1.Application of strut-septum complex stent in nasal tip refinement of secondary unilateral cleft rhinoplasty
DONG Zhe ; LI Qiaoqiao ; YANG Jiegang ; FU Yuchuan ; LI Jian
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(7):563-572
		                        		
		                        			Objective:
		                        			To evaluate the clinical efficacy of costal cartilage septal-columellar composite grafts in refining nasal tip aesthetics for secondary unilateral cleft lip nasal deformities, and to provide a reference for clinical treatment.
		                        		
		                        			Methods:
		                        			This study has been approved by the institutional medical ethics committee and informed consent was obtained from the patients. A total of 31 patients underwent surgery with a costal cartilage strut-septum complex stent graft. The follow-up period was a minimum of 6 months. Anteroposterior, lateral, and supine photos of the patient were taken before and after the operation. The following measurements were obtained: nasal tip projection (NTP), nasofrontal angle (NFA), nasolabial angle (NLA), nasal tip alar angle (NAA), and nasal tip tangent angle (NTA). Nostril-related indices [nostril area (S), nostril height (h1), nostril width (w), and nasal sill height (h2)]) were measured before and after surgery, and cleft/non-cleft side ratios were calculated. Satisfaction with nasal tip aesthetics was investigated using the visual analogue scale (VAS). All measurements were made using preoperative photographs and the most recent follow-up photographs of the patients. Results The follow-up period ranged from 6 to 49 months, with an average of 28 months. All patients underwent healing
		                        		
		                        			Results:
		                        			The follow-up period ranged from 6 to 49 months, with an average of 28 months. All patients underwent healing by first intention. Compared with preoperative measurements, postoperative NTP (preoperative 0.48 vs. postoperative 0.55), NLA (preoperative 83.98° vs. postoperative 100.80°), and NAA (preoperative 160.30° vs. postoperative 168.40°) were significantly increased (P < 0.05). NFA (preoperative 139.20° vs. postoperative 133.50°, P < 0.05) and NTA (preoperative 43.76° vs. postoperative 35.80°, P = 0.062) were decreased. On the cleft versus non-cleft sides, the ratios of S (preoperative 1.10 vs. postoperative 0.94, P < 0.05), w (preoperative 1.10 vs. postoperative 1.02, P = 0.194), h1 (preoperative 0.71 vs. postoperative 0.90, P < 0.05), and h2 (preoperative 0.53 vs. postoperative 0.79, P = 0.065) were all near 1. Satisfaction with postoperative results was fairly high.
		                        		
		                        			Conclusion
		                        			The costal cartilage strut-septum complex stent can effectively correct the deflection and collapse of the nasal tip in patients with unilateral cleft lip nose deformity. The postoperative long-term effect is relatively stable.
		                        		
		                        		
		                        		
		                        	
2.Role and Mechanism of Cucurbitacin B in Suppressing Proliferation of Breast Cancer 4T1 Cells via Inducing Ferroptosis
Yidan RUAN ; Huizhong ZHANG ; Huating HUANG ; Pingzhi ZHANG ; Aina YAO ; Yongqiang ZHANG ; Xiaohan XU ; Shiman LI ; Jian NI ; Xiaoxu DONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(7):91-97
		                        		
		                        			
		                        			ObjectiveTo explore the role of cucurbitacin B (CuB) in inducing ferroptosis in 4T1 cells and its mechanism. MethodsThe effects of CuB(0.2, 0.4, 0.8 μmol·L-1)on the proliferation ability of 4T1 cells in vitro were detected using the methyl thiazolyl tetrazolium (MTT) assay. The clonogenic ability of 4T1 cells was detected by the plate cloning assay, and the levels of lactate dehydrogenase (LDH) in 4T1 cells were detected by the use of a kit. The mitochondrial membrane potential and reactive oxygen species (ROS) levels in 4T1 cells were detected by flow cytometry, and the mitochondrial ultrastructure of 4T1 cells was observed by transmission electron microscopy. The western blot was used to detect the expression of ferroptosis-related protein p53 in 4T1 cells, solute carrier family 7 member 11 (SCL7A11), glutathione peroxidase 4 (GPX4), long-chain acyl-CoA synthetase 4 (ACSL4), transferrin receptor protein 1 (TFR1), and ferritin heavy chain 1 (FTH1). ResultsCompared with that in the blank group, the survival rate of 4T1 cells in CuB groups was significantly decreased (P<0.05), and the number of cell clones in CuB groups was significantly reduced (P<0.01). In addition, compared with that in the blank group, the leakage of LDH in cells in CuB groups was significantly increased (P<0.01), and the mitochondrial membrane potential of cells in CuB groups decreased significantly (P<0.01). Cellular ROS levels were significantly elevated in CuB groups (P<0.01). The mitochondria of cells in CuB groups were obviously wrinkled, and the mitochondrial cristae were reduced or even disappeared. Compared with that in the blank group, the protein expression of p53, ACSL4, and TFR1 were significantly up-regulated in CuB groups (P<0.05), and that of SLC7A11, GPX4, and FTH1 were significantly down-regulated (P<0.05). ConclusionCuB may inhibit SLC7A11 and GPX4 expression by up-regulating the expression of p53, which in turn regulates the p53/SLC7A11/GPX4 signaling pathway axis and accelerates the generation of lipid peroxidation substrate by up-regulating the expression of ACSL4. It up-regulates TFR1 expression to promote cellular uptake of Fe3+ and down-regulates the expression of FTH1 to reduce the ability of iron storage, resulting in an elevated free Fe2+ level. It catalyzes the Fenton reaction, generates excess ROS, imbalances the antioxidant system and iron metabolism, and then induces ferroptosis in 4T1 cells. 
		                        		
		                        		
		                        		
		                        	
3.Role and Mechanism of Cucurbitacin B in Suppressing Proliferation of Breast Cancer 4T1 Cells via Inducing Ferroptosis
Yidan RUAN ; Huizhong ZHANG ; Huating HUANG ; Pingzhi ZHANG ; Aina YAO ; Yongqiang ZHANG ; Xiaohan XU ; Shiman LI ; Jian NI ; Xiaoxu DONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(7):91-97
		                        		
		                        			
		                        			ObjectiveTo explore the role of cucurbitacin B (CuB) in inducing ferroptosis in 4T1 cells and its mechanism. MethodsThe effects of CuB(0.2, 0.4, 0.8 μmol·L-1)on the proliferation ability of 4T1 cells in vitro were detected using the methyl thiazolyl tetrazolium (MTT) assay. The clonogenic ability of 4T1 cells was detected by the plate cloning assay, and the levels of lactate dehydrogenase (LDH) in 4T1 cells were detected by the use of a kit. The mitochondrial membrane potential and reactive oxygen species (ROS) levels in 4T1 cells were detected by flow cytometry, and the mitochondrial ultrastructure of 4T1 cells was observed by transmission electron microscopy. The western blot was used to detect the expression of ferroptosis-related protein p53 in 4T1 cells, solute carrier family 7 member 11 (SCL7A11), glutathione peroxidase 4 (GPX4), long-chain acyl-CoA synthetase 4 (ACSL4), transferrin receptor protein 1 (TFR1), and ferritin heavy chain 1 (FTH1). ResultsCompared with that in the blank group, the survival rate of 4T1 cells in CuB groups was significantly decreased (P<0.05), and the number of cell clones in CuB groups was significantly reduced (P<0.01). In addition, compared with that in the blank group, the leakage of LDH in cells in CuB groups was significantly increased (P<0.01), and the mitochondrial membrane potential of cells in CuB groups decreased significantly (P<0.01). Cellular ROS levels were significantly elevated in CuB groups (P<0.01). The mitochondria of cells in CuB groups were obviously wrinkled, and the mitochondrial cristae were reduced or even disappeared. Compared with that in the blank group, the protein expression of p53, ACSL4, and TFR1 were significantly up-regulated in CuB groups (P<0.05), and that of SLC7A11, GPX4, and FTH1 were significantly down-regulated (P<0.05). ConclusionCuB may inhibit SLC7A11 and GPX4 expression by up-regulating the expression of p53, which in turn regulates the p53/SLC7A11/GPX4 signaling pathway axis and accelerates the generation of lipid peroxidation substrate by up-regulating the expression of ACSL4. It up-regulates TFR1 expression to promote cellular uptake of Fe3+ and down-regulates the expression of FTH1 to reduce the ability of iron storage, resulting in an elevated free Fe2+ level. It catalyzes the Fenton reaction, generates excess ROS, imbalances the antioxidant system and iron metabolism, and then induces ferroptosis in 4T1 cells. 
		                        		
		                        		
		                        		
		                        	
4.Research progress of natural bioactive products in resisting loss of skin collagen
Chu-juan HU ; Lu-lu WANG ; Jian-dong JIANG ; Rui LI
Acta Pharmaceutica Sinica 2025;60(2):269-279
		                        		
		                        			
		                        			 As the biggest tissue of human body, skin is the first barrier of resisting external aggression. Collagen is one of important parts of the skin, which could not only affect the aesthetics of skin, but also influence the health and normal function of skin. It is the great significance to find ways that could inhibit the loss of collagen. The mechanisms of the collagen degradation in skin are complex and multifaceted. Natural bioactive products have unique advantages in treating the loss of collagen, which have multi-targets and mechanisms. In this review, the mechanisms of skin collagen degradation are discussed, and the research progress of natural bioactive products in resisting skin aging through promoting collagen synthesis are reviewed, in order to provide references for futural research. 
		                        		
		                        		
		                        		
		                        	
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
8.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
10.Preparation of mouse monoclonal antibodies against the ectodomain of Western equine encephalitis virus E2 (E2ecto) protein.
Fuxing WU ; Yangchao DONG ; Jian ZHANG ; Pan XUE ; Ruodong YUAN ; Yang CHEN ; Hang YUAN ; Baoli LI ; Yingfeng LEI
Chinese Journal of Cellular and Molecular Immunology 2024;40(1):62-68
		                        		
		                        			
		                        			Objective To prepare mouse monoclonal antibodies against the ectodomain of E2 (E2ecto) glycoprotein of Western equine encephalitis virus (WEEV). Methods A prokaryotic expression plasmid pET-28a-WEEV E2ecto was constructed and transformed into BL21 (DE3) competent cells. E2ecto protein was expressed by IPTG induction and presented mainly as inclusion bodies. Then the purified E2ecto protein was prepared by denaturation, renaturation and ultrafiltration. BALB/c mice were immunized with the formulated E2ecto protein using QuickAntibody-Mouse5W as an adjuvant via intramuscular route, boosted once at an interval of 21 days. At 35 days post-immunization, mice with antibody titer above 1×104 were inoculated with E2ecto intraperitoneally, and spleen cells were fused with SP2/0 cells three days later. Hybridoma cells secreting specific monoclonal antibodies were screened by the limited dilution method, and ascites were prepared after intraperitoneal inoculation of hybridoma cells. The subtypes and titers of the antibodies in ascites were assayed by ELISA. The biological activity of the mAb was identified by immunofluorescence assay(IFA) on BHK-21 cells which were transfected with eukaryotic expression plasmid pCAGGS-WEEV-CE3E2E1. The specificity of the antibodies were evaluated with E2ecto proteins from EEEV and VEEV. Results Purified WEEV E2ecto protein was successfully expressed and obtained. Four monoclonal antibodies, 3G6G10, 3D7G2, 3B9E8 and 3D5B7, were prepared, and their subtypes were IgG2c(κ), IgM(κ), IgM(κ) and IgG1(κ), respectively. The titers of ascites antibodies 3G6G10, 3B9E8 and 3D7G2 were 105, and 3D5B7 reached 107. None of the four antibody strains cross-reacted with other encephalitis alphavirus such as VEEV and EEEV. Conclusion Four strains of mouse mAb specifically binding WEEV E2ecto are successfully prepared.
		                        		
		                        		
		                        		
		                        			Horses
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Encephalitis Virus, Western Equine
		                        			;
		                        		
		                        			Ascites
		                        			;
		                        		
		                        			Immunosuppressive Agents
		                        			;
		                        		
		                        			Antibodies, Monoclonal
		                        			;
		                        		
		                        			Immunoglobulin M
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail