1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Application of the OmniLogTM microbial identification system in the detection of the host spectrum for wild-type plague phage in Qinghai Plateau
Cun-Xiang LI ; Zhi-Zhen QI ; Qing-Wen ZHANG ; Hai-Hong ZHAO ; Long MA ; Pei-Song YOU ; Jian-Guo YANG ; Hai-Sheng WU ; Jian-Ping FENG
Chinese Journal of Zoonoses 2024;40(1):21-25
		                        		
		                        			
		                        			The growth of three plague phages from Qinghai Plateau in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,PTB5,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were detected through a micromethod based on the OmniLogTM microbial identification system and by the drop method,to provide a scientific basis for future ecological studies and classification based on the host range.For plague vaccine strains EV76 and 614F,successful phage infection and subsequent phage growth were observed in the host bacte-rium.Diminished bacterial growth and respiration and a concomitant decrease in color were observed with the OmniLogTM mi-crobial identification system at 33 ℃ for 48 h.Yersinia pseudotuberculosis PTB5 was sensitive to Yersinia pestis phage 476,but Yersinia pseudotuberculosis PST5 was insensitive to phage 087 and 072204.Three strains of non-Yersinia pestis(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were insensitive to Yersinia pestis pha-ges 087,072204,and 476 showed similar growth curves.The growth of phages 476 and 087,as determined with the drop method,in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersin-ia enterocolitica 52302-2)showed the same results at 37 ℃,on the basis of comparisons with the OmniLogTM microbial i-dentification system;in contrast,phages 072204 did not show plaques on solid medium at 37 ℃ with plague vaccine strains EV76 and 614F.Determination based on the OmniLogTM detection system can be used as an alternative to the traditional determination of the host range,thus providing favorable application val-ue for determining the interaction between the phage and host bacteria.
		                        		
		                        		
		                        		
		                        	
7.Safety and efficacy of domestically produced novel bioabsorbable vascular scaff old in the treatment of complex coronary artery lesions for 3 years
Deng-Shuang ZHOU ; Qiong YOU ; Hai-Liang MO ; Zi-Jun WU ; Yu-Biao LIN ; Lu-Jun CHEN ; Jun-Yu FAN ; Yong-Jian LIN ; Rui-Sheng ZHANG ; Pei-Shan WAN ; Wei-Guo ZHOU ; Keng WU
Chinese Journal of Interventional Cardiology 2024;32(9):509-515
		                        		
		                        			
		                        			Objective To investigate the safety and efficacy of novel bioabsorbable vascular scaffold(BVS)in the treatment of patients with complex coronary artery disease.Methods This was a retrospective,matched,single-center observational study.45 patients with coronary atherosclerotic cardiopathy received BVS treatment in the cardiovascular medicine department Department of the Affiliated Hospital of Guangdong Medical University from June 2020 to June 2021(BVS),and 45 patients treated with drug-eluting stents(DES)group were selected according to matching study requirements during the same period.Baseline,surgical,and follow-up data were compared between the two groups to evaluate safety and efficacy.The main measures of safety were:surgical time,intraoperative adverse events,etc.,and the end point of efficacy was target lesion failure(TLF),including cardiac death,target vessel myocardial infarction,and ischa-driven target lesion revascularization.Results A total of 90 patients were enrolled in this study,all of whom were followed up for at least 3 years.There were 20 cases of bifurcation lesions and 25 cases of diffuse long lesions in the two groups,and 50 cases of imaging were reviewed among the 90 patients.The proportion of stable coronary heart disease,history of diabetes,history of hypertension,history of smoking,pre-dilated balloon pressure and postoperative diastolic blood pressure in BVS group was higher than that in DES group,and the proportion of family history was lower than that in DES group(all P<0.05).There were no statistically significant differences in the rates of cardiac death,target vessel myocardial infarction,and ischemia-driven revascularization of target lesions between the two groups(all P>0.05).Binary Logistic regression model analysis showed that the diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis(OR 2.786,95%CI 1.096-7.081,P=0.031).Conclusions Compared with traditional DES,BVS implantation has consistent safety and efficacy in the treatment of complex coronary artery disease within 3 years.The diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis.
		                        		
		                        		
		                        		
		                        	
8.Problems and countermeasures of inspection of upper and lower limb motor rehabilitation training devices
Xiao-Juan PEI ; Shuo JIANG ; Shu-Jian FAN ; Zheng LIU ; Ke ZHANG
Chinese Medical Equipment Journal 2024;45(2):87-91
		                        		
		                        			
		                        			The upper and lower limb motor rehabiliation training devices were introduced in terms of classification,working principle and inspection standard.The causes for unqualification of the devices were analyzed in input power,touch current under single-fault condition,emergency stop mechanism,activation time of spastic protection,extrusion of moving parts and emergency voice-controlled switch,and the countermeasures were put forward accordingly.References were provided for decreasing the safety risks of similar devices and increasing the qualification rate of type inspection.[Chinese Medical Equipment Journal,2024,45(2):87-91]
		                        		
		                        		
		                        		
		                        	
9.Analysis of the causes of cage subsidence after oblique lateral lumbar interbody fusion
Zhong-You ZENG ; Ping-Quan CHEN ; Xing ZHAO ; Hong-Fei WU ; Jian-Qiao ZHANG ; Xiang-Qian FANG ; Yong-Xing SONG ; Wei YU ; Fei PEI ; Shun-Wu FAN ; Guo-Hao SONG ; Shi-Yang FAN
China Journal of Orthopaedics and Traumatology 2024;37(1):33-44
		                        		
		                        			
		                        			Objective To observe the cage subsidence after oblique lateral interbody fusion(OLIF)for lumbar spondylo-sis,summarize the characteristics of the cage subsidence,analyze causes,and propose preventive measures.Methods The data of 144 patients of lumbar spine lesions admitted to our hospital from October 2015 to December 2018 were retrospectively ana-lyzed.There were 43 males and 101 females,and the age ranged from 20 to 81 years old,with an average of(60.90±10.06)years old.Disease types:17 patients of lumbar intervertebral disc degenerative disease,12 patients of giant lumbar disc hernia-tion,5 patients of discogenic low back pain,33 patients of lumbar spinal stenosis,26 patients of lumbar degenerative spondy-lolisthesis,28 patients of lumbar spondylolisthesis with spondylolisthesis,11 patients of adjacent vertebral disease after lumbar internal fixation,7 patients of primary spondylitis in the inflammatory outcome stage,and 5 patients of lumbar degenerative scoliosis.Preoperative dual-energy X-ray bone mineral density examination showed 57 patients of osteopenia or osteoporosis,and 87 patients of normal bone density.The number of fusion segments:124 patients of single-segment,11 patients of two-seg-ment,8 patients of three-segment,four-segment 1 patient.There were 40 patients treated by stand-alone OLIF,and 104 patients by OLIF combined with posterior pedicle screw.Observed the occurrence of fusion cage settlement after operation,conducted monofactor analysis on possible risk factors,and observed the influence of fusion cage settlement on clinical results.Results All operations were successfully completed,the median operation time was 99 min,and the median intraoperative blood loss was 106 ml.Intraoperative endplate injury occurred in 30 patients and vertebral fracture occurred in 5 patients.The mean follow-up was(14.57±7.14)months from 6 to 30 months.During the follow-up,except for the patients of primary lumbar interstitial in-flammation and some patients of lumbar spondylolisthesis with spondylolisthesis,the others all had different degrees of cage subsidence.Cage subsidence classification:119 patients were normal subsidence,and 25 patients were abnormal subsidence(23 patients were grade Ⅰ,and 2 patients were grade Ⅱ).There was no loosening or rupture of the pedicle screw system.The height of the intervertebral space recovered from the preoperative average(9.48±1.84)mm to the postoperative average(12.65±2.03)mm,and the average(10.51±1.81)mm at the last follow-up.There were statistical differences between postop-erative and preoperative,and between the last follow-up and postoperative.The interbody fusion rate was 94.4%.The low back pain VAS decreased from the preoperative average(6.55±2.2 9)to the last follow-up(1.40±0.82),and there was statistically significant different.The leg pain VAS decreased from the preoperative average(4.72±1.49)to the final follow-up(0.60± 0.03),and the difference was statistically significant(t=9.13,P<0.000 1).The ODI index recovered from the preoperative av-erage(38.50±6.98)%to the latest follow-up(11.30±3.27)%,and there was statistically significant different.The complication rate was 31.3%(45/144),and the reoperation rate was 9.72%(14/144).Among them,8 patients were reoperated due to fusion cage subsidence or displacement,accounting for 57.14%(8/14)of reoperation.The fusion cage subsidence in this group had obvious characteristics.The monofactor analysis showed that the number of abnormal subsidence patients in the osteopenia or osteoporosis group,Stand-alone OLIF group,2 or more segments fusion group,and endplate injury group was higher than that in the normal bone mass group,OLIF combined with pedicle screw fixation group,single segment fusion group,and no endplate injury group,and the comparison had statistical differences.Conclusion Cage subsidence is a common phenomenon after 0-LIF surgery.Preoperative osteopenia or osteoporosis,Stand-alone OLIF,2 or more segments of fusion and intraoperative end-plate injury may be important factors for postoperative fusion cage subsidence.Although there is no significant correlation be-tween the degree of cage subsidence and clinical symptoms,there is a risk of cage migration,and prevention needs to be strengthened to reduce serious complications caused by fusion of cage subsidence,including reoperation.
		                        		
