1.Construction of a predictive model for poorly differentiated adenocarcinoma in pulmonary nodules using CT combined with tumor markers
Jie JIANG ; Feng LIU ; Bo WANG ; Qin WANG ; Jian ZHONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):73-79
Objective To establish and internally validate a predictive model for poorly differentiated adenocarcinoma based on CT imaging and tumor marker results. Methods Patients with solid and partially solid lung nodules who underwent lung nodule surgery at the Department of Thoracic Surgery, the Affiliated Brain Hospital of Nanjing Medical University in 2023 were selected and randomly divided into a training set and a validation set at a ratio of 7:3. Patients' CT features, including average density value, maximum diameter, pleural indentation sign, and bronchial inflation sign, as well as patient tumor marker results, were collected. Based on postoperative pathological results, patients were divided into a poorly differentiated adenocarcinoma group and a non-poorly differentiated adenocarcinoma group. Univariate analysis and logistic regression analysis were performed on the training set to establish the predictive model. The receiver operating characteristic (ROC) curve was used to evaluate the model's discriminability, the calibration curve to assess the model's consistency, and the decision curve to evaluate the clinical value of the model, which was then validated in the validation set. Results A total of 299 patients were included, with 103 males and 196 females, with a median age of 57.00 (51.00, 67.25) years. There were 211 patients in the training set and 88 patients in the validation set. Multivariate analysis showed that carcinoembryonic antigen (CEA) value [OR=1.476, 95%CI (1.184, 1.983), P=0.002], cytokeratin 19 fragment antigen (CYFRA21-1) value [OR=1.388, 95%CI (1.084, 1.993), P=0.035], maximum tumor diameter [OR=6.233, 95%CI (1.069, 15.415), P=0.017], and average density [OR=1.083, 95%CI (1.020, 1.194), P=0.040] were independent risk factors for solid and partially solid lung nodules as poorly differentiated adenocarcinoma. Based on this, a predictive model was constructed with an area under the ROC curve of 0.896 [95%CI (0.810, 0.982)], a maximum Youden index corresponding cut-off value of 0.103, sensitivity of 0.750, and specificity of 0.936. Using the Bootstrap method for 1000 samplings, the calibration curve predicted probability was consistent with actual risk. Decision curve analysis indicated positive benefits across all prediction probabilities, demonstrating good clinical value. Conclusion For patients with solid and partially solid lung nodules, preoperative use of CT to measure tumor average density value and maximum diameter, combined with tumor markers CEA and CYFRA21-1 values, can effectively predict whether it is poorly differentiated adenocarcinoma, allowing for early intervention.
2.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure
3.Construction of management index system for rational drug use of key monitoring drugs
Mingxiong ZHANG ; Wanying QIN ; Jian HUANG ; Dan WANG ; Li LI ; Yinghui BU ; Ming YAN ; Kejia LI
China Pharmacy 2025;36(7):784-788
OBJECTIVE To establish management index system for rational drug use of key monitoring drugs, and provide reference for the management of key monitoring drugs in the hospitals. METHODS First, the management index system for rational drug use of key monitoring drugs was drafted by collecting the evidence from related medical literature. Next, using a modified Delphi method, twenty experienced experts from the fields of pharmacy, medical practice, healthcare insurance, and finance were selected to participate in two rounds of questionnaire consultations. Based on the expert enthusiasm coefficient, authority coefficient, degree of opinion concentration, and degree of coordination, the final indicators were determined to establish a management index system for rational drug use of key monitored drugs in medical institutions. RESULTS The expert enthusiasm coefficients reached 100% in both rounds of consultation. In first-level, second-level and third-level indicators, the authority coefficients of experts were 0.89, 0.86 and 0.87, and coordination coefficients of the experts in importance score were 0.300 (P< 0.05), 0.125 (P<0.05) and 0.139 (P<0.05), respectively. The average score for the importance of all indicators reached over 3.5, in which the full score ratio ranged from 35% to 100%. Except that the variation coefficient of a third-level indicator “number of specifications purchased for key monitored drugs” was 0.26, the variation coefficients of rest indicators were less than or equal to 0.25. Based on the results of expert consultation, final version of the management index system established in this study, including two first-level indicators (drug procurement and use, and rational drug use), five second-level indicators (such as the accessibility, cost-effectiveness) and twenty third-level indicators (such as the number of specifications purchased for key monitored drugs, the increase in the cost of key monitored drugs). CONCLUSIONS The management index system established in this study possesses high reliability and strong operability, and may provide a reference for the management of key monitoring drugs in the hospitals.
4.Trends in global burden due to visceral leishmaniasis from 1990 to 2021 and projections up to 2035
Guobing YANG ; Aiwei HE ; Yongjun LI ; Shan LÜ ; Muxin CHEN ; Liguang TIAN ; Qin LIU ; Lei DUAN ; Yan LU ; Jian YANG ; Shizhu LI ; Xiaonong ZHOU ; Jichun WANG ; Shunxian ZHANG
Chinese Journal of Schistosomiasis Control 2025;37(1):35-43
Objective To investigate the global burden of visceral leishmaniasis (VL) from 1990 to 2021 and predict the trends in the burden of VL from 2022 to 2035, so as to provide insights into global VL prevention and control. Methods The global age-standardized incidence, prevalence, mortality and disability-adjusted life years (DALYs) rates of VL and their 95% uncertainty intervals (UI) were captured from the Global Burden of Disease Study 2021 (GBD 2021) data resources. The trends in the global burden of VL were evaluated with average annual percent change (AAPC) and 95% confidence interval (CI) from 1990 to 2021, and gender-, age-, country-, geographical area- and socio-demographic index (SDI)-stratified burdens of VL were analyzed. The trends in the global burden of VL were projected with a Bayesian age-period-cohort (BAPC) model from 2022 to 2035, and the associations of age-standardized incidence, prevalence, mortality, and DALYs rates of VL with SDI levels were examined with a smoothing spline model. Results The global age-standardized incidence [AAPC = -0.25%, 95% CI: (-0.25%, -0.24%)], prevalence [AAPC = -0.06%, 95% CI: (-0.06%, -0.06%)], mortality [AAPC = -0.25%, 95% CI: (-0.25%, -0.24%)] and DALYs rates of VL [AAPC = -2.38%, 95% CI: (-2.44%, -2.33%)] all appeared a tendency towards a decline from 1990 to 2021, and the highest age-standardized incidence [2.55/105, 95% UI: (1.49/105, 4.07/105)], prevalence [0.64/105, 95% UI: (0.37/105, 1.02/105)], mortality [0.51/105, 95% UI: (0, 1.80/105)] and DALYs rates of VL [33.81/105, 95% UI: (0.06/105, 124.09/105)] were seen in tropical Latin America in 2021. The global age-standardized incidence and prevalence of VL were both higher among men [0.57/105, 95% UI: (0.45/105, 0.72/105); 0.14/105, 95% UI: (0.11/105, 0.18/105)] than among women [0.27/105, 95% UI: (0.21/105, 0.33/105); 0.06/105, 95% UI: (0.05/105, 0.08/105)], and the highest mortality of VL was found among children under 5 years of age [0.24/105, 95% UI: (0.08/105, 0.66/105)]. The age-standardized incidence (r = -0.483, P < 0.001), prevalence (r = -0.483, P < 0.001), mortality (r = -0.511, P < 0.001) and DALYs rates of VL (r = -0.514, P < 0.001) correlated negatively with SDI levels from 1990 to 2021. In addition, the global burden of VL was projected with the BAPC model to appear a tendency towards a decline from 2022 to 2035, and the age-standardized incidence, prevalence, mortality and DALYs rates were projected to be reduced to 0.11/105, 0.03/105, 0.02/105 and 1.44/105 in 2035, respectively. Conclusions Although the global burden of VL appeared an overall tendency towards a decline from 1990 to 2021, the burden of VL showed a tendency towards a rise in Central Asia and western sub-Saharan African areas. The age-standardized incidence and prevalence rates of VL were relatively higher among men, and the age-standardized mortality of VL was relatively higher among children under 5 years of age. The global burden of VL was projected to continue to decline from 2022 to 2035.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Incremental effectiveness of two-dose of mumps-containing vaccine in chidren
Chinese Journal of School Health 2025;46(6):883-887
Objective:
To evaluate the incremental vaccine effectiveness (VE) of two dose of the mumps containing vaccine (MuCV) in chidren, so as to provide a basis for optimizing mumps immunization strategies.
Methods:
A 1∶2 frequency matched case-control study was conducted by using reported mumps cases in childcare centers or schools from Lu an, Hefei, Ma anshan and Huainan cities of Anhui Province from September 1, 2023 to June 30, 2024, as a case group(383 cases). And healthy children in the same classroom were selected as a control group(766 cases). The MuCV immunization histories of participants were collected to estimate the incremental VE of the second dose of MuCV against mumps. Group comparisons were performed using the Chi square test or t-test. For matched case-control pairs, the Cox regression model was employed to calculate the odds ratio (OR) with 95% confidence interval (CI) for two dose MuCV vaccination and to estimate the incremental vaccine effectiveness (VE).
Results:
There were no statistically significant differences between the case and control groups regarding gender, age, dosage of MuCV vaccination and the time interval since the last dose vaccination( χ 2/t=0.05, 0.20, 0.94, -0.02, P >0.05). The proportions of the case and control groups vaccinated with two doses of MuCV were 26.63% and 29.37%, respectively, and the overall incremental VE of the second dose of MuCV was 40.73% (95% CI=3.03%-63.77%, P <0.05). Subgroup analyses revealed that the incremental VE for children with a period of ≥1 year between the two doses of MuCV was 54.13% (95% CI=1.90%-78.56%, P <0.05), while for children with a period of <1 year, it was 30.63% (95% CI=-28.59%-62.58%, P >0.05). The incremental VE of the second dose of MuCV was 30.36% (95% CI=-25.95%-61.50%, P >0.05) in kindergarten children and 66.73% (95% CI=14.92%-86.99%, P <0.05) in elementary and secondary school students. The incremental VE was 28.78% (95% CI=-27.46%-60.21%, P >0.05) within five years of the last dose of MuCV vaccination and 66.07% (95% CI=-41.56%-91.87%, P >0.05) for vaccinations administered beyond five years.
Conclusions
The second dose of MuCV may offer additional protection for children; however, extending the interval between two dose of MuCV (<1 year) has shown limited incremental protective effects. Therefore, it is crucial to consider optimizing current immunization strategies for mumps.


Result Analysis
Print
Save
E-mail