also positively correlated with the degree of liver inflammation, which can be used as indicators to evaluate the degree of liver inflammation and fibrosis, and further guide the anti-inflammatory and anti-fibrosis treatment of patients.
9.The Genetic Polymorphism and Structural Analysis of 47 Microhaplotypes in a Jiangsu Changshu Chinese Han Population
Kun-Peng PAN ; Yao-Sen FENG ; Wen-Shuai YU ; Zong-Wei LIU ; Yi-Ren YAO ; Jie ZHAO ; Ke-Lai KANG ; Chi ZHANG ; Le WANG ; Jian WU
Progress in Biochemistry and Biophysics 2024;51(2):423-434
ObjectiveTo investigate the genetic polymorphism and structure of 47 autosomal microhaplotypes in the Han population in Changshu City, Jiangsu Province, and to evaluate the forensic efficiencies and forensic parameters. MethodsThe DNA library of unrelated individual samples was prepared according to MHSeqTyper47 kit manual and sequenced on the MiSeq FGx platform. Microhaplotype genotyping and sequencing depth statistics were processed using MHTyper. The genetic information of samples was then evaluated. The fixation index and genetic distance between the Jiangsu Changshu population and the reference populations in the 1000 Genomes Project phase 3 (1KG) were calculated, and forensic parameters were evaluated. ResultsThe fixation index and genetic distance between the Han population in Changshu, Jiangsu, and the CHB (Han Chinese in Beijing, China) reference population in 1KG were the lowest. The effective allele number (Ae) of each locus is also the closest between the two populations. The combined matching probability (CMP) of the Changshu Han population is close to the 5 populations of the East Asian reference super-population in 1KG, which is 1.25×10-36, and the combined probability of exclusion reached 0.999 999 999 964 1. ConclusionThis study reported the genetic polymorphism and allele frequency of 47 microhaplotypes in a Han population in Changshu City, Jiangsu Province. This information provides a data basis for 47 microhaplotypes in forensic applications. In addition, the polymorphism differences between the 1KG reference population and the Han population in Changshu, Jiangsu were compared, and the genetic structure of 47 microhaplotypes in the Han population in Changshu, Jiangsu was revealed. In general, the reference data of the East Asian super-population in 1KG is more in line with the genetic characteristics of Han population in Changshu, Jiangsu.
10.Analysis of the causes of revision total knee arthroplasty
Jian JIN ; Liyi ZHANG ; Wulin KANG ; Xuan GAO ; Jianhao LIN ; Zhichang LI
Chinese Journal of Orthopaedics 2024;44(4):217-225
Objective:To assess causes for revision total knee arthroplasty (TKA) in China using the data of revision TKA in the past 15 years in our single center andcompare the differences in survival time, operation time and blood loss among different revision reasons.Methods:Data of 337 patients (345 knees) with revision TKAs at our institution from January 2007 to December 2021 (15 years) were retrospectively analyzed. The included population consists of 57 males and 288 females. The causes for first revision TKA were identified and compared according to the time of revision surgery as early (up to 2 years) and late revision (more than 2 years). The reason for revision before 2012 and after 2012 was also compared. Furthermore, the differences of survival time, operation time and blood loss among different revision reasons were compared.Results:The most common reasons for revision of knee joints in 345 cases were periprosthetic infection (133 knees, 38.6%), followed by aseptic loosening (97 knees, 28.1%) and joint instability (35 knees, 10.1%). Early revisions were performed in 171 knees (49.6%), while late revisions were performed in 174 knees (50.4%). Periprosthetic infection (96 knees, 56.1%) and aseptic loosening (86 knees, 49.4%) were the most common reasons for early and late revisions, respectively. There were 59 revisions performed before 2012 and 286 revisions performed after 2012, with periprosthetic infection being the main reason for revision in both groups. The percentage of revisions due to infection decreased from 64.4% before 2012 to 33.2% after 2012, and this difference was statistically significant (χ 2=18.790, P<0.001). The proportion of revisions due to aseptic loosening was 15.3% before 2012, which was significantly lower than the proportion of 30.8% after 2012 (χ 2=5.083, P=0.024). The median survival time of the prostheses in the included patients was 30 months, with shorter survival time observed in patients with stiffness, patellar complications, and periprosthetic infection, and longer survival time observed in patients with polyethylene wear and aseptic loosening. There were significant differences in operation time and blood loss among different reasons for revision ( P<0.001). Conclusion:In our specialized arthroplasty center periprosthesis infection was the most common reason for revision. Periprosthesis infection and aseptic loosening needed to be considered for early or late-stage revision. With the development of technique of total knee arthroplasty, the proportion of periprosthesis infection is decreasing, while the incidence of aseptic loosening is increasing.


Result Analysis
Print
Save
E-mail