		                        		
		                        		
		                        	
10.Bioequivalence study of ezetimibe tablets in Chinese healthy subjects
Pei-Yue ZHAO ; Tian-Cai ZHANG ; Yu-Ning ZHANG ; Ya-Fei LI ; Shou-Ren ZHAO ; Jian-Chang HE ; Li-Chun DONG ; Min SUN ; Yan-Jun HU ; Jing LAN ; Wen-Zhong LIANG
The Chinese Journal of Clinical Pharmacology 2024;40(16):2378-2382
		                        		
		                        			
		                        			Objective To evaluate the bioequivalence and safety of ezetimibe tablets in healthy Chinese subjects.Methods The study was designed as a single-center,randomized,open-label,two-period,two-way crossover,single-dose trail.Subjects who met the enrollment criteria were randomized into fasting administration group and postprandial administration group and received a single oral dose of 10 mg of the subject presparation of ezetimibe tablets or the reference presparation per cycle.The blood concentrations of ezetimibe and ezetimibe-glucuronide conjugate were measured by high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS),and the bioequivalence of the 2 preparations was evaluated using the WinNonlin 7.0 software.Pharmacokinetic parameters were calculated to evaluate the bioequivalence of the 2 preparations.The occurrence of all adverse events was also recorded to evaluate the safety.Results The main pharmacokinetic parameters of total ezetimibe in the plasma of the test and the reference after a single fasted administration:Cmax were(118.79±35.30)and(180.79±51.78)nmol·mL-1;tmax were 1.40 and 1.04 h;t1/2 were(15.33±5.57)and(17.38±7.24)h;AUC0-t were(1 523.90±371.21)and(1 690.99±553.40)nmol·mL-1·h;AUC0-∞ were(1 608.70±441.28),(1 807.15±630.00)nmol·mL-1·h.The main pharmacokinetic parameters of total ezetimibe in plasma of test and reference after a single meal:Cmax were(269.18±82.94)and(273.93±87.78)nmol·mL-1;Tmax were 1.15 and 1.08 h;t1/2 were(22.53±16.33)and(16.02±5.84)h;AUC0_twere(1 463.37±366.03),(1 263.96±271.01)nmol·mL-1·h;AUC0-∞ were(1 639.01±466.53),(1 349.97±281.39)nmol·mL-1·h.The main pharmacokinetic parameters Cmax,AUC0-tand AUC0-∞ of the two preparations were analyzed by variance analysis after logarithmic transformation.In the fasting administration group,the 90%CI of the log-transformed geometric mean ratios were within the bioequivalent range for the remaining parameters in the fasting dosing group,except for the Cmax of ezetimibe and total ezetimibe,which were below the lower bioequivalent range.The Cmax of ezetimibe,ezetimibe-glucuronide,and total ezetimibe in the postprandial dosing group was within the equivalence range,and the 90%CI of the remaining parameters were not within the equivalence range for bioequivalence.Conclusion This test can not determine whether the test preparation and the reference preparation of ezetimibe tablets have bioequivalence,and further clinical trials are needed to verify it.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